User Guide for ADI Icron models including: 3204C Pro, 3204C Pro 4-Port USB 3 5Gbps 10GbE LAN USB-C Extender System, 4-Port USB 3 5Gbps 10GbE LAN USB-C Extender System, USB 3 5Gbps 10GbE LAN USB-C Extender System, 5Gbps 10GbE LAN USB-C Extender System, 10GbE LAN USB-C Extender System, USB-C Extender System, Extender System, System
4-port USB 3 (5Gbps), 10GbE LAN or CAT 6a/7 USB-C extender
Raven 3204C Pro
File Info : application/pdf, 2 Pages, 342.98KB
DocumentDocumentQuick Start Guide USB 3-2-1 RavenTM 3204C Pro 4-Port USB 3 (5Gbps), 10GbE LAN or CAT 6a/7 USB-C Extender System Package Contents: USB 3-2-1 Raven 3204C Pro LEX USB 3-2-1 Raven 3204C Pro REX USB-C Cable 24V 1A AC Adapter 24V 2.71A AC Adapter 2x Country Specific Power Cords Quick Start Guide For more information about configuring and operating this product, refer to the complete online user guide at icron.com/3204Cpro. For technical support, visit icron.com/support. For sales/general inquiries, visit icron.com/contact. Before starting, install any required drivers for your USB device(s). LEX = Local Extender REX = Remote Extender Network Connect Place LEX and REX where desired and Link in one of two ways: Direct Connect 1 (a) Connect the Link ports (outermost RJ45 connector) on the (b) Connect a CAT 6a/7 cable to the Link ports (outermost RJ45 LEX and REX to a 10GBASE-T LAN using a CAT 6a/7 cable. connector) on the LEX and REX. LEX Back View REX LEX REX or Link Link Link Link Network Switch Max 100m between extender and network switch. Max 100m CAT 6a/7 Cable (not included) 2 Power the LEX with the included 24V 1A AC adapter and tighten the locking ring. 3 Power the REX with the included 24V 2.71A AC adapter and tighten the locking ring. LEX REX 24V 1A Note: If an outlet is unavailable, refer to the online user guide for an alternate LEX powering option. 24V 1A AC Adapter 24V 2.71A 24V 2.71A AC Adapter 4 Connect the LEX to the host computer's USB-C port using the included USB-C cable. Host LEX Host USB-C Cable 5 Attach the USB device(s) to the REX. REX USB USB USB-C USB-C 6 Optional: Connect the LEX and REX 1Gb Ethernet ports (inner RJ45 connector) to a network or device as necessary for pass-through LAN. 1Gb Ethernet USB Devices Max 100m (CAT cable not included) Certification, Compliance, and Warranty Information FCC Radio Frequency Interference Statement Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. CE Statement We, Icron, an Analog Devices brand, declare under our sole responsibility that the USB 3-2-1 RavenTM 3204C Pro, to which this declaration relates, is in conformity with European Standards EN 55032, EN 55035, EN 61000, EN 62368-1 and RoHS Directive 2011/65/EU + 2015/863/EU. Hardware Remedies Icron's entire liability and the Licensee's exclusive remedy for any breach of warranty, shall be, at Icron's option, either: (a) return of the price paid, or (b) repair or replacement of hardware, which will be warranted for the remainder of the original warranty period or 30 days, whichever is longer. These remedies are void if failure of the hardware has resulted from accident, abuse, or misapplication. Limitation of Liability The hardware warranty set forth in this agreement replaces all other warranties. Icron expressly disclaims all other merchantability and fitness for a particular purpose and non-infringement of third-party rights with respect to the hardware. Industry Canada Statement This Class B digital apparatus complies with Canadian ICES-003. CAN ICES-3 (B) / NMB-3 (B) WEEE Statement The European Union has established regulations for the collection and recycling of all waste electrical and electronic equipment (WEEE). Implementation of WEEE regulations may vary slightly by individual EU member states. Please check with your local and state government guidelines for safe disposal and recycling or contact your national WEEE recycling agency for more information. Product Operation and Storage Please read and follow all instructions provided with this product and operate for intended use only. Do not attempt to open the product casing as this may cause damage and will void the warranty. Use only the power supplies provided with this product. When not in use, this product should be stored in a dry location between -20°C and 70°C. Product user guides are available online at icron.com. Limited Hardware Warranty Icron warrants that any hardware products accompanying this documentation shall be free from significant defects in material and workmanship for a period of two years from the date of purchase. Icron's hardware warranty extends to Licensee, its customers and end users. The warranty does not include repair of failures caused by misuse, neglect, accident, modification, operation outside a normal operating environment, service of the device by non-authorized servicers or a product for which Icron is not responsible. Icron dealer, agent or employee is not authorized to make any modification, extension, or addition to this warranty. Under no circumstances will Icron, its suppliers or licensors be liable for any costs of procurement or substitute products or services, lost profits, loss of information or data, or any other special, indirect, consequential, or incidental damages arising in any way out of the sale of, use of, or inability to use Icron product or service, even if Icron, its suppliers or licensors have been advised of the possibility of such damages. In no case shall Icron, its suppliers and licensors' liability exceed the actual money paid for the products at issue. Since some jurisdictions do not allow the limitation of implied warranties of liability for incidental, consequential, special, or indirect damages, the above limitation may not always apply. The above limitations will not apply in case of personal injury where and to the extent that applicable law requires such liability. Obtaining Warranty Service Contact the Icron technical support team within the warranty period to obtain a Return Material Authorization (RMA) number. To begin the warranty process, please fill out the short online form located at icron.com/support. Icron | An Analog Devices Brand 4664 Lougheed Hwy., Suite 221 Burnaby, BC V5C 5T5 Canada t +1 604.638.3920 Visit icron.com Copyright © 2023 Analog Devices, Inc. All Rights Reserved. Trademarks and registered trademarks are the property of their respective holders. ADI/Icron assumes no responsibility for errors that may appear in this document. Information contained herein is subject to change without notice. 90-01933-A02