Trade Essentials Aluminium Designer White

Fitting Instructions

Aluminium Radiator in White Horizontal and Vertical

Please read these instructions and terms and conditions carefully prior to installation. Failure to do so may invalidate the warranty.

Drawings

Drawing 1 - Bush Configurations

Description: Diagram showing two types of bushes, labeled 'S' and 'D'. The 'S' bushes are tightened anti-clockwise, and the 'D' bushes are tightened clockwise. The text explains that 'S' bushes are on the left when looking at the radiator front, and 'D' bushes are on the right. It advises using up to 4 turns of PTFE tape for sealing threads, applied in the direction of the thread, to prevent leaks.

Important Note: Trade Essentials Aluminium Designer White radiators have specific left and right-hand threaded bushes that can be easily damaged if forced or fitted incorrectly, which will inevitably cause leaks. Bushes require a dry fit connection only; do not use any compound materials (e.g., Jet Blue) or Plumbers Hemp. If you choose, you may use up to 4 turns of PTFE tape to help seal the threads (the tape should be applied in the direction of the thread and no more than this amount should be used as this may cause leaks to occur).

Drawing 2 - Bracket Positions

Description: Diagram illustrating the placement of wall brackets. It shows two left-hand brackets and two right-hand brackets. The text indicates that brackets should be fixed using a suitable drill bit, screws, and plugs, ensuring they are level and square prior to hanging the radiator for vertical alignment with pipework. It advises marking and fixing the two top brackets first, ensuring they are level, then hanging the radiator and marking the location of the two bottom brackets before fixing them.

Pipe Centres

1. Unpack & Inspect

This product should have reached you in perfect condition. Please carefully unpack and inspect this radiator and all fittings. Your point of purchase must be notified of any shortages or damage within 28 days of delivery. For further information, please see terms and conditions on reverse.

2. Contents

You should have:

You will need:

3. Fit Diverter

Aluminium radiators which are 1400mm tall are supplied with a Spring Diverter, which is installed in the lower waterway at either end. This is installed by pushing the cap firmly into the waterway until it locates against the barrel nipple and is retained in place by the bush. The flow must enter this end first.

4. Fix Brackets

You will have been supplied with at least four brackets. The brackets are typically positioned one section in from either end, with extra brackets spaced at equal distances between these. Brackets should be fixed using a suitable drill bit, screws, and plugs. It is essential that all brackets are level and square prior to hanging the radiator to ensure a vertical alignment for connecting the pipework. Mark and fix the two top brackets, checking they are level. Hang the radiator in position and mark the location of the two bottom brackets and fix in place.

5. Hang & Commission Radiator

With the brackets firmly fixed and level, the radiator is lowered directly onto the brackets. When commissioning your radiator on an indirect/closed system, it is recommended to use a suitable quality and quantity of mixed metal inhibitor to protect against scale and corrosion. Damage caused to systems not protected by a suitable inhibitor will not be covered by the manufacturer's guarantee.

Technical Specifications

Materials Aluminium.
Connections 1/2" flow and return.
Test pressure 9 Bar
Testing authority EN442
Maximum operating pressure 6 Bar
Maximum working temperature 110°C
Packaging Wrapped in polythene & boxed.

PLEASE NOTE: To reduce the possibility of noise caused by rapid heating and cooling of aluminium radiators, adequate capacity for expansion must be provided within the overall heating system. Systems using micro bore pipework must have adequate pressure and flow rates for the number and style of radiators on the system.

Guarantees & Liabilities

This product is guaranteed for 10 years. As Radiators 4u are not the manufacturers of this product, they will take all reasonable endeavours to pass over the benefit of any warranty or guarantee given by the manufacturer. The guarantees in all cases are subject to the products being installed in accordance with British and/or European standards as well as these fitting instructions. The guarantees in all cases are restricted to the free of charge replacement or repair of the failed product only. Radiators 4u's liability will under no circumstances extend beyond the repair or replacement of the product supplied by them. Claims for either labour in replacement or damage to property are not admissible. Any goods that are returned, in the event of a problem, will belong to Radiators 4u.

Terms & Conditions

All products must be inspected once removed from the packaging, and your point of purchase notified of any scratches, blemishes, or other damage within 28 days of delivery. Your point of purchase will then agree appropriate action. Imperfect radiators should therefore not be fitted, and Radiators 4u will not accept responsibility for replacement of scratched or damaged radiators once they have been fitted. This includes any consequential loss or cost of fitting. If Radiators 4u are not notified within 28 days of the date on the signed delivery note, then it will be deemed that they have fully complied with their obligations, and claims will not be considered. Failure to comply with any of the above may invalidate any claims. Radiators 4u recommend that after you check the product on delivery, it is stored in its packaging to prevent damage prior to installation; Radiators 4u cannot accept responsibility for items damaged after delivery. For full details of Radiators 4u's Terms and Conditions, please visit www.radiators4u.co.uk or call 02394 216 216.