Instruction Manual for Lumineux models including: 430159-BL-MW Pebley Utility Round Bulkhead, 430159-BL-MW, Pebley Utility Round Bulkhead

Pebley Round 3.2 Instruction Manual - OCT 22

Amenity Pebley 430159-BL-MW Pebley Utility Round Bulkhead 12W 3CCT Microwave - Black | Lumineux UK

[PDF] Pebley Round 3.2 Instruction Manual - OCT 22 - Luckins

accordance with current building and IET wiring regulations. Pebley. Utility Round. 3CCT Bulkhead. 12W. Warranty. 5 YR.


File Info : application/pdf, 2 Pages, 868.24KB

PDF preview unavailable. Download the PDF instead.

87baa0ec-f757-403e-8d3f-d05ff23587b3
Pebley Utility Round 3CCT Bulkhead

IP66 3CCT
BESA

12W
5 YR
Warranty

Pebley Utility

Bulkhead

1
READ THESE INSTRUCTIONS THOROUGHLY BEFORE
INSTALLATION KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
IMPORTANT: This product must be installed
by a qualified electrician or competent person, and in accordance with current building and IET wiring regulations.

BOX CONTENTS

This lighting fixture has been properly

packed to avoid damage during

transit. Before commencing with the

installation carefully inspect the luminaire to confirm there is no

4

damage. DO NOT INSTALL if any

damage has occurred to the fixture

or any of its components.

· Light Fitting · Instruction Manual · Fixings

TOOLS REQUIRED

· Drill

· Screwdriver · Cable

INSTALLATION INSTRUCTIONS

on 2

3

Geartray

off

Twist-lock

5

6

3CCT Switchable

3000K 4000K 6000K

Electrical connection wiring

SL PL

Grommet

N

L - LIVE (SL) = Brown
- EARTH = Green/Yellow
N - NEUTRAL = Blue

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION.

WARNING: Risk of electric shock! Isolate the mains power before proceeding.
· Turn off the mains power before performing inspections, installation, or removal
· Verify that the supply voltage is correct by comparing it with the luminaire label information
· It is the installers responsibility to ensure installation is suitable for the total load of the luminaire(s). The supply cable, fuses/circuit brakers must be correctly rated for the electrical load and considering for any transient inrush currents that may occur
· Do not perform insulation strength or resistance tests on installed luminarie(s) connected

1. Remove the four screws securing the diffuser

2. Twist the locking tab to loosen and remove the

on

geartray.

3. Drill appropriately sized holes through your chosen

mounting points in the base

off

4. Install grommet to your chosen cable entry and pierce,

making a hole just large enough to make a tight fit

around the incoming mains cable. Carefully thread

cable through grommet and secure fitting in place

5. Wire as per diagram (5). Select colour temperature

(Please see overleaf for instructions on how to set all sensor versions and emergency)

6. Replace the geartray and twist the locking tab to
secure in place, then refit the diffuser and re-connect the mains supply

A
E
G

Manby Business Park, Manby, Lincolnshire, LN11 8UT Lumineux is a B&T Associates Ltd company.

Technical Helpline: +44 (0)1507 328031

www.lumineux.co.uk

Pebley Utility Round 3CCT Bulkhead

DISPOSAL
Disassembly instructions for end of life disposal available on website.
Disposal of Electronic Equipment WEEE Directive 2002/96/EC This product falls within the scope of the Waste Electrical & Electronic Equipment Directive (WEEE), which means the product should not be disposed of as normal household waste. Please recycle where facilities exist or check with your Local Authority. RoHS ­ All components and materials used in this product are RoHS 2002/95/EC compliant.
Specifications may change from time to time. The information contained in this leaflet is for guidance only and should not be considered as always accurate and should be treated as not representative.
WARRANTY
This luminaire is warranted for a period of 5 years from the date of purchase**. The backup battery pack in the emergency version is warranted for a period of 24 months. The warranty could be invalidated should the light fitting not be installed according to these instructions, outside the scope of the specification or the product has been altered or tampered with in any way. Please see website for terms and conditions.
PRODUCT TEMP SPECIFICATION
Standard -20 to +40ºC
Emergency 0 to +30ºC
Revision 3.2 - OCTOBER 2022

