LogTag TRED30-16CP Temperature Recorder
Quick Start Guide - Version A
Website: www.logtag-recorders.com
Contents
Downloading LogTag Analyzer
To download the latest LogTag Analyzer software, open your web browser and navigate to:
https://logtag-recorders.com/en/support/ [download icon]
- Click 'Go to downloads page' to navigate to the download page.
- Click 'Download Now' to begin the download.
- Click 'Run' or 'Save File', then double-click the downloaded file to launch the LogTag Analyzer Setup Wizard.
Follow the on-screen prompts to install LogTag Analyzer.
Click 'Finish' to exit the LogTag Analyzer Setup Wizard.
Configuring your TRED30-16CP
To configure your TRED30-16CP, dock it into a LogTag interface cradle. Connect the cradle to your computer using the provided USB cable. The USB socket is located at the back of the interface cradle.
Image Description: The LogTag TRED30-16CP temperature recorder. It features a blue casing with a white display screen. The screen shows 'REC.', 'TIME 12:39', 'CURRENT 12.9°C', and temperature range indicators (-19 to -7, -25 to -20). Buttons labeled 'REVIEW MARK' and 'START CLEAR STOP' are visible. The device has a loop at the top for attachment.
- Open LogTag Analyzer.
- Click 'Configure' from the 'LogTag' menu or click the 'Wizard' icon.
- Adjust your logger configuration settings as needed. For detailed information, refer to the Product User Guide or press 'F1' for keyboard help.
- (Smart Probe: To enable smart probe logging, navigate to the 'Additional Features' tab and select 'Enable Smart Probe'.)
- Click 'Configure' to upload the settings to the logger.
- Click 'Close' to exit the configuration page.
Starting your TRED30-16CP
Ensure the sensor is connected before starting the TRED30-16CP.
Diagram Description: A detailed illustration of the TRED30-16CP display. Key elements are labeled: 'Recording State Indicators' (showing REC, PAUSED, STOPPED, READY), 'Time Indicators' (CLOCK ADJ, DURATIONTIME, TIME VALUE), 'ALERT/OK Indicator', 'Battery Low Symbol', 'Day Number', 'Reading Type' (MAXMIN, CURRENT), 'Temperature' (°C, °F), 'Alarm Threshold Markers' (e.g., -20, -21, -10), 'Day Alarm Markers' (e.g., -7, -1), and 'Temperature Unit'.
To start recording:
- Press and hold the START/CLEAR/STOP button.
- Continue holding while 'STARTING' is displayed.
- Release the button when 'READY' disappears.
The TRED30-16CP will now record temperature data.
Image Description: Two display states are shown. The first shows 'READY' with 'TIME 09:16'. The second shows 'REC.' with 'TIME 09:46' and 'CURRENT -2 1.8°C'.
During Recording
The currently stored Min/Max temperature values can be reset at any time while the unit is recording. They cannot be reset once the unit has been stopped.
Diagram Description: A circular flow diagram illustrating the display states during recording and potential Min/Max temperature resets. It shows four distinct logger screen views: one displaying 'Ur -2 1.8°C MAX' with temperature thresholds, another showing 'Ur -55.2°C MIN' with thresholds, and two intermediate states. Arrows connect these views, indicating a process of reviewing or resetting trip minimum and maximum temperature values.
To reset the values, please refer to the Product User Guide.
For more information on clearing alarms and reviewing Min/Max trip temperatures, also consult the Product User Guide.
Downloading Results
Dock your TRED30-16CP into any LogTag interface cradle and connect the cradle to your computer via the USB cable. The USB socket is on the back of the interface cradle.
Image Description: The LogTag TRED30-16CP temperature recorder. It features a blue casing with a white display screen. The screen shows 'REC.', 'TIME 12:39', 'CURRENT 12.9°C', and temperature range indicators (-19 to -7, -25 to -20). Buttons labeled 'REVIEW MARK' and 'START CLEAR STOP' are visible. The device has a loop at the top for attachment.
- Open LogTag Analyzer.
- Click 'Download' from the 'LogTag' menu or press F4. After a few seconds, the downloaded data will appear. Data can be viewed in Report, Chart, Data, Summary, or Day Summary formats by selecting the tabs at the bottom of the chart dialog.
- Data can be saved in various formats, including TXT, PDF, HTML, and CSV for import.
- Click 'Close' to exit the download page.
Accessories
Required:
The TRED30-16CP requires these items for proper functioning:
- CP110 Smart Probe (Recommended): Image Description: A diagram of the LogTag CP110 Smart Probe, consisting of a cable connected to a temperature probe, designed to attach to a LogTag logger.
- ST10 External Probe: Image Description: A diagram of the LogTag ST10 External Probe, featuring a rigid probe attached to a cable for connection to a LogTag logger.
- LTI Interface: Image Description: A diagram of the LogTag LTI Interface, a black cradle used to connect LogTag loggers to a computer via USB.
Optional:
The TRED30-16CP may require these items for proper functioning (not included):
- Buffer assembly (Not included): Image Description: A diagram of a bottle labeled 'LogTag', representing a buffer assembly, likely for calibration or maintenance.
- Wall mount (Not included): Image Description: A diagram of a wall mounting bracket designed to secure a LogTag device.