Sub-Zero ICBID-RP Integrated Drawer Refrigerator Technical Data
service.subzero.com
ICBID-30RP TECHNICAL DATA
IMPORTANT NOTE: Always check the serial tag for exact refrigerant charge.
IMPORTANT NOTE: Always check the parts price list for possible compressor substitutions.
TIP: The freezer evaporator thermistor is used for the adaptive defrost on this model. The defrost terminator is used for temperature protection.
ICBID-30RP - AIR FLOW
For proper airflow, evaporator fan blades must be pushed onto the fan motor shafts fully, so that the motor shafts touch the fan blade stop point.
Data Point | Value |
---|---|
Refrigerator Charge | 45.4 grams |
Normal operating pressure low side (at max speed) | 10 inHg to 5 psig |
Normal operating pressure high side (at max speed) | 40 psig to 60 psig |
Compressor Type | Variable Speed |
Original compressor amps (at max speed) | 2.1 |
Original compressor BTU/H | 460 |
Defrost method | Fan Assisted Off Cycle Defrost |
Thermistor resistance at 0°C | 30,000 - 33,000 ohms |
Condenser Fan | 12 VDC 0.51 Amps 6.1 Watts 23.5 Ohms |
Evaporator Fan | 12 VDC 0.52 Amps 6.2 Watts 23.1 Ohms |
Air Purification Fan | 12 VDC 0.04 Amps 0.48 Watts |
INTEGRATED REFRIGERATION ERROR CODES
Error codes, or faults are logged when electrical errors are detected. Integrated error codes provide a 3-part identifier to indicate the device/system where the error occurred, the zone where the device/system error occurred and the failure associated with the error. The way an error is presented (door open or closed, alarm / no alarm, visible to consumer/only visible in diagnostic mode) indicates the error severity.
TIP: For example, error indicator 10 3 01 is a thermistor fault in Zone 3 where the device is shorted or closed. This error is Low Severity so it only shows on a splash screen to the user when the door is open without a chime; the error is logged in the service and user menus.
Device or System Fault Code | Zone | Failure Indicator |
---|---|---|
10 | 3 | 01 |
ERROR SEVERITY
Severity | Definition |
---|---|
1 - Lowest | Error visible only in the service menu, no indication to user, no chime |
2 - Low | Error visible on splash screen to user with door open and logged in service and user menu, no chime |
3 - Medium | Error steady on screen to user with door open and logged in service and user menu, no chime |
4 - Medium high | Error steady on screen to user with door open and logged in service and user menu, chime with door open |
5 - Critical | Error steady on screen to user with door open and logged in service and user menu, chime with door closed |
Integrated Refrigeration Error Codes (continued)
Fault Code | Device or System | Failure | Description |
---|---|---|---|
10 | Thermistor | 00 | Open |
15 | Relay | 01 | Short / closed |
20 | Defrost heater | 02 | Unstable |
30 | Ice / Water / Accessory | 05 | Miswire normal temps |
35 | Fan | 06 | Miswire overheat |
40 | Runtime | 07 | Bad ohms |
44 | Glass heater | 09 | Too warm / large temp differential |
45 | Lighting | 10 | Second device open |
50 | Flow meter | 11 | Second device short / closed |
60 | Load / component | 12 | Second device unstable |
90 | Control | 20 | Third device open |
95 | Diagnostic | 21 | Third device short / closed |
98 | Power | 22 | Third device unstable |
25 | Diagnostics failure | ||
30 | Valve enabled too long | ||
33 | Speed setting too low | ||
34 | Speed setting too high | ||
35 | Fan speed error | ||
36 | Fan current too low | ||
37 | Fan current too high | ||
38 | FET power output fault | ||
39 | DC output fault | ||
40 | Excessive runtime | ||
42 | Primary heater fault | ||
43 | Secondary heater fault | ||
