Tuya Smart Fingerprint Lock User Manual
Product List
- Front lock x 1
- Rear lock x 1
- Installation package x 1
- Certificate x 1
- Instructions x 1
Right and Left Commutation Regulation
2.1. Right and Left Commutation Regulation
To adjust the lock's orientation, click the "Video intercom - Room-to-Room Calling" icon and enter the call volume.
Diagram shows two lock panels, front and rear. Each panel has a 'Reversing screw' located near the handle mechanism. The text indicates that a screwdriver is used to remove this screw, the handle is turned 180 degrees counterclockwise for reversal, and the screw is then re-tightened on the opposite side.
2.2. Lock Body Oblique Tongue Commutation
Diagram illustrates the adjustment of the lock's oblique tongue. The steps are:
- Lift the reversing pick.
- Oblique tongue presses into lock body, then flip it 180 degrees.
- The oblique tongue is turned over and the penetrated lock body is reversed.
Installation Procedure
3.1. Lock body installation
Diagram depicts the installation of the lock body onto a door. It shows the door edge, the lock body with its bolt mechanism, the lock cylinder, a 'lock core screw', and general 'screws'. The text describes opening holes, inserting the lock body, and then inserting and securing the lock core with the lock core screw.
3.2. Install front lock components
Diagram illustrates the attachment of the front lock components. It shows the 'front panel assembly', a 'square bar' passing through it, a 'cotter pin' securing the square bar, and a 'stud assembly'. Arrows indicate 'Direction inside the door' and 'Outside the door'. The steps are:
- Insert one end of the square rod with a small hole into the rod hole above the front panel assembly. Insert the cotter pin to secure the square rod. Bend the exposed part of the cotter pin with pliers to prevent looseness.
- Twist the stud into the teeth on the front plate assembly and tighten it.
- Pass the front pair wire through the door hole from outside to inside, and pass the square rod through the square rod hole of the lock body.
3.3. After installation of plate components
Diagram shows the rear panel assembly and its connection to the front. Components labeled include 'rear panel assembly', 'rear cover plate', 'front to front connection', 'square bar', and 'M5 screws'. The steps are:
- Press down on the pressure switch pattern on the back cover plate, spring up the back cover plate, and pull it up.
- Insert the front-to-back cable into the corresponding socket in the rear lock assembly.
- Align the handle square hole of the rear lock assembly with the square rod. Align the lock ruler with the upper hole of the lock body, and install the rear lock on the door. If the square rod and lock ruler are too long, they should be cut to a suitable length. Arrange and place the main line in the door hole to avoid crushing it.
- Pass two M5 screws through the rear panel assembly, align them with the front lock stud screw holes, and twist the screws in. Tighten slightly and test if the handle and knob are smooth. If not, adjust the rear panel assembly.
- Insert the battery, align the bottom pin of the rear cover with the buckle, and press the pressure switch pattern to fasten the rear cover to the rear panel assembly.
3.4. Fingerprint needs to be input from multiple angles
Diagram displays a fingerprint scan area with directional arrows pointing to different sections of the fingerprint (e.g., top, bottom, left, right, center). This visually represents the instruction to input the fingerprint from multiple angles for optimal recognition.
3.5. Function and operation
- Administrator information: refers to the administrator's fingerprint, password, or IC card.
- Unlocking information: refers to the entered fingerprint, password, or IC card information (including administrators and ordinary users).
- "*" key: serves as the clear key or back key.
- "#" key: is the confirmation key.
- In the initial state, any fingerprint, IC card, or six-digit or longer password can unlock the device.
- After administrator information is entered, only registered fingerprints, IC cards, or passwords can unlock the device.
- Access to door lock function management.
Operational Guidelines
4.1. Operational Guidelines
Please enter the administrator information (default: 123456).
- Administrator Settings: Press 1 for configuration, Press 2 to delete.
- User Settings: Press 1 for configuration, Press 2 to delete.
