MGL MS2125A AC/DC Clamp Meter
Quick Start Guide
Safety Precautions
Special attention should be paid when using the test and measurement instrument as improper usage may cause electric shock and damage the equipment.
- Use proper measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.
- Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
- When handling the test probes and crocodile clips, keep your fingers behind the physical guard.
- Examine the measuring test leads (if present) before use. Replace any element with deteriorated insulation with proper functional test leads.
- Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
- Before measuring current, ensure the instrument fuses are available and disconnect the power supply to the circuit being tested.
- Remove batteries if the device is not used for an extended period or stored in temperatures above 45 °C to prevent battery leakage damage.
Specifications
| Range | Resolution | Accuracy |
|---|---|---|
| V~ (60mV to 600V) | 0.01mV to 0.1V | ±(0.6%+5) to ±(0.8%+4) |
| V~ (750V) | 1V | ±(0.8%+4) |
| V (60mV to 600V) | 0.01mV to 0.1V | ±(0.5%+5) to ±(0.8%+4) |
| V (1000V) | 1V | ±(0.8%+4) |
| A~ (60A to 1000A) | 0.01A to 1A | ±(2.0%+8) |
| A (60A to 1000A) | 0.01A to 1A | ±(2.0%+8) |
| R (600Ω to 60MΩ) | 0.1Ω to 0.01MΩ | ±(0.8%+3) to ±(2.0%+5) |
| C (10nF to 100mF) | 0.001nF to 0.01mF | ±(3.0%+5) |
| Hz (100Hz to 1000Hz) | 0.01Hz to 0.1Hz | ±(1.5%+5) |
| Hz% (0.1% to 99.9%) | 0.1% | ±(3.0%) |
Measurement Guide
Voltage Measurement (AC/DC):
- Connect the red test lead to the INPUT jack and the black test lead to the COM jack.
- Turn the dial to the desired AC (V~) or DC (V) voltage setting.
- Press the FUNC button to select between AC and DC if applicable.
- Connect the test leads across the component or circuit to be measured.
- Read the voltage displayed on the screen.
Current Measurement (AC/DC):
- Open the clamp jaw and place it around the conductor.
- Turn the dial to the desired AC (A~) or DC (A) current setting.
- Press the FUNC button to select between AC and DC if applicable.
- Read the current displayed on the screen.
Resistance Measurement (Ω):
- Connect the red test lead to the INPUT jack and the black test lead to the COM jack.
- Turn the dial to the resistance (Ω) setting.
- Press the FUNC button to select the appropriate range if needed.
- Connect the test leads across the component to be measured.
- Read the resistance displayed on the screen.
Capacitance Measurement (F):
- Connect the red test lead to the INPUT jack and the black test lead to the COM jack.
- Turn the dial to the capacitance (F) setting.
- Press the FUNC button to select the appropriate range if needed.
- Connect the test leads across the capacitor to be measured.
- Read the capacitance displayed on the screen.
Frequency Measurement (Hz):
- Connect the red test lead to the INPUT jack and the black test lead to the COM jack.
- Turn the dial to the frequency (Hz) setting.
- Connect the test leads to the signal source.
- Read the frequency displayed on the screen.
Non-Contact Voltage (NCV) Detection:
- Turn the dial to the NCV setting.
- Bring the sensor near a conductor or outlet.
- The device will emit a beep and/or a visual indicator if voltage is detected.
Warranty Information
CAT IV 600V, CAT III 1000V
1 YEAR LIMITED WARRANTY