User Manual for LIGHT BRICKS models including: Arond200 LED Moving Head Spot, Arond200, LED Moving Head Spot, Moving Head Spot, Head Spot, Spot
File Info : application/pdf, 17 Pages, 1.71MB
DocumentDocumentArond 200 LED Moving Head Spot User Manual V 1.0 Contents 1. Introduction 2. Safety Instructions 3. Unpacking the device 4. Installation 5. DMX Connection 6. Montage der Geräte 7. Control panel 8. Channel assignment 9. Gobos and color wheel 10. Photometric data 11. Service and cleaning 12. Information 13. Technical details Light Bright Arond 200 3 4 6 6 7 8 9 11 13 14 15 16 17 2 1. Introduction Light Bright Arond 200 ATTENTION: For your own safety, please read these operating instructions carefully before the first use. The product has left our company in best condition. To maintain this condition and to ensure safe operation, it is absolutely necessary to observe the following safety instructions and warnings, which are described in this operating manual. The manufacturer accepts no liability for damage caused by failure to comply with these operating instructions or unauthorized modifications to the device. Please note that damages caused by manual changes to this device are not covered by the warranty. ATTENTION: This device is for professional use only! Protection class IP 20 - only for use in dry environment (indoor)! Light Bright does not authorize the use of your devices in life support systems. Life Support Systems are systems whose purpose is to maintain or stabilize life and whose defect or malfunction could result in death or injury to persons. 3 2. Safety Instructions Light Bright Arond 200 CAUTION: Disconnect the device from the power supply before opening the device. Touching live parts can cause an electric shock. Make sure that the mains voltage to be connected is not higher than the voltage indicated on the type plate. This device should only be operated with the power source specified on the type plate. If you are not sure what type of power supply you have, contact your dealer or your power company. Always disconnect the device from the power supply before carrying out cleaning work, changing fuses or replacing parts. The mains plug must always be accessible after installation of the spotlight. Do not overload the sockets or extension cords under any circumstances, as this could lead to fire or electric shock. Do not place any objects on the power cord. Do not install the spotlight in such a way that people can trip over the power cord or step on it. Make sure that the power cord can never be crushed or damaged by sharp edges. Check the unit and the power cord from time to time Always leave maintenance work to a qualified technician. ATTENTION: This light corresponds to protection class 1 (Germany)Therefore this light must be connected to a mains socket with earthing contact. Never connect this device to a dimmable power source. Some smoke and odour may be produced during the initial start-up. This is a normal procedure and does not necessarily mean that the device is defective. The device becomes hot during operation. Never touch the device with bare hands during operation! When replacing fuses, use only fuses of the same type with identical values. Have fuses replaced only by a qualified technician. 4 Light Bright Arond 200 ATTENTION: EYE DAMAGE! Do not look into the light source for a long time during operation. This can be harmful to the eyes. Possibly dangerous radiation. If the device was exposed to strong temperature fluctuations (e.g. after transport), the device must not be switched on immediately. The resulting condensation water can damage your device. Leave the device switched off until it has reached room temperature. Do not shake or bump the device. Avoid brute force during installation or operation. This spotlight was designed for indoor use only. Do not expose this unit to rain or moisture. When choosing the mounting location, make sure that the device is not exposed to extreme heat, humidity or dust. Ventilation openings and slits in the head and foot of the headlamp serve for ventilation. To ensure reliable operation of the device and to protect it from overheating, these openings must not be covered. Never cover the front lens when the headlight is in use. The openings should never be covered with fabrics or other objects so that the airways are