FSP Switching Power Adapter Compliance Verification
FSP Group Inc.
Document Details
Model Name/Type | FSP030-DHAN3, FSP036-DHAN3, FSP040-DHAN3 |
Trade Mark | FSP |
Safety Type | EMC/Multimedia Equipment |
Document Number | SFD-00001561 |
SFA Number | SFA22011152 |
Issue Date (Internal) | 2022/05/16 |
Issue Date (Verification) | April 18, 2022 |
Test Report Number | TMXD2202000821DE |
Verification of Compliance
Applicant: FSP Group Inc.
Address: No. 22, Jianguo East Road, Taoyuan City, Taiwan 330, R.O.C.
Product: Switching Power Adapter
Model/Type: FSP030-DHAN3
Added Models: FSP036-DHAN3, FSP040-DHAN3
Applicable Standards
- EN 55032: 2015/A11:2020 + A1: 2020
- CISPR 32: 2015 (Ed 2.0) / C1: 2016
- AS/NZS CISPR 32: 2015
- BS EN 55032: 2015/A11:2020 + A1: 2020
- EN IEC 61000-3-2: 2019/A1: 2021
- BS EN IEC 61000-3-2: 2019/A1: 2021
- EN 61000-3-3:2013/A2: 2021
- BS EN 61000-3-3: 2013/A2: 2021
- EN 55035: 2017/A11: 2020
- BS EN 55035: 2017/A11: 2020
- IEC 61000-4-2: 2008
- IEC 61000-4-3: 2006 + A1: 2007 + A2: 2010
- IEC 61000-4-4: 2012
- IEC 61000-4-5: 2014 + A1: 2017
- IEC 61000-4-6: 2013 + COR1: 2015
- IEC 61000-4-8: 2009
- IEC 61000-4-11:2004 + A1: 2017
Test Laboratory
Name: Compliance Certification Services Inc.
Lab Location: Xindian Lab, No. 163-1, Jhongsheng Rd., Xindian Dist., New Taipei City, Taiwan
Conclusion
Based upon a review of the Test Report(s), the tested sample of the product mentioned above is deemed to comply with the requirements of the above standards.
Note: This verification is only valid for the product and configuration described and in conjunction with the test report as detailed above.