User Guide for ADDAC System models including: ADDAC310 Pressure To CV Module, ADDAC310, Pressure To CV Module, CV Module, Module

ADDAC310 Pressure2cv B 1

ADDAC310 Pressure to CV User's Guide

ADDAC310 - ADDAC300 Series - Modules - Products - ADDAC System | Instruments for Sonic Expression

PDF preview unavailable. Download the PDF instead.

ADDAC310 Pressure2cv B 1
Instruments for Sonic Expression
Est.2009
INTRODUCING
ADDAC310 PRESSURE TO CV
USER'S GUIDE . REV01
June.2024
From Portugal with Love!

Welcome to:
ADDAC310
PRESSURE TO CV USER'S GUIDE
Revision.01 June.2024

WELCOME
This module expands our line of expressive controls, it follows the heritage of wind/breath controllers with one major diference, the pipe has no air escape creating pressure inside the tube controlled by the user's mouth. For a seasoned woodwind or brass musicians this working principle may sound unorthodox, however this way pressure can be controlled for longer without the need to breath in or learning circular breathing techniques. It's relatively easy to control the pressure in your mouth while still breathing through the nose. The module is provided with a standard melodica pipe which connects to an air filter (providing a receptacle for condensation to form and isolate the sensor) and lastly connects to the module frontpanel.
The signal captured by the sensor is then sent to two independent sections with exactly the same functions as seen in the signal flow diagram below.
As an example the two sections can be used with diferent settings to independently control the VCA and VCF of any standard analog voice patch.
PIPE INPUT

CHANNEL A

GAIN

RESPONSE CURVE ENVELOPE PROCESSING
ATTACK DECAY

OFFSET
GATE FOLLOW MODES ROUTING
GATE HOLD MODES ROUTING

GAIN OFFSET HOLD

THRESHOLD

GATE A OUTPUT CV OUTPUT
INVERTED CV OUTPUT

INVERTER

RESPONSE CURVE ENVELOPE PROCESSING
ATTACK DECAY

GAIN

GAIN OFFSET HOLD

OFFSET
GATE FOLLOW MODE ROUTING
GATE HOLD MODES ROUTING

THRESHOLD

INVERTER

GATE A OUTPUT CV OUTPUT INVERTED CV OUTPUT

Tech Specs: 10HP 4.5cm deep 70mA +12V 40mA -12V

ADDAC SYSTEM

CHANNEL B
page 2

ADDAC310 User's Guide
CONTROLS DESCRIPTION
[CV OUTPUT LEDS] Two leds for each channel monitors the bipolar CV Output. [HOLD PUSH BUTTON] Latch button turns the hold function On or Off. [ATTACK] & [DECAY] Sets the Attack & Decay that will slew the sensor raw value.
[GAIN] Sets the channel CV gain. [OFFSET] Sets the channel CV offset.
[RESPONSE] Sets the sensor calibration response curve.
[GATE THRESHOLD] Sets the threshold for the gate output.
[PIPE INPUT] The sensor input to connect the external pipe.
[GATE STATE LED] Monitors the Gate Output state. [HOLD GATE INPUT] Gate input for the Hold function. [GATE OUTPUT] [INVERTED CV OUTPUT] [CV OUTPUT]

PIPE We're using a standard Melodica pipe into an air filter that will keep condensation away from the sensor. The air filter is then connected to the frontpanel sensor input using a silicone tube.

SENSOR CALIBRATION [RESPONSE] is the main control to calibrate the pressure

RESPONSE: EXP

LIN

LOG

curve, the knob goes from exponential to logarithmic with

linear at 12 o'clock. Exponential will be more reactive to high

pressures, logarithmic to lower pressures.

ADDAC SYSTEM

page 3

ADDAC310 User's Guide
CONTROLS DESCRIPTION

ATTACK & DECAY The [ATTACK] & [DECAY] controls will slew the incoming raw sensor value

ATTACK & DECAY: SENSOR RAW

POST ATTACK DEACY

GAIN & OFFSET The [GAIN] & [OFFSET] controls allow to map the output voltages to the precise range needed.

GAIN & OFFSET:
+5v

CV OUTPUT INVERTED CV OUTPUT

0v

-5v +5v

0v

-5v +5v

0v

-5v

GATE TRESHOLD & GATE OUTPUT The Gate output will be ON when the voltage output is above the [THRESHOLD] control knob setting.

GATE OUT:
+5v

CV OUTPUT GATE OUTPUT

Threshold
0v

ADDAC SYSTEM

page 4

ADDAC310 User's Guide
HOLD FUNCTION

HOLD FUNCTION This feature allows to hold the current voltage value with the hold is engaged (button led on), the state can be changed either by the push button or the trigger input in a latching manner (push or gate on to change state).

HOLD ON/OFF: HOLD ON VIRTUAL OUTPUT

CV OUTPUT

GATE OUTPUT HOLD MODES There are 2 modes for the behaviour of the [GATE OUTPUT] while the [HOLD] function is on. To change between modes just keep the [HOLD] button pressed for a second, after releasing the button the button led will blink once for Mode A and twice for Mode B.
Mode A (default): [GATE OUTPUT] follows the virtual output Mode B: [GATE OUTPUT] follows the [CV OUTPUT]
HOLD ON/OFF: HOLD ON VIRTUAL OUTPUT CV OUT GATE OUT

Threshold Mode A Mode B
GATE OUTPUT FOLLOW MODES There are 2 modes for the behaviour of the [GATE OUTPUT] depending what the Gate is following. To change between modes quickly press twice the channel button you want to change. The button led will blink once for Mode A and twice for Mode B.
Mode A (default): [GATE OUTPUT] follows the module [CV OUTPUT] Mode B: [GATE OUTPUT] follows the sensor value before the Attack and Decay slew is applied.
VIRTUAL SENSOR VALUE CV OUT GATE OUT
Threshold
Mode A Mode B
ADDAC SYSTEM

Both Modes are saved in internal memory and will be recalled at startup.
page 5

For feedback, comments or problems please contact us at: addac@addacsystem.com
ADDAC310 USER'S GUIDE
Revision.01 June.2024


Adobe PDF library 15.00 Adobe Illustrator 24.2 (Macintosh)