Instructions for INKBIRD models including: IPT-2CH Smart Temperature Controller, IPT-2CH, Smart Temperature Controller, Temperature Controller

IPT-2CH-说明书(103.01.00227)-V8.0-20250320-大货文件(未转曲) - 电子版

IPT-2CH.English.Product.Manual

Download 4.0 – INKBIRD


File Info : application/pdf, 33 Pages, 2.85MB

PDF preview unavailable. Download the PDF instead.

IPT-2CH English Product Manual ?v=15981527690436729881
P2

P1

WORK1

WORK2

IPT-2CH

Smart Temperature
Controller Manual

Please keep this manual properly for reference. You can also scan the QR code below to visit our official website for product usage videos. For any usage issues, please feel free to contact us at support @inkbird.com.
Wenn Sie eine Bedienungsanleitung in deutscher Sprache benötigen, scannen Sie bitte den QR-Code und besuchen Sie unsere Website, um sie zu erhalten und ein Video über die Verwendung des Produkts zu sehen. Se avete bisogno di un manuale di istruzioni in italiano, scansionate il codice QR e visitate il nostro sito web per ottenerlo e vedere un video su come utilizzare il prodotto. Si vous avez besoin d'un mode d'emploi en français, veuillez scanner le code QR pour visiter notre site officiel afin d'obtenir et de visionner la vidéo d'utilisation du produit ! Als je een Nederlandstalige handleiding nodig hebt, scan dan de QR-code om naar onze officiële website te gaan en bekijk de video over het gebruik van het product! Si necesita el manual de instrucciones en español, escanee el código QR para ir a nuestro sitio web oficial y ver el vídeo sobre cómo utilizar el producto.

Warm tips
To quickly jump to a specific chapter page, click on the relevant text on the contents page.
You can also use the thumbnail or document outline in the top left corner to quickly find a specific page.

Contents

01 INTRODUCTION

CAUTION

1

Features

1

Technical Parameters

1

Product Layout

2

02 APP CONTROL

Download The App

3

Pair With Your Phone

3

Add Devices in SmartConfig Mode

4

Add Devices in AP Mode

5

03 OPERATING INSTRUCTIONS

Factory Reset

8

Quick Query of The Start Heating Temperature

9

Quick Setup of The ControllingTemperature

10

Temperature Unit Setting

11

Start Heating Temperature of P1 (ST1)

12

Stop Heating Temperature of P1 (SP1)

13

High Temperature Alarm of P1 (AH1)

14

Low Temperature Alarm of P1 (AL1)

14

The Setting of The P1 Calibration Value (CA1)

15

Start Heating Temperature of P2 (ST2)

16

Stop Heating Temperature of P2 (SP2)

17

High Temperature Alarm of P2 (AH2)

18

Low Temperature Alarm of P2 (AL2)

19

The Setting of The P2 Calibration Value (CA2)

20

Turn On/Off The Buzzer Sound Manually (ALM)

20

Temperature Display

21

Technical Assistance and Warranty

22

FCC Requirement

24

Troubleshooting Guide

25

INTRODUCTION
CAUTION
KEEP CHILDREN AWAY TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY INDOORS DO NOT PLUG INTO ANOTHER RELOCATABLE POWER TAPS OR AN EXTENSION CORD USE ONLY IN DRY LOCATION
Features
Plug-n-Play, easy to use. Dual relay control, controls two sets of outputs. Users can set different target temperatures according to different environments. Supports both Celsius and Fahrenheit units. LCD display, displays the testing temperature, the target temperature and the output state. Supports temperature calibration. Supports high/low temperature limit alarm. Supports probe abnormal alarm.
Technical Parameters
Power Input: 100~240Vac 50/60Hz Output: 100~240Vac 50/60Hz 500W Max Probe Type: R25=10K±1% R0=26.74~27.83K B25/85=3435K±1% Temperature Control Range: 0.0~45.0/32.0~113

Temperature Measurement Range: -5.0~50.0 /23.0~122
Temperature Display Accuracy: 0.1/ (T<100/), 1/ (100/)
Temperature Measurement Accuracy: ±1/±2 Temperature Unit: Celsius  or Fahrenheit  Operating Ambient Temperature: -20~60/-4~140 Storage Environment: -temperature range: 0~60/32~140 -humidity range: 20~80%RH (not frozen or condensation) Warranty: 2 years for the controller and 1 year for the probes
Product Layout
LCD: Display the Current Temperature, the WORK1 Stop Heating Temperature, the Heating Indicator of WORK1, the WORK2 Stop Heating Temperature, and the Heating Indicator of WORK2.

