User Guide for ams models including: TMD2636, EVM Miniature Proximity Sensor Module
The hardware consists of the EVM Controller, the TMD2636 EVM daughter card, and a USB interface cable. The EVM controller board provides power and I2C ...
The hardware consists of the EVM Controller, the TMD2636 EVM daughter card, and a USB interface cable. The EVM controller board provides power and I2C ...
File Info : application/pdf, 16 Pages, 698.22KB
DocumentDocumentUser Guide UG001002 TMD2636 TMD2636 EVM Miniature Proximity Sensor Module v1-00 · 2021-Jan-18 Content Guide Document Feedback TMD2636 Content Guide 1 Introduction ................................... 3 4.4 Auto Polling ..................................................9 4.5 Device ID Information ...................................9 1.1 Kit Content.................................................... 3 4.6 Log Status and Control Information............10 1.2 Ordering Information .................................... 3 4.7 "Prox" Tab...................................................11 2 Getting Started .............................. 4 5 Resources .................................... 14 3 Hardware Description ................... 5 6 Revision Information ................... 15 4 Software Description .................... 6 7 Legal Information......................... 16 4.1 Connect Software to Hardware .................... 6 4.2 System Menus.............................................. 7 4.3 System Level Controls ................................. 9 Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 2 Document Feedback TMD2636 Introduction 1 Introduction The TMD2636 evaluation kit comes with everything needed to evaluate the TMD2636. The device features advanced proximity measurement in a tiny and extremely thin optical land grid array module. 1.1 Kit Content Figure 1: Evaluation Kit Contents No. Item 1 TMD2636 Daughter Card 2 EVM Controller Board 3 USB Cable (A to Micro-B) 4 Flash Drive 1.2 Ordering Information Ordering Code TMD2636 EVM Description PCB with TMD2636 sensor installed Used to communicate USB to I2C Connects EVM controller to PC Include application installer and documents Description Miniature Proximity Sensor Module Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 3 Document Feedback TMD2636 Getting Started 2 Getting Started The software should be installed prior to connecting any hardware to the computer. Follow the instructions found in the Quick Start Guide (QSG). This loads the required driver for the USB interface and the device's graphical user interface (GUI). The balance of this document identifies and describes the controls available on the GUI. In combination with the TMD2636 datasheet, the QSG and application notes available on the ams website, www.ams.com, there should be enough information to allow evaluation of the TMD2636 device. Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 4 Document Feedback TMD2636 Hardware Description 3 Hardware Description The hardware consists of the EVM Controller, the TMD2636 EVM daughter card, and a USB interface cable. The EVM controller board provides power and I2C communication to the daughter card through a seven-pin connector. When the EVM controller is connected to the PC through USB, a green LED lights on to indicate the system is getting power. For schematics, layout and BOM information please see the documents included with the install located in the TMD2636 EVM folder (All Programs -> ams -> TMD2636 EVM -> Documents). Figure 2: Evaluation Kit Hardware Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 5 Document Feedback TMD2636 Software Description 4 Software Description The main window (Figure 3) contains the system menus, system level controls, device information and logging status. The main window contains only one tab "Prox" to configure the parameters to run proximity. The prox data and its average data is also plotted in this tab. The application polls the prox raw data continuously. Figure 3: GUI Main Window 4.1 Connect Software to Hardware On startup, the software automatically connects to the hardware. On successful initialization, the software displays a main window, containing controls pertinent to the connected device. If the software detects an error, an error window appears. If "Device not found or is unsupported" appears, verify the correct daughterboard is properly connected to the EVM controller board. If "Cannot connect to EVM board" appears, verify the USB cable is connected. When the EVM controller board is connected to the USB, a green LED lights on power up to indicate the USB cable is connected and providing power to the system. The LED will remain lit until the any software application opens the controller. The light will then be switched off so that it will not interfere with any light measurements. If the EVM board disconnects from the USB bus while the program is running, it displays an error message and then terminates. Reconnect the EVM board and restart the program. Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 6 Document Feedback TMD2636 Software Description 4.2 System Menus At the top of the window there are pull-down menus labeled "File", "Log", and "Help". The File menu provides basic application-level control. The Log menu controls the logging function, and the Help menu provides version and copyright information for the application. 4.2.1 File Menu The File menu contains the following functions: Figure 4: File Menu The Reread Registers function forces the program to re-read all of the control registers from the device and display them on the screen. This does not read the output data, because the program reads those registers continually while it is running. Click on the Exit command to close the main window and terminate the application. Any unsaved log data is cleared from memory. The application can also be close by clicking the red "X" in the upper right hand corner. 