Instruction Manual for Rotronic models including: CP11, CP11 Humidity and Temperature Meter, CP11, Humidity and Temperature Meter, Temperature Meter, Meter
SHORT INSTRUCTION MANUAL General description The CP11 is an accurate hand-held datalogger that displays & records relative humid-ity, temperature, CO2 and calculated parameters such as dew point and wet bulb. These short instructions are limited to a description of the main functions and installa
Medidor CO2 Rotronic CP-11 | PoolComet
File Info : application/pdf, 1 Pages, 283.42KB
DocumentDocumentSHORT INSTRUCTION MANUAL Congratulations on your purchase of the new portable humidity, temperature and CO2 instrument. Please read these short instruction carefully before installing the device. General description The CP11 is an accurate hand-held datalogger that displays & records relative humidity, temperature, CO2 and calculated parameters such as dew point and wet bulb. These short instructions are limited to a description of the main functions and installation of the device. The detailed instruction manual can be found on the internet at www.rotronic-humidity.com Programming Most of the settings, such as memory clear, CO2 alarm, units( C/ F), sampling rate, pressure compensation and real time clock can be changed using the function keys. Integrated probe Built-in CO2 sensor w/ calibration cap 5VDC adaptor port PC connect port Tripod hole Battery compartment Power Supply The CP11 uses 4pcs AA alkaline batteries or 5VDC adaptor (optional accessory). To insert (replace)the batteries, use the screw driver enclosed to loose 2 screws and put in the batteries in correct polarity with good contact. Connection to PC or Laptop Connect the CP11 via mini USB cable to a PC or Laptop. Recorded data download can be easily downloaded with the software enclosed. Functions Key ON/OFF/SETUP -Press to turn on or turn off the instrument -In normal mode, press longer to enter setup mode. -Press with HOLD key to disable sleep mode HOLD/UP -Freezes the current readings -Cancels data hold function -Selects unit or increases value in setup START/ESC -Start automatic logging mode -Exits setup/recall/logging MODE/RECALL -Press to switch displayed parameter -Press longer to enter memory recall MEM/DOWN MIN/MAX/AVG/ENTER -Press to manually record the reading -Activates MIN,MAX,AVG function -Selects unit or decreases value in setup -Saves and finishes settings Display CO2 TEMPDPWBT UpperLCD Humidity/TEMP/CO2....reading LowerLCD Real time clock display HOLDMAXMINAVGCAL CO2 HOLD Carbon dioxide reading Readings are hold unchanged CO MIN/MAX Minimum/Maximum readings FO AVG Average reading Low battery indicator %rh DP Dew point temperature TEMP Temperature WBT Wet bulb temperature AM REC %rh oC/oF Unit of relative humidity Celsius/Fahrenheit of temperature PM Re call CAL In calibration status REC In manual/automatic logging status RECALL In manual records recall mode Operation POWER ON/OFF Press ON/OFF SET to turn the meter on. At power up, it emits a short beep and per-forms 28 sec. countdown (Fig.1) for meter warm up, then enters normal mode with real time clock displayed (Fig.2). Date and time are displayed in turns. To power off, press ON/OFF SET again to turn off the meter. Fig.1 CO2 AM Fig.2 DATE/TIME SETUP ON/OFF When meter is powered on , hold down SET for more than 2 seconds until entering meter setup mode. Press HOLD or MEM key to select the program P80 (rtc) and press MIN MAX/AVG key to enter. First, choose the time format as 12hour or 24hour by pressing HOLD or MEM and then press MIN MAX/AVG to confirm. Second, choose the date format as Month-Day-Year or Day- Month-Year by pressing HOLD or MEM and then, press MIN MAX/AVG key to confirm. Now, start to input the real time clock value from year, month, day, hour, minute to second. Press HOLD or MEM to select and then press MIN MAX/AVG to confirm. Press START to return to normal. ESC UNIT SETUP ON/OFF When meter is powered on , hold down SET for more than 2 seconds until entering meter setup mode. Press HOLD or MEM key to select the program P50 (unit) and press MIN MAX/AVG key to enter. Press HOLD or MEM to select oC or oF and then press MIN MAX/AVG to confirm. Press START ESC to return to normal. TAKING MEASUREMENT The meter starts measurement when power on and update readings every second. In the condition of operating environment change, it takes 30 seconds to respond for CO2 sensor. NOTE: Do not hold the meter close to faces in case exhalation affects CO2 Humidity Press MODE RECALL to switch to humidity display.(Fig.3).The lower display shows the real time clock. TEMP,DP,WBT Press MODE RECALL to switch to temperatures display(Fig.4,5,6). The lower display shows the real time clock. %rh Fig.3 CO2 (Carbon Dioxide) Press MODE RECALL to switch the mode to CO2.User can get the CO2 reading in ppm unit on main display.