P2

P1

WORK1

WORK2

Probe Interfaces Buttons
WORK1/WORK2 Outputs

Tap "+" or "add device" in home page of the APP to add devices.
If the controller is in the normal working state, you can hold for 2 seconds to reset the Wi-Fi network, the device will enter the Smartconfig state by default, short press to switch between the Smartconfig mode and the AP mode.
If the Wi-Fi state changes, it will take about 5 seconds to display the corresponding LCD symbols and state due to the data processing of the Wi-Fi module.
Add Devices in SmartConfig Mode
Plug in the device and make sure that the device is in the Smartconfig state, the LCD symbol flashes rapidly in 250ms interval.
Click "Confirm indicator rapidly blink" and select a preferred Wi-Fi network.
Enter your Wi-Fi password and click "Confirm" to start connection.
The device only supports 2.4GHz Wi-Fi Networks.

Add Device

AP Mode

Cancel

Connecting Now

Power on the device and confirm that indicator light rapidly blinks

8%

How to make indicator rapidly blink Confirm indicator rapidly blink

Make sure your phone and device are as close to your router as possible
Searching for Device Registering device to the cloud Initializing your Device

Add Devices in AP Mode:
Plug in the device and make sure that the device is in the AP Configuration state, the LCD symbol flashes slowly in 1500ms interval.
Click "Confirm indicator slowly blink" and select a preferred Wi-Fi network, enter the password and click "Confirm" to start connection.
Click "Connect now" to go to your phone's WLAN setting page, select the "SmartLife-xxxx" to connect to the router.

Back

Add Device

cancel

Connect phone to device's wifi...

Power on the device and confirm that indicator light slowly blinks
How to make indicator slowly blink Confirm indicator slowly blink

WLAN
1.Open WLAN Settings
2.Back to the App and continue to add... Connect Now

Go back to the app and click "Done" when the device is successfully connected to the Wi-Fi network.
Then you can set and control the device via InkBird Pro app.

Device Name

IPT-2CH

Probe1 Current Temperature of Probe1
Start Heating Temperature of Probe1
Stop Heating Temperature of Probe1
Probe2 Current Temperature of Probe2
Start Heating Temperature of Probe2
Stop Heating Temperature of Probe2

1
69.3 

77.0

78.0

2

78.6 

77.0

78.0 

IPT-2CH

1
69.3 

77.0

78.0

2

78.6 

77.0

78.0

Device Information
Temp. Trend of Probe1 Setting Menu of Probe1 Work State of Probe1
Temp. Trend of Probe2 Setting Menu of Probe2 Work State of Probe2

Setting

Temperature Unit

Temperature Unit Switch  

Alarm Sound ON/OFF Setting Temperature

Alarm Sound

Setting temperature
77.0
Start Heating

78.0
Stop Heating

High Temperature Alarm Value
Low Temperature Alarm Value
Temperature Calibration

High Temperature Alarm Value 86.0

Low Temperature Alarm Value 82.0

Temperature Calibration

0.0

OPERATING INSTRUCTIONS
Factory Reset
Unplug the controller, then hold and plug in the power cord to reset the controller.
Display before the factory reset
Display after the factory reset
Note: The buzzer will beep a short sound to remind you that all the parameters have been restored to the default data.

Quick Query of The Start Heating Temperature
For example, the start heating temperature of P1 is 77.0°F and the stop heating temperature is 78.0°F; the start heating temperature of P2 is 80.0°F, and the stop heating temperature of P2 is 82.0°F. The device displays the stop heating temperature of P1 and P2 by default.
Press , the P1 SET TEMP. area will display the start heating temperature 77.0.
Press again, the P2 SET TEMP. area will display the start heating temperature 80.0.
The controller will return to normal display if there's no operation for 3 seconds, or you can press any button to return to normal display manually.

Quick Setup of The Controlling Temperature
For example, the start heating temperature of P1 is 77.0°F and the stop heating temperature is 78.0°F; the start heating temperature of P2 is 80.0°F, and the stop heating temperature of P2 is 82.0°F.
Press once, then the P1 SET TEMP 77.0 (the start heating temperature value) will flash.
Press or to adjust the start heating temperature value.
Press once, then the P1 SET TEMP 78.0 (the stop heating temperature value) will flash.
Press or to adjust the stop heating temperature value.
Press once, then the P2 SET TEMP 80.0 (the start heating temperature value) will flash.

Press or to adjust the start heating temperature value.
Press once, then the P2 SET TEMP 82.0 (the stop heating temperature value) will flash.
Press or to adjust the stop heating temperature value.
The controller will save the settings and exit automatically if there's no operation in 30 seconds, or you can hold for 2 seconds to exit settings manually.
Temperature Unit Setting
Hold for 2 seconds and press once again to enter the setting menu, then select CF.