4.2.2 Log Menu The Log menu controls the logging function and saves the log data to a file. Log data accumulates in memory until discarded or written to a data file. Figure 5: Log Menu Click Start Logging to start the logging function. Each time the program polls the output information from the device, it creates a new log entry showing the raw data values, the values of various control Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 7 Document Feedback TMD2636 Software Description registers, and the values entered by the user into the text fields near the bottom right corner of the window. Click Stop Logging to stop the logging function. Once logging stops, the user may store the data in a file, or continue collecting additional data by clicking Start Logging again. The Log a Single Entry command causes logging to start, collect one single entry, and immediately stop again. This function is not available when logging is already running. Click Clear Log to discard any previously collected data. If there is data in memory, which has not been saved to disk, this function displays a prompt asking to verify it is OK to discard the data. If the log is active when this function executes, the log continues running after the existing data is discarded. Click Save Log to save the collected log data to a csv file. This stops the logging function, if it is active, and displays a file dialog box to specify where to store the logged data. The Log Status and Control Information section below describes the default file name, but you may change the file name if desired. 4.2.3 Help Menu The Help menu contains a single function: About. Figure 6: Help Menu The About function displays a dialog box (Figure 7) showing the version and copyright information for the application and library. Click the OK button to close this window and continue. Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 8 Figure 7: About Window Document Feedback TMD2636 Software Description 4.3 System Level Controls Immediately below the top menu bar there are checkboxes used to control the system level functions of the TMD2636 device. The Power On checkbox controls the PON function of the TMD2636. When this box is checked, the power is on and the device is running measurements according the settings in the Prox tab. When this box is unchecked, the power is off and the device does not operate. The Prox Enable checkbox enable the proximity measurement when checked and disable proximity measurement when unchecked. 4.4 Auto Polling The application automatically polls the TMD2636 raw data of the Prox. The Poll Interval at the right upper corner of the form displays the actually time between reads of the device. 4.5 Device ID Information The lower left corner of the window displays the ID number of the EVM Controller board, identifies the device being used. Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 9 Document Feedback TMD2636 Software Description 4.6 Log Status and Control Information The lower right corner of the window contains status information and controls for the logging function: Figure 8: Logging Status This section contains text boxes that are stored in the log file data and used to build the file name for the log file. If the data in these fields are changed, the new values are stored with any new data logged. The default file name is based on these values at the time the log file is written. If nothing is entered in these boxes they default to a period ("."). Sample default file name: TMD2636_1-2-3_Log_HH_MM_SS.csv From Application From User Input The Count value displayed is a count of the number of samples currently in the log buffer. The Elapsed Time value indicates the elapsed time since data logging started. The numeric box in the bottom right-hand corner sets a limit to the size of the collected dataset. You may select a value from the pull-down list, or enter a value manually. When the number of entries in the log reaches this value, the program will automatically stop logging and display a file dialog box to specify where to store the logged data. You may change the file name if desired. The maximum value that may be entered in this field is 32000. Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 10 Document Feedback TMD2636 Software Description 4.7 "Prox" Tab The main portion of the screen contains a tab labeled Prox. The controls in this tab are divided into 3 sections, each performing a separate function. Figure 9: Prox Tab 4.7.1 Prox Controls The PPULSE controls the number of pulses used for each prox cycle. The number of pulses is one more than the PULSE value and is displayed immediately to the right of the box. The PPULSE_LEN control sets the width of all pulses within the proximity cycle. Longer pulses result in increased proximity range and typically result in less electrical noise generated in the analog front end. The PGAIN control is pulldown menus that lets you control the gain stages of the proximity IR sensor. The PGAIN values are 1x, 2x, 4x and 8x. PLDRIVE control sets the drive strength of the IR VCSEL current. The values are 5,6,7,8 relating the drive current of 7 mA, 8 mA, 9 mA, 10 mA. The PWEN checkbox controls the proximity Wait feature. When this box is checked, the values for PWTIME and PWLONG determine the time between proximity cycles. When this box is unchecked, there is no wait period between proximity cycles and the values of PWTIME and PWLONG are ignored. Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 11 Document Feedback TMD2636 Software Description The PWTIME control sets the time to wait between prox cycles. PWTIME can be adjusted in 2.778 ms steps. The PWLONG checkbox controls the PWTIME factor. When this box is checked, the wait time between proximity cycles increases by a factor of 12x. The PDSELECT selects the photodiode to use for proximity detection. The values are "No photodiode", "Far photodiode", "Near Photodiode", and "Both photodiode". The POFFSET controls shift PDATA to remove crosstalk from the proximity data. The values range from -255 to 255. This value can be set manually, or it can be set by the Proximity offset calibration. The Auto Offset Adjust checkbox enables the function that automatically decrements the POFFSET value any time the PDATA value is 0. When this function is active, manual changes to the POFFSET control are disabled, and the program will read and update the POFFSET value each time it reads the PDATA value. The