SENECA T201DCH Series Installation Manual

T201DCH100-OPEN T201DCH300-OPEN T201DCH600-OPEN

PRELIMINARY WARNINGS

The word WARNING preceded by the ⚠️ symbol indicates conditions or actions that put the user's safety at risk. The word CAUTION preceded by the ⚠️ symbol indicates conditions or actions that could damage the instrument or connected equipment.

The warranty is legally void in case of improper use or tampering with the module or devices supplied by the manufacturer, necessary for its correct operation, and if the instructions contained in this manual have not been followed.

WARNING: Before performing any operation, it is mandatory to read the entire content of this manual. The module must be used exclusively by qualified technicians in the electrical installation sector. Specific documentation is available via the QR CODE shown on page 1.

Repair of the module or replacement of damaged components must be carried out by the manufacturer. The product is sensitive to electrostatic discharge; take appropriate precautions during any operation.

Disposal of electrical and electronic waste (applicable in the European Union and other countries with separate collection). The symbol on the product or packaging indicates that the product must be delivered to an authorized collection center for recycling of electrical and electronic waste.

MODULE LAYOUT

Dimensions LxWxH: 90 x 85 x 36 mm; Weight: ≈ 145 g; Enclosure: PA6, black color

FRONT PANEL LED INDICATION

LEDSTATELED Meaning
PWR/COM GreenSolid OnThe device is powered correctly
PWR/COM GreenBlinkingCommunication via USB and RS485 port
D-OUT YellowSolid OnDigital output active

INSTALLATION RULES

Remove the locking pin to allow the instrument to open. For first-time use, the instrument will not be locked by the pin.

Position the instrument for reading using the DIN rail or locking clips. The reading direction of the instrument is indicated in the reference drawing above.

Close the instrument using the locking pin. Apply sufficient pressure for the upper semi-core to engage with the locking tabs.

CAUTION

Ensure that the direction of the current passing through the cable is as illustrated in the figure (incoming).

To increase current measurement sensitivity, pass the cable through the central hole of the instrument multiple times to create a series of turns. Current measurement sensitivity is proportional to the number of conductor passes through the hole; if the turns are not evenly distributed, a reading error may occur.

TECHNICAL SPECIFICATIONS

CERTIFICATIONS

CE, UKCA

POWER SUPPLY

  • Voltage: On Vcc and GND terminals, 11.5 – 28 Vdc
  • Consumption: Typical: 38 mA (LOAD EXCLUDED)

INSULATION

Using an insulated conductor, its sheath determines the insulation voltage. On bare conductors, an insulation of 3kV ac is guaranteed.

ENVIRONMENTAL CONDITIONS

  • Temperature: -25 ÷ +70 °C
  • Humidity: 10% ÷ 90% non-condensing.
  • Altitude: Up to 2000 m a.s.l.
  • Storage Temperature: -40 ÷ +85 °C
  • Protection Grade: IP20.

MOUNTING

35mm DIN rail IEC EN60715 or fastening with plastic clips.

CONNECTIONS

Removable 5-way screw terminals, 5 mm pitch for cables up to 2.5 mm²

COMMUNICATION PORT

Micro USB (FOR CONFIGURATION ONLY)

RS485 serial port on A+ and B- terminals; or via USB port

INPUT (through hole 36mm)

  • Measurement Type: AC/DC TRMS or DC Bipolar
  • Crest Factor: 2
  • Bandwidth: 1kHz
  • Overload: 2000 A impulsive, 3 x In continuous

RANGE

AC/DC True RMS (DIP7=OFF)DC Bipolar (DIP7=ON)
MODELDIP7DIP8A (min)B (max)C (min)D (max)
T201DCH100-OPENOFFOFF50A100A-100A+100A
T201DCH100-OPENOFFON25A50A-50A+50A
T201DCH300-OPENOFFOFF150A300A-300A+300A
T201DCH300-OPENOFFON75A150A-150A+150A
T201DCH600-OPENOFFOFF300A600A-600A+600A
T201DCH600-OPENOFFON150A300A-300A+300A

ANALOG OUTPUT on Vout and GND terminals

  • Type: 0 ÷ 10 Vdc, minimum load RLOAD =2 kΩ.
  • Protection: Reverse polarity protection and overvoltage protection
  • Resolution: 13 bit (10000 points)
  • EMI Error: < 0.5%
  • Temperature Coeff.: < 200 ppm/°C
  • Hysteresis: 0.2% of full scale
  • Response Speed: RMS: with «Fast» filter 1400 ms, with «Slow» filter 2900 ms. Bipolar: with «Fast» filter 78 ms, with «Slow» filter 650 ms.

The output type is software selectable.

DIGITAL OUTPUT

  • Type: Active, 0 - Vcc, maximum load 50 mA

The output type is software selectable.

ACCURACY

Below 2% of full scaleAbove 2% of full scale
T201DCH100-OPEN1% of full scale at 50/60Hz, 23 °C0.5% of full scale at 50/60Hz, 23 °C
T201DCH300-OPEN2% of full scale at 50/60Hz, 23 °C1% of full scale at 50/60Hz, 23 °C
T201DCH600-OPEN1% of full scale at 50/60Hz, 23 °C1% of full scale at 50/60Hz, 23 °C

OVERVOLTAGE CATEGORIES

  • Bare conductor: CAT. III 300 V
  • Insulated conductor: CAT. III 600 V

USB PORT

The module is designed to exchange data according to the defined MODBUS protocol. It features a Micro USB connector and can be configured via applications or software. USB communication has priority over RS485 communication.