Press or to select between  and . Note: The buzzer will beep a short sound to remind you that all the parameters have been restored to the default data.
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
Start Heating Temperature of P1(ST1)
Hold for 2 seconds and press once again to enter the setting menu, then select St1.
Short press or to adjust the setting values, hold or to adjust the setting values quickly.
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
When the current temperature of P1 is less than or equal to the start heating temperature of P1, WORK1 will turn on the output and the heating symbol will light up.

Stop Heating Temperature of P1(SP1)
Hold for 2 seconds and press once again to enter the setting menu, then select SP1.
Short press or to adjust the setting values, hold or to adjust the setting values quickly.
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
When the current temperature of P1 is greater than or equal to the stop heating temperature of P1, WORK1 will turn off the output and the heating symbol will go out.
Note: The minimum temperature difference value between ST1 and SP1 is 0.3/0.5. When both values of ST1 and SP1 are larger than or equal to 100, the minimum temperature difference value is 1.0.

High Temperature Alarm of P1(AH1)
Hold for 2 seconds and press once again to enter the setting menu, then select AH1.
Short press or to adjust the setting values, hold or to adjust the setting values quickly. For example 84.0
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
When the current temperature of P1 is greater than or equal to the high temperature alarm set value of P1, the high temperature alarm will be triggered, and AH will be displayed alternately with the current temperature.
Note: If ALM = ON, the buzzer will sound Bi-Bi-Biii when the high temperature alarm is triggered, and it will stop when the temperature returns to normal. You can also press any button to manually cancel the alarm.
Low Temperature Alarm of P1(AL1)
Hold for 2 seconds and press once again to enter the setting menu, then select AL1.

Short press or to adjust the low temperature alarm value, hold or to adjust the setting values quickly. For example 78.0.
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
When the current temperature of P1 is less than or equal to the low temperature alarm set value of P1, the low temperature alarm will be triggered, and AL will be displayed alternately with the current temperature.
Note: If ALM = ON, the buzzer will sound Bi-Bi-Biii when the low temperature alarm is triggered, and it will stop when the temperature returns to normal. You can also press any button to manually cancel the alarm.
The Setting of The P1 Calibration Value(CA1)
Hold for 2 seconds and press once again to enter the setting menu, then select CA1.

Short press or to adjust the setting values, hold  or to adjust the setting values quickly.
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
The current temperature of P2 is 74.3. After setting CA1 (the temperature calibration value of P1) to 0.3, the current temperature displays 74.6.
Start Heating Temperature of P2(ST2)
Hold for 2 seconds and press once again to enter the setting menu, then select ST2.
Short press or to adjust the setting values, hold or to adjust the setting values quickly.

The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
When the current temperature of P2 is less than or equal to the start heating temperature of P2, WORK2 will turn on the output and the heating symbol will light up.
Stop Heating Temperature of P2(SP2)
Hold for 2 seconds and press once again to enter the setting menu, then select SP2.
Short press or to adjust the setting values, hold . or to adjust the setting values quickly.
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
When the current temperature of P2 is greater than or equal to the stop heating temperature of P2, WORK2 will turn off the output and the heating symbol will go out.

Note: The minimum temperature difference value between ST2 and SP2 is 0.3/0.5. When both values of ST2 and SP2 are larger than or equal to 100, the minimum temperature difference value is 1.0.
High Temperature Alarm of P2(AH2)
Hold for 2 seconds and press once again to enter the setting menu, then select AH2.
Short press or to adjust the setting values, hold or to adjust the setting values quickly. For example 84.0
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
When the current temperature of P2 is greater than or equal to the high temperature alarm set value of P2, the high temperature alarm will be triggered, and AH will be displayed alternately with the current temperature.

Note: If ALM = ON, the buzzer will sound Bi-Bi-Biii when the high temperature alarm is triggered, and it will stop when the temperature returns to normal. You can also press any button to manually cancel the alarm.
Low Temperature Alarm of P2(AL2)
Hold for 2 seconds and press once again to enter the setting menu, then select AL2.
Short press or to adjust the setting values, hold or to adjust the setting values quickly. For example 78.0.
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
When the current temperature of P2 is less than or equal to the low temperature alarm set value of P2, the low temperature alarm will be triggered, and AL will be displayed alternately with the current temperature.
Note: If ALM = ON, the buzzer will sound Bi-Bi-Biii when the low temperature alarm is triggered, and it will stop when the temperature returns to normal. You can also press any button to manually cancel the alarm.