Calibration Group box. The Cal button triggers the sensor's proximity offset calibration sequence. This function automatically selects a POFFSET to remove crosstalk from PDATA. The Average checkbox enables proximity hardware averaging as selected with PROX_AVG during calibration when checked. The PRATE checkbox enables PRATE during calibration. It is useful when averaging is enabled. The APC function can be turned off with the Disable checkbox. This feature is used for hardware configurations with high crosstalk. When Auto Pulse Control is disabled, the range of the PDATA value is 0-1023. When the Disable checkbox is unchecked, the range of the PDATA value is 0-65535. The PROX_AVG control defines the number of ADC samples collected and hardware averaged during a proximity cycle. PRATE controls sets the duration of a single proximity sample. The time is equal to (PRATE + 1) * 88 s. The time, in microseconds, is displayed immediately under this control. 4.7.2 Prox Output Data The top right corner of the Prox tab displays the output data. This data is continuously read. The polling interval is shown above the tab. PDATA displays the Proximity ADC channel data counts. ProxAvg displays the proximity data after software average of the last 32 PDATA. StDev displays the calculated standard deviation of the last 32 PDATA samples displayed on the screen Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 12 Document Feedback TMD2636 Software Description 4.7.3 Prox Data Plot The remaining portion of the Prox tab is used to display a running plot of the collected PDATA and ProxAvg values. The last 350 values are collected and plotted on the graph. As additional values are added, the old values will be deleted from the left side of the graph. To start the plotting function, check the Enable Plot checkbox. Figure 10: Prox Data Plot Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 13 Document Feedback TMD2636 Resources 5 Resources For additional information regarding the TMD2636, please refer to the datasheet. For information regarding the installation of the TMD2636 EVM host application software please refer to the TMD2636 EVM Quick Start Guide. Designer's Notebooks dealing with various aspects of optical measurement and optical measurement applications are available. All content is available on the ams website www.ams.com. For further information, please refer to the following documents: TMD2636 Datasheet TMD2636 EVM Quick Start Guide (QSG) TMD2636 EVM User's Guide (this document) TMD2636 EVM Schematic Layout Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 14 Document Feedback 6 Revision Information Changes from previous version to current revision v1-00 Initial Release TMD2636 Revision Information Page Page and figure numbers for the previous version may differ from page and figure numbers in the current revision. Correction of typographical errors is not explicitly mentioned. Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 15 Document Feedback TMD2636 Legal Information 7 Legal Information Copyrights & Disclaimer Copyright ams AG, Tobelbader Strasse 30, 8141 Premstaetten, Austria-Europe. Trademarks Registered. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. Demo Kits, Evaluation Kits and Reference Designs are provided to recipient on an "as is" basis for demonstration and evaluation purposes only and are not considered to be finished end-products intended and fit for general consumer use, commercial applications and applications with special requirements such as but not limited to medical equipment or automotive applications. Demo Kits, Evaluation Kits and Reference Designs have not been tested for compliance with electromagnetic compatibility (EMC) standards and directives, unless otherwise specified. Demo Kits, Evaluation Kits and Reference Designs shall be used by qualified personnel only. ams AG reserves the right to change functionality and price of Demo Kits, Evaluation Kits and Reference Designs at any time and without notice. Any express or implied warranties, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose are disclaimed. Any claims and demands and any direct, indirect, incidental, special, exemplary or consequential damages arising from the inadequacy of the provided Demo Kits, Evaluation Kits and Reference Designs or incurred losses of any kind (e.g. loss of use, data or profits or business interruption however caused) as a consequence of their use are excluded. ams AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of ams AG rendering of technical or other services. RoHS Compliant & ams Green Statement RoHS Compliant: The term RoHS compliant means that ams AG products fully comply with current RoHS directives. Our semiconductor products do not contain any chemicals for all 6 substance categories plus additional 4 substance categories (per amendment EU 2015/863), including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, RoHS compliant products are suitable for use in specified lead-free processes. ams Green (RoHS compliant and no Sb/Br/Cl): ams Green defines that in addition to RoHS compliance, our products are free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) and do not contain Chlorine (Cl not exceed 0.1% by weight in homogeneous material). Important Information: The information provided in this statement represents ams AG knowledge and belief as of the date that it is provided. ams AG bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. ams AG has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. ams AG and ams AG suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. Headquarters ams AG Tobelbader Strasse 30 8141 Premstaetten Austria, Europe Tel: +43 (0) 3136 500 0 Please visit our website at www.ams.com Buy our products or get free samples online at www.ams.com/Products Technical Support is available at www.ams.com/Technical-Support Provide feedback about this document at www.ams.com/Document-Feedback For sales offices, distributors and representatives go to www.ams.com/Contact For further information and requests, e-mail us at ams_sales@ams.com Eval Kit Manual · PUBLIC UG001002 · v1-00 · 2021-Jan-18 16 16Microsoft Word 2016 Microsoft Word 2016