STREETLIGHT URBAN VLA RETROFIT

Brand: LEDVANCE

Product Overview

The LEDVANCE Streetlight Urban VLA Retrofit series offers efficient and reliable lighting solutions for urban environments. These luminaires are designed for retrofitting existing installations, providing modern performance with ease of integration.

Technical Specifications - General

Product NameEANDimensions (L x W x H [mm])Power (W)Voltage (VAC)Frequency (Hz)Luminous Flux (Im)Efficacy (Im/W)
URBAN VLA RET P 40W 722 SYM1404099854609367320x320x13440220-240V50/60 Hz4800120
URBAN VLA RET P 40W 730 SYM1404099854609374320x320x13440220-240V50/60 Hz5200130
URBAN VLA RET P 40W 722 A50X1504099854609381320x320x13440220-240V50/60 Hz4800120
URBAN VLA RET P 40W 730 A50X1504099854609398320x320x13440220-240V50/60 Hz5200130
URBAN VLA RET P 40W 722 A60X1204099854609404320x320x13440220-240V50/60 Hz4800120
URBAN VLA RET P 40W 730 A60X1204099854609411320x320x13440220-240V50/60 Hz5200130
URBAN VLA RET P 60W 722 SYM1404099854609428320x320x13460220-240V50/60 Hz7200120
URBAN VLA RET P 60W 730 SYM1404099854609435320x320x13460220-240V50/60 Hz8100135
URBAN VLA RET P 60W 722 A50X1504099854609442320x320x13460220-240V50/60 Hz7200120
URBAN VLA RET P 60W 730 A50X1504099854609459320x320x13460220-240V50/60 Hz8100135
URBAN VLA RET P 60W 722 A60X1204099854609466320x320x13460220-240V50/60 Hz7200120
URBAN VLA RET P 60W 730 A60X1204099854609473320x320x13460220-240V50/60 Hz8100135

Technical Specifications - Performance & Durability

Product NameEANIngress Protection (IP)Impact Protection (IK)Color Rendering Index (Ra)Operating Temperature (°C)Power Factor (PF)Weight (kg)
URBAN VLA RET P 40W 722 SYM14040998546093676608> 70-20...45> 0.94.4 kg
URBAN VLA RET P 40W 730 SYM14040998546093746608> 70-20...45> 0.94.4kg
URBAN VLA RET P 40W 722 A50X15040998546093816608> 70-20...45> 0.94.4 kg
URBAN VLA RET P 40W 730 A50X15040998546093986608> 70-20...45> 0.94.4 kg
URBAN VLA RET P 40W 722 A60X12040998546094046608> 70-20...45> 0.94.4 kg
URBAN VLA RET P 40W 730 A60X12040998546094116608> 70-20...45> 0.94.4 kg
URBAN VLA RET P 60W 722 SYM14040998546094286608> 70-20...45> 0.94.4kg
URBAN VLA RET P 60W 730 SYM14040998546094356608> 70-20...45> 0.94.4kg
URBAN VLA RET P 60W 722 A50X15040998546094426608> 70-20...45> 0.94.4 kg
URBAN VLA RET P 60W 730 A50X15040998546094596608> 70-20...45> 0.94.4 kg
URBAN VLA RET P 60W 722 A60X12040998546094666608> 70-20...45> 0.94.4 kg
URBAN VLA RET P 60W 730 A60X12040998546094736608> 70-20...45> 0.94.4 kg

Note: Blank cells in the table indicate that the data was not specified for those particular product variants in the source document.

Installation Guide

  1. Step 1: Safety First

    Ensure the power supply is switched OFF before commencing installation. A warning symbol [electrical hazard] is indicated, with a hand shown operating a switch from ON to OFF.

  2. Step 2: Luminaire Mounting

    Mount the luminaire body to the base. This involves using four M10 screws. A [screwdriver] icon indicates the tool required.

  3. Step 3: Electrical Connection

    Connect the electrical wires. The diagram indicates that the wiring should accommodate 2 or 3 conductors with cross-sections ranging from 0.75mm² to 2.5mm², for cables with diameters between ø8mm and ø14mm.

  4. Step 4: Securing the Driver

    Secure the internal driver or gear tray. Use four M10 screws, tightened to a torque of 3 Nm. A [screwdriver] icon indicates the tool required.