- System Settings:
- Time setting: Press 1 to set time (e.g., modify year, month, day, hour, minute).
- Voice selection: Press 2 for Chinese, Press 1 for English.
- Volume adjustment: Press 3 for volume levels (1: Low, 2: Medium, 3: High, 4: Mute).
- Normally open setting: Press 4 (1: Start normally open, 2: Close normally open).
- Dual authentication mode: Press 5 (1: Enter dual authentication mode, 2: Cancel dual authentication mode).
- Anti-prying setting: Press 6 (1: Start, 2: Close).
- Record query: Please press 7.
- Networking Settings:
- 1. Start networking configuration.
- 2. Turn off networking configuration.
- 3. Send remote unlock request (using '#' or '*').
- Unlocking Information: Enter administrator password information (Fingerprint, password, card). Then enter the number and press '#' to confirm.
- Unlocking Information: Enter unlocking information (Fingerprint, password, card). Press 1 to delete the number, Press 2 to delete all.
4.2. Other instructions
- If unauthorized unlocking information is entered incorrectly more than 5 times within 5 minutes, the system enters an invalid input state (locked) for 90 seconds.
- Password anti-snooping function: When unlocking with a password, enter it as "XXX password XXX". Irrelevant codes can be added before and after the password, followed by '#'. The actual password must be part of the input.
- The system exits automatically after 10 seconds of inactivity.
- When voltage drops below 4.8V, an alarm sounds with each unlock. The lock can be unlocked 100 times after the alarm. Subsequent unlocks are delayed by 5 seconds. Replace the battery promptly.
- Press and hold the set key for 6 seconds to initialize the device.
4.3. Tuya Application Networking
- Download and install the "TuyaAPP" on your mobile phone.
- Open the "Tuya APP", navigate to the "registration" interface, and register an account using a mobile number or email.
- After registration, click the '+' icon (Figure 1) on the main interface, then click 'Add Device' (Figure 2). Select 'Camera / Lock' (Figure 3), find 'Wi-Fi', and click it.
- The interface will prompt to select a 2.4 GHz Wi-Fi network. Connect your mobile phone to a 2.4G Wi-Fi hotspot (or one without a password). Enter the 'Wi-Fi password' and click 'Next'.
- The lock connection network signal setting will begin. The '5' key will flash during waiting. Follow the on-screen prompts: Enter administrator information (default 123456), Press 4 for networking settings, Press 4 again, then Press 1 to start networking configuration. Wait for the process (e.g., 'Please wait... 120').
- In the 'Tuya app', click 'confirm that the keyboard light flashes'. The Wi-Fi quick connect page will appear. After finding the device, wait for completion. Click 'Finish' to connect the device successfully.
- After successful connection, tap the wake-up smart lock interface and press "9 #" for unlocking. The app control interface will prompt "click to open the door remotely?". Confirm it is safe and click "Confirm" to unlock remotely. Alternatively, click "Remote dynamic password" to generate a temporary password valid for 5 minutes.
Home Security
Project | Parameter |
---|---|
Fingerprint Sensor | Semiconductor fingerprint head |
Quiescent Current | ≤50uA |
Dynamic Current | ≤180mA |
Number Of Administrators | 10 groups |
Number Of Fingerprints | 50 groups |
Fingerprint + Password + Card Capacity | 250 groups |
Rejection Rate | ≤0.1% |
False Admission Rate | ≤0.0001% |
Induction Time | ≤0.5 seconds |
Power Supply Type | 6V |
Emergency Power Supply | Typec 5V2A |
Working Temperature | -25°C~60°C |
Working Relative Humidity | 20%~90%RH |
Keyboard | Touch the standard 12 bit keyboard |
Password Length | 8 bits |
False Password | 16 bits |
Low Voltage Alarm Voltage | 4.8±0.2V |
Adaptor Lock | 6068 |
Antilock Configuration | Mechanical anti-locking |
Lock Core Standard | Class C/Class B+ lock core |
Set Weight | 2.90 kg |