CleanMaxx Dust Mite Vacuum Cleaner
Model Numbers: 02243 (lime-green), 07856 (blue)
Intended Use
This device is designed to kill bacteria, remove dust, germs, and dust mites from domestic environments. It is suitable for use on mattresses, bed sheets, bed covers, upholstered furniture, and similar items.
Do not use to vacuum:
- Liquids or wet substances (e.g., wet carpet shampoo)
- Glowing ash, cigarette butts, matches, etc.
- Flammable or explosive substances
- Very fine dust (e.g., concrete dust), ash, or toner
- Sharp, hard objects (e.g., large pieces of broken glass)
The device is for personal use only and not for commercial applications. Use only as described in these instructions; any other use is considered improper.
Defects caused by improper handling, damage, or attempted repairs are excluded from the warranty. Normal wear and tear is also excluded.
Safety Instructions
WARNING: Always follow all safety notices, instructions, illustrations, and technical data provided with the device. Failure to do so may result in electric shock, fire, and/or injuries.
- This device must not be used by children. Keep the device and its power cord away from children.
- People with reduced physical, sensory, or mental abilities, or lack of experience/knowledge, may use the device if supervised or instructed on safe use and the resulting dangers are understood. Children must not play with the device.
- Always disconnect the device from the power supply when unattended and before assembling, disassembling, or cleaning.
- Never immerse the device or its power cord in water or other liquids. Ensure they cannot fall into water or get wet.
- Before each use, inspect the device for damage. Only use if there are no visible signs of damage. If damaged, it must be replaced by the manufacturer, customer service, or a similarly qualified person to avoid hazards.
DANGER – Electric Shock Hazard!
- Use and store only in closed rooms.
- Do not use in rooms with high humidity.
- If the device falls into water, immediately switch off the power supply. Do not attempt to pull it out while connected to the mains.
- Never touch the device or connection with wet hands when connected to power.
- Never suck up liquids. Do not pour liquids into the dust container. Keep the motor unit away from moisture.
WARNING – Injury Hazard!
- Eye and Skin Damage: Germicidal UV-C rays are harmful. Do not expose yourself, others, or animals to direct or reflected rays. Consult a doctor if contact occurs. Ensure UV-C lamp safety switches are not blocked.
- Suffocation Hazard: Keep children and animals away from packaging material.
- Strangulation Hazard: Keep the power cord out of reach of children and animals.
- Stuck Hazard: Keep animals, hair, jewelry, loose clothing, fingers, and body parts away from the suction opening. If the device gets stuck, switch it off immediately. Do not touch the vibration head during operation.
- Tripping Hazard: Ensure the power cord does not present a tripping hazard.
WARNING – Fire Hazard!
- Do not use in rooms with flammable substances or toxic/explosive fumes.
- Do not cover the device during operation. Do not insert objects into openings, and ensure ventilation slots are not blocked.
NOTICE – Risk of Material and Property Damage
- Connect only to a properly installed and grounded socket matching the device's technical data. The socket must remain accessible for quick isolation.
- Ensure the power cord is not pinched, kinked, laid over sharp edges, or in contact with hot surfaces. Do not wrap the cord around the device.
- Switch off and unplug the device: during thunderstorms, if damaged/faulty (unusual noises, odor, smoke), if liquids were sucked up, or if dropped.
- Have the device checked by an expert before reuse.
- Ensure the device is switched off before plugging in or unplugging.
- Never pull or carry the device by the power cord. Always pull the plug.
- Protect from heat, open flames, sub-zero temperatures, persistent moisture, wetness, and impacts.
- Do not lubricate rollers with oil or lubricant, as this attracts more dust and dirt.
- Use only original manufacturer accessories to ensure proper function and prevent damage.
- Do not place heavy objects on the device or cord.
Items Supplied
- Motor unit
- Dust container
- Dust filter
- HEPA filter
- UV-C lamp
- Operating instructions
Check items for completeness and transport damage. If damaged, do not use and contact customer service.
Device Overview
Main Unit:
- 1: On/Off switch
- 2: Ventilation slot
- 3: Motor unit
- 4: Viewing window
- 5: Dust container with filter system
- 6: Handle
Attachments:
- 7: Rollers
- 8: Left safety switch
- 9: Vibration head
- 10: UV-C lamp (under cover)
- 11: UV-C lamp cover
- 12: Right safety switch
- 13: Suction opening
- 14: Vibration button (under handle)
- 15: Dust filter
- 16: HEPA filter
Safety Devices
The device has two safety switches (8, 12). The UV-C lamp (10) only switches on when both safety switches are pressed into the motor unit (3). This automatic switch-off function is deactivated. This occurs automatically when the device is placed on a flat surface. If the safety switches lose contact with the surface, the automatic switch-off function is activated, and the UV-C lamp stops emitting light.
