Instruction Manual for POLAR models including: CD080-A, CD081-A, CD082-A, CD083-A, CD084-A, CD085-A, CD610-A, CD611-A, CD612-A, CD613-A, CD614-A, CD615-A, GL185-A, GL185-A Refrigerators Freezers, GL185-A, Refrigerators Freezers, Freezers

Instruction manual - Nisbets

04 Nov 2024 — The defrost cycle will end automatically. Storing Food. To get the best results from your POLAR appliance, follow these instructions: • Only ...

Download User Manual

Polar C-Series Stainless Steel Under Counter Freezer 140Ltr - CD081-A - Nisbets


File Info : application/pdf, 20 Pages, 1.36MB

PDF preview unavailable. Download the PDF instead.

user manual 600-400-150l series2
600 / 400 / 150 litre series Refrigerators/Freezers
Instruction manual

Model:
CD080-A/CD081-A/CD082-A/CD083-A/CD084-A/CD085-A/ CD610-A/CD611-A/CD612-A/CD613-A/CD614-A/CD615-A/
GL185-A

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



EN

Telephone Helpline: 1300225960

Safety Instructions

· DO NOT allow oil or fat to

· Position on a flat, stable

come into contact with the

surface.

plastic components or door

· A service agent/qualified

seal. Clean immediately if

technician should carry out

contact occurs.

installation and any repairs · DO NOT store products on

if required. Do not remove

top of the appliance.

any components or service · Bottles that contain a high

panels on this product.

percentage of alcohol

- In Queensland the

must be sealed and placed

service agent/qualified

vertically in the refrigerator.

technician MUST hold a · Always carry, store and

Gas Work Authorisation or handle the appliance in a

License for hydrocarbon

vertical position and move

refrigerants if the

by holding the base of the

appliance gas system is

appliance.

being opened or charged. · Always switch off and

· Consult Local and National

disconnect the power supply

Standards to comply with the

to the unit before cleaning.

following:

· Keep all packaging away

- Health and Safety at Work

from children. Dispose of

Legislation

the packaging in accordance

- Fire Precautions

with the regulations of local

- Wiring Regulations

authorities.

- Building Regulations

· If the power cord is damaged,

· DO NOT use jet/pressure

it must be replaced by a POLAR

washers to clean the

agent or a recommended

appliance.

qualified technician in order to

· DO NOT use the appliance

avoid a hazard.

outside.

· Children should be

· DO NOT use this appliance

supervised to ensure that

to store medical supplies.

they do not play with the

appliance.

2

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Telephone Helpline: 1300225960

AENU

· This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
· POLAR recommend that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to: Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity and Functional Testing.

Caution: Risk of Fire · Do not store explosive substances such as aerosol
cans with a flammable propellant in this appliance.
Warning: Keep all ventilation openings clear of obstruction. Unit should not be boxed in without adequate ventilation.
· To comply with AS/NZS 60079.10.1:2009: Ensure there are not sources of ignition in any area where refrigerant could gather in the event of a leak.
· Electrical equipment should not be placed under the vent or where refrigerant could gather in the event of a leak.
· Warning: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
· Warning: Do not damage the refrigerant circuit. · Warning: Do not use electrical appliances inside the food
storage compartments of the appliance.

Product Description
· CD080-A - 150 litre Refrigerator · CD081-A - 140 litre Freezer · CD082-A - 400 litre Refrigerator · CD083-A - 365 litre Freezer · CD084-A - 600 litre Refrigerator · CD085-A - 600 litre Freezer

· CD613-A - 365 litre Freezer · CD614-A - 600 litre Refrigerator · CD615-A - 600 litre Freezer · CD610-A - 150 litre Refrigerator · CD611-A - 140 litre Freezer · CD612-A - 400 litre Refrigerator · GL185-A - 522 litre Bakery Refrigerator

3

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



EN

Telephone Helpline: 1300225960

Introduction
Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.

