Owner's Manual for MEAN WELL models including: UHP-500-4.2, UHP-500-5, UHP-500-12, UHP-500-15, UHP-500-24, UHP-500-36, UHP-500-48, UHP-500-55, UHP-500 Series 500W Slim Type with PFC Switching Supply, 500W Slim Type with PFC Switching Supply, Type with PFC Switching Supply, PFC Switching Supply, Switching Supply
UHP-500-24 MEAN WELL - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 6 Pages, 759.54KB
DocumentDocument500W Slim Type with PFC Switching Supply UHP-500 series User's Manual Video GB 4943.1 UL62368-1 Bauar t gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 BS EN/EN61558-1 BS EN/EN61558-2-16 IEC62368-1 IEC61558-1 IEC61558-2-16 Note 10 -~+ Industrial automation machinery Industrial control system Mechanical and electrical equipment Electronic instruments, equipments or apparatus LED display application Power Source Equipment for PoE(55V model) R File Name:UHP-500-SPEC 2024-12-30 Downloaded from Arrow.com. 500W Slim Type with PFC Switching Supply UHP-500 series SPECIFICATION MODEL UHP-500 -4.2 UHP-500 -5 UHP-500 -12 UHP-500 -15 UHP-500 -24 UHP-500 -36 UHP-500 -48 UHP-500 -55 DC VOLTAGE 4.2V 5V 12V 15V 24V 36V 48V 55V RATED CURRENT 80A 80A 41.7A 33.4A 20.9A 13.9A 10.45A 8.9A RATED POWER 336W RIPPLE & NOISE (max.) Note.2 200mVp-p 400W 200mVp-p 500.4W 501W 501.6W 200mVp-p 200mVp-p 240mVp-p 500.4W 501.6W 500W 360mVp-p 360mVp-p 500mVp-p OUTPUT VOLTAGE ADJ. RANGE Note.7 3.6~4.4V 4.5~5.5V 11.4~12.6V 14.3~15.8V 22.8~25.2V 34.2~37.8V 45.6~50.4V VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.3% ±0.3% ±0.3% ±0.3% ±0.3% LOAD REGULATION ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time 45~58V ±1.0% ±0.3% ±0.5% HOLD UP TIME (Typ.) 12ms/230VAC 12ms/115VAC VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF0.95/230VAC PF0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 89% 90% 94% 94% 94.5% 95% 95% 95% AC CURRENT (Typ.) 4.85A/115VAC 2.6A/230VAC INRUSH CURRENT (Typ.)Note9 Cold start 30A/115VAC LEAKAGE CURRENT <0.75mA / 240VAC 60A/230VAC OVERLOAD 110~140% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE 4.62 ~ 5.46V 5.75 ~ 6.75V 13.2 ~ 15.6V 16.5 ~ 19.5V 26.4 ~ 31.2V 39.6 ~46.8V 52.8 ~ 62.4V 60 ~ 69V Protection type :Shut down O/P voltage,re-power on to recover FUNCTION OVER TEMPERATURE DC OK SIGNAL(Optional) REDUNDANT(Optional) Protection type :Shut down O/P voltage, recovers automatically after temperature goes down Contact rating(max.):30Vdc/1A resistive load For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically enabled. This can prevent the system crash, and provide the reliability of system WORKING TEMP. -30 ~ +70(Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS SAFETY & UL 62368-1,TUV BS EN/EN62368-1,BS EN/EN60335-1(Except for 55V), BS EN/EN61558-1,BS EN/EN61558-2-16, GB 4943.1, BSMI CNS15598-1, EAC TP TC 004 approved;Design refer to AS/NZS 61558.1/2.16, AS/NZS 62368.1 EMC WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC (Note.6) ISOLATION RESISTANCE I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25/ 70%RH EMC EMISSION EMC IMMUNITY Compliance to BS EN/EN55032,GB17625.1,GB/T 9254.1,Class B, BS EN/EN61000-3-2,-3, BSMI CNS15936, EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level ,EAC TP TC 020 MTBF 1264.1 K hrs min. Telcordia SR-332 (Bellcore) ; 167.6K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 232*81*31mm (L*W*H) PACKING 0.905kg; 16pcs/15.48kg/0.82CUFT NOTE The The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:UHP-500-SPEC 2024-12-30 500W Slim Type with PFC Switching Supply Block Diagram EMI FILTER I/P & RECTIFIER FG PFC CIRCUIT POWER SWITCH- ING O.T.P. O.L.P. CONTROL UHP-500 series RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. PFC fosc:60KHz PWM fosc:65KHz~75KHz +V -V Derating Curve DC OK Function Redundant Function 12V,15V 100 others 80 4.2V,5V 60 40 20 -30 0 10 20 30 40 45 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () RATED CURRENT (%) 230Vac for 12V,15V 100 230Vac for other 90 230Vac for 4.2V,5V 80 110Vac for other 70 230Vac for 55V 60 110Vac for 4.2V,5V 50 40 30 20 110Vac for 55V -30 0 10 20 30 40 45 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE() RATED CURRENT (%) RATED CURRENT (%) 100 80 60 40 20 -30 0 10 20 30 40 50 60 70 80 90 (HORIZONTAL) Tcase () Downloaded from Arrow.com. File Name:UHP-500-SPEC 2024-12-30 LOAD (%) 500W Slim Type with PFC Switching Supply STATIC CHARACTERISTIC 100 90 80 70 60 50 40 90 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz DC OK Relay Contact Contact Close Contact Open Contact Rating(max.) PSU turns on/DC ok PSU turns off/DC fail 30Vdc/1A resistive load UHP-500 series Redundant function (1) UHP-500R is built-in redundant function and can be connected 2 units in parallel . (2) When in parallel operation the maximum load should not be greater than the rated power of any PSU. +V PSU -V +V -V LOAD +V PSU -V Downloaded from Arrow.com. File Name:UHP-500-SPEC 2024-12-30 500W Slim Type with PFC Switching Supply UHP-500 series Mechanical Specification CASE NO.:233D Unit:mm Tolerance:±1 9 81 63 7.62 15.5 TB1 3 2 1 232 226 3 tc tc : Max. Case Temperature 1 TB3 9.0 2 3 TB2 4 CN1 21 SVR 4-4.2 116 31 AC Input Terminal(TB1) pin NO. Assignment Pin No. Assignment Terminal Max mounting torque 1 AC/L 2 AC/N (DEGSON) DG28C-B-03P 5Kgf-cm 3 DC OK Connector(CN1):JST B2B-PH-K-S or requivalent Pin No. Assignment Mating Housing Terminal 1 DC COM1 JSTPHR-2 JSTSPH-002T-P0.5S 2 DC COM2 or requivalent or requivalent DC Output Terminal(TB2,TB3) pin NO. Assignment Pin No. Assignment Terminal Max mounting torque 1,2 -V (MW) 3,4 +V MEL-400-02P 8Kgf-cm Downloaded from Arrow.com. File Name:UHP-500-SPEC 2024-12-30 500W Slim Type with PFC Switching Supply UHP-500 series Installation 1.Operate with additional aluminum plate In order to meet the"Derating Curve"and the "Static Characteristics" ,UHP-500 series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and UHP-500 series must be firmly mounted at the center of the aluminum plate. unit:mm 450 M3*4 3 450 Downloaded from Arrow.com. File Name:UHP-500-SPEC 2024-12-30