The Setting of The P2 Calibration Value(CA2)
Hold for 2 seconds and press once again to enter the setting menu, then select CA2.
Short press or to adjust the setting values, hold or to adjust the setting values quickly.
The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
The current temperature of P2 is 74.5. After setting CA2 (the temperature calibration value of P2) to -0.3, the current temperature displays 74.2.
Turn On/Off The Buzzer Sound Manually(ALM)
Users can choose whether to turn on the buzzer sound when the abnormal alarm is triggered according to their actual usage. If ON is selected, the buzzer will sound when the abnormal alarm is triggered; if OFF is selected, then the buzzer will not sound.
Hold for 2 seconds and press once again to enter the setting menu, then select ALM.

Press or to choose ON or OFF. The controller will save the settings and exit automatically if there's no operation in 60 seconds, or you can hold for 2 seconds to exit settings manually.
Temperature Display
The screen display when both probe1 and Probe2 are not inserted.
The screen display when only one probe of Probe1 and Probe2 is inserted into the controller.
or
The screen display when Probe1 and Probe2 are both inserted into the controller.

The screen display when Probe1 or Probe2 is abnormal and the ALM=ON. Note: The buzzer will sound at the same time.
or
Technical Assistance and Warranty
Technical Assistance If you have any problems installing or using this controller, please carefully and thoroughly review the instruction manual. If you require assistance, please write to us at support@inkbird.com. We will reply to your emails in 24 hours from Monday through Saturday. You can also visit our website www.inkbird.com to find the answers to the common technical questions.
Warranty INKBIRD TECH. C.L. warrants that products are free from defects in manufacturing, materials and workmanship for a period of 2 years from the date of retail purchase. The warranty does not cover defects or malfunction caused by misuse, abuse, or improper maintenance, failure to follow operating instructions or use with equipment with which it is not intended to be used. Also, the warranty will not apply to damage caused by unauthorized alteration, modification or repair of the product. Inkbird does not warrant or provide service or support for any third party products.

Annex 1: Setting Parameters

Icons Display Function

Setting Range

Default Setting

CF

CF

Temperature Unit Setting

C/F

F

ST1

St1

Start Heating 0.0j45.0 Temperature 1 32.0~113.0

25.0 77.0

SP1

SP1

Stop Heating 0.0j45.0 Temperature 1 32.0~113.0

26.0 78.0

High

-5.0j50.0 50.0

AH1 AH1 Temperature

Alarm Value 1 23.0~122 122

Low

-5.0j50.0 0.0

AL1 AL1 Temperature

Alarm Value 1 23.0~122 32.0

Temperature -4.9j4.9

CA1 CA1 Calibration Value 1

-9.9~9.9

0.0 0.0

ST2

St2

Start Heating 0.0j45.0 Temperature 2 32.0~113.0

25.0 77.0

SP2

SP2

Stop Heating 0.0j45.0 Temperature 2 32.0~113.0

26.0 78.0

High

-5.0j50.0 50.0

AH2

AH2

Temperature Alarm Value 2 23.0~122

122

Low

-5.0j50.0 0.0

AL2

AL2

Temperature Alarm Value 2 23.0~122

32.0

Temperature -4.9j4.9

CA2 CA2 Calibration

Value 2

-9.9~9.9

0.0 0.0

ALM

ALM

Turn on/off the buzzer sound

ON/OFF

ON

FCC Requirement
changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ­ Reorient or relocate the receiving antenna. ­ Increase the separation between the equipment and receiver. ­ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ­ Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
24

Troubleshooting Guide

Issues Causes Solutions

Can not connect to WIFI.

1. Incorrect phone settings. 2. Incorrect router settings. 3. Incorrect connection mode selection. 4. Device malfunction.

1. In the phone settings, all permissions for the INKBIRD app are turned on. The Bluetooth and location functions of the phone are turned on. 2. Please ensure that the router can transmit 2.4GHz wifi signal alone, and the mobile phone remains connected to the 2.4GHz wifi that can access the Internet. Please make sure the SSID of the 2.4GHz wifi is not hidden. The password is not empty. There is no limit on the number of connected devices to the router. If you are not sure whether the upper limit has been reached, please turn off 2-3 WIFI devices. Router settings are as follows: ·Wireless protocol: 802.11 b/g/n, but cannot be set to 11n only; ·Security mode: WPA/WPA2 ·Authentication type: AES ·Enable DHCP service ·No VPN service. 3. Select the correct WiFi mode in the app. If there are many WiFi products interfering nearby, please switch the device to slow flash (AP) mode to connect. If it still does not work, please contact customer service.