The USB serial port uses the following communication parameters: 38400,8,N,1

The USB communication port behaves exactly like the RS485 bus port except for the communication parameters. During USB port use, the 485 bus will be inactive; it will automatically reactivate a few seconds after the USB port is disconnected. EASY SETUP is the software to use for configuration. For more information, consult the site indicated on the cover.

DIP-SWITCH SETTINGS

The DIP-switch positions define the module's Modbus communication parameters: Address and Baud Rate. The following table shows the Baud Rate and Address values based on the DIP-SWITCH settings:

DIP-Switch States

DIP 1-4 (ADDRESS)DIP 5-6 (BAUD RATE)DIP 7 (MEASUREMENT TYPE)DIP 8 (SCALE)
#19600AC/DC true RMSFull Scale
#219200DC BipolarHalf Scale
#338400
#...57600
#14
#15

KEY: ON, OFF

DIP-switch settings must be made with the module unpowered to avoid damage.

The instrument is supplied pre-configured for a range of 100A (DCH100), 300A (DCH300), and 600A (DCH600), with an 800 ms filter enabled and TRMS mode selected.

Note: When DIP Switches 1 to 8 are OFF, communication settings are taken from programming (EEPROM).

ELECTRICAL CONNECTIONS

ANALOG OUTPUT

Connections: Vcc, GND, 4 A+, 3 B-, 2 DO, 1 Vout

Diagram Description: Shows connections for Vcc, GND, A+, B-, DO, and Vout terminals.

DIGITAL OUTPUT

Connections: Vcc, GND, 4 A+, 3 B-, 2 DO, 1 Vout

Diagram Description: Shows connections for Vcc, GND, A+, B-, DO, and Vout terminals, with a LOAD indicator.

RS485 SERIAL PORT

Connections: Vcc, GND, 4 A+, 3 B-, 2 DO, 1 Vout

Diagram Description: Shows connections for Vcc, GND, A+, B-, DO, and Vout terminals, with a representation of signal transmission.

ANALOG OUTPUT BEHAVIOR

AC/DC TRUE RMS

MODELDIP7DIP8A (min)B (max)
T201DCH100-OPENOFFOFF50A100A
T201DCH100-OPENOFFON25A50A
T201DCH300-OPENOFFOFF150A300A
T201DCH300-OPENOFFON75A150A
T201DCH600-OPENOFFOFF300A600A
T201DCH600-OPENOFFON150A300A

Graph Description: Shows Output Voltage (V) versus Input Current (A) for AC/DC True RMS. The graph illustrates a linear relationship between input current and output voltage, with different ranges defined by DIP switch settings.

DC BIPOLAR

MODELDIP7DIP8C (min)D (max)
T201DCH100-OPENONOFF-100A+100A
T201DCH100-OPENONON-50A+50A
T201DCH300-OPENONOFF-300A+300A
T201DCH300-OPENONON-150A+150A
T201DCH600-OPENONOFF-600A+600A
T201DCH600-OPENONON-300A+300A

Graph Description: Shows Output Voltage (V) versus Input Current (A) for DC Bipolar. The graph illustrates a linear relationship between input current and output voltage, with different ranges defined by DIP switch settings, covering both positive and negative current values.

mi00615-3-it Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)

Related Documents

Preview SENECA T201DCH Series Installation Manual
Installation manual for SENECA T201DCH series current measurement modules (T201DCH100-OPEN, T201DCH300-OPEN, T201DCH600-OPEN). Provides technical specifications, wiring diagrams, and setup instructions for industrial applications.
Preview Manual de Instalación SENECA T201DCH Series
Manual de instalación para los transductores de corriente SENECA T201DCH100-OPEN, T201DCH300-OPEN y T201DCH600-OPEN. Incluye advertencias de seguridad, especificaciones técnicas, guías de instalación y configuración de comunicaciones MODBUS/RS485.
Preview SENECA T201DCH-MU Series User Manual: AC/DC Current Transducers
Comprehensive user manual for SENECA T201DCH-MU series AC/DC True RMS and DC Bipolar Current Transducers. Details device features, configuration via dip switches or Easy Setup software, Modbus RTU protocol, register tables, and testing procedures for industrial automation.
Preview SENECA T201DCH Series AC/DC Current Transducer Installation Manual
Installation manual for SENECA T201DCH50-M, T201DCH100-M, and T201DCH300-M AC/DC True RMS or DC Bipolar Current Transducers with RS485 Port and Modbus RTU Protocol. Includes module layout, technical specifications, electrical connections, and configuration details.
Preview SENECA T201DCH Series AC/DC True RMS Current Transducer Installation Manual
Installation manual for SENECA T201DCH50-MU, T201DCH100-MU, and T201DCH300-MU AC/DC True RMS and Bipolar DC current transducers. Features ModBus RTU communication and analog/digital output. Includes technical specifications, warnings, and setup instructions.
Preview SENECA T201DCH Series AC/DC True RMS Current Transducer Installation Manual
Installation manual for SENECA T201DCH50-MU, T201DCH100-MU, and T201DCH300-MU AC/DC True RMS current transducers with Modbus RTU and analog/digital output. Includes technical specifications, configuration, and safety information.
Preview SENECA T201DCH100-LP/T201DCH300-LP TRMS Current Transducer Technical Specifications and Mounting Guide
Detailed technical specifications, operating conditions, and mounting instructions for SENECA T201DCH100-LP and T201DCH300-LP contact-less TRMS current transducers. Learn about measurement principles, precision, power supply, and installation.
Preview T201DCH600-MU Installation Manual
Installation manual for the SENECA T201DCH600-MU current measurement module, detailing safety warnings, module layout, technical specifications, and electrical connections.