Pack Contents

The following is included:

· POLAR Refrigerator / Freezer

· Tray Guides - Bakery refrigerator only

· Shelves - Refrigerator only

GL185-A x 12

CD610-A/ CD080-A x 3

· Keys x 2

CD612-A/ CD082-A x 4

· Spacers x 2

CD614-A x 4/ CD084-A

· Instruction Manual

· Door handle assembly

POLAR prides itself on quality and service, ensuring that at the time of unpacking the contents are supplied fully functional and free of damage. Should you find any damage as a result of transit, please contact your POLAR dealer immediately.

Installation
Note: A bracket is used to support the door during transportation. On receipt please remove the bracket.
Note: Not for use in vans or trailers, food trucks or similar vehicles. If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation. If in doubt allow to stand.
1. Remove the appliance from the packaging. Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces.
2. To optimize performance and longevity, ensure a minimum clearance of 2.5cm is maintained between the unit and walls and other objects, with a minimum 20cm clearance on the top. NEVER LOCATE NEXT TO A HEAT SOURCE.
Note: Before using the appliance for the first time, clean the shelves and interior with soapy water then dry well. The appliance is supplied with feet by default. However, castors can be supplied as an option.

Reversing the door
Depending on the location of the appliance, it may be necessary to change the direction the door opens by changing the side of the door handle. (Tip: Images in this section are for illustration only and may slightly differ from the actual appliance appearances.) To reverse the door handle: 1. The door handle is on the left side. Disassemble the right lower hinge.
Door handle

4 $%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Telephone Helpline: 1300225960
2. Remove the door from the right upper hinge. Then remove the hinge sleeve from the door top.

AENU
4. Reverse the door and hang it onto the left upper hinge.

Door handle

3. Remove the right upper hinge and install it on the left side. Afterwards, install the hinge sleeve onto the hinge.

5. Remove the pre-mounted screws on the left lower side.

6. Install the previously removed right lower hinge on the left side.

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC

5 

EN

Telephone Helpline: 1300225960

7. Secure the hinge in place using the previously removed screws.
8. Now the door handle is installed on the right side.

Manual Defrost
Press and hold the defrost button "aux" for 2 seconds to begin a manual defrost. The defrost light illuminates.
The defrost cycle will end automatically.
Storing Food
To get the best results from your POLAR appliance, follow these instructions:
· Only store foodstuffs in the appliance when it has reached the correct operating temperature.
· Do not place uncovered items as below inside the appliance, as this can lead to a damaged and leaking evaporator, and thus void your warranty: hot food, hot liquids, acidic fluids, acidic products.
· Wrap or cover food where possible. · Do not obstruct the fans inside the appliance. · Avoid opening the doors for prolonged periods
of time.
Lock/Unlock the Doors
· A lock is fitted to the doors to ensure foodstuffs are kept secure within your POLAR appliance.
· Use the keys provided to lock/unlock the door.

Operation
Control Panel
The control panel is located on the front of the appliance.

Turn On
1. Close the door of the appliance. 2. Connect the appliance to a mains power
supply.

Set the Operating Temperature

1. Press the SET button for 3 seconds. The

display will flash.

2. Press the

or

buttons to display the

required temperature.

3. Press the SET button to store the temperature.

Cleaning, Care &
Maintenance
· Switch off and disconnect from the power supply before cleaning.
· Clean the interior of the appliance as often as possible.
· Do not use abrasive cleaning agents. These can leave harmful residues.
· Clean the door seal with warm soapy water. · Always wipe dry after cleaning. · Do not allow water used in cleaning to run
through the drain hole into the evaporation pan. · Take care when cleaning the rear of the appliance. Sharp edges can cut.
Refrigerating tips:
· Condensation and ice will form with frequent and prolonged opening of the doors.
· Operating outside of the recommend temperature range and placing next to a heat source will also increase the amount of ice and internal/external condensation. If external condensation occurs wipe the surface down with a cloth.

6

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Telephone Helpline: 1300225960

AENU

· Excessive ice will result in longer running times that will increase energy consumption and increase the deterioration of components.
· If the gasket or seal is damaged or deformed, energy consumption will increase. To restore efficiency, replace gasket.
· Do not obstruct fans and do not exceed max load lines, as doing so will impact air distribution and increase energy usage.

