
Installation Guide for Zip WATER models including: HydroTap G5 Boiling Chilled and Sparkling Water, HydroTap G5, Boiling Chilled and Sparkling Water, Chilled and Sparkling Water, Sparkling Water, Water
Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide 5 Ventilation installation instructions 4 Make sure there’s enough ventilation in the cupboard, air needs to circulate as follows: Cold air is drawn in through the gaps provided by the door buffers (supplied), they must be fitted.
File Info : application/pdf, 16 Pages, 6.83MB
DocumentDocumentQuick Reference Installation Guide Zip HydroTap G5 Command Centre - BCS HOME, BCS20, BCS20 H, BCS30, BCS30 H, BCS 60, BCS 60 H, BCS100, BCS100 H Follow these steps for a safe and effective install. 1 Read the safety information overleaf. This QRIG may be sufficient for installers who have had previous HydroTap installation experience. Inexperienced installers please scan the QR codes for detailed installation Installation videos instructions. ! Full installation instructions BCS Home BCS20, BCS20 H BCS30 , BCS30 H Full installation instructions BCS60, BCS60 H BCS100, BCS100 H 2 Contact us if you need support and advice. Zip Water Australia 67 - 77 Allingham Street, Condell Park NSW 2200 Postal: Locked Bag 80, Bankstown 1885 Australia, Tel (+612) 9796 3100, Free call 1800 947 827 (1800 ZIP TAP) Zip Water UK Trafalgar House, Rash's Green, Dereham, Norfolk, NR19 1JG United Kingdom, Tel 0345 6 005 005 Quick Reference Installation Guide 1 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Safety information This document is a Quick Reference Installation Guide. Download ! & read the full Command Centre installation instructions for more installation information. Explanation of symbols Read the instructions Danger of electric shock Compressed Gas WARNING ! WARNING Highly flammable HOT Surface Lithium Coin cell · Compliance : In Australia electrical installation must comply with AS/NZS3000. · In Australia plumbing installation must comply with AS/NZS3500. · In Australia For residential chilled models, all refrigeration must comply with AS/NZS 60335.2.24. In the UK the system must be installed in accordance with water supply by-laws, current IEEE regulations and local authority by-laws. · This appliance is not intended for use by children under 8 years or persons (including children under 8 years) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. · The Zip HydroTap Command Centre range uses HIGHLY FLAMMABLE R290 refrigerant under pressure. · Check the rating plate or contact Zip before commencing work. · To avoid hazards, all installation procedures must be carried out by a suitably qualified tradesperson. Maintenance of the refrigeration unit specifically must be carried out by an accredited service provider or qualified refrigeration technician. Faulty operation due to unqualified persons working on this product may void warranty coverage. · Warning! Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction. · Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. · Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance. CO2 · Keep out of reach of children. · Use according to MSDS (material safety data sheet). · Pressurised container. Contains gas under pressure,may explode if heated. · Protect from sunlight. · Do not expose to temperatures exceeding 50°C. · Do not expose to naked flame or any incandescent material. · Do not pierce or burn, even after use. Avoid shock. 2 Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Safety information · High concentration of gas may cause asphyxiation. · Use only in an upright position. · The cylinder must be used with the supplied pressure regulator. · The gas cylinder must be installed in an open plan area, or in an enclosed room with a volume no less than 20m³ per 1200g cylinder, or 50m³ per 2640g cylinder. If more than 1 gas cylinder containing CO2 is present within the same location, the recommended ventilated area should be in proportion to the number of gas cylinders stored in that location. A ventilated area is a non-enclosed area which could include the kitchen, living room etc. · The HydroTap G5 Home series is intended to be used in household and similar applications such as: · Staff kitchen areas in shops, offices and other working environments; · Farm houses and by clients in hotels, motels and other residential type environments; · Bed and breakfast type environments; · Catering and similar non-retail applications. · For continued safety of this appliance it must be installed, operated and maintained in accordance with the manufacturer's instructions. · This appliance may deliver water at high temperature. Refer to the Plumbing Code of Australia (PCA), local requirements and installation instructions to determine if additional delivery temperature control is required. · The button/coin battery is hazardous and is to be kept away from children. It can cause severe or fatal injuries in 2 hours or less if it is swallowed or placed inside any part of the body. Medical attention should be sought immediately if it is suspected the battery has been swallowed or placed inside any part of the body. · The Zip HydroTap must be earthed. Earthing is provided via the supplied power cord. The resistance of the earth connection to each exposed metal part must be less than 1. Use the power cable supplied. Power point earthing is the responsibility of the