MICROWAVE SENSOR SETTINGS

PEBLEY BULKHEAD DIMENSIONS

Detection Range: This determines the effective range of the motion. Note that reducing the sensitivity will also narrow the detection range.
Hold Time Duration: This determines the time the fitting remains at 100% illumination following motion detection.
Daylight Setting: This setting holds off the 100% light output should there be sufficient daylight.
STANDARD ON/OFF SENSOR

Part No. Description Watts L (mm) W (mm) H (mm) Weight

430159WH

Pebley Round Bulkhead

12W

300

300

92

0.7Kg

430159BL

Pebley Round Bulkhead

12W

300

300

92

0.7Kg

DETECTION AREA

HOLD TIME

DAYLIGHT SENSOR

W

H

12 3

45 6

78 9

I ON ON ON 100% I ON ON ON 5s I ON ON ON 2Lux

II - ON ON 75% II - ON ON 30s II ON ON - 10Lux

III ON - ON 50% III ON - ON 90s III - ON - 25Lux

L

IV - - ON 25% IV - - ON 3min IV ON - - 50Lux

V - - - 10% V ON ON - 20min V - - - Disable

VI - - - 30min

STEP DIM DRIVER SETTINGS

DETECTION AREA 1
I ON 100% II - 50%

HOLD TIME 2 3
I ON ON 5S II ON - 90S III - ON 3min IV - - 10min

DAYLIGHT SENSOR 4 5
I ON ON Disable II ON - 30 Lux III - ON 15 Lux IV - - 5 Lux

STAND-BY PERIOD 6 7
I ON ON 0s II ON - 30s III - ON 10min IV - - +

STAND-BY DIM LEVEL
8 I ON 10% II _ 25%

* Do not change output current unless instructed or this will void warranty.

* OUTPUT CURRENT

S1 S2 S3

450mA ON ON ON

400mA ON - ON

380mA -

- ON

350mA - ON -

320mA ON -

-

300mA -

-

-

Installation Engineers Contact Details:

Name:

Tel:

Luminaire Reference / Location

Luminaire Details:

Full Recharge Duration 24 Hours Emergency Duration 3 Hours

Lamp Type LED

Wiring instructions for units equipped an with EMERGENCY function

Emergency lighting luminaries must be installed and maintained in accordance with the emergency lighting standard BS 5266-1
1. Connect incoming earth cable to `Earth' terminal on connector block.
2. Connect incoming neutral cable to `Neutral' terminal on connector block.
3. For the emergency unit to work correctly, please ensure that an uninterrupted permanent live feed is present and is connected directly to the `Permanent Live' terminal of the mains terminal block. Please ensure there are no switches, PIRs etc within the permanent live feed, constant switching of the emergency pack could result in premature battery failure.
4. Connect incoming switched live cable to the terminal marked "Switched Live"
NOTE: If there is no switch live feed and the unit has a microwave sensor, simply bridge across from the "Permanent Live" to the Switch Live" on the mains terminal block.
5. There should be a loose flying lead connected to the battery. This needs to be attached to the flying lead from the emergency control unit.
6. Following power up the green LED indicator should illuminate to indicate charging. If power to the unit is disrupted or isolated, the unit indicating green LED will switch off, triggering the emergency LEDs to illuminate.
7. Please allow 24 hours charge before first emergency test.

EMERGENCY FITTINGS ONLY.
EARTH CONNECTION REQUIRED.

N

SL PL

PL - PERMANENT LIVE = Black
L - LIVE (SL) = Brown
- EARTH = Green/Yellow
N - NEUTRAL = Blue

Type Test
Functional 1 Functional 2 Functional 3 Functional 4 Functional 5 Functional 6 Functional 7 Functional 8 Functional 9 Functional 10 Functional 11 3hr Duration 12

Year 1 Signed Date

ROUTINE TEST RECORD

Year 2

Year 3

Signed Date Signed Date

** Please see our website for more detailed information on warranty.

Year 4 Signed Date

Year 5 Signed Date
This product contains a light source of energy efficiency Class E.
Technical Helpline: +44 (0)1507 328031



References

Adobe PDF Library 17.0 Adobe InDesign 18.0 (Macintosh)