BLAUBERG Ventilatoren
blaubergventilation.com.au
Turbo 150 T
Mixed-flow inline fans
Key Features
- Sound pressure level LpA at 3 m: 44 dB(A)
- Motor type: AC
- Control: Speed switch
- Impeller type: Mixed-flow
- Casing material: Plastik
- Installation in any position
- Cable with mains plug
- Timer: Turn off timer
Technical Specifications
Parameter | Unit of measurement | Turbo 150 T |
---|---|---|
Connected air duct size | mm | 150 |
Speed | - | 2 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 42 / 50 |
Unit current | A | 0.19 / 0.22 |
Maximum airflow | m³/h | 415 / 565 |
Rotation speed at 50hz | - | - |
Sound pressure level LpA at 3 m | dB(A) | 32 / 44 |
Weight | kg | 2.95 |
Transported air temperature (max) | °C | 60 |
Ambient air temperature min | °C | 0 |
Ambient air temperature max | °C | 0 |
Ingress protection rating | - | IPX4 |
Ingress protection rating of the drive | - | IPX4 |
Performance Curves
The following performance curves illustrate the fan's behavior under different operating conditions.
Static Pressure vs. Airflow
This graph shows the static pressure (in Pascals) generated by the fan relative to the airflow rate (in m³/h). Two distinct curves, labeled 'speed_1' and 'speed_2', represent performance at different speed settings. The static pressure is highest at low airflow rates and decreases as airflow increases.
Power Consumption vs. Airflow
This graph displays the electrical power consumed by the fan (in Watts) as a function of airflow rate (in m³/h). Similar to the pressure curve, it features two lines for 'speed_1' and 'speed_2'. Power consumption generally increases with airflow rate.
Dimensions
The fan has a cylindrical body with inlet and outlet spigots. Key dimensions are indicated in the diagram:
- ØD: Diameter of the main connection spigot.
- ØD1: Diameter of the motor housing/connection.
- B: Width of the fan body.
- H: Height of the fan body.
- L: Length of the fan body.
ØD (mm) | ØD1 (mm) | B (mm) | H (mm) | L (mm) |
---|---|---|---|---|
148 | 187 | 220 | 251 | 289 |
Ecodesign Information
Parameter | Ecodesign Data | |||||
---|---|---|---|---|---|---|
Cold | Average | Warm | ||||
Trademark | Blauberg | |||||
Model | Turbo 150 T | |||||
Specific energy consumption (SEC) (kWh/(m²/a)) | 53.8 | A+ | 26.7 | B | 11.2 | E |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m³/h) | 500 | |||||
Electric power input (W) | 50 | |||||
Reference flow rate (m³/s) | 0.097 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m³/h)) | 0.12 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 66 | |||||
The annual electricity consumption (AEC) (kWh/a) | 64 | 64 | 64 | |||
The annual heating saved (AHS) (kWh/a) | 5536 | 2830 | 1280 |