BROANTM Fresh In Basic
FIN-180B; see table for available part numbers.
30-180 CFM at 0.2 in. w.g. 30-170 CFM at 0.4 in. w.g.
The Broan Fresh In series is a quiet and effective supply air solution for hot and mixed climates, offering renewed fresh air comfort. It offers the greatest reduction of HERS score compared to CIFS solutions. Thanks to their ECM motors, the Basic FIN-180B and FIN-180B-HW models deliver energyefficient continuous ventilation at a constant airflow in typical installations. Designed to be the most versatile, reliable and energy-efficient supply fan on the market, it can also be installed horizontally, vertically, upside down, or flush to the ceiling. Two models are available: with a power cord or hardwired.
Mechanical components
· High efficiency ECM motor · Constant airflow blower designed to maintain the selected airflow
in standard installations · Silent ventilation with balanced metallic dual inlet blower wheel · Spring loaded damper · Blower efficiency as high as 12.4 CFM/W · Protection grille for blower
Electronic features
· Adjustable speed from 30 to 180 CFM in 10 CFM increments
Installation features
· Five installation possibilities: ceiling hung, flush to ceiling, attic mounted, ceiling mounted and wall mounted
· Paintable door and frame · Compact and designed to fit between 12-in. cc joists · 6-in. diameter ports with integrated test ports and bumps to
maintain tie-trap in place · 6-ft. power cord (FIN-180B) or hardwired (FIN-180B-HW) · Easy maintenance: can be done within 5 minutes through the
access door

FIN-180B
6-ft. power cord

VB0260
Options

FIN-180B-HW
Hardwired

Description

Part no.

9.25" x 9.25" x 2" MERV 8 filter

FIN- MERV8

9.25" x 9.25" x 2" MERV 13 filter

FIN-MERV13

Paintable decorative finishing trim for discreet FIN-R1015 installation

Installation bracket, including hardware, for

FIN-S1624

installation between joists of 16-in. cc and 24-in. cc

Warranty
The BROANTM Fresh In Basic is protected by a 5-year warranty on parts only.
Requirements and standards

When properly installed and set, this unit will meet requirements of:
· EPA Indoor airPLUS, Version 1 · 2012 & 2015 IECC, Version 2018 · 2012 & 2015 IRC, Version 2018 · ENERGY STAR Certified Homes, Version 3 · ASHRAE 62.2-2010 & 62.2-2016

· Characteristics

Power Weight Shipping weight Ports diameter Width Length Height Min. operating temperature

FIN-180B FIN-180B-HW 6-ft. power cord Hardwired
11 lb. 14.5 lb.
6 in. 10 ¼ in. 14 ¾ in. (without ports) 10 in.
14 °F

Mounting options

Can be installed as a stand alone unit or connected to the return ducting of an AHU.

Ceiling Hung

Attic Mounted

Under Ceiling

12"

10"

Flush to Ceiling
12"

VH0153A

VD0466

14¼" clearance

10¼"
VH0154

VD0467 With optional decorative trim

Wall Mounted
10" 10"

Electricity Consumption

MERV 13 Main Filter

Airflow setting (CFM)
Static Pressure (in. w. g.) Power (Watts)
Efficiency (CFM/Watts)
Power (Watts) Efficiency (CFM/Watts)
Factory Setting: 80 CFM
120 VAC, 60 Hz, 0.7 Amp
Installation Zones

30
0.1 0.2 4.8 6.8 6.3 4.4 5.2 7.2 5.8 4.2

VH0152

60
0.1 0.2
7.0 8.9

90

120

180

0.1 0.2 0.4 0.1 0.2 0.4 0.1 0.2 0.4

7.8 10.8 19.0 9.7 14.4 22.5 22.0 27.0 37.7

8.6 6.7 11.5 8.3 4.7 12.4 8.3 5.3 8.2 6.7 5.3

7.4 10.8 11.3 15.2 22.7 17.0 21.2 N/A 32.5 37.0 N/A

8.1 5.6 8.0 5.9 4.0 7.1 5.7 N/A 5.5 4.9 N/A

VN0011A

Installation allowed in zones 1-4. Refer to the installation instructions for more details.