(Fig.7). The lower display shows the real time clock. DATA HOLD AM In normal display mode, press HOLD to freeze the readings, "HOLD" icon is flashed on the left top of LCD (Fig.8). All current readings are kept unchanged. Press HOLD again to cancel the hold function. NOTE: The hold function is disabled in Min/Max/Avg mode. AM BACKLIGHT The backlight will be activated for 10 seconds by pressing any key. MIN,MAX,AVG,CURRENT REVIEW This meter allows you to check the minimun, maximum, average, current value from the moment you press the AM MIN MAX/AVG key. Under normal mode, each press of MIN MAX/AVG displays MIN, MAX, AVG and current value in sequence. CO2 (Fig.9~11). To return to normal mode, press START to ESC escape(Fig.12) In this max/min/avg/current modes, it shows the corresponding readings on main display and the accumulated time of how long you are in this mode. The maximum time interval for this function is 18 hours. AM TEMP CO Fig.4 DP CO Fig.5 WBT CO Fig.6 Fig.7 Press MODE RECALL can switch the displayed parameters. (Fig.13) HOLD Distinguishing the normal display and current review by checking the time display format. In normal display, date & time are displayed in turns. In current review, the lower display is the accumulated time of how long you are in max/min/avg mode. %rh Fig.8 NOTE: "HOLD" & "MANUALLY RECORD" & "RECALL" functions are disabled in Min/ Max/Avg mode. CO2 CO2 CO2 CO2 MAX AVG MAX Fig.9 Fig.10 Fig.11 AM Fig.12 %rh Fig.13 ALARM The meter features audible alarm to give warnings when CO2 concentration exceeds the limit. (See "Meter Setup" section for setting alarm threshold). It emits beeps (Abt. 80dB) when CO2 level goes over the set value and stops only when the readings fall below the set value. It beeps again when value goes over the limit. AUTO POWER OFF The meter turns off automatically after 20 minutes of inactivity. To override the function, first, the meter is in power off status. Hold down ON/OFF SET and HOLD for 2 seconds to turn on the meter until "n" appears.(Fig.14) NOTE: Auto sleep function will be disabled during calibration & auto recording mode. Auto sleep function WILL NOT be disabled automatically via using adaptor. Fig.14 MANUALLY RECORDING MEM The meter features a 99 point memory. In the normal or hold mode, press key to start recording, the REC icon and the main display will be flashed 3 times. The memory sequential number will show on the main display with 99 points in maximum. The data in the memory contains all parameters information and not only the displayed parameter. When all 99 points memory are occupied, a "FULL" message will be displayed on the screen. If you think the reading is changing too fast, you can press HOLD key to freeze current reading first then manually record the data. This recording function will be disabled in the Min/Max mode. 99 MEMORIES RECALL In normal or hold mode, press MODE RECALL key for more than 2 seconds until the Re ca ll icon flashes. Press HOLD or MEM to scroll the memories. The memory sequential number displays on main LCD first and reading comes after. (Fig16&17). Press MODE RECALL key to switch the display parameter.(Fig.18).The time displayed in memory recall mode is the recording time of this memory. CO2 %rh AM REC Fig.15 DATA LOGGING Rec al l Fig.16 Rec al l Fig.17 Rec al l Fig.18 The meter can automatically record Humidity/TEMP./CO2 for long term environment monitor. The memory capacity is 6000 points for each parameter. Users can set up sampling rate from 1 second to 4hours 59 minutes and 59 seconds. The factory preset rate is 30 second. To setup the sampling rate, when meter is powered on , hold down ON/OFF SET for more than 2 seconds until entering meter setup mode. PressHOLD orMEM key to select the program P60 (rAtE) and press MIN MAX/AVG key to enter. Press HOLD or MEM to select the sample rate from hour, minute to second and then press MIN MAX/AVG to confirm. Press START to return to normal. ESC After sampling rate is selected, press START ESC for 2 seconds under normal mode to start logging. The REC icon flashes to indicate the logging status and LCD main display shows the real time value. Lower displays are real time clock.(Fig.19) Repeat above to start another run of logging. While the logging CO2 space is full, it shows "FULL". To terminate data logging, press START ESC for 2 seconds, REC icon stops flashing. Press MODE RECALL key to switch to the mode you want to see. Except the mode switching function, auto power off, min/max, manual record, hold and recall functions are all disabled during logging. AM REC Meter Setup Fig.19 ON/OFF When meter is powered on , hold down SET for more than 2 seconds until entering meter setup mode. To exit setup, press START to return to normal mode. ESC Press HOLD or MEM key to select the program and press MIN MAX/AVG key to select. The programmable setting flashes on display, press HOLD or MEM key to select and press MIN MAX/AVG key to confirm. To leave without saving, press START key to return. ESC P10, 99 points MEMORY clear P11, choose yes or no Note: " "is