Instruction Manual for HYTRONIK models including: HIR27, Flush Mount PIR Motion Sensor, HIR27 Flush Mount PIR Motion Sensor, Mount PIR Motion Sensor, PIR Motion Sensor, Motion Sensor, Sensor
HIR27 Flush Mount Sensor Hytronik
File Info : application/pdf, 6 Pages, 1.36MB
DocumentDocumentInstallation and Instruction Manual FLUSH MOUNT PIR MOTION SENSOR One DALI Channel Output HIR27 HIR27/R HIR27/H HIR27/RH 1. Technical Specifications Mains voltage Stand-by power Switched power Warming-up Sensor principle Detection range (Max.)* HIR27 Detection range (Max.)* HIR27/R Detection range (Max.)* HIR27/H Detection range (Max.)* HIR27/RH Detection angle Operation temperature IP rating EMC standard (EMC) Safety standard (LVD) Certification 220~240VAC 50/60Hz <0.5W Max. 40pcs devices, 80mA Appr. 20s PIR detection Installation Height : 6m Detection Range (Ø) :9m Installation Height : 6m Detection Range(Ø) :10m Installation height15m (forklift) 12m (person) Detection range (Ø)24m Installation height20m (forklift) 12m (person) Detection range (Ø)40m 360° Ta: -20°C ~ +50°C IP20 EN55015, EN61000, EN61547 EN60669-1, EN60669-2-1, AS/NES60669-1/-2-1 CB, CE , EMC, LVD, RCM, ROHS compliance 2. Installation 65mm 1 3 2 62 70.5 75.2 4 5 A B * Install blind as required 78 3. Functions 3.1 Daylight Harvest (Daylight Regulating) Daylight sensor measures the available surrounding natural light, calculates how much electrical light is needed to reach the total lux expected. The demand is given to the LED driver by DALI signal, so as to deliver the needed amount of electric light. Light level Hold time Normal Electric Light Energy Saving Zone Stand-by time Daylight controlled light Natural light 0 24 Time (hrs) 3.2 Manual Override With the help of push-switch, this sensor can be over-ridden by the end-user to manually switch on/off the light, which makes the product more user-friendly and offers more options to fit some extra-ordinary demands: * Short Push (<1s): on/off function; On ¹ Off: the light turns off immediately and cannot be triggered ON by motion until the expiration of pre-set hold-time. After this period, the sensor goes back to normal sensor mode. Off ¹ On: the light turns on and goes to sensor mode, no matter if ambient Lux level exceeds the daylight threshold or not. * Long Push (>1s): adjust the target lux level by turning the light up or down. Both the adjustment on remote control and push switch can overwrite each other. The last adjustment remains in memory. Note: if end-user do not want this manual override function, just leave the "push" terminal unconnected to any wire. 3.3 Semi-auto Mode (Absence Detection) Selecting this mode will activate the following logic: Manual on - The lights will not switch on until they have manually been switched on at the wall switch. The occupancy sensor is inactive whilst the lights are off. Auto off - When the lights are on, the sensor becomes active and monitors the space for activity. Once the area is vacated (absence setection), the sensor will automatically switch off the lights if the last person out forgets to switch off the light manually. Note: The wall switch can be assigned to function 3.2 or 3.3 , but not both. The default function is manual override. 3.4 Synchronisation Function By connecting the "SYNC" terminals in parallel (see wiring diagram), no matter which sensor detects motion, all HIR27 in the group will turn on the lights when surrounding natural light is below the daylight threshold. The detection area could be widely enlarged in this way. Wire Preparation 1 2 3 * Install lens as required 6 7 1 2 1. Ceiling (drill hole 65mm) 2. Carefully prise off the cable clamps. 3. Make connections to the pluggable terminal blocks. 4. Insert plug connectors and secure using the provided cable clamps, then clip terminal covers to the base. 5. Fit detection blind (if required) and desired lens. 6. Clip fascia to body. 7. Bend back springs and insert into ceiling. 