SereneLife Portable Air Conditioner User Guide

Models: SLPAC240W - SLPAC406W - SLPAC242B - SLPAC408B

About SereneLife

SereneLife products are designed to create a more comfortable living space, indoors and out. Our team presents innovative lifestyle solutions throughout the year that promote simplicity and serenity. We're committed to delivering the most dependable products so you can live a better, more serene life.

Features and Technical Specs

Features:

Technical Specs:

Before You Begin

Product Description

Our powerful portable air conditioners serve as excellent cooling solutions for single rooms, creating a comfortable atmosphere in your space. Additionally, they feature ventilation and dehumidifying functions to circulate air and remove moisture. These self-contained systems do not require any permanent installation, allowing you to move them to the space where they are most needed. They are commonly used in kitchens, temporary residences, computer rooms, garages, and other places where installing an Outdoor Unit is impractical. The environmentally friendly R32 is used as the refrigerant. R32 has no damaging influence on the ozone layer (Ozone Depleting Potential - ODP), a negligible greenhouse effect (Global Warming Potential - GWP), and is available worldwide. Due to its efficient energy properties, R32 is highly suitable as a coolant for this application. Special precautions must be taken into consideration due to the coolant's high flammability.

Symbols from the Unit and User Manual

For Your Safety

General Safety Precautions

FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY, AND PROPERTY DAMAGE.

Ensuring your safety is our utmost priority. Please read this manual carefully and ensure a complete understanding before operating your appliance.

Operational Precautions

WARNING: To reduce the risk of fire, electric shock, or injury to persons or property:

Safety Precautions on Servicing

WARNING: Any person involved in working on or breaking into a refrigerant circuit should possess a currently valid certificate from an industry-accredited assessment authority. This certificate authorizes their competence to handle refrigerants safely in accordance with an industry-recognized assessment specification.

WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repairs requiring the assistance of other skilled personnel shall be conducted under the supervision of an individual competent in the use of flammable refrigerants.

If you don't understand something or need help, contact the dealer services.

Checks to the area

Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to minimize the risk of ignition. Before conducting work on the refrigerating system, comply with the following precautions.

Work procedure

Work shall be undertaken under a controlled procedure to minimize the risk of flammable gas or vapor being present during the work.

General work area

All maintenance staff and others working in the local area shall be instructed on the nature of the work being carried out. Avoid working in confined spaces. Section off the area around the workspace. Ensure that the conditions within the area have been made safe by controlling flammable materials.

Checking for the presence of refrigerant

The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for flammable refrigerants, i.e., no sparking, adequately sealed, or intrinsically safe.

Presence of fire extinguisher

If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available at hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

No ignition sources

No person carrying out work related to a refrigeration system that involves exposing any pipework containing or having contained flammable refrigerant shall use any sources of ignition in a manner that may lead to the risk of fire or explosion. Keep all possible ignition sources, including cigarette smoking, sufficiently far away from the site of installation, repairing, removal, and disposal during which flammable refrigerant can possibly be released into the surrounding space. Before work takes place, survey the area around the equipment to ensure there are no flammable hazards or ignition risks. Display "No Smoking" signs.

Ventilated Area

Ensure that the area is open or adequately ventilated before breaking into the system or conducting any hot work. Maintain a degree of ventilation throughout the work period. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

Checks to the Refrigeration Equipment

When changing electrical components, ensure they are fit for the purpose and to the correct specifications. Always follow the manufacturer's maintenance and service guidelines. If in doubt, consult the manufacturer's technical department for assistance.

The following checks shall be applied to installations using flammable refrigerants:

Checks to Electrical Devices

Repair and maintenance of electrical components shall involve initial safety checks and component inspection procedures. If a fault exists that could compromise safety, no electrical supply shall be connected to the circuit until the fault is satisfactorily addressed. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be implemented. This should be reported to the equipment owner to ensure all parties are informed.

Initial safety checks shall include:

WARNING! Install the unit only in rooms exceeding 4 m². Avoid installing the unit in areas where inflammable gas may leak.