Fan Curve Examples
Airflow adjustable from 30 to 180 CFM in 10 CFM increments.

Fan curve examples with main filter
0.7

Fan curve examples with MERV 8 filter
0.6

Pressure (in w.g.) Pressure (in w.g.)

0.6

0.5

0.5 0.4
0.4 0.3
0.3
0.2 0.2

0.1

0.1

0 0 20 40 60 80 100 120 140 160 180 200
Airflow (CFM)

0 0 20 40 60 80 100 120 140 160 180 200
Airflow (CFM)

Insulated door Damper assembly

14¼"

Unit setting

Pressure (in w.g.)

Pressure (in w.g.)

Fan curve examples with MERV 13 filter
0.6
0.5
0.4
0.3
0.2
0.1
0 0 20 40 60 80 100 120 140 160 180 200
Airflow (CFM)
Fan curve examples with MERV 16 filter
0.6
0.5
0.4
0.3
0.2
0.1
0 0 20 40 60 80 100 120 140 160 180 200
Airflow (CFM)
MERV 16 filters are not available through Broan. Performance may vary according to brand.

Blower motor

Blower wheel

Insulated housing

Product specifications are subject to change without notice.

Test port

Test port Electronic board
Filter

A&E Specs
Performance Requirements · Unit's blower shall be designed to maintain a constant airflow in typical installations · Unit speed shall be selectable from 30 to 180 CFM in 10 CFM increments. · Backdraft damper shall have a magnet to prevent flickering and stay closed during door blower test. · Unit's blower efficiency shall be at least 8.3 CFM/W at 120 CFM, 0.2 in. w.g. · Unit shall be equipped with test ports to allow airflow measurement. · Unit shall have an access door that allows quick and easy maintenance of all parts.
Construction Requirements · Blower wheel shall be metallic. · Unit shall have an ECM motor. · Backdraft damper shall be integrated to the unit. · The unit's blower shall be protected by a grille. · Filter shall be accessible without a tool. · Unit's housing and door shall be paintable and made of 24 ga galvannealed steel. · Unit shall include a washable metallic filter. · Unit shall allow 2-in. thick MERV filters in option. · Unit's width shall not exceed 10.25". · Unit's height shall not exceed 10". · Unit's housing's length shall not exceed 14.75". · Unit's weight shall not exceed 12 pounds.
Quality Requirements · All plastic parts in the airflow shall be UL94 HB fire rated. · Electrical enclosure shall be in plastic to prevent condensation and UL94 5VA fire rated. · Unit's housing shall be insulated and not show any thermal bridge to the metallic housing. · Unit's insulation shall be made of expanded polystyrene and UL94 HF-2 fire rated. · Unit conforms to UL 507 requirements including those for appliances for use in "other spaces used for environmental air"
(Sections 212 - 214) in conformity with the National Electric Code Article 300.22 (c)(3). (applies to FIN-180B-HW model only) · Unit shall be protected by a 5-year warranty. · Unit shall be ENERGY STAR and HVI rated. · Unit shall be ASHRAE 62.2-2010 and 2016 IRC/IMC compliant. · Unit shall be certified by an independent laboratory. · Manufacturer shall be ISO 9001-2015. · Manufacturing plant shall be located in North America.
Installation requirements · Unit shall fit between 12-in. cc joists. · Unit shall be designed to be connected with central ventilation or to be used in a standalone installation. · Unit shall be suitable for ceiling hung, ceiling mounted, attic mounted, wall mounted and flush-to-ceiling installation. · Unit shall be designed to be installed in any orientation. · Unit's ports shall be 6-in. round with bumps to maintain a tie-wrap in place.
FIN-180Bd062022

