Dr. Pen M8 User Manual
Please read this manual carefully before using your Dr. Pen M8 Auto Microneedle System.
Parts Name
The Dr. Pen M8 is an Auto Microneedle System. Key parts include:
- Power Interface: Port for connecting the power adapter.
- Speed Display Screen: Digital display showing the current speed setting.
- Power/Speed Button: Used to turn the device on/off and adjust speed.
- Scale Adjustment Ring: Located on the pen body, used to adjust needle depth.
- Needle Cartridges: Replaceable cartridges that attach to the pen tip.
A diagram shows the Dr. Pen M8 device, highlighting the Power Interface, Speed Display Screen, Power/Speed Button, Scale Adjustment Ring, and Needle Cartridges.
How to Operate
Model Types
Wireless Model: Dr pen M8-W
The instrument can be used with its built-in battery or AC power.
Wired Model: Dr pen M8-C
The instrument is used with AC power only.
Charging the Battery
1. Plug the DC adapter into the device's jack.
2. Plug the DC adapter into an AC outlet.
3. Connect the adapter to the power interface to charge the battery.
Charging Status Indicator:
The power indicator stays red while charging.
The power indicator turns green after charging is completed.
Preparation and Device Start
1. Take out a needle cartridge from its sterilized packaging.
2. Fit the slot of the cartridge into the pen correctly, then push the needle cartridge horizontally up to the end.
3. Lock the needle cartridge by turning it counterclockwise.
4. To remove the cartridge, turn it clockwise and then pull out horizontally. (Refer to Fig 1 diagram).
Fig 1 Description:
A diagram illustrates the cartridge attachment process, showing a U-shaped point on the needle cartridge that must align with the handpiece point during assembly or disassembly.
Attention: Before assembling or disassembling, ensure the U-shaped point of the needle cartridge is aligned with the point of the handpiece.
Important: In order to protect the pen, do not invert the instrument to prevent liquid backflow.
Starting and Shutting Down the Device
Press the power button for 2-3 seconds to start or shut down the device.
Adjustment of Needle Length
Adjust the depth of the needle by turning the scale adjustment ring. The depth should be adjusted after the pen is started.
Turn the ring clockwise: needle depth will be shorter.
Turn the ring counterclockwise: needle depth will be longer.
Needle Depth Visual Description:
A visual shows the pen with arrows indicating that turning the scale adjustment ring clockwise shortens the needle depth, while turning it counterclockwise lengthens it.
Speed Display and Adjustment
Speed Display:
A digital display shows speed settings from 1 to 6.
6 Speeds Adjustment:
The pen operates from low to high speed. The speed changes each time the power/speed button is pressed.
Needle Cartridge Introduction
The Dr. Pen M8 is compatible with various needle cartridges:
- 11 Needles
- 16 Needles
- 24 Needles
- 36 Needles
- 42 Needles
- RNANO Needles
- SNANO/3DNANO Needles
- 5DNANO Needles
Images display the different types of needle cartridges, each labeled with its needle count or type.
Specification
- Product Name: Auto-stamp Motorized Meso Machine
- Model Name: Dr pen M8
- Adapter: 5V-1000mA
- Package Weight: Approximately 333g
- Package Size: 169*123*56mm
Packing List
| Item | Quantity |
|---|---|
| Hand Piece | 1 pc |
| Adapter | 1 pc |
| Manual | 1 pc |
| Power Cable | 1 pc |
| Needle Cartridge | 20 pcs |
Precaution
Please be sure to read instructions before use and follow as described.
Do not apply it to the man as follows:
- 1. Who has acute disease or bloody disease over 38°C
- 2. Who has allergy and hemophilia
- 3. Who has melanosis of the face
- 4. Who has high internal heat
- 5. Who regularly visits hospital
- 6. Who takes medicines
- 7. Who is under 12 years old
General Precautions:
- [Prohibited] Do not use it on the power other than AC 220V. It may cause fires or malfunction.
- [Prohibited] Do not use it near the place with high temperature, dust or humidity (Near the humidifier). It may cause malfunction.
- [Prohibited] Do not repair, disassemble or alter the controller and the body. It may cause malfunction.
- [Prohibited] Do not touch the device or detach the power cords with wet hands. It may cause electric shock.
- [Prohibited] Do not use the stripped cord or propped cord. It may cause fires (Be sure to replace it with another).
- [Prohibited] Do not use the propped cord which has crack or scares. It may cause scares on the skin.
- [Prohibited] When you don't use it for a long time, unplug it from the outlet.
- [Warning] Be sure to have an inspection for test. If any troubles are found, get it repaired.
- [Prohibited] No one other than the operator can touch it. It may cause accidents or malfunction.
Device Markings:
- [AC] Alternating current
- [DC] Direct current
- [CE] CE mark
- [Attention] Attention, consult accompanying documents
- Manufacturer
- Date of manufacture
- [Floating Part] Floating applied part
Warranty
The warranty period of this device is 24 months. We offer repair for our products from the day they are purchased. If any of our products has damages or natural trouble, we offer repair or replacements.
General Maintenance
Make sure to inspect the device and adapter before use.
Keep the device with its power off. Wipe its surface with a dry cloth.
Keep it away from direct sunlight or high temperature and humidity.
Do not leave the measurement, repair, or alteration of the device to non-professional staff.
When you use the device which has not been used for a long time, make sure to check if it works properly with safety.