User Guide for SmartPower SYSTEMS models including: TBF15P-1120 Electronic Power Conditioner, TBF15P-1120, Electronic Power Conditioner, Power Conditioner, Conditioner

Guardian-UG

PDF E Guardian With Smart Ground D I G S E S U

1.Turn off and un-plug equipment to be protected from wall outlet. 2. Plug the equipment into the Guardian unit. 3. Plug the Guardian unit into grounded wall outlet.


File Info : application/pdf, 4 Pages, 1.40MB

PDF preview unavailable. Download the PDF instead.

Guardian-UG
UUSSEER'R'SSGGUUIIDDEE

GUARDIAN WITH SMART GROUND
ELECTRONIC POWER CONDITIONER
Thank you for purchasing this Guardian Electronic Power Conditioner. Smart Power Systems is dedicated to developing and manufacturing the highest performance power protection and filtration devices for your electronic equipment. Proper use of this device will provide the protection needed for your connected equipment.

16005550 Rev.05/22

Use this user's guide for the following products:

MODEL / PART NUMBER TBF15P-1120 TBF15P-1121TN TBF15P-1111TN

DESCRIPTION 120V/15A, two 5-15R outlets 120V/15A, two 5-15R outlets, RJ11 + RJ45 120V/15A, one pigtail 5-15R outlet, RJ11 + RJ45

CAUTION
· Use only in dry locations indoors. · Avoid dropping the unit. · Only plug the Guardian into a three pronged grounded outlet. This unit is not to be used with any
type of ground "lift" or pin eliminator. · Do not open the Guardian unit, there are no serviceable parts inside. Opening the unit will void
your warranty.
CAUTION
This device features an internal protection that will disconnect the surge protective component at the end of its useful life but will maintain power to the load now unprotected. If this situation is undesirable for the application, follow the manufacturer's instructions for replacing the device.
CAUTION
Do not install this device if there is not at least 10 meters (30 feet) or more of wire between the electrical outlet and the electrical service panel.
CAUTION
Risk of Electric Shock. Do not plug into another relocatable power tap.
ATTENTION
·· Utiliser uniquement dans des endroits secs à l'intérieur. · Évitez de faire tomber l'appareil. · Brancher le Guardian en trois volets prise de terre. Cette unité ne doit pas être utilisé avec
tout type de terrain "ascenseur" ou broches éliminateur. · Ne pas ouvrir l'unité Guardian, il n'y a pas de pièces réparables. Ouverture de l'unité
annulera votre garantie.
ATTENTION
Cet appareil dispose d'une protection interne qui va déconnecter le composant de protection contre les surtensions à la fin de sa vie utile mais se maintenir au pouvoir à la charge maintenant sans protection. Si cette situation est souhaitable pour l'application, suivez les instructions du fabricant pour le remplacement de l'appareil.
ATTENTION
Ne pas installer cet appareil si il n'y a pas au moins 10 mètres (30 pieds) ou plus de fil entre la prise électrique et le panneau de service électrique.
ATTENTION
Risque de choc électrique. Ne branchez pas dans une autre puissance robinet délocalisables.

FEATURES
Modem & Data Protection (model dependent) Protection is extended to your phone and network lines with the addition of RJ11 and RJ45 jacks on the Guardian unit, creating ideal protection for Fax/Internet/Network users. Power surges can pass to the connected equipment through phones lines and network cables.

If you have any questions call us at our Tech Support line toll free 1-800-772-7633 or email us at support@smartpowersystems.com
Installation of TBFTM
1.Turn off and un-plug equipment to be protected from wall outlet. 2. Plug the equipment into the Guardian unit. 3. Plug the Guardian unit into grounded wall outlet. 4. Your equipment is now fully protected. Place the Guardian where monitoring lights
can be observed.

Installation for Protection for Telephone Line and Network Cable
TELEPHONE 1. Unplug the equipment's telephone cable from the wall jack and plug into the RJ11 "DEVICE"
on the Guardian. 2. Plug the provided telephone cable to the RJ11 jack "LINE" on the Guardian. 3. Plug the other end of the telephone cable into the RJ11 wall jack.
CAUTION: - Never install telephone wiring during a lightning storm. - Disconnect telephone line at the network interface before installing the secondary protector. - Intended for indoor use only.
Telephone Line Protection clamping voltage 250-350 vdc.