installer. · Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply. · Connect only to a potable (wholesome, cat1) mains water supply. · The new hose sets supplied with the product must be used. Do not re-use old hose sets. · Never locate the system near, or clean with water jets. · The integrated vent provides a safe exhaust for the refrigerant gas in the event of a leak. · The power cord and general power outlet must be in a safe and accessible position after installation. When positioning the appliance, ensure the power supply cord is not trapped or damaged. If the power supply cord is damaged it must be replaced by a Zip service provider or a qualified electrician. · Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance. Quick Reference Installation Guide 3 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Installation - Technical data, part supplied 3 Review the technical data & parts supplied in the kit. Model BCS100,BCS100 H BCS60,BCS60 H BCS30,BCS30 H BCS20,BCS20 H BCS Home Power rating, kW 220-240V, 50Hz 2.15 + Booster 2.15 1.96 + Booster 1.96 1.53 Dimensions W x D x H (mm) 395 x 487 x 333 395 x 487 x 333 339 x 483 x 333 339 x 483 x 333 339 x 483 x 333 Water supply Connection G 1/2 G 1/2 G 1/2 G 1/2 G 1/2 Weight (kg) 41 41 34 34 34 Component Sparkling HydroTap Vented Mixer Tap Booster & Limescale filter Min - Max pressure, kPA (bar) Australia UK 250 (2.5 ) - 700 (7.0) 250 (2.5) - 500 (5.0) 300 (3.0) - 700 (7.0) 200 (2.0) - 500 (5.0) 200 (2.0) - 700 (7.0) 200 (2.0) - 500 (5.0) Booster electrical rating 230V 50/60Hz - 2.20kW 240V 50/60Hz - 2.40kW Parts supplied with the Command Centre Command Centre, instructions, power cable, supply hose, door buffers. Vent kit inc. 2 Exhaust vent mounting plates,(use either, depending on cupboard overhang) Water supply inlet adaptor and strainer. Install rail kit (inc isolation valve), & instructions. (UK only) CO2 cylinder & regulator, & hose. Booster & hoses. Optional Limescale filter kit. Optional 4 Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Ventilation installation instructions 4 Make sure there's enough ventilation in the cupboard, air needs to circulate as follows: Cold air is drawn in through the gaps provided by the door buffers (supplied), they must be fitted. Command Centre clearances must be observed. Warm air is expelled through the integrated vent in the base of the Command Centre, via the vent cut-out in the cupboard floor. A vent mounting plate a or b (supplied) covers the cut out. If installing in a cupboard with less than 40mm overhang, use vent d too. Ventilation Installation Instructions If installing in a warm space, use optional extra, inlet vent c . The inlet vent cut-out may be positioned in the cupboard side, door or floor (depending on cupboard size and overhang). Observe 100mm inlet / outlet vent separation. To install the mounting plate & optional extra inlet vent grilles, scan the QR Codes , follow the instructions: ! Incorrect ventilation installation may void warranty coverage. Ventilation Installation Video ! The door buffers (supplied) must be fitted to the cupboard, for each door, in all installations, to maintain effective airflow. See below: Top door buffers Bottom door buffers Quick Reference Installation Guide 5 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Ventilation installation instructions 5 BCS Home, BCS20, BCS20 H, BCS30, BCS30 H ventilation options Option 1: Ventilation arrangement using small cupboard with min. 40mm overhang Directing warm air straight into the room. a Must be installed 2C0le0amramnce a Must be installed 5Cb0leemsaimdraeInnmicnlieenlett 40mm min. overhang Option 2: Ventilation arrangement using small cupboard with less than 40mm, or no overhang. Directing warm air into the kick space & out through a vent grille. b d Must be installed 2C0le0amramnce Both must be installed b d 6 Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Inlet 5Cb0leemsaimdraenmicnienlet Loevsesrthhaanng40mm or no Ventilation installation instructions 6 BCS60, BCS60 H, BCS100, BCS100 H ventilation options Option 3: Ventilation arrangement using large cupboard with min. 40mm overhang Directing warm air straight into the room. a Must be installed 2C0le0amramnce Inlet 5cb0leemsairmdaenmicneinle.t 40mm min overhang 100mmmin a Must be installed c Extra Inlet vent option Option 4: Ventilation arrangement using small cupboard with min. 40mm overhang Directing warm air straight into the room. a Must be installed Inlet 2C0le0amramnce Extra Inlet vent option c 50cmlemabreamsinniidcnleee.t 40mm min overhang 10m0minm a Must be installed Quick Reference Installation Guide 7 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Ventilation installation instructions Option 5: Ventilation arrangement if using a large cupboard with less than 40mm, or no overhang. Directing warm air into the kick space & out through a vent grille. b d Must be installed 2C0le0amramnce Inlet Extra Inlet vent option 5cb0leemsairmdaenmicneinle.t Both must be installed b d c Loersnsothoavnerha4n0gmm 100mm min Option 6: Ventilation arrangement if using small cupboard with less than 40mm, or no overhang. Directing warm air into the kick space & out through a vent grille. b d Must be installed 2C0le0amramnce Inlet Extra Inlet vent option c 50cmlemabreamsinniidcnleee.t Both must be installed b d Loersnsothoavnerha4n0gmm 10m0minm 8 Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Installation - Ancillary components, Booster 7 If supplied as part of the kit mount the Booster as follows: 10 a bc 15 f d e Connect the braided hoses to the Booster: ! Do not over tighten hose connections. Braided hoses supplied cannot be lengthened. 