Cleaning the Condenser
Periodically cleaning the condenser can extend the life of the appliance. POLAR recommend that a POLAR agent or qualified technician should clean the condenser. Failure to clean the condenser will increase energy consumption, reduce the performance and life of your Polar unit, and thus may invalidate your warranty.

Troubleshooting
A qualified technician must carry out repairs if required.

Fault

Probable Cause

Solution

The appliance is The unit is not switched on not working

Check the unit is plugged in correctly and switched on

Plug or lead is damaged

Replace Plug or lead

Mains power supply fault

Check mains power supply

The appliance

Too much ice on the evaporator

turns on, but the temperature is too

Condenser blocked with dust

high/low

Doors are not shut properly

Defrost the appliance Clean the condenser Check doors are shut and seals are not damaged

Appliance is located near a heat source or air flow to the condenser is being interrupted

Move the refrigerator to a more suitable location

Ambient temperature is too high Increase ventilation or move appliance to a cooler position

Unsuitable foodstuffs are being Remove any excessive hot foodstuffs or blockages

stored in the appliance

to the fan

Appliance is overloaded

Reduce the amount of food stored in the appliance

The appliance is The appliance is not properly

leaking water

levelled

Adjust the screw feet to level the appliance (if applicable)

The discharge outlet is blocked Clear the discharge outlet

The appliance is Movement of water to the drain Clear the floor of the appliance (if applicable)

leaking water

is obstructed

The water container is damaged Consult a qualified Technician

The appliance is unusually loud

Loose nut/screw
The appliance has not been installed in a level or stable position

Check and tighten all nuts and screws
Check installation position and change if necessary

The lamp does not illuminate

Lamp needing replacing

Consult a qualified Technician

7

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



EN

Telephone Helpline: 1300225960

Electrical Wiring

The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows: · Live wire (coloured brown) to terminal marked L · Neutral wire (coloured blue) to terminal marked N · Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Compliance

The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.
POLAR products have been approved to carry the following symbol:

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to change specifications without notice.

8 $%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD610-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Chilled: -2°C ~ 8°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 855 x 600 x 595mm

Kg 44kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD610-A 409 20.9 64L 64L N/A 0.035kg 100W/ 0.7A

CD610-A-02 361 18.4 64L 64L N/A 0.035kg 100W/ 0.7A

Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD080-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Chilled: -2°C ~ 8°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 855 x 600 x 595mm

Kg 44kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD080-A 409 20.9 64L 64L N/A 0.035kg 100W/ 0.7A

CD080-A-02 361 18.4 64L 64L N/A 0.035kg 100W/ 0.7A

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD611-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Frozen: -10°C ~ -25°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 855 x 600 x 595mm

Kg 44.5kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD611-A 511 18.0 78L N/A 78L 0.060kg 105W/ 0.8A

Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD081-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Frozen: -10°C ~ -25°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 855 x 600 x 595mm

Kg 44.5kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD081-A 511 18.0 78L N/A 78L 0.060kg 105W/ 0.8A

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD612-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Chilled: -2°C ~ 8°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1855 x 600 x 595mm

Kg 69kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD612-A CD612-A-02 CD612-A-03

478

489

460

47.8

48.7

45.9

238L

238L

238L

238L

238L

238L

N/A

N/A

N/A

0.075kg

0.075kg

0.075kg

130W/ 0.8A 130W/ 0.8A 130W/ 0.8A

Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD082-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Chilled: -2°C ~ 8°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1855 x 600 x 595mm

Kg 69kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD082-A 478 47.8 238L 238L N/A 0.075kg 130W/ 0.8A

CD082-A-02 CD082-A-03

489

460

48.7

45.9

238L

238L

238L

238L

N/A

N/A

0.075kg

0.075kg

130W/ 0.8A 130W/ 0.8A

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD613-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Frozen: -10°C ~ -25°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1855 x 600 x 595mm

Kg 71kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD613-A 894 32.6 258L N/A 258L 0.090kg 150W/ 0.9A

Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD083-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Frozen: -10°C ~ -25°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1855 x 600 x 595mm