displayed while memory is cleared. P20, auto LOG data clear P21, choose yes or no P30, CO2 ALARM setup P31, choose from 100 to 9900 P40, CO2 ABC setup P41, Choose on or off P50, Temp. UNIT setup P51, choose oC or oF oC P60, logging sampling RATE P61, choose from 04:59:59 to 00:00:01 P70, PRESSURE compensation P71, choose from 700 to 1990hpa P80, REAL TIME CLOCK setup P81, choose 12 or 24 hour format choose DATE format Input Year/ Month/ Day Input Hour/ Min./Sec. year month date Hour Minute Second oF or Note: " "is displayed while memory is cleared. Note: -Factory preset 1400ppm. -Adjustable scale is every 100ppm Note: -Factory preset ABC function as ON Note: -Factory preset oC Note: -Factory preset at 30 sec. -The format is hour:minute:second Note: -Factory preset at 1013hpa -The adjustable scale is every 1hpa. Note: -Factory preset at 12H & dd-mm-year format. Battery low indicator A battery low icon " " appears when the supplied power is too low to maintain a normal operation. Please replace the batteries for accurate measuring. Suggest to use adaptor (optional part: AC1214) for long term measuring & datalogging. Humidity Calibration This meter can be calibrated either via 35% & 80% salt bottle or humidity generator. The ambient condition is recommended as stable 25oC. While the meter is powered off, plug the sensor probe into 35% salt. Press ON/OFF SET , START ESC , MEM simultaneously for 3 seconds to turn on the meter and enter calibration mode. Press HOLD or MEM to select 35.0% calibration and press MIN MAX/AVG to start. "CAL" and calibrating value are blinking on the LCD. CAUTION: Do not calibrate the humidity without the default calibration salt. Otherwise, it will cause permanent damage. Contact ROTRONIC for calibration salt or services. Single point calibration will cause error code E11 or non accurate reading. Always do dual point calibration to complete a process. Suggest to calibrate low humidity first. CO2 Calibration The sensor has an automatic calibration function to secure long-term accuracy. If a calibration is desired, press ON/OFF SET START ESC MEM simultaneously for 3 seconds to turn on the meter and enter calibration mode. Press HOLD or MEM key to select 400 ppm CO2 calibration (Outside Air calibration). Press MIN MAX/AVG to start and see"CAL" and CO2 value blinking on LCD. Wait about 10 minutes until the blinking stops and the calibration is completed and back to normal mode. While choose 0 ppm CO2 calibration, remove the cap from meter rear side and plug the CO2 CALIBRATOR pipe into the sensor hole beneath. Wait about 10 min until the blinking stops and the calibration is completed and back to normal mode. CAUTION: Do not calibrate the meter in the air with unknown CO2 concentration. Otherwise, it will be calibrated as 0 or 400ppm by default and leads to inaccurate measurements. Ensure the batteries are with full voltage during the calibration to prevent from interruption or failed calibration. When the accuracy becomes a concern after a long time usage, return to dealers for standard calibration. Trouble Shooting Error E01 E33 E02 E03 E04 E11 E31 E32 E33 Messages CO2 sensor is out of order CO2 sensor is out of order measured value is under range measured value is over range Original data error results in this error (DP, WB) RH calibration error Temp. sensor or AD damaged Memory IC damaged RH sensor or circuit damaged Solution Turn off meter and re-start again Retry CO2 calibration Put meter in normal condition Put meter in normal condition Solve the original data error Retry humidity calibration Return for repair Return for repair Return for repair Technical Data Humidity/accuracy: Temperature/accuracy: 0.1% to 99.9%/ ±3.0%(10~95%@25 °C), ±5% (other) -20...60oC/+0.3oC@5~40oC CO2 /accuracy: 0...9999ppm/+(30ppm+5% of reading)@0~5000ppm Storage and transit: -20...60oC/10...90%rh, non condensing. Operating limit at electronics:0...50oC for CO2, -20...60oC for rest/ non condensing. Memory: 99 records manually, 18000 records auto logging. Dimensions: 234(L)x77(W)x42(H),mm Weight: 200gr. Battery type: 4pcs AA alkaline DC power type: 5VDC, 250mA. Optional available. PC connection: mini USB port Optional Accessory 5VDC universal adaptor: CO2 calibrator: Part Number AC1214 CO2 CALIBRATOR ROTRONIC AG, CH-8303 Bassersdorf Tel. +41 44 838 11 44, www.rotronic.com ROTRONIC Messgeräte GmbH, D-76275 Ettlingen Tel. +49 7243 383 250, www.rotronic.de ROTRONIC SARL, 56, F - 77183 Croissy Beaubourg Tél. +33 1 60 95 07 10, www.rotronic.fr ROTRONIC Italia srl, I- 20157 Milano Tel. +39 2 39 00 71 90, www.rotronic.it ROTRONIC Instruments (UK) Ltd, West Sussex RH10 9EE Phone +44 1293 571000, www.rotronic.co.uk ROTRONIC Instrument Corp, NY 11788, USA Phone +1 631 427-3898, www.rotronic-usa.com ROTRONIC Instruments Pte Ltd, Singapore 159836 Phone +65 6376 2107, www.rotronic.com.sg ROTRONIC Shanghai Rep. Offi ce, Shanghai 200233, China Phone +86 40 08162018, www.rotronic.cnGPL Ghostscript 9.55.0