3/8" BSP Cold water into Booster, connect to Command Centre BYPASS OUT Strainer connections Hot water out of Booster, connect to Command Centre BYPASS IN Booster Hold connections with spanner while tightening hoses Mount horizontally Mount horizontally Installation - Ancillary components, Limescale filter 8 UK only If installing a limescale filter, set the bypass valve (Rear of the Command Centre). Scan the QR Codes & read the filter instructions 95603 95601, 95602 Bypass valve Quick Reference Installation Guide 9 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Installation - Ancillary components, Carbonation valve 9 When fitting the carbonation valve, observe the following guidelines : Celsius AiO Arc Classic, Wave Classic Plus, Elite Other sparkling Avoid + - Adjust the carbonation valve during commissioning, see sections 12 14 Use an Allen key or screwdriver to adjust the carbonation flow. Anti-clockwise to increase, Clockwise to decrease. To measure flow rate: Use a measuring jug, run the sparkling water for 15 seconds. Multiply the amount of water dispensed in 15 seconds by 4 to determine the flow rate in litres per minute. The optimum flow rate is 1.6 litres per minute (400ml per 15 seconds). If the flow rate is too high, the carbonation tank will be emptied of water, leaving only CO2 to be dispensed from the tap. This will result in inconsistent flow (spluttering). General installation arrangement instructions 10 Make sure the braided hose and adaptor arrangement for the mains water supply are installed as follows: Mains cold water supply 90º bend Inline Inline filter filter adaptor 10 Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Command Centre BCS Home, BCS20, BCS20 H, BCS30, BCS30 H Installation 11 Install the HydroTap in order a to h . Install the vent mounting plate a on the cupboard floor, scan the QR Code & read the instructions. Scan the QR Code & read the instructions ! For UK, fit the install rail (scan the QR for instructions). Establish the water supply (install inlet adaptor & hose). e b Install the Command Centre Ventilation Installation Install Rail c Instructions UK only Fit the tap connections: RED silicone - Boiling Out Clear silicone - Vent Blue JG - Chilled Out White JG - Sparkling Out USB f Fit the Booster & hoses (if supplied in the kit). d Fit carbonation valve & insulation. ! DO NOT SWITCH ON Booster until Commissioning. Note For mixer tap configuration, see full instruction manual . g Install CO cylinder 2 regulator and hose. Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide h Connect to the power supply DO NOT SWITCH ON ! Command Centre until Commissioning. 11 BCS Home, BCS20, BCS20 H, BCS30, BCS30 H Commissioning 12 Commission the HydroTap in order i to n . l Commissioning process, follow screen prompts, scan HydroTap Clean QR for more information. m If cupboard temperatures exceed 35OC additional ventilation will be required. HydroTap Clean n To use the HydroTap, scan the User Guide QR Code & read the instructions. Turn on water supply & check for leaks. i User Guide j Turn on CO 2 & check for leaks. 12 Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide k Turn on the power supply. BCS60, BCS60 H, BCS100, BCS100 H Installation 13 Install the HydroTap in order a to h . Install the vent mounting plate a on the cupboard floor, scan the QR Code & read the instructions. Scan the QR Code & read the instructions ! Ventilation Installation Install Rail Fit the tap connections: RED silicone - Boiling Out Clear silicone - Vent c Blue JG - Chilled Out White JG - Sparkling Out USB Instructions UK only For UK, fit the install rail (scan the QR for instructions). Establish the water e supply (install inlet adaptor & hose). Fit carbonation valve & d ! insulation. DO NOT SWITCH ON Booster or Command Centre until Commissioning. f Fit the Booster & hoses (if supplied in the kit). h Connect to the power supply. b Install the Command Centre g *Install CO cylinder 2 regulator and hose. Notes For mixer tap configuration,see full instruction manual. *For UK use 1.2kg cylinder & non adjustable regulator. Quick Reference Installation Guide 13 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide BCS60, BCS60 H, BCS100, BCS100 H Commissioning 14 Commission the HydroTap in order i to n . l Commissioning process, follow screen prompts, scan HydroTap Clean QR for more information. m If cupboard temperatures exceed 35OC additional ventilation will be required. HydroTap Clean n To use the HydroTap, scan the User Guide QR Code & read the instructions. User Guide Turn on water supply & check for leaks. i k Turn on the power supply. j Turn on CO 2 & check for leaks. Adjust regulator to 300kPa. 14 Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Notes Quick Reference Installation Guide 15 810008 v1.00 08.24 G5 BSC Quick Reference Installation Guide Refer to User Guide for operation and maintenance. As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods. The terms "Zip" and "HydroTap" are registered trade marks of Zip Heaters (Aust) Pty Ltd. 16 Quick Reference Installation Guide 810008 v1.00 08.24 G5 BSC Quick Reference Installation GuideAdobe PDF Library 17.0 Adobe InDesign 19.1 (Windows)