The

1. Water or

probe condensa-

reading tion enters

is

the probe.

incorrect. 2. The

probe is

placed in a

area with

poor

humidity

circulation.

3. The

probe is

damaged.

1. Adjust the position of the probe. 2. Use a dry cloth to clean. 3. If the probe is used in a high humidity environment, dry it using a hairdryer and then test it at room. 4. Check if the probe is intact. 5. If the deviation is small, use the CA function to calibrate.

25

Issues Causes Solutions

work1 output will not turn on.

1. Incorrect settings. 2. Incompatible heater. 3. Output malfunction.

1. The heater power used is within the 250W limit. If the limit is exceeded, it may damage the IPT-2CH. Due to the low power of the heater, it may take time to heat up, please be patient. The temperature of the environment also affects the heating speed of the heater. 2. The heater does not need to be switched on manually when it is powered on, it can heat up to the target temperature. It can be tested by connecting it directly to a power outlet. 3. The IPT-2CH is set up correctly. If the IPT-2CH and app show work1 is heating, but work1 does not work. Please test: · Plug the heater into the IPT-2CH work1 socket. · Disconnect the IPT-2CH from the power supply, press and hold the button, then release the button when the power is on. · It will go into test mode, please press the
button within three seconds, and the work1 output will be switched on. Please check if the heater of work1 is working. If it still does not work, please contact customer service.

work2 output will not turn on.

1. Incorrect settings. 2. Incompatible heater. 3. Output malfunction.

1. The heater power used is within the 250W limit. If the limit is exceeded, it may damage the IPT-2CH. Due to the low power of the heater, it may take time to heat up, please be patient. The temperature of the environment also affects the heating speed of the heater. 2. The heater does not need to be switched on manually when it is powered on, it can heat up to the target temperature. It can be tested by connecting it directly to a power outlet. 3. The IPT-2CH is set up correctly. If the IPT-2CH and app show work2 is heating, but work2 does not work. Please test: · Plug the heater into the IPT-2CH work2 socket.

26

Issues Causes Solutions

· Disconnect the IPT-2CH from the power supply, press and hold the button, then release the button when the power is on. · It will go into test mode, please press the
button within three seconds, the work2 output will be switched on. Please check if the heater of work2 is working. If it still does not work, please contact customer service.

work1 output will not turn off.

1. Incorrect settings. 2. heater power exceeds limit. 3. Output malfunction.

1. The heater power used is within the 250W limit. If the limit is exceeded, it may damage the IPT-2CH. Due to the low power of the heater, it may take time to heat up, please be patient. The temperature of the environment also affects the heating speed of the heater. 2. The heater does not need to be switched on manually when it is powered on, it can heat up to the target temperature. It can be tested by connecting it directly to a power outlet. 3. The IPT-2CH is set up correctly. If IPT-2CH and app show work1 heating off, but work1 still works. Please test: · Plug the heater into the work1 socket of the IPT-2CH. · Disconnect the IPT-2CH from the power supply, press and hold the button, then release the button when the power is on. · It will enter the test mode. At this time, the work1 and work2 outputs are not working. Please check if the heater of work1 is working. If it still does not work, please contact customer service.

27

Issues Causes Solutions

work2 output will not turn off.

1. Incorrect settings. 2. heater power exceeds limit. 3. Output malfunction.

1. The heater power used is within the 250W limit. If the limit is exceeded, it may damage the IPT-2CH. Due to the low power of the heater, it may take time to heat up, please be patient. The temperature of the environment also affects the heating speed of the heater. 2. The heater does not need to be switched on manually when it is powered on, it can heat up to the target temperature. It can be tested by connecting it directly to a power outlet. 3. The IPT-2CH is set up correctly. If IPT-2CH and the app show work2 heating off, but work2 still works. Please test: · Plug the heater into the work2 socket of the IPT-2CH. · Disconnect the IPT-2CH from the power supply, press and hold the button, then release the button when the power is on. · It will enter the test mode. At this time, the work1 and work2 outputs are not working. Please check if the heater of work2 is working. If it still does not work, please contact customer service.

28

Shenzhen Inkbird Technology Co., Ltd.
support@inkbird.com
Consignor: Shenzhen Inkbird Technology Co., Ltd. Office Address: Room 1803, Guowei Building, No.68 Guowei Road, Xianhu Community, Liantang, Luohu District, Shenzhen, China Manufacturer: Shenzhen Inkbird Technology Co., Ltd. Factory Address: Room 501, Building 138, No. 71, Yiqing Road, Xianhu Community, Liantang Street, Luohu District, Shenzhen, China

MADE IN CHINA DESIGNED BY INKBIRD

V8.0