blocked. This unit must not be operated in an environment without adequate ventilation. The unit may only be operated when the housing is closed and all screws / omega head screws are tightened. The device must always be secured with an additional safety device. Make sure that the area underneath the spotlight is clear during installation, conversion and dismantling. ATTENTION: The distance between the light emission and the illuminated surface must be at least 2.0 meters. The front lens must be replaced if it is visibly damaged so that its function is impaired, e.g. by cracks or deep scratches! To avoid damage to the internal parts of the lamp head, never let sunlight shine directly into the front lens. 5 Light Bright The maximum ambient temperature of 45°C must not be exceeded. Arond 200 Do not operate the device until you have familiarized yourself with its functions. Prevent operation by persons who are not qualified to use the device. Most damage is the result of improper operation! Please use the original packaging or specially adapted flight cases when transporting the device. 3. Unpacking the device Contents of the package: The headlight, a PowerCon connection cable and Omega brackets for mounting. Open the packaging carefully on the top side and check the headlight and accessories for possible transport damages. These should be reported immediately to the transport company. 4. Installation The device comes with a ready made-up Powercon connection cable. Please use only the supplied cable or a cable of the same type assembled by a specialist. The connection of the device to the power supply must also be carried out by an authorized specialist. Connection in Germany/Europe: Leiterfarbe Brown Blue Yellow/Green Funktion Phase Neutral conductor Protective earth Symbol ,,L" ,,N" ,,PE" Connected loads: voltage 100-240 V, frequency 50 - 60 Hz, power max. 260W, 1.2A The electrical safety as well as the function of the device is only guaranteed if it is connected to a properly installed protective conductor system. It is very important that this basic safety requirement is present. In case of doubt, have the electrical installation checked by a specialist. The manufacturer cannot be held responsible for damage caused by a missing or interrupted protective conductor (e.g. electric shock)! Only use the device in a completely assembled state so that no electrical components can be touched. (danger 100-240 V) If you have observed the listed points, you can plug in the devices or have them connected to the mains by a specialist. 6 Light Bright Arond 200 ATTENTION: The spotlight may light up immediately if standalone operation is activated or a DMX signal is applied! 5. DMX Connection The DMX cabling (signal lines) should be done with a 2-wire cable with shielding. We recommend a DMX cable with 110 Ohm, 2x0,22mm2or 4x0,22mm2. The plugs and sockets are 3-pin XLR-connectors, which can be purchased in specialized shops. Pin assignment: Pin1 = Ground / Shielding Pin2 = DMX Pin3 = DMX + The spotlight has a DMX-in and DMX-out connection. Now connect the DMX output of your controller to the first spotlight (Controller DMX-Out -> Spotlight DMX-In). Then connect the first spotlight with the second spotlight and so on. In some cases it is advisable to plug in an end plug/end resistor (XLR plug with a resistor of 120 Ohm between pin 2 and pin 3). Whether or not an end plug is required depends on various factors, including the cable lengths used and the number of units. However, as long as there are no problems in the DMX line, it is not necessary. 7 6. Montage der Geräte Light Bright Arond 200 Warning: There must be a 0.5m safety distance between the light source and flammable material and a minimum distance of 2.0m between the light source and the surface to be illuminated. The spotlight can either be positioned or suspended from a truss system. Horizontal mounting to the truss is also permitted. If you place the unit on the floor, you may only operate the unit on a hard surface, as the air inlets in the foot must remain free! To hang the unit on a truss system, use the Omega-Clamps with snap connectors supplied. Make sure that the snap connectors engage securely. Make sure that the truss construction on which you mount the device complies with the safety regulations. When installing a truss, always secure the spotlight with a safety device that complies with the national regulations. Use the safety eyelet on the device for this purpose. Omega bracket Clamp Safety 1/4 Lock quick connector 8 7. Control panel Light Bright Arond 200 The spotlight has a display to show the set parameters and four buttons to adjust them. In addition, the Arond200 has an error LED to indicate any errors in the fixture, and a DMX LED to show the current DMX status. 