Quick start guide version 1.0

In-wall dimmer 2-pole

Requires a Heimgard hub

What is in the box
A. In-wall dimmer 2-pole

Device overview
FRONT VIEW

B. Join/ Reset button

C. Min.Set button

Connection diagram overview

Notes for the diagrams: L in - Live lead input terminal N in - Neutral lead input terminal L out - Live lead output terminal

N out - Neutral lead output terminal S1 - External switch terminal COM - Terminal for grounding to the switch connected to the dimmer

Switch input

Live lead input Neutral lead output Live lead output

Neutral lead input

Installation and wiring

Electronical properties
· Load (A) 1.8 Max · Voltage (V) 100-240

· Voltage type AC · Power source AC

This device should be installed by a licensed electrician in a manner that conforms to local regulations and building codes.
WARNING: Electrical power must be switched off during installation
FIRST ENSURE THE POWER IS OFF at the main circuit breaker, and then test the wires with a probe or multimeter to verify.
Connect the input power and output wires to the correct device terminals. Follow the connection diagram and instructions on the next page.

Wiring diagram
For installation follow the wire diagrams. Option 1: Without a connected push switch

Option 2: With a connected push switch LV

L in

N in

L in

L out

N out

N in L out
N out

Option 3: With a connected push switch

L in

N in

L out

N out

Startup brightness
This is how bright your lights are when you turn your lights on.

1.

Adjust the brightness of your lights to the desired level between 1% - 50%.

2.

Double Click the Min. Set button on the dimmer to set the brightness.

3.

To delete the startup brightness value set the light brightness to minimum

brightness (0%) and double-click the

Min. Set button.

Minimum brightness
This sets the minimum brightness level on your dimmer.

1.

Adjust the brightness of your lights to the desired minimum brightness.

2.

Press and Hold the Min. Set button for 3 seconds or until connected light flashes

to set the brightness value.

3.

To delete the minimum brightness value set the light brightness to maximum

brightness (100%) and press and

hold down the Min. Set button until

connected light flashes.

Connecting to the Hub
These steps are to be followed after the dimmer has been properly installed and wired by a certified electrician.

1.

At the circuit breaker, turn off the power to the dimmer.

2.

Open the Heimgard app and follow the steps listed here to connect to your

device

Manage Devices

3.

Turn the circuit breaker power on to power up your dimmer.

It will automatically enter pairing mode. The connected light will flash 2 times to indicate powering on.

4.

When the connected light flashes 5 times and then remains on, the device

has been found in your app.

5.

You will now see the In-wall dimmer in your new devices. Configure the dimmer

by giving it a name and adding it to a

room.

Your light is now able to be controlled by your app.

Factory Reset

If your dimmer has previously been connected to a different Hub, you may need to perform a factory reset.

1.

Quickly press the reset button (B) 5 times continuously.

If you do not have access to the reset button, turn the power supply on and off 5 times. This could be done either from the circuit breaker in the fuse box or from the connected wired wall switch.

Press 5 times

2.

The device that is connected to this dimmer will turn on/off 3 times to

indicate successful reset.

You will have to reconfigure your device.

Note: make sure your connected device is functioning properly.

Technical specifications

Load Symbol

Compatible Load Type

Load Type

Maximum Load

Remarks

Dimmable LED lamps

200W @ 230V 100W @ 110V

Due to variety of LED lamp designs, maximum number of LED lamps is further dependent on power factor result when connected to dimmer

LED drivers

200W @ 230V 100W @ 110V

Maximum permitted number of drivers is 200W divided by driver nameplate power rating

Incadescent lighting, HV Halogen lamps
Low voltage halogen lighting with electronic transformers

400W @ 230V 200W @ 110V
200W @ 230V 100W @ 110V

Need help?

Website: Email: Facebook: Telephone:

heimgard.com/support support@heimgard.com facebook.com/heimgardnorge/ +47 649 44 422

Visit heimgard.com for more information and tips on how to use.

Important safety information

1.

Read through these instructions and follow accordingly.

2.

Clean only with dry soft cloth. Household cleaners and solvents

can damage the finish on your device.

3.

Do not install too close to any heat sources such as radiators, heat

registers, stoves or other device that produce heat.

4.

Do not use this device near water.

5.

Warning: To reduce the risk of fire or electric shock, do not expose

this device to rain or moisture.

6.

Do not expose device to dripping or splashing.

7.

Protect the attached cables from being walked on or pinched,

particularly at plugs, convenience receptacles, and the point the

exit the apparatus.

8.

Only use attachments/accessories specified by the manufacturer.

9.

All servicing should be performed by qualified service personnel.

Servicing is required when the device has been damaged in

any way.

10. Operating temperature: -10°C to +50°C

11. Operating relative humidity: < 95% RH (no condensation)

Dispose the product properly at the end of life. This is electronic waste which should be recycled accordingly.