Installation for Protection for Network Cable
NETWORK 1. Unplug the equipment's network cable from the wall RJ45 network jack and plug into the RJ45
"DEVICE" on the Guardian. 2. Plug the provided CAT5 cable to the RJ45 jack "LINE" on the Guardian. 3. Plug the other end of the CAT5 cable into the wall RJ45 network jack. Your equipment is now
fully protected. Place the Guardian where monitoring lights can be observed.

Connected Equipment with Tel./Modem Jack
Phone Wall Jack

Power Cord Power Cord

Connected Equipment with Network Jack

Network Cord Network Jack/ HUB

LINE DEVICE

Network Cord

LINE

Phone Cord Phone Cord

DEVICE

Guardian Power Cord

Use the Standard CAT 5 Network Patch cord when using the Network protection RJ45 circuit.

GREEN LIGHT
The green light confirms properly the connected equipment is fully protected.
RED LIGHT
The RED light indicates over voltage, improper ground connection or reversed power wires which needs to be corrected. In an over voltage incident, power is disconnected to protect the connected equipment. Important: If the RED Light comes on, contact your electrician to inspect and correct the outlet wiring in order to receive the maximum protection for your connected equipment.
IMPORTANT: The Guardian is designed to be compatible with a GFCI (Ground Fault Circuit Interrupter), however, during plug in the GFCI might trip. Press the reset button to restart the circuit. Note: Do Not plug more than 3 Guardian products to a circuit that has a GFCI circuit breaker or GFCI wall outlets.

TRANSFORMER BASED FILTER SERIES (TBFTM) POWER FILTERS Considered to be one of the most significant developments in the power protection industry. TBFTM Filters contain innovative technology that combines Surge Suppression and Noise Isolation which filters the noise on the ground to less than 0.5 Volts (US Patent # 6229682). Exclusive "POVP" Prolonged Over Voltage Protector (US Patent # 6560086) disconnects the output power if voltage exceeds 155 volts. Exclusive Smart Technology (US Patent #5721661) protects microprocessor based equipment against reverse polarity or no ground. The patented TBFTM filters prevent 90% of the power problems experienced by your POS system, computer, copier and facsimile machine.
OTHER POWER PROTECTION PRODUCTS
AUTOMATIC VOLTAGE REGULATOR - AVR SERIES Regulates the voltage to protect equipment against voltage sags and brownouts. Electronic systems are designed to operate based on a clean and constant supply of AC voltage. Smart Power Systems' AVR line provides boost & buck capability to eliminate under or over voltage fluctuations.
UNINTERRUPTIBLE POWER SUPPLIES - UPS SERIES Smart Power Systems' Uninterruptible Power Supplies (UPS) integrated TBFTM Technology provide on-line power conditioning.
WARRANTY
Limited Lifetime Warranty All Guardian Filters are guaranteed free of defects in material or workmanship for the life to the original purchaser --or, they will be repaired or replaced free of charge. See our website for more details - www.smartpowersystems.com
$25,000 Connected Equipment Warranty If the Smart Power Systems equipment fails and this failure allows a surge to pass through and damage the connected equipment, Smart Power Systems will pay for the repair or replacement of the connected equipment of the original purchaser . Please take the time to register each Smart Power Systems' product along with the connected equipment devices connected to it within 10 days of date of purchase in order for you to take advantage of this product warranty and connected equipment protection policy. See our website for more details - www.smartpowersystems.com
IMPORTANT
If for any reason you need to return the Guardian unit to the manufacturer, you should obtain an RMA (Return Material Authorization) number before returning the unit. To request an RMA number please call 1-800-772-7633 or visit the website at www.smartpowersystems.com/main/rma.htm
UL 1449 3rd. Edition Listed
7409 Railhead Ln. - Houston, Texas 77086 - Tel:(713)464-8000 - Fax:(713)984-0841 E-mail: support@smartpowersystems.com - www.smartpowersystems.com