44 | Door heater output fault | ||
45 | Burned out light | ||
46 | No position / state detected | ||
50 | Open heater | ||
55 | Triac open | ||
56 | Triac short | ||
60 | No load / load open | ||
65 | Stuck at dispenser water valve out | ||
66 | Stuck at ice water valve out | ||
70 | Bad flash write | ||
71 | Flash initialized | ||
72 | Flash memory bad | ||
73 | Flash memory not present | ||
74 | Invalid E2 checksum | ||
75 | Invalid model E2 checksum | ||
80 | No communication | ||
81 | Communications timeout | ||
82 | Partial communications | ||
83 | Bad micro communication |
Code | Zone |
---|---|
0 | Misc |
1 | Zone 1 |
2 | Zone 2 |
3 | Zone 3 |
4 | Defrost system |
5 | Control system |
6 | Compressors |
7 | Ambient |
8 | Ice maker |
9 | Dispenser |
A | Air filter |
L | Lighting |
U | Water system |
H | High voltage system |
C | Condenser |
b | Baffle |
Failure | Description |
---|---|
84 | Micro initialization |
85 | Display failure |
86 | Flow too slow |
87 | No flow |
90 | Framing errors |
92 | Excessive collisions |
93 | Data overrun |
95 | FMEA error |
96 | Calibration or low signal error |
97 | Quantum SPI |
98 | Brownout |
99 | Other |
File Info : application/pdf, 3 Pages, 299.37KB
DocumentDocumentReferences
iTextSharp™ 5.5.5 ©2000-2014 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.5 ©2000-2014 iText Group NV (AGPL-version)Related Documents
![]() |
Sub-Zero ICBID-RP Integrated Drawer Refrigerator Wiring Diagrams Detailed wiring diagrams and board summary for Sub-Zero ICBID-RP Integrated Drawer Refrigerators, including models ICBID-24R, ICBID-27R, ICBID-30RP, and ICBID-36R. Covers high voltage and low voltage connections, component identification, and control board summaries. |
![]() |
Sub-Zero ICBID-24RO Troubleshooting Guide Comprehensive troubleshooting guide for Sub-Zero ICBID-24RO appliances, covering error codes, component testing, and sealed system diagnostics. |
![]() |
Sub-Zero ICBID-RP Integrated Drawer Refrigerator Sealed System Service Information This document provides detailed service information for the sealed system of the Sub-Zero ICBID-RP Integrated Drawer Refrigerator, focusing on R600a refrigerant handling, safety precautions, and the operational flow of the sealed system components. |
![]() |
Sub-Zero Integrated Series (Drawers) Troubleshooting Guide A comprehensive troubleshooting guide for Sub-Zero Integrated Series drawers, detailing error codes, fault descriptions, and recommended actions. Includes sealed system diagnostics and pressure tables. |
![]() |
Sub-Zero ICBID-30CI 76cm Panel Ready Refrigerator Freezer Drawers with Ice Maker - Specifications & Features Detailed specifications, features, and installation dimensions for the Sub-Zero ICBID-30CI 76cm panel-ready refrigerator and freezer drawers with an automatic ice maker. Learn about its capacity, electrical requirements, and integration into custom cabinetry. |
![]() |
Sub-Zero ICBBI-42UFDID Troubleshooting Guide A comprehensive troubleshooting guide for the Sub-Zero ICBBI-42UFDID built-in refrigerator, detailing fault codes, general troubleshooting steps, and component testing procedures. |
![]() |
Sub-Zero ICBIC-24C Troubleshooting Guide A comprehensive troubleshooting guide for the Sub-Zero ICBIC-24C refrigerator, detailing error codes, their descriptions, severity, and recommended actions, along with thermistor and fan testing procedures. |
![]() |
Sub-Zero 700-3 Series Troubleshooting Guide: Error Codes and Solutions Comprehensive troubleshooting guide for Sub-Zero Integrated 700-3 BASE Series appliances, covering error codes, diagnostic procedures, and common operational issues. |