Kg 71kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD083-A 894 32.6 258L N/A 258L 0.090kg 150W/ 0.9A

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD614-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Chilled: -2°C ~ 8°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1895 x 777 x 705mm

Kg 90kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD614-A CD614-A-02 CD614-A-03 CD614-A-04

N/A

672

697

577

N/A

51.8

53.1

43.9

419L

419L

419L

419L

419L

419L

419L

419L

N/A

N/A

N/A

N/A

0.100kg

0.100kg

0.100kg

0.100kg

130W/ 0.9A 130W/ 0.9A 130W/ 0.9A 130W/ 0.9A

Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD084-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Chilled: -2°C ~ 8°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1895 x 777 x 705mm

Kg 90kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD084-A N/A N/A 419L 419L N/A 0.100kg 130W/ 0.9A

CD084-A-02 CD084-A-03 CD084-A-04

672

697

577

51.8

53.1

43.9

419L

419L

419L

419L

419L

419L

N/A

N/A

N/A

0.100kg

0.100kg

0.100kg

130W/ 0.9A 130W/ 0.9A 130W/ 0.9A

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD615-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Frozen: -10°C ~ -25°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1890 x 777 x 705mm

Kg 94kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD615-A 989 26.1 469L N/A 469L 0.150kg 300W/ 1.4A

Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

CD085-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Frozen: -10°C ~ -25°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1890 x 777 x 705mm

Kg 94kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

EN Annual Energy Consumption AEC (kWh) EN Energy Efficiency Index EEI EN Net volume Vn litre (where applicable) EN Chilled volume Vn Ref litre EN Frozen volume Vn Frz litre EN Refrigerant charge x.xx kg EN Power / Current

CD085-A 989 26.1 469L N/A 469L 0.130kg 300W/ 1.4A

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



Information requirements for professional refrigerated storage cabinets
Note: Due to our continuous improvement process, the product specifications are subject to change without notice.

EN Model(s): [information identifying the model(s) to which the information relates]

GL185-A

EN Intended use

Storage

Category - Vertical/counter

Vertical

EN Operating temperature(s) - chilled/frozen/multi-use

Chilled: -2°C ~ 8°C

EN (where applicable) Heavy-duty/light-duty

Light Duty

EN Refrigerant fluid(s): [information to identify the refrigerant fluid(s), including GWP]

R600a/ GWP 3

V / Hz 220-240V~ 50Hz

H x W x D 1720 x 777 x 725mm

Kg 90kg

Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load limit) when filling.

GL185-A

EN Annual Energy Consumption AEC (kWh) 624

EN Energy Efficiency Index EEI

48.7

EN Net volume Vn litre (where applicable) 410L

EN Chilled volume Vn Ref litre

410L

EN Frozen volume Vn Frz litre

N/A

EN Refrigerant charge x.xx kg

0.095kg

EN Power / Current

130W/ 0.9A

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



DocuSign Envelope ID: 474B4AD6-8116-451F-8539-286AFDEC25C4

DECLARATION OF CONFORMITY

· Conformiteitsverklaring · Déclaration de conformité · Konformitätserklärung · Dichiarazione di conformità ·

· Declaración de conformidad

Equipment Type · Uitrustingstype · Type d'équipement · Gerätetyp

Model · Modèle · Modell · Modello

· Tipo di apparecchiatura · Tipo de equipo

· Modelo

C-Series Fridge
1. Stainless Steel Under Counter 150Ltr
2. Stainless Steel Upright 400Ltr 3. Stainless Steel Upright 600Ltr 4. White Under Counter 150Ltr 5. White Upright 400Ltr 6. White Upright 600Ltr

C-Series Freezer
7. Stainless Steel Under Counter 140Ltr
8. Stainless Steel Upright 365Ltr 9. Stainless Steel Upright 600Ltr 10. White Under Counter 140Ltr 11. White Upright 365Ltr 12. White Upright 600Ltr

C-Series Display
13. White Under Counter Fridge 150Ltr
14. White Upright Fridge 400Ltr 15. White Upright Fridge 600Ltr 16. White Upright Freezer 365Ltr

