SUPREME

NERA

Installation & maintenance instructions.

General Information

Warnings

Operating Instructions and Parts Manual

Please read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.

Supreme NERA Lever Time Flow Tap

Supreme time flow commercial tapware. Water efficient and reliable lever operation enables effortless control, making it especially accessible for the elderly and those with reduced physical abilities. Lead free, brass composition.

Specifications

FinishChrome plated over lead free brass
Water Temperature5-70°C for cold or premixed water (lead free thermostatic mixing valve available)
ControlLever mechanical activation
Operating Pressure50 kPa - 600 kPa / 0.5-6.0 bar (Recommended 2-4 bar)
Rate of Flow4l/min - Flow strainer in stem
Time of Flow8-12 seconds
Water Inlet ConnectionMale threaded stem G 1/2"
DimensionsHeight 191mm, Depth 138mm, Tap Ø 46mm, Lever Ø 12mm, Hole Ø 35mm, Nosing 104mm, Discharge height 47mm
Warranty24 Months

Planning

Tempered Water

Components

Fig 1: Shows the tap assembly components, including a shaped gasket (D 40 X 21 X 2.5) and a 1/2" flanged nut.

Faucet Installation

Fig 2: Illustrates the tap's threaded stem being passed through a hole (G1/2") in a mounting surface.

Fig 3: Depicts the underside of the mounting surface with the gasket and flanged nut being fitted and tightened.

Fig 4: Shows a flexible hose connection (FLEX G1/2"/G1/2", not provided) being attached.

Fig 5: Illustrates the flexible hose connected to a 1/2" angle valve.

Fig 6: Shows the fully installed tap on a wall-mounted basin, with water flowing from the spout.

Faucet Installation Steps

  1. Install 1/2" angle valve, stop cock or equivalent.
  2. Flush lines thoroughly to pass any debris.
  3. Cut hole in mounting surface (if required): Ø 25mm min - Ø 35mm max.
  4. Pass threaded stem through top of mounting surface (refer to Fig 2).
  5. NOTE: Seal with silicon if required to create waterproof seal between the tap and mounting surface.

  6. On the underside of the mounting surface fit the gasket and flanged nut. Tighten (refer to Fig 3).
  7. Connect stainless flex (not provided) (refer to Fig 4).
  8. Connect flex to 1/2" angle valve (refer to Fig 5).
  9. Turn on water supply and check all connections. Activate the tap several times to stabilise flow time (refer to Fig 6).
  10. NOTE: Within normal water pressure ranges, the tap will self-regulate to flow for 8-12 seconds once the button is pushed.

Important

The installer is required to ensure the waterproof seal is appropriate between the tap and the mounting surface. If in doubt regarding the seal, install with a suitable silicon. In addition, the recessing area must be waterproof and have a drainage point, to eliminate potential water ingress.

Troubleshooting

SymptomPossible CauseCorrective Action
Water dribbles or tricklesa. Debris or hard water buildup in cartridgea. Remove cartridge and clean internals including seals and time delay cups with a soft cloth & pin on internal groove. b. Replace if damaged (cartridge).
Water flows too long or continual flowa. Build up of foreign material or worn seal/seat
b. Incorrect time delay cup installed
a. Remove cartridge and clean as per above. Check lip seal and seat are in good condition. Replace cartridge if damaged.
b. Install different time delay cup 4/6 sec, 8/12sec, 12/16sec.
Water doesn't flow long enougha. Pressure too low?
b. Aerator blocked?
c. Incorrect time delay cup installed
a. Check pressure; 2 - 4bar recommended.
b. Remove aerator and clean.
c. Install different time delay cup as above.
Water temperature too cold/hot (if tempered)a. Source of hot/cold water and piping arrangement
b. Pressure of hot water source
c. Incorrect setting on TMV
a. Check source and pressure of hot and cold water.
b. Eg. continuous water heater pressure. Balance the hot and cold pressure.
c. Adjust mixed temperature on TMV.

Maintenance

This product due to its design may need some maintenance. The regularity of this will depend on its usage and the water type. If in a hard water area maintenance may be required more often.

To maintain good working order, it is recommended to clean out the white plastic cup inside the tap/mixer, specifically the fine internal groove.

  1. To do this first turn off water supply.
  2. Remove handle/valve using a spanner.
  3. The valve will then pull from the tap/mixer.
  4. The white plastic cup may come away with the valve, if not simply remove it by pulling it from the body.
  5. Once removed, clean out cup and run down the groove using a pin to clear out dirt.
  6. When thoroughly cleaned, replace cup, valve and tighten.

Supreme Comprehensive Warranty

Your Supreme time flow tapware is fully guaranteed against defective materials and faulty workmanship commencing from the date of sale (according to SPL's records), subject to it being installed and maintained in accordance with the manufacturer's instructions.

SPL (2021) Limited warrants that should any part of the tap fail within the given warranty period (24 months), it will be remedied by SPL. The tap should be returned to SPL (2021) Limited for all warranty claims. The cost of cartage will be payable by the customer.

Due to the significant variation in tradesman's knowledge, experience, and productivity, labour charges will NOT be accepted unconditionally. We strongly recommend contacting our office for advice before proceeding with any warranty repairs.

This warranty excludes:

This warranty does not displace any statutory warranty in relation to the tap but any liability of SPL (2021) Limited under any statutory warranty will be limited to a replacement or repair of the tap or payment of the cost of such replacement or repair at the sole discretion of SPL (2021) Limited.

Note:

SPL Limited
Cambridge 3434
New Zealand

p. +64 7 823 5790
e. office@splwashrooms.co.nz

Models: NERA, SUPREME NERA Lever Time Flow Tap, SUPREME NERA, Lever Time Flow Tap, Time Flow Tap, Flow Tap, Tap

File Info : application/pdf, 12 Pages, 529.53KB

PDF preview unavailable. Download the PDF instead.

Supreme-Nera-Time-Flow-Installation-1

References

GPL Ghostscript 9.55.0 Adobe InDesign 19.5 (Windows)

Related Documents

Preview Supreme Garda Time Flow Tap Installation and Maintenance Guide
Comprehensive installation, troubleshooting, and maintenance instructions for the Supreme Garda Time Flow Tapware, including specifications and warranty information from SPL.
Preview Supreme BA101 Hand Dryer: Installation, Maintenance, and Warranty Guide
Comprehensive installation, maintenance, and warranty guide for the Supreme BA101 hand dryer by SPL. Learn about safety, specifications, mounting, troubleshooting, and product care.
Preview Supreme BA101 Hand Dryer: Installation, Maintenance, and Warranty Guide
Comprehensive guide for installing, maintaining, and troubleshooting the Supreme BA101 hand dryer. Includes safety information, specifications, mounting heights, and warranty details from SPL Limited.
Preview vivo X100 Pro 5G Experience Event Terms and Conditions
Official terms and conditions for the vivo X100 Pro 5G new phone experience event hosted by SUPREME. Details include participation requirements, event schedule, location, data handling, and organizer's rights.
Preview Supreme ANABAS audio GP-N3S Portable Record Player Operating Manual
Comprehensive operating manual for the Supreme ANABAS audio GP-N3S portable record player, covering safety instructions, features, setup, operation, Bluetooth connectivity, maintenance, specifications, and troubleshooting.