NOTE: The manufacturer may offer other relevant examples or additional information regarding the refrigerant odor.

Product Overview

Product Diagram

1. Control panel

2. Air outlet with adjustable louver

3. Front Panel

4. Air inlet with air filter

5. Recessed handle

6. Air Exhaust

7. Drain opening with sealing plug

8. Castor

Note: The appearance is provided for reference purposes only. For detailed information, please refer to the actual product.

Installation - Unpacking

Unpack the carton and remove the appliance and accessories. Check the device for any damage or scratches after unpacking.

Accessories:

Choose Your Location

WARNING! Install the unit only in rooms exceeding 4 m². Avoid installing the unit in areas where inflammable gas may leak.

NOTE: The manufacturer may provide other suitable examples or additional information about the refrigerant odor.

Attach the Exhaust Hose

The air conditioner requires venting outside to allow the exhaust air, containing waste heat and moisture, to escape the room. Do not replace or extend the exhaust hose, as it may decrease efficiency or, worse, result in the unit shutting down due to low back pressure.

  1. Step 1: Connect the hose connector to one end of the exhaust hose.
  2. Step 2: Connect the window kit adapter to the other end of the exhaust hose.
  3. Step 3: Extend the adjustable window kit to the length of your window. Connect the exhaust hose to the window kit.
  4. Step 4: Close your window to secure the kit in place. Ensure the window kit is held firmly in place, and use duct tape if necessary. It is recommended to seal off the gap between the adapter and the sides of the window for maximum efficiency.
  5. Step 5: Attach the hose connector to the exhaust air outlet of the unit.
  6. Step 6: Adjust the length of the flexible exhaust hose to ensure the distance between the unit and the window is more than 27.5 inches, and the height from the exhaust hose to the floor is more than 35.4 inches. Avoid bends in the hose. Place the AC near an electrical outlet.
  7. Step 7: Adjust the louver at the air outlet, and then switch on the unit.

Operation

Control Panel and Display

Function Keys and Indicators:

Remote Control

The remote control has buttons for POWER, MODE, SPEED, SWING, TEMP/HRS +/-, TIMER, SLEEP, and °C/°F.

Settings

Start-up and Shutdown

Operation Modes

The unit has four operation modes: Cool, Dehumidifier, Fan, Sleep. The unit's working temperature under cooling mode is 61°F-95°F.

A. Cooling Your Room:

Select the cool mode to lower the temperature in your room.

Note: The air conditioner stops if the room temperature is lower than the selected temperature.

B. Ventilating Your Room:

C. Drying Your Room:

Press the MODE button on the control panel or remote control, and the dry indicator lights up. The fan speed is unable to be selected. The user should connect the hose to the drain outlet at the bottom of the unit.

Note: In this mode, the fan speed switches over to low speed and cannot be selected.

D. Sleep Mode:

The sleep mode can be activated when in cool mode and heat mode.

In cool mode: After 1 hour, the preset temperature is increased by 2°F. After another hour, the preset temperature will again be increased by 2°F.

Timer Setting (1 hour - 24 hours)

The timer has two ways of operation:

Note: Pressing POWER will also exit the timer setting.

Automatic Defrost

At low room temperatures, frost may build up at the evaporator during operation. The unit will automatically start defrosting, and the POWER LED will blink.

The defrost control sequence is as follows:

  1. A. When the unit operates in the cooling and drying operation, and the ambient temperature sensor senses the evaporator coil temperature is below 30°F, after the compressor stops operating for 10 minutes or the coil temperature reaches 44°F, the unit restarts in cooling operating mode.
  2. B. When the unit operates in the drying operation, once the coil temperature sensor senses the temperature of the evaporator is below 104°F and the differential temperature between coil temperature and room temperature is below 66°F after the compressor operates for 20 minutes, the unit starts defrosting for 5 minutes, and the power indicator blinks.

Overload Protection

In the event of a power loss, there is a 3-minute delay to protect the compressor before it restarts.