  5. Step 5: Mounting Dimensions

    The luminaire has different mounting dimensions depending on the model. One version requires a mounting space of 427mm, while another requires 347mm. Arrows indicate the measurement points for these dimensions.

  6. Step 6: Final Power Activation

    Once installation is complete, ensure all switches are in the ON position to activate the luminaire. A hand is shown operating multiple ON/OFF switches.

Electrical Characteristics - Circuit Breaker Compatibility

Product NameInrush Current [A]Th50 [µs]B10B16B25B32C10C16C25C32
URBAN VLA RET P 40W 722 SYM14018.78304712158122025
URBAN VLA RET P 40W 730 SYM140
URBAN VLA RET P 40W 722 A50X150
URBAN VLA RET P 40W 730 A50X150
URBAN VLA RET P 40W 722 A60X120
URBAN VLA RET P 40W 730 A60X120
URBAN VLA RET P 60W 722 SYM14045.91281422354522365773
URBAN VLA RET P 60W 730 SYM140
URBAN VLA RET P 60W 722 A50X150
URBAN VLA RET P 60W 730 A50X150
URBAN VLA RET P 60W 722 A60X120
URBAN VLA RET P 60W 730 A60X120

Note: Blank cells in the table indicate that the data was not specified for those particular product variants in the source document.

Compliance and Recycling Information

This product complies with various standards and regulations:

Recycling Information:

Additional symbols indicate energy efficiency, electrical safety, and proper waste disposal (crossed-out wheeled bin).

Manufacturer Information

LEDVANCE SASU
CQM, 5 rue d'Altorf
67120 Molsheim France
www.ledvance.com

LEDVANCE Ltd
Sterling House, 810 Mandarin Court, Warrington,
Cheshire, WA1 1GG, United Kingdom

PDF preview unavailable. Download the PDF instead.

v1 Adobe PDF Library 17.0 Adobe InDesign 18.5 (Macintosh)

Related Documents

Preview LEDVANCE STREETLIGHT URBAN FDO Installation Guide and Specifications
Comprehensive guide to the LEDVANCE STREETLIGHT URBAN FDO, including technical specifications, installation instructions, electrical characteristics, and product details. Learn about power ratings, luminous flux, IP/IK ratings, and installation procedures for this outdoor lighting fixture.
Preview LEDVANCE FLOODLIGHT GEN4: Technical Specifications and Installation Guide
Comprehensive technical specifications, product details, and installation instructions for the LEDVANCE FLOODLIGHT GEN4 series, covering various wattages, lumen outputs, and color temperatures.
Preview LEDVANCE Urban Wallpack: Technical Specifications and Installation Guide
Comprehensive technical specifications, performance data, and installation instructions for the LEDVANCE Urban Wallpack luminaires, including models P 20W and P 40W. Features include dimensions, electrical data, IP/IK ratings, and dimming performance.
Preview LEDVANCE App Download Guide
Instructions for downloading and using the LEDVANCE app for smart lighting control, including app compatibility with different LEDVANCE products.
Preview LEDVANCE Area Flood 5A Luminaires: Wattage Selectable, High Efficiency Outdoor Lighting
Discover the LEDVANCE Area Flood 5A luminaires, offering selectable wattage and lumen outputs, up to 140 LPW, DLC 5.1 Premium compliance, and versatile installation options for efficient outdoor area lighting. Features include motion/daylight sensors and LEDVANCE LINK™ Bluetooth® compatibility.
Preview LEDVANCE SL ECO SOLAR E - Product Specifications and Installation Guide
Comprehensive details on the LEDVANCE SL ECO SOLAR E series, including technical specifications, dimensions, performance data, and installation guidance for various models.
Preview Urban Lantern LED Lighting Solutions
Discover the Urban Lantern series by LEDVANCE, offering energy-efficient LED lighting solutions for urban environments. Explore different models, specifications, and energy efficiency classes.
Preview LED Tube T8 EM Ultra Output S Installation and Operation Guide
Comprehensive guide for the installation and operation of the LEDVANCE LED Tube T8 EM Ultra Output S, covering retrofit and conversion installations, technical specifications, and safety information.