0.75 - 2.5mm 8mm (min 6mm, max 11mm) Pluggable screw terminal. It is recommended to make connections to the terminal before fitting to the sensor. HIR27-20210813-A0 4. Wiring Diagram LED Driver LED Driver LED Driver LED Driver 5. Description of the Button Functions (remote control HRC-11) 1 3 7 9 & A 4h h 4h HRC-11 Permanent ON/OFF [button 1 ] Press button 1 , to select permanent ON or permanent OFF mode. * Press button 2 / 4 to to quit this mode. The mode will change to AUTO Mode after power failure. RESET[ button 2 ] Press button 2 , all settings go back to default values as below: Hold-time 5min, Daylight sensor 100Lux, Stand-by time: 10min, Stand-by dimming level: 20% Detection range [ zone 8 ] These two buttons are disabled. Daylight threshold [ zone 9 ] Press buttons in zone 9 to set daylight sensor at 2Lux/ 10Lux / 50Lux / 100Lux / 300Lux / 500Lux / Disable. Note: To set daylight sensor at 100Lux / 300Lux / 500Lux, press 3 Shift button first. 4 Shift [ button 3 ] 2 Press button 3 , the LED on the top left corner is on to indicate mode 5 selection. All values / settings in RED are in valid for 20 seconds. Auto Mode [ button 4 ] 6 Press button 4 to initiate automatic mode. The sensor starts working and all settings remain as before the light is switched ON/OFF. Semi-auto Mode [ button 3 & 4 ] 8 1. Press button 3 Shift (the red LED is on for indication). 2. Press button 4 to initiate semi-auto mode. The fixture is manually on by push-switch and automatically off in semi-auto mode. 10 Power output [ button 5 ] (Daylight harvest without occupancy) 1. Press button 3 , the red LED is on for indication. 11 2. Press button "Twilight", the function of movement detection is disabled. Note: the function of "Sensor off" is disabled. 12 Brightness +/- [ button 6 ] 13 Press button 6 to adjust the light brightness between 10%~100%. Scene prog. [ zone 7 ] (One-key-commissioning) 14 1. Press button "Start" to program. 2. Select the buttons in 8 "Detection range", 9 / 10 "Daylight threshold", 11 "Hold time", 12 "Stand-by time", 13 "Stand-by dimming level" to set all parameters. 3. Press button 7 "Memory" to save all the settings programmed in the remote control. 4. Press button 7 "Apply" to set the settings to each sensor unit(s). For example, to set detection range 100%, daylight threshold Disable, hold time 5min, stand-by time +, stand-by dimming level 30%, steps should be: Press button 7 Start, button 8 100%, 10 Disable, 3 Shift, 11 5min, 3 Shift, 12 + , 13 30%, 7 Memory. By pointing to the sensor unit(s) and pressing 7 Apply, all settings are passed on the sensor(s). Ambient daylight threshold [ button 10 ] 1. Press button 3 Shift, the red LED starts to flash. 2. Press button 10, the ambient lux level is sampled and set as the new daylight threshold / target Lux level. Hold time [ zone 11 ] Press buttons in zone 11 to set the hold time at 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min. Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button 3 Shift at first. 2. 2s is for test purpose only, stand-by period and daylight sensor settings are disabled in this mode. *To exit from Test mode, press button 2 or any button in zone 11 . Stand-by time [ zone 12 ] Press buttons in zone 12 to set the stand-by period at 0s / 10s / 1min / 5min / 10min / 30min / 1h / +. Note: "0s" means on/off control; "+" means bi-level control, 100% on when motion detected, and remains at the stand-by dimming level when no presence after hold-time. Stand-by dimming level [ zone 13 ] Press buttons in zone 13 to set the stand-by dimming level at 10% / 20% / 30% / 50%. Note: the function of 24h/12h/4h/30s are disabled. Button "Dual-tech & RF mode" is disabled. HIR27-20210813-A0 6. Detection Pattern & Optional Accessories 1. HIR27 (Low-bay) HIR27: Low-bay flat lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-6m) A: Tangential movement B: Radial movement Mount height 2.5m h = max.6m h = max.6m 3m A Tangential: max. 9m B Radial: max. 4m 4m 5m insensitive sensitive insensitive sensitive 6m Optional Accessory --- Ceiling/Surface Mount Box: HA03 Tangential (A) max 50m2 (Ø = 8m) max 64m2 (Ø = 9m) max 38m2 (Ø = 7m) max 38m2 (Ø = 7m) max 38m2 (Ø = 7m) Radial (B) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) Ø 94 4.2 75 44 66 Optional Accessory --- Blind Insert for Blocking Certain Detection Angles Valid Range Valid Range Blind Option 1 --- Aisle Detection Blind Option 2 --- 180º Detection HIR27-20210813-A0 2. HIR27/R (Reinforced Low-bay) HIR27/R: Low-bay convex lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-6m) A: Tangential movement B: Radial movement Mount height 2.5m h = max.6m h = max.6m 3m A Tangential: max. 10m B Radial: max. 5m 4m 5m insensitive sensitive insensitive sensitive 6m Optional Accessory --- Ceiling/Surface Mount Box: HA03 Tangential (A) max 79m2 (Ø = 10m) max 79m2 (Ø = 10m) max 64m2 (Ø = 9m) max 50m2 (Ø = 8m) max 50m2 (Ø = 8m) Radial (B) max 20m2 (Ø = 5m) max 20m2 (Ø = 5m) max 20m2 (Ø = 5m) max 20m2 (Ø = 5m) max 20m2 (Ø = 5m) Ø 94 4.2 75 44 66 Optional Accessory --- Blind Insert for Blocking Certain Detection Angles Valid Range Valid Range Blind Option 1 --- Aisle Detection Blind Option 2 --- 180º Detection HIR27-20210813-A0 3. HIR27/H (High-bay) HIR27/H: High-bay lens detection pattern for forklift @ Ta = 20ºC (Recommended ceiling mount installation height 10m-15m) A: Tangential movement B: Radial movement h = max.15m A Tangential: max. 24m h = max.15m B Radial: max. 16m insensitive sensitive insensitive sensitive Mount height 10m 11m 12m 13m 14m 15m Tangential (A) max 380m2 (Ø = 22m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) Radial (B) max 201m2 (Ø = 16m) max 201m2 (Ø = 16m) max 201m2 (Ø = 16m) max 177m2 (Ø = 15m) max 133m2 (Ø = 13m) max 113m2 (Ø = 12m) HIR27/H: High-bay lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-12m) A: Tangential movement B: Radial movement Mount height 2.5m h = max.12m A Tangential: max. 20m h = max.12m B Radial: max. 3m 6m 8m 10m 11m insensitive sensitive insensitive sensitive 12m Optional Accessory --- Ceiling/Surface Mount Box: HA03 Tangential (A) max 50m2 (Ø = 8m) max 104m2 (Ø = 11.5m) max 154m2 (Ø = 14m) max 227m2 (Ø = 17m) max 269m2 (Ø = 18.5m) max 314m2 (Ø = 20m) Radial (B) max 7m2 (Ø = 3m) max 7m2 (Ø = 3m) max 7m2 (Ø = 3m) max 7m2 (Ø = 3m) max 7m² (Ø = 3m) max 7m² (Ø = 3m) Ø 94 4.2 75 44 66 Optional Accessory --- Blind Insert for Blocking Certain Detection Angles Valid Range Valid Range Blind Option 1 --- Aisle Detection Blind Option 2 --- 180º Detection HIR27-20210813-A0 4. HIR27/RH (Reinforced High-bay with 3-Pyro) HIR27/RH: Reinforced high-bay lens detection pattern for forklift @ Ta = 20ºC (Recommended ceiling mount installation height 10m-15m) A: Tangential movement B: Radial movement Mount height 10m h = max.20m A Tangential: max. 40m h = max.20m B Radial: max. 15m insensitive sensitive insensitive sensitive 11m 12m 13m 14m 15m 20m Tangential (A) Radial (B) max 346m2 (Ø = 21m) max 660m2 (Ø = 29m) max 177m2 (Ø = 15m) max 177m2 (Ø = 15m) max 907m2 (Ø = 34m) max 154m2 (Ø = 14m) max 962m2 (Ø = 35m) max 154m2 (Ø = 14m) max 1075m2 (Ø = 37m) max 113m2 (Ø = 12m) max 1256m2 (Ø = 40m) max 113m2 (Ø = 12m) max 707m2 (Ø = 30m) max 113m2 (Ø = 12m) HIR27/RH: Reinforced high-bay lens detection pattern for single person @ Ta = 20OC (Recommended ceiling mount installation height 2.5m-12m) A: Tangential movement B: Radial movement Mount height 2.5m h = max.12m A Tangential: max. 30m h = max.12m B Radial: max. 4m 6m 8m 10m 11m insensitive sensitive insensitive sensitive 12m Optional Accessory --- Ceiling/Surface Mount Box: HA03 Tangential (A) max 38m2 (Ø = 7m) max 154m2 (Ø = 14m) max 314m2 (Ø = 20m) max 531m2 (Ø = 26m) max 615m2 (Ø = 28m) max 707m2 (Ø = 30m) Radial (B) max 7m2 (Ø = 3m) max 7m2 (Ø = 3m) max 7m2 (Ø = 3m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) Ø 94 4.2 75 44 66 7. Additional Information / Documents 1. Regarding precautions for PIR sensor installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->PIR Sensors - Precautions for Product Installation and Operation 2. Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy HIR27-20210813-A0