Drainage

Manual Drainage

  1. When the machine stops after the water is full, please unplug the power plug. Note: Move the machine carefully to avoid spilling water from the water pan at the bottom of the body.
  2. Place the water container below the side water outlet behind the body.
  3. Unplug the water plug, and the water will automatically flow into the water container.

Continuous Drainage

The self-evaporating system utilizes collected water to cool the condenser coils for better efficiency. There is no need to empty the drainage tank during cooling operation, except in drying operation and high humidity conditions. The condensate water evaporates at the condenser and is expelled through the exhaust hose. For continuous or unattended operation in drying mode, please connect the provided drain hose to the unit. Condensate water will automatically flow into a bucket or drain by gravity.

To Avoid Water Spillage:

Cleaning and Care

Cleaning the Air Filter (Every Two Weeks)

Dust collects on the filter and restricts airflow. The restricted airflow reduces the efficiency of the system, and if it becomes blocked, it can cause damage to the unit. The air filter requires regular cleaning and is removable for easy maintenance. Do not operate the unit without an air filter, or the evaporator may be contaminated.

  1. Press the POWER button to switch off the unit and unplug the power cord.
  2. Remove the filter mesh from the unit.
  3. Use a vacuum cleaner to remove dust from the filter.
  4. Turn the filter over and rinse it under running water. Let the water run through the filter in the opposite direction of airflow. Set aside and allow the filter to air dry completely before reinstalling.

Cleaning Procedure:

  1. Switch off the unit and remove the air filters.
  2. Rinse the air filter under running water.

Warning: Do not touch the evaporator surface with bare hands, as it could cause injury to your fingers.

Cleaning Up of Refrigerant

General Measures

  1. Gas/vapor is heavier than air and may accumulate in confined spaces, particularly at or below ground level.
  2. Eliminate every possible source of ignition.
  3. Use appropriate personal protection equipment (PPE).
  4. Evacuate unnecessary personnel, isolate, and ventilate the area.
  5. Do not get in the eyes, on the skin, or clothing. Do not breathe vapors or gas.
  6. Prevent entry to sewers and public waters.
  7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors.
  8. Isolate the area until the gas has dispersed. Ventilate and gas test the area before entering. Contact competent authorities after a spill.

Troubleshooting

Symptom: The unit is not operating.

Inspection:

Solutions:

Symptom: The unit works with reduced capacity.

Inspection:

Solutions:

Symptom: Water Leakage.

Inspection:

Solutions:

Symptom: Excessive Noise.

Inspection:

Solutions:

Error Codes: E0, E1, E2, Ft

Symptom Inspection Solution
E0 Communication faults between the main PCB and display PCB. Check the wire harness of the display PCB for damage.
E1 Ambient temperature sensor failure Check the connection or replace it. To clean or replace the temperature sensor.
E2 Coil temperature sensor failures. Check the connection or replace it. To clean or replace the temperature sensor.
Ft Condensate water high level alarm. Empty the drain pan by removing the rubber plug.

Decommissioning

Storage

For long-term storage of the air conditioner unit, follow these steps to ensure proper decommissioning and preservation:

  1. Unplug the Unit: Disconnect the power supply by unplugging the unit from the electrical outlet.
  2. Remove Exhaust Hose and Window Kit: Take out the exhaust hose and window kit that were originally stored with the unit.
  3. Drain Remaining Water: Ensure that any remaining water in the unit is drained. Follow the recommended drainage procedure specified in the user manual.
  4. Clean and Dry the Filter: Remove the air filter and clean it. Let the filter dry completely in a shaded area.
  5. Re-install the Filter: After the filter is completely dry, re-install it in its designated position within the unit.
  6. Store Upright: Store the unit in an upright position. This helps prevent potential damage and ensures proper functioning when brought back into use.
  7. Preserve in a Suitable Environment: Store the air conditioner in a well-ventilated, dry, non-corrosive gas environment. Avoid exposure to extreme temperatures or humidity.
  8. Evaporator Drying: To prevent component damage and mold growth, it is recommended to dry out the evaporator inside the machine before storage. This can be done by either placing the unplugged unit in a dry open area for several days or by running the machine in low-wind ventilation mode until the drainage pipe becomes dry.
  9. Ensure Indoor Storage: Store the unit indoors in a safe and secure location.