Tips and Notes
- Always clean mattresses on both sides.
- For new mattresses, cleaning once a month is recommended. For older mattresses, clean daily for one week, then once a month.
- Filters should be replaced every 12-18 months; the UV-C lamp (10) every 12-24 months. For spare parts, contact customer service via www.dspro.de/kundenservice.
Use
CAUTION!
- Only use the device if it is fully and correctly assembled. The dust container and filters must be inserted and undamaged. Dirt entering the motor unit can damage the motor.
- Ensure UV-C lamp safety switches are not blocked.
- Always test the device on a small, inconspicuous spot first.
- Plug the power cord into an accessible, properly installed socket.
- Place the device flat on the surface to be cleaned.
- Press the On/Off switch (1) to turn on the device. Suction and the UV-C lamp (10) will activate.
- Use the viewing window (4) to check if the UV-C lamp is on.
- Press the vibration button (14) to activate the vibration head (9). Vibration agitates the surface, and dust is sucked into the suction opening (13).
- Move the device over the surface to be cleaned.
- After vacuuming, press the On/Off switch to turn off the device.
- Unplug the power cord.
Cleaning and Storage
CAUTION!
- Empty the dust container after each use. Clean filters regularly to prevent motor overload.
- Do not use sharp or abrasive cleaning agents or pads, as they can damage surfaces.
- Ensure the power cord is unplugged and the device is disconnected from the power supply.
- Wipe the motor unit with a slightly damp, soft cloth if necessary. Dry with a soft cloth.
- Wipe the dust container recess (5) with a dry cloth.
- Store the device in a dry, cool place inaccessible to children and animals.
Emptying the Dust Container
- Grasp the dust container (5) in its recess and pull it upwards out of the motor unit (3).
- Reach into the opening and pull the filters out of the dust container.
- Empty the dust container.
- Wipe the dust container with a dry cloth if necessary.
Cleaning the Dust and HEPA Filters
- Unscrew the dust filter (15) counter-clockwise until the arrow points to the open padlock symbol.
- Remove the dust filter from the HEPA filter (16).
- Tap out both filters and clean with a soft brush if needed. For thorough cleaning, filters can be rinsed under cold running water. NOTICE: Allow filters to dry completely before reassembly.
- Place the dust filter onto the HEPA filter.
- Screw the dust filter clockwise until the arrow points to the closed padlock symbol.
- Insert the filters into the dust container (5).
- Insert the dust container with filters into the motor unit (3).
Cleaning the UV-C Lamp
CAUTION!
- The UV-C lamp becomes hot during use. Allow it to cool sufficiently after use.
- Loosen the two screws on the UV-C lamp cover (11) and remove the cover.
- Wipe the UV-C lamp with a dry cloth. NOTICE: Avoid touching the UV-C lamp with your fingers.
- Replace the cover and secure it with the two screws.
Troubleshooting
If the device is not functioning correctly, first check if the problem can be resolved. If not, contact customer service.
Do not attempt to repair electrical devices yourself!
Problem | Possible Cause / Solution / Tips |
---|---|
Device does not suck. |
|
Low suction power. |
|
UV-C lamp (10) does not light up. |
|
Vibration head (9) does not vibrate. |
|
An unpleasant odor is detected during vacuuming. |
|
Technical Data
- Model Number: SC04
- Article Numbers: 02243 (white-lime-green); 07856 (white-blue)
- Voltage Supply: 220-240 V ~ 50/60 Hz
- Power: 300 W
- Protection Class: II
- Instruction Manual ID: Z 02243_07856 M DS V4 0520 uh
CE Marking
Disposal
CAUTION!
- The UV-C lamp must be removed and disposed of separately before disposing of the device. Refer to the "Cleaning and Storage" chapter for removal instructions.
- Dispose of packaging material in an environmentally friendly manner at a collection point.
- This device is subject to the European Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE). Do not dispose of as household waste; dispose of it environmentally through an officially approved waste disposal company.
Contact Information
Kundenservice / Importeur | Customer Service / Importer
DS Produkte GmbH
Am Heisterbusch 1
19258 Gallin
Deutschland
Tel.: +49 38851 314650*