1. DMX ADDRESS Here you can set the DMX address of the device. Press "OK" to enter the DMX settings. Use the buttons "up" and "down" to set the desired DMX address and confirm with "OK". 2. RUN MODE Here you can change the different working methods of the device. Press "OK" to enter the DMX settings. Use the buttons "up" and "down" to set the desired DMX address and confirm with ,,OK". The following modes are available: DMX512, Sound, Auto 1, Auto 2, Auto 3 "DMX512" is for controlling the spotlight using an external lighting console, "Auto 1-3" are built-in standalone sequences, "Sound" lets the spotlight react automatically to ambient music through a built-in microphone. 9 Light Bright 3. INVERT PAN Here you can invert the pan-movement of the device. Arond 200 Press "OK" to enter the settings and use the arrow keys to navigate to the sub-item "Invert Pan". Press "OK" again to confirm and set the inverter to "Yes" or "No" to switch the inversion on or off. Confirm again with "OK". 4. INVERT TILT Here the tilt-movement of the device can be inverted. Press "OK" to enter the settings and use the arrow keys to navigate to the submenu item "Invert Tilt". Press "OK" again to confirm and set the Invert to "Yes" or "No" to switch the inversion on or off. Confirm again with "OK". 5. SCREEN SAVER Here you can switch the screen saver on and off. Press "OK" to enter the settings and use the arrow keys to navigate to the sub-item "Screen Saver". Confirm again with "OK" and switch the screen saver on or off. Confirm with "OK" to save the settings. 6. CHECK Here you can control the spotlight directly on the device. Press "OK" to enter the settings and use the arrow keys to navigate to the "Check" sub-item. Confirm again with "OK". Here you can now change all parameters of the spotlight in the values 0-255. Navigate to the parameter you want to change and press "OK". Now the value of the parameter can be changed. After you have set the desired value, press "OK" again to save it. 7. LOAD DEFAULT Here you can reset all set parameters to factory settings Press "OK" to enter the settings and use the arrow keys to navigate to the sub-item "Load Default". Press "OK" again to confirm and reset all settings you have made by confirming them. 8. SYSTEM TEST Here the device performs an automatic test and runs all parameters and functions automatically. Press "OK" to enter the settings and use the arrow keys to navigate to the sub-item "System Test". Confirm again with "OK" and the headlight starts directly with the test program. 10 Light Bright Arond 200 9. MOTOR CALIBRATION Here the motors of the device can be fine-tuned. We recommend that this be carried out by a Light Bright service partner to ensure safe operation. 10. SYSTEM INFO Here the spotlight shows all relevant information such as firmware, temperatures, etc. 8. Channel assignment Channel 18 1 2 3 4 5 6 7 Value Pan (8bit) 0-255 Pan movement Pan fine (16bit) 0-255 Pan movement fine Tilt (8bit) 0-255 Tilt movement Tilt fine (16bit) 0-255 Tilt movement fine Position Speed 0-255 Position speed (fast-slow) Dimmer 0-255 0-100% intensity Shutter effect 0-3 Shutter open 2-99 Strobe 1 (slow-fast) 100-149 Strobe 2 (Pulse slow-fast) 150-199 Strobe 3 (Thunder slow-fast) 200-249 Strobe 4 (random fast-slow) 250-255 Shutter open Color Wheel 0 Open 1-179 Color 1-9 (all 20 values) Function 11 Channel 18 8 9 10 11 12 13 14 15 Light Bright Value Function 180-199 Open 200-226 Color wheel rotation (clockwise fast-slow) 227-228 Open 229-255 Color Wheel Rotation (counter-clockwise fast-slow) Static gobo-wheel 0-4 Open 5-54 Gobo 1-10 (all 5 DMX values) 55-154 Gobo 1-10 Shake effect (all 10 DMX values) 155-204 Gobo wheel rotation (clockwise fast-slow) 205 Stop 206-255 Gobo wheel rotation (counter-clockwise fast-slow) Rotating gobo-wheel 0-9 Open 10-79 Gobo 1-7 (all 10 DMX values) 80-159 Gobo 1-7 Shake effect (all 10 DMX values) 160-206 Gobo wheel