Owner's Manual for POTTER models including: PFC-6075 75 Point Addressable Fire Alarm Control Panel, PFC-6075, 75 Point Addressable Fire Alarm Control Panel, Fire Alarm Control Panel, Control Panel
Potter PFC-6075 75 Point Addressable Fire Alarm Control Panel - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 3 Pages, 1.43MB
DocumentDocumentS735 7165-0328:0195 NYC Fire Dept. Certificate of Approval 6157 Product includes a 5 year warranty PFC-6075 FIRE ALARM CONTROL PANEL Features · 75 Analog/Addressable Points in Any Combination · 5 Amp Power Supply · 4 NACS, 2 Regulated, Rated at 3 Amps each & 2 Input/Output (I/O) Circuits rated at 1 Amp each · Strobe Synchronization and System Wide Sync for Potter/ AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes · 99 Software Zones · Large LCD and Keypad for Ease of Operation · Cabinet with enclosure rather than cabinet will house 8 or 18 AH batteries. Dead Front Cabinet for Clean Look. · Smoke Detector Drift Compensation and Maintenance Alerts · NFPA 72 Compliant Smoke Sensitivity Test Built-In · System wide Class A or Class B · 1,000 Event History Buffer · Optional two line DACT (UD-1000) · P-Link Communication Line for Annunciators and Accessories · Ethernet Port for Programming and Network Connectivity · E-Mail System Status, Reports, and Event Information · Integrated, Listed IP Communicator · Size (W x H x D): 16" x 17" x 3 7/8" Electrical Specs: AC Mains Battery: · 3.0 Amps @ 120 VAC 50/60 H2 · 130 mA Standby · 2.0 Amps @ 240 VAC 50/60 H2 · 220mA Alarm Description The PFC-6075 is a versatile seventy-five (75) point analog/addressable fire alarm control panel that utilizes the Potter/Nohmi device protocol that has a complete line of initiating and control devices. The SLC is capable of 50 ohms of resistance and does not require the use of twisted or shielded wire. The signaling line circuit may be any combination of smoke sensors, heat detectors or modules. The PFC-6075 has a metal cabinet with a key lock and a dead front standard. The cabinet will house 8 Ah or 18 Ah batteries. The large viewing window allows easy viewing of the LCD and the standard LEDs. The keypad allows easy operation and navigation of the system menu. The panel has a 5 amp power supply with two (2) notification circuits each rated at 3 amps and two (2) Input/Output (I/O) circuits each rated at 1 amp. All of the outputs are power limited, power regulated and may be programmed for Potter/AMSECO, Gentex®, CooperWheelock® and System Sensor® strobe synchronization. The outputs may be configured for any combination of strobe brands and all will sync. The outputs also may be configured for door holder power, auxiliary power and constant power. The panel has auto-programming learn mode that will not affect the existing system when adding or deleting a device. The system is capable of 99 software zones, cross zoning and counting zones. The panel is fully programmed from a PC based software program that will work with Microsoft XP, Vista or Windows 7.0 operating systems. The PFC-6075 has an Ethernet connection for programming network connectivity and IP reporting communicator. The system uses a simple patch cable for connecting a PC to the panel. In addition, the system may be connected to a building network and programmed while on the network. The system has a built in e-mail function and will send system E-mail reminders. The IP communicator is listed with the Sur-Gard III IP receiver. The panel will support P-Link devices which include: the RA-6075, RA-6500 and LED-16 Annunciators, RLY 5 Relay Module, SPG-1000 Serial Parallel Gateway (printer card), FCB-1000 Remote Ethernet/IP connection (only 1), DRV-50 LED driver for 50 LEDs, PSN-1000 Remote Power Supplies (10 Amp) and FIB-1000 P-Link Fiber Interface Module. In addition, the panel allows for the installation of the UD-1000 dual line telephone line digital alarm communicator transmitter (DACT). The UD-1000 is programmable for a single line or dual line and is compatible with Ademco's Contact ID or SIA DCS protocols. The UDACT will report general, zone, or point The complete system may be converted to Class A with a CA-6075 module. The CA-6075 provides the hardware necessary to convert the remote annunciators through the Potter P-Link connection protocol, the NACs and the SLC to Class A operation. Potter Electric Signal Company, LLC · St. Louis, MO · Cust Service: 866-956-1211 · Tech Support: 866-240-1870 · Canada: 888-882-1833 · www.pottersignal.com PRINTED IN USA MKT. #8830001 - REV C 11/13 PAGE 1 OF 3 firealarmresources.com PFC-6075 FIRE ALARM CONTROL PANEL SLC Loop Accessories The control panel may be connected with up to seventy-five (75) addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device PSA PSHA FHA RHA DDA AB-6 AB-4 AIB ARB ASB Modules Description Analog Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot. Combination Analog Photo Electric Smoke/Heat Detector a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute Addressable Duct Smoke Detector 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors 4" round base that is mounted to an electrical box and wired for connection of one of the above sensors Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop Addressable Relay Base that contains two relays controlled by the SLC. One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The sounder follows the pattern sent to the device. Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4" square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module switches monitored power and is activated by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors. SCI Short Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. P-Link Devices Device RA-6075 RA-6500 LED-16 PSN-1000 RLY-5 SPG-1000 FCB-1000 FIB-1000 Description LCD/keypad remote annunciator with a metal enclosure and key lock. 160 Character LCD. Keypad remote annunciator with metal enclosure and key lock. LED remote annucniator capable of displaying alarms, supervisory, and trouble status for 16 zones. 10 Amp Intelligent power supply. 5 Form C Relay Card. Serial/Parallel Printer Card, Optional Rack Mount. Fire Communications Bridge, 1 may be added for remote IP Communicator. Fiber Interface Module, used in pairs to convert P-Link over multimode fiber, optional rack mount. PRINTED IN USA MKT. #8830001 - REV C 11/13 PAGE 2 OF 3 firealarmresources.com SLC Circuit Diagram Alarm Monitoring Station Ethernet UD-1000 Digital Alarm Communicator 3 Amp NAC Circuits CS/CHS Selectable Candela Ceiling Mount Stobe or Strobe/Horn S-24/HS-24 Selectable Candela Strobe or Strobe/Horn PFC-6075 FIRE ALARM CONTROL PANEL RA-6075 LCD Annunciator P-Link NACs SLC RLY-5 Relay Expander RA-6500 LCD Annunciator AE-8 8 Device Expansion Enclosure Input / Output (I/O) Circuits AB-6 Detector Base PSA Smoke Detector TRM-4 Twin Relay Module SLC Loop ASB-6 Analog Sounder Base PSHA Smoke Detector / Heat Detector AIB-6 Isolator Base RHA Heat Detector MOM-4 Monitored Output Module DCM-4 Dual Contact Module ARB-6 Analog Relay Base FHA Heat Detector SCI Short Circuit Isolator PRINTED IN USA CIZM-4 Conventional Initiating Zone Module PS-24 Smoke Detector SCM-4 Single Contact Module CO-12/24 Carbon Monoxide Detector MCM Miniature Contact Module MKT. #8830001 - REV C 11/13 firealarmresources.com APS-SA Addressable Pull Station PAGE 3 OF 3