1. CD080 2. CD082 3. CD084 4. CD610 5. CD612 6. CD614

7. CD081 8. CD083 9. CD085 10. CD611 11. CD613 12. CD615 (including -
E & -A models)

13. CD086 14. CD087 15. CD088 16. CB921

Application of Territory Legislation & Council Directives(s) Toepassing van Europese Richtlijn(en) · Application de la/des directive(s) du Conseil · Anwendbare EU-Richtlinie(n) · Applicazione delle Direttive · Aplicación de la(s) directiva(s) del consejo

Machinery Directive 2006/42/EC Supply of Machinery (Safety) Regulations 2008 EN 60335-1:2012 +A11:2014 +A13:2017 +A1:2019 +A14:2019 +A2:2019 EN 60335-2-89:2010 +A1:2016 +A2:2017 EN62233:2008 Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU - recast of 2004/108/EC Electromagnetic Compatibility Regulations 2016 (S.I. 2016/1091) EN IEC 55014-1: 2021 EN IEC 55014-2: 2021 EN IEC 61000-3-2: 2019+A1:2021 EN 61000-3-3: 2013+A1:2019+A2: 2021 Regulation (EU) 2015/1095 - Ecodesign professional refrigerators EN 16825: 2016 +A1:2019 Regulation (EU) 2019/2024 - Ecodesign direct sales refrigerators ISO 23953-2:2015 Restriction of Hazardous Substances Directive (RoHS) 2015/863 amending Annex II to Directive 2011/65/EU Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (S.I. 2012/3032)

Electrical Safety IEC 60335.1:2010 +A1:2013 +A2:2016 IEC 60335-2-89:2010 +A1:2012 +A2:2015
Electromagnetic Compatibility EN IEC 55014-1: 2021 EN IEC 55014-2: 2021 EN IEC 61000-3-2: 2019+A1:2021 EN 61000-3-3: 2013+A1:2019+A2: 2021

Manufacturer Name · Naam fabrikant · Nom du fabricant · Name des Herstellers

Polar

· Nome del fabbricante · Nombre del fabricante

I, the undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s) and

Standard(s).

Ik, de ondergetekende, verklaar hierbij dat de hierboven gespecificeerde uitrusting goedgekeurd is volgens de bovenstaande Richtlijn(en) en

Standaard(en).

Je soussigné, confirme la conformité de l'équipement cité dans la présente à la / aux Directive(s) et Norme(s) ci-dessus

Ich, der/die Unterzeichnende, erkläre hiermit, dass das oben angegebene Gerät der/den oben angeführten Richtlinie(n) und Norm(en) entspricht.

Il sottoscritto dichiara che l'apparecchiatura di sopra specificata è conforme alle Direttive e agli Standard sopra riportati.

El abajo firmante declara por la presente que el equipo arriba especificado está en conformidad con la(s) directiva(s) y estándar(es) arriba

mencionadas.

18th Jun 2024

Date · Data · Date · Datum · Data ·

Fecha

Signature · Handtekening ·

Signature · Unterschrift Firma ·

Firma

Full Name · Volledige naam · Nom et prénom Ashley Hooper

Eoghan Donnellan

Brendan Denmeade

· Vollständiger Name · Nome completo ·

Nombre completo Position · Functie · Fonction · Position · Qualifica · Posición

Group Head of Product Quality & Compliance

Commercial Manager/ Importer

Commercial Manager/ Responsible Supplier

Manufacturer Address · Adres fabrikant · Adresse du fabricant · Adresse des Herstellers · Indirizzo del fabbricante · Dirección del fabricante

Fourth Way, Avonmouth, Bristol, BS11 8TB

Unit 9003, Blarney Business Park, Blarney, Co. Cork

15 Badgally Road, Campbelltown NSW 2560

United Kingdom

Ireland

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC



http://www.polar-refrigerator.com/ CD610-A to CD615-A_CD080-A to CD085-A_GL185-A_A5_v14_2024/11/04

$%"UP$%"@$%"UP$%"@(-"@"@W@JOEC





References

Adobe PDF Library 17.0 Adobe InDesign 19.5 (Macintosh)