Instruction Manual for Lumineux models including: 430159-BL-MW Pebley Utility Round Bulkhead, 430159-BL-MW, Pebley Utility Round Bulkhead
Amenity Pebley 430159-BL-MW Pebley Utility Round Bulkhead 12W 3CCT Microwave - Black | Lumineux UK
accordance with current building and IET wiring regulations. Pebley. Utility Round. 3CCT Bulkhead. 12W. Warranty. 5 YR.
File Info : application/pdf, 2 Pages, 868.24KB
DocumentDocumentPebley Utility Round 3CCT Bulkhead IP66 3CCT BESA 12W 5 YR Warranty Pebley Utility Bulkhead 1 READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLATION KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. IMPORTANT: This product must be installed by a qualified electrician or competent person, and in accordance with current building and IET wiring regulations. BOX CONTENTS This lighting fixture has been properly packed to avoid damage during transit. Before commencing with the installation carefully inspect the luminaire to confirm there is no 4 damage. DO NOT INSTALL if any damage has occurred to the fixture or any of its components. · Light Fitting · Instruction Manual · Fixings TOOLS REQUIRED · Drill · Screwdriver · Cable INSTALLATION INSTRUCTIONS on 2 3 Geartray off Twist-lock 5 6 3CCT Switchable 3000K 4000K 6000K Electrical connection wiring SL PL Grommet N L - LIVE (SL) = Brown - EARTH = Green/Yellow N - NEUTRAL = Blue PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION. WARNING: Risk of electric shock! Isolate the mains power before proceeding. · Turn off the mains power before performing inspections, installation, or removal · Verify that the supply voltage is correct by comparing it with the luminaire label information · It is the installers responsibility to ensure installation is suitable for the total load of the luminaire(s). The supply cable, fuses/circuit brakers must be correctly rated for the electrical load and considering for any transient inrush currents that may occur · Do not perform insulation strength or resistance tests on installed luminarie(s) connected 1. Remove the four screws securing the diffuser 2. Twist the locking tab to loosen and remove the on geartray. 3. Drill appropriately sized holes through your chosen mounting points in the base off 4. Install grommet to your chosen cable entry and pierce, making a hole just large enough to make a tight fit around the incoming mains cable. Carefully thread cable through grommet and secure fitting in place 5. Wire as per diagram (5). Select colour temperature (Please see overleaf for instructions on how to set all sensor versions and emergency) 6. Replace the geartray and twist the locking tab to secure in place, then refit the diffuser and re-connect the mains supply A E G Manby Business Park, Manby, Lincolnshire, LN11 8UT Lumineux is a B&T Associates Ltd company. Technical Helpline: +44 (0)1507 328031 www.lumineux.co.uk Pebley Utility Round 3CCT Bulkhead DISPOSAL Disassembly instructions for end of life disposal available on website. Disposal of Electronic Equipment WEEE Directive 2002/96/EC This product falls within the scope of the Waste Electrical & Electronic Equipment Directive (WEEE), which means the product should not be disposed of as normal household waste. Please recycle where facilities exist or check with your Local Authority. RoHS All components and materials used in this product are RoHS 2002/95/EC compliant. Specifications may change from time to time. The information contained in this leaflet is for guidance only and should not be considered as always accurate and should be treated as not representative. WARRANTY This luminaire is warranted for a period of 5 years from the date of purchase**. The backup battery pack in the emergency version is warranted for a period of 24 months. The warranty could be invalidated should the light fitting not be installed according to these instructions, outside the scope of the specification or the product has been altered or tampered with in any way. Please see website for terms and conditions. PRODUCT TEMP SPECIFICATION Standard -20 to +40ºC Emergency 0 to +30ºC Revision 3.2 - OCTOBER 2022 MICROWAVE SENSOR SETTINGS PEBLEY BULKHEAD DIMENSIONS Detection Range: This determines the effective range of the motion. Note that reducing the sensitivity will also narrow the detection range. Hold Time Duration: This determines the time the fitting remains at 100% illumination following motion detection. Daylight Setting: This setting holds off the 100% light output should there be sufficient daylight. STANDARD ON/OFF SENSOR Part No. Description Watts L (mm) W (mm) H (mm) Weight 430159WH Pebley Round Bulkhead 12W 300 300 92 0.7Kg 430159BL Pebley Round Bulkhead 12W 300 300 92 0.7Kg DETECTION AREA HOLD TIME DAYLIGHT SENSOR W H 12 3 45 6 78 9 I ON ON ON 100% I ON ON ON 5s I ON ON ON 2Lux II - ON ON 75% II - ON ON 30s II ON ON - 10Lux III ON - ON 50% III ON - ON 90s III - ON - 25Lux L IV - - ON 25% IV - - ON 3min IV ON - - 50Lux V - - - 10% V ON ON - 20min V - - - Disable VI - - - 30min STEP DIM DRIVER SETTINGS DETECTION AREA 1 I ON 100% II - 50% HOLD TIME 2 3 I ON ON 5S II ON - 90S III - ON 3min IV - - 10min DAYLIGHT SENSOR 4 5 I ON ON Disable II ON - 30 Lux III - ON 15 Lux IV - - 5 Lux STAND-BY PERIOD 6 7 I ON ON 0s II ON - 30s III - ON 10min IV - - + STAND-BY DIM LEVEL 8 I ON 10% II _ 25% * Do not change output current unless instructed or this will void warranty. * OUTPUT CURRENT S1 S2 S3 450mA ON ON ON 400mA ON - ON 380mA - - ON 350mA - ON - 320mA ON - - 300mA - - - Installation Engineers Contact Details: Name: Tel: Luminaire Reference / Location Luminaire Details: Full Recharge Duration 24 Hours Emergency Duration 3 Hours Lamp Type LED Wiring instructions for units equipped an with EMERGENCY function Emergency lighting luminaries must be installed and maintained in accordance with the emergency lighting standard BS 5266-1 1. Connect incoming earth cable to `Earth' terminal on connector block. 2. Connect incoming neutral cable to `Neutral' terminal on connector block. 3. For the emergency unit to work correctly, please ensure that an uninterrupted permanent live feed is present and is connected directly to the `Permanent Live' terminal of the mains terminal block. Please ensure there are no switches, PIRs etc within the permanent live feed, constant switching of the emergency pack could result in premature battery failure. 4. Connect incoming switched live cable to the terminal marked "Switched Live" NOTE: If there is no switch live feed and the unit has a microwave sensor, simply bridge across from the "Permanent Live" to the Switch Live" on the mains terminal block. 5. There should be a loose flying lead connected to the battery. This needs to be attached to the flying lead from the emergency control unit. 6. Following power up the green LED indicator should illuminate to indicate charging. If power to the unit is disrupted or isolated, the unit indicating green LED will switch off, triggering the emergency LEDs to illuminate. 7. Please allow 24 hours charge before first emergency test. EMERGENCY FITTINGS ONLY. EARTH CONNECTION REQUIRED. N SL PL PL - PERMANENT LIVE = Black L - LIVE (SL) = Brown - EARTH = Green/Yellow N - NEUTRAL = Blue Type Test Functional 1 Functional 2 Functional 3 Functional 4 Functional 5 Functional 6 Functional 7 Functional 8 Functional 9 Functional 10 Functional 11 3hr Duration 12 Year 1 Signed Date ROUTINE TEST RECORD Year 2 Year 3 Signed Date Signed Date ** Please see our website for more detailed information on warranty. Year 4 Signed Date Year 5 Signed Date This product contains a light source of energy efficiency Class E. Technical Helpline: +44 (0)1507 328031