Owner's Manual for MEAN WELL models including: RPS-30-3.3, RPS-30-5, RPS-30-7.5, RPS-30-12, RPS-30-15, RPS-30-24, RPS-30-48, RPS-30 Series 30W Reliable Green Medical Power Supply, RPS-30 Series, 30W Reliable Green Medical Power Supply, Reliable Green Medical Power Supply, Green Medical Power Supply, Medical Power Supply, Power Supply, Supply
MEAN-WELL USA, INC. - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 4 Pages, 152.44KB
DocumentDocument30W Reliable Green Medical Power Supply RPS-30 series User's Manual EN 60601-1 IEC 60601-1 8 ANSI/AAMI ES60601-1 BS EN/EN60601-1 IEC60601-1 TPTC004 Features 3"×2" compact size Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1 Suitable for BF application with appropriate system consideration Cooling by free air convection EMI class B for class configuration No load power consumption<0.1W Extremely low leakage current Protections: Short circuit / Overload / Over voltage Lifetime > 105K hours Operating altitude up to 4000 meters 3 years warranty ++ Applications Oral irrigator Hemodialysis machine Medical computer monitors Sleep apnea devices GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx Description RPS-30 is a 30W highly reliable green PCB type medical power supply with a high power density on the 3" by 2" footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 92% and the extremely low no load power consumption is down below 0.1W. RPS-30 is able to be used for Class(no FG) system design. The extremely low leakage current is less than 80A. In addition, it conforms to international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated "patient contact" medical system equipment.a Model Encoding RPS- 30 - 3.3 Output voltage Rated wattage Series name Downloaded from Arrow.com. File Name:RPS-30-SPEC 2024-11-22 30W Reliable Green Medical Power Supply RPS-30 series SPECIFICATION ORDER NO. RPS-30-3.3 RPS-30-5 RPS-30-7.5 RPS-30-12 RPS-30-15 RPS-30-24 RPS-30-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 48V RATED CURRENT 6A 6A 4A 2.5A 2A 1.25A 0.625A CURRENT RANGE 0 ~ 6.6A 0 ~ 6.6A 0 ~ 4.4A 0 ~ 2.75A 0 ~ 2.2A 0 ~ 1.375A 0 ~ 0.687A RATED POWER 19.8W 30W 30W 30W 30W 30W 30W OUTPUT PEAK LOAD(10sec.) Note.2 21.8W 33W 33W 33W 33W 33W 33W RIPPLE & NOISE (max.) Note.3 80mVp-p 80mVp-p 80mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ.RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION 3.1~3.6V ±2.0% ±0.5% ±1.0% 4.7~5.5V ±2.0% ±0.5% ±1.0% 7.12~8.3V ±2.0% ±0.5% ±1.0% 11.4~13.2V ±2.0% ±0.5% ±1.0% 13.5~16.5V ±2.0% ±0.5% ±1.0% 22.8~27.6V ±1.0% ±0.5% ±1.0% 45.6~52.8V ±1.0% ±0.5% ±1.0% SETUP, RISE TIME 200ms, 30ms / 230VAC 200ms, 30ms / 115VAC at full load HOLD UP TIME (Typ.) 30ms / 230VAC 16ms / 115VAC at full load VOLTAGE RANGE Note.5 80 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 80% 82% 84% 88% 89% 89.5% 92% AC CURRENT (Typ.) 1A / 115VAC 0.5A / 230VAC INRUSH CURRENT (Typ.) OLD STAR 30A/115VAC 60A/230VAC LEAKAGE CURRENT(max.) Note.6 Touch current< 80A/264VAC OVERLOAD 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE WORKING TEMP. 3.8~5V 5.7~6.8V 8.6~11.3V 13.8~16.2V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 17.2~20.3V 28.4~32.4V 55.2~64.8V WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03% / (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.7 4000 meters SAFETY STANDARDS IEC 60601-1:2005+A1+A2, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2 CAN/CSA C22.2 No. 60601-1:2014+A2, EAC TP TC 004 approved; Design refer to BS EN/EN60335-1(by request) ISOLATION LEVEL Primary-Secondary: 2xMOPP WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P: 4KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note EMC EMISSION SAFETY & EMC (Note. 8) Conducted emission Radiated emission Harmonic current Voltage flicker BS EN/EN55035, BS EN/EN60601-1-2 BS EN/EN55011 (CISPR11) BS EN/EN55011 (CISPR11) BS EN/EN61000-3-2 BS EN/EN61000-3-3 Class B Class B Class A ----- Parameter Standard Test Level / Note EMC IMMUNITY ESD RF field susceptibility EFT bursts Surge susceptibility Conducted susceptibility Magnetic field immunity BS EN/EN61000-4-2 BS EN/EN61000-4-3 BS EN/EN61000-4-4 BS EN/EN61000-4-5 BS EN/EN61000-4-6 BS EN/EN61000-4-8 Level 4, 15KV air ; Level 4, 8KV contact Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) Level 3, 2KV Level 4, 2KV/Line-Line Level 3, 10V Level 4, 30A/m MTBF Voltage dip, interruption BS EN/EN61000-4-11 3550.0K hrs min. Telcordia SR-332 (Bellcore) ; 628.7K hrs min. 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods MIL-HDBK-217F (25) OTHERS DIMENSION (L*W*H) PACKING 76.2*50.8*24mm or 3" * 2" *0.945" inch 0.09Kg; 120pcs/11.8Kg/0.94CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Touch current was measured from primary input to DC output. 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:RPS-30-SPEC 2024-11-22 30W Reliable Green Medical Power Supply RPS-30 series Block Diagram EMI FILTER RECTIFIERS POWER I/P & & SWITCHING RECTIFIER FILTER O.L.P. CONTROL Derating Curve 100 80 60 50 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () Static Characteristics 100 90 80 70 60 50 40 80 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz LOAD (%) fosc : 65KHz RECTIFIERS +V & FILTER -V DETECTION CIRCUIT O.V.P. LOAD (%) Downloaded from Arrow.com. File Name:RPS-30-SPEC 2024-11-22 30W Reliable Green Medical Power Supply RPS-30 series 50.8 44.45 3.175 Mechanical Specification (Unit: mm , tolerance ± 1mm) 3.175 FS1 AC FUSE T2.5A/250V 3 2 1 CN1 Top View 76.2 69.85 HS2 CN2 1 2 LED SVR1 4-3.2 3 max. 24 Side View AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. Assignment Mating Housing Terminal 1 AC/N 2 No Pin JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 3 AC/L DC Output Connector (CN2) : JST B2P-VH or equivalent Pin No. Assignment Mating Housing Terminal 1 +V 2 -V JST VHR JST SVH-21T-P1.1 or equivalent or equivalent Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:RPS-30-SPEC 2024-11-22