Attention: Ensure the unit is completely dry before storage to prevent mold and component damage. Follow the recommended storage conditions to maintain the unit's functionality. If uncertain, refer to the user manual or contact the manufacturer for specific storage guidelines.

Disposal Instructions

WARNING: Releasing refrigerant into the atmosphere is strictly forbidden.

  1. Do Not Dispose as Unsorted Municipal Waste: Electrical appliances, including the air conditioner unit, should not be disposed of as unsorted municipal waste.
  2. Use Separate Collection Facilities: Utilize separate collection facilities for the disposal of electrical appliances. Contact your local government or waste management authorities to inquire about available collection systems.
  3. Follow Local Regulations: Comply with local regulations and guidelines for the disposal of electronic waste. Different regions may have specific protocols for handling and recycling electrical appliances.
  4. Prevent Environmental Damage: Avoid disposing of electrical appliances, including air conditioners, in landfills or dumps. Such disposal methods may lead to hazardous substances leaking into the groundwater, posing risks to the environment and the food chain.
  5. Contact Local Authorities for Information: Seek information from local government or environmental agencies regarding proper disposal methods and designated collection points for electronic waste.
  6. Protect Health and Well-being: Responsible disposal of electrical appliances is crucial to prevent hazardous substances from causing harm to health and well-being.

Note: Always adhere to local regulations and guidelines related to the disposal of electronic waste. Improper disposal can have detrimental effects on the environment and human health.

Register Product

Thank you for choosing SereneLife. By registering your product, you ensure that you receive the full benefits of our exclusive warranty and personalized customer support. Complete the form to access expert support and to keep your SereneLife purchase in perfect condition.

Visit: Serenelifehome.com/pages/register

Models: SLPAC240W, SLPAC406W, SLPAC242B, SLPAC408B, SLPAC240W Portable Air Conditioner, SLPAC240W, Portable Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 26 Pages, 8.16MB

PDF preview unavailable. Download the PDF instead.

SLPAC406W

References

Adobe PDF library 10.01 Adobe Illustrator CS6 (Windows)

Related Documents

Preview SereneLife Portable Air Conditioner User Guide
User guide for the SereneLife Portable Air Conditioner, covering features, safety, installation, operation, and maintenance.
Preview SereneLife Portable Air Conditioner User Guide
User guide for the SereneLife Portable Air Conditioner, detailing features, safety precautions, installation, operation, and maintenance.
Preview SereneLife Portable Air Conditioner User Guide
Comprehensive user guide for the SereneLife Portable Air Conditioner, covering features, safety precautions, installation, operation, cleaning, and troubleshooting.
Preview SereneLife Portable Air Conditioner User Guide
Comprehensive user guide for the SereneLife Portable Air Conditioner, covering features, safety precautions, installation, operation, cleaning, and troubleshooting.
Preview SereneLife Portable Air Conditioner User Guide
User guide for the SereneLife Portable Air Conditioner, covering features, safety, installation, operation, and troubleshooting.
Preview SereneLife SLACP12 Single Duct Portable Air Conditioner User Guide
User guide for the SereneLife SLACP12 Single Duct Portable Air Conditioner, covering features, technical specifications, safety instructions, installation, maintenance, and troubleshooting.
Preview SereneLife SLPAC14 Portable Air Conditioner User Guide
Comprehensive user guide for the SereneLife SLPAC14 Portable Air Conditioner, covering features, operation, installation, maintenance, and troubleshooting.
Preview SereneLife SLPAC105W Portable Air Conditioner User Guide
Comprehensive user guide for the SereneLife SLPAC105W Portable Air Conditioner, covering setup, operation, maintenance, troubleshooting, and smart features.