rotation (clockwise (fast - slow) 207-208 Stop 209-255 Gobo wheel rotation (counter-clockwise fast-slow) Gobo Rotation 0-127 Gobo Position 128-191 Gobo Rotation (Clockwise fast-slow) 192-255 Gobo Rotation (Anti-Clockwise fast-slow) 4 fold prism 0-127 Offen 128-255 Prism Prism rotation 0-127 Prism positon 128-190 Prism rotation (clockwise fast-slow) 191-192 Stop 193-255 Prism rotation (counterclockwise fast-slow) Frost 0-127 Open 128-255 Frost Focus 0-255 Focus Arond 200 12 Channel 18 16 17 18 Light Bright Value Zoom 0-255 Zoom Macro effect 0-50 No function 51-100 System detection 101-150 Auto 1 151-200 Auto 2 201-255 Sound Reset 0-250 No function 251-255 Reset the fixture (after 5 sec) Function 9. Gobos and color wheel The Arond200 has two gobo wheels, each with 9 static (plus open) and 7 interchangeable rotatable and indexed gobos (plus open) The gobos have a size of 22.9mm outside and 19mm inside. In addition, the Arond200 has gobo scroll with variable speed. 9.1 Overview Arond 200 Gobo wheel static Gobo wheel rotatable 13 Light Bright 10. Photometric data LUX Data at 7° Beam 4m 6m 8m 25200 11600 6500 Arond 200 7° LUX Data at 21° Beam 4m 6m 8m 3260 1530 860 21° 14 Light Bright Arond 200 11. Service and cleaning ATTENTION: Always disconnect the device from the voltage source before opening it! You should check the function of the fans in the head and foot at regular intervals. Above all, you should make sure that the air intakes as well as the inside of the spotlight are free of lint and dust. To do this, open the head cover and the base plate at the foot. You can clean the spotlight with a brush/cleaning cloth and a vacuum cleaner or compressor (low speed only). Take care not to bend or damage any parts during cleaning. After cleaning is complete, close all covers again with the corresponding screws and carry out a function test. Please use only clean cleaning cloths or brushes and cleaning agents without alcohol to clean your device. We recommend regular cleaning at least every three months. Pay attention to damage to the device, parts of the device and the connection cables. If you notice any damage, DO NOT use the device and take it to an authorized dealer to exclude dangers by using defective devices and to repair your device professionally. 15 Light Bright Arond 200 12. Information This device complies with the CE directive: · in terms of the directive: 2014/35/EU Low Voltage Directive, (Directive 2014/35/EU of the European Parliament and of the Council of 26.02.2014 on the approximation of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits) · in terms of the directive: 2014/30/EU Electromagnetic Compatibility (Directive 2014/30/EU of the European Parliament and of the Council of 26.02.2014 on the approximation of the laws of the Member States relating to electromagnetic compatibility) The device complies with IP20 and is therefore protected against the penetration of solid foreign bodies with a diameter of more than 12mm (first code number 2), while it is sensitive to moisture, splash and jet water. During operation, it is mandatory to connect the device to a power supply system equipped with a powerful grounding (Class 1 device according to EN 60598-1). Furthermore, it is recommended to protect the supply line of the equipment from indirect contact and/or short circuits with correctly dimensioned residual current circuit breakers. Only use the device if the room temperature is below 45°C. Before starting any maintenance on the device, it must cool down for at least 10 minutes after being disconnected from power to minimize the risk of damage to the chips. For maintenance or repair work on the chips, the unit must cool down for at least another 20 minutes to prevent burning. 16 13. Technical details Power supply: AC100-240V,50-60Hz Light Bright Inrush current approx. 260W Light Source: 200W White LED Color temperature : 7500K Channel: 18 DMX channel Control: DMX/Master-slave/Auto/Sound Pan: 540° + fine Tilt: 270°+ fine Zoom range : 7-21°. Dimmer: 0-100% linear dimmer Strobe: 1-25 Hz with pulse-effect Color wheel: 9 colors + open, with half colors Static gobo wheel: 9 Gobos + open Rotatable gobo wheel : 7 gobos+open Prisma: 4 fold Prism with bi-direction Rotation Frost: mit Frost Effect Dimensions:343 x 239 x 537 mm Weight: 14.5 kg Arond 200 17Acrobat Distiller 22.0 (Windows)