Gen IV Open Protocol Instructions

Manuals - Aimco Global

Gen IV Controller Open Protocol Instructions - Aimco-Global

7 lug 2022 — Port Number: TCP port number the controller listens on to accept an. Open protocol connection via. Ethernet. The default port is. 4545 and can be changed if.

PDF preview unavailable. Download the PDF instead.

LIT-MAN177 OPENPROTOCOL rev 07-07-22
Gen IV Controller Open Protocol Instructions

The controller has the ability to accept an "Open" protocol connection. This connection is available over Ethernet and/or the standard serial ports. This connection allows you to enable/ disable the tool, set the active parameter set, collect rundown data, and much more. From the main menu, select Controller.
Select Protocols.
Then select Open Protocol.

· Port Number: TCP port number the controller listens on to accept an Open protocol connection via Ethernet. The default port is 4545 and can be changed if required.
· Cell ID: Optional variable passed through the Open Protocol Connection.
· Channel ID: Optional variable passed through the Open Protocol Connection.
· Controller Name: Optional variable passed through the Open Protocol Connection. To set up a serial port for Open Protocol, set the function on the desired COM port to "Open Protocol."
· Cable Loss Detection: Used only for an Open Serial protocol connection. When set to 1, the controller will close the connection on a time-out. When set to 0 the controller will not close the connection (see the latest Open Protocol Specification for details on time-outs) and keep alive messages.
· Connection Required: Determines whether an Open Protocol connection is required for the tool to operate. If checked, the tool will be disabled unless there is currently a connection.
· Send MID with ID: Some versions of the Open protocol specification defines MID 52 with an ID and some define it without an ID. This option is used to meet both versions of the specification.
· Connections: Currently active Open Protocol connections.

Controller Supported MIDs

Supported MID

MID Description

Revisions Note

1 Communication start 2 Communication start

1,2,3 1,2,3

acknowledge 3 Communication stop

4 Command error

5 Command accepted

8 Application data subscribe

Support MID 900

curve data only

9 Application data unsubscribe

Support MID 900

10 Parameter set ID upload request

curve data only

11 Parameter set ID upload reply

12 Parameter set data upload

request

13 Parameter set data upload reply

Always returns a

batch size of 0

14 Parameter set selected subscribe 15 Parameter set selected

16 Parameter set selected

acknowledge

17 Parameter set selected

unsubscribe

18 Select Parameter set

19 Set Parameter set batch size 20 Reset Parameter set batch

counter

30 Job ID upload request

31 Job ID upload reply

34 Job info subscribe

35 Job info 36 Job info acknowledge

37 Job info unsubscribe

38 Select Job

39 Job restart

40 Tool data upload request

1,2

41 Tool data upload reply

42 Disable tool

43 Enable tool

50 Vehicle ID number download

request

51 Vehicle ID number subscribe

1,2

52 Vehicle ID number

1,2

Has an option to

send w/without IDs

53 Vehicle ID number acknowledge

54 Vehicle ID number unsubscribe

60 Last tightening result data

1-6,999

subscribe

61 Last tightening result data 62 Last tightening result data

acknowledge

63 Last tightening result data

unsubscribe

64 Old tightening result upload

request

Supported MID

MID Description

Revisions Note

65 Old tightening result upload reply

70 Alarm subscribe

71 Alarm
72 Alarm acknowledge 73 Alarm unsubscribe

76 Alarm status

77 Alarm status acknowledge

80 Read time upload request

81 Read time upload reply

82 Set time 90 Multi spindle status subscribe

91 Multi spindle status

92 Multi spindle status acknowledge 93 Multi spindle status unsubscribe

100 Multi spindle results subscribe

101 Multi spindle results

102 Multi spindle results acknowledge 103 Multi spindle results unsubscribe

113 Flash green light on tool

127 Abort Job 128 Job batch increment 129 Job batch decrement 130 Job off
150 Identifier download request 157 Reset all Identifiers 200 Set external controlled relays

Only supports 0

(off) and 1 (on)

210 Status external monitored inputs

subscribe

211 Status external monitored inputs 212 Status external monitored inputs

acknowledge

213 Status external monitored inputs

unsubscribe

214 IO device status request 215 IO device status reply 216 Relay function subscribe

1,2 See supported

relay functions

217 Relay function 218 Relay function acknowledge 219 Relay function unsubscribe 241 User data subscribe

below. Out_1 - Pulse status

242 User data
243 User data acknowledge 244 Relay function unsubscribe

(0= OK, 1 = Low, 2 = High)
Out_2 - Pulses

Out_3 - Undefined

900 Trace data
9999 Keep alive open protocol communication

Out_4 - Undefined Trace type 1 &
2 only (angle & torque)

Supported Relay Functions

Supported Relay Functions

Number Function

1

OK

2

NOK

5

Low Torque

6

High Torque

7

Low angle

8

High angle

Supported Relay Functions

Number Function

9

Cycle complete

10

Alarm

11

Batch NxOK

12

Job OK

19

Tool ready

20

Tool start switch

Supported Relay Functions

Number Function

21

Dir. switch = CW

22

Dir. switch = CCW

26

Tool running

145

Start Trigger Active

276

Cycle abort

QUALITY · INNOVATION · SERVICE

CORPORATE HEADQUARTERS 10000 SE Pine Street Portland, Oregon 97216 Phone: (503) 254­6600 Toll Free: 1-800-852-1368

AIMCO CORPORATION DE MEXICO SA DE CV

Ave. Cristobal Colon 14529

Chihuahua, Chihuahua. 31125

LIT-MAN177_OPENPROTOCOL

Mexico

07-07-22

Phone: (01-614) 380-1010

©2022 AIMCO


Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Windows)