Planika Prime Fire 590, 790, 990, 1190

Introduction

The Planika Prime Fire is a decorative device that creates real fire. This manual applies to the installation and operation of the Prime Fire 590, 790, 990, and 1190 burner only. Always consult local regulations for fireplaces.

Safety Instructions

  1. For indoor use and in housing only. Minimum temperature of use is 10°C.
  2. Natural air exchange rate in room: minimum 1/h.
  3. Do not use the device in humid and drafty spaces.
  4. Do not cover top ventilation openings of the device.
  5. No heat-sensitive and flammable objects can be placed within a 1-meter radius from and directly above the device.
  6. Do not place any objects on the top of the device.
  7. It is recommended to place a CO2 or dry powder fire extinguisher nearby the device.
  8. For service purposes, the surrounding must allow for easy removal of the device.
  9. Keep children, animals, and unauthorized persons away from the device.
  10. Keep the packaging and manuals for future use.
  11. Do not turn on the device in case of fuel spill.
  12. Do not interfere in the fuel filler when the device is operating.
  13. Do not interfere in the device construction.
  14. Do not touch the filament and other hot elements.
  15. Do not transport the device if fueled.
  16. Do not leave an operating device unattended.

Technical Specifications

BurnerL [mm]D [mm]H [mm]Minimum Room Size [m³]Heat [kW]
Prime Fire 590590280220313.1
Prime Fire 790790444.4
Prime Fire 990990707.0
Prime Fire 11901190949.4

Parts List

ItemDescriptionQuantity
ABurner1x 590, 790, 990, 1190
BGlass shield2x 590, 790, 990
CSmall glass holder3x 1190
DConnector screw1
ERemote control1
FService cable1
GFuel pump1
HInstallation and user's manual1
IWindscreen connector type 14x 590, 790, 990, 1190
JGlass panel2x 590, 790, 990, 1190
KTall glass holder
LWindscreen connector type 24x 590, 790, 990, 1190
MWasher

Installation Requirements

Clearances and Materials

The fireplace surrounding must be made of non-flammable materials and insulated from any flammable elements of the construction. Use only fasteners and adhesives that are resistant to high temperature.

Diagrams show minimum clearance requirements:

Enclosure and Electrical

The space under the device must be closed.

Electrical connection requires a minimum of 3x1.5 mm² cable, 230 V, 50 Hz, with PE grounding.

Installation Options

Various installation options are shown, involving the use of glass shields (Item B) and optional tempered glass panels (Item I).

Ventilation

Diagrams illustrate ventilation requirements for different configurations (TV and AC). Ensure adequate airflow, with minimum area requirements such as 175 cm² and a minimum diameter of Ø150 mm for ventilation openings.

Operation

Control Panel

The control panel features:

LED Indicator States:

Fuel Filling

Follow these steps to fill the fuel tank:

  1. Ensure the tank is empty or ready for refilling. Open the fuel inlet (I). Connect the pump hose 'a' (audible click) and power cable 'b' (II). ATTENTION: Do not refuel while the flame is ignited.
  2. Place the fuel container on a stable surface. Insert the pump hose 'c' (III) into the container. Press and hold the pump button (IV) to start refuelling. The pump will stop automatically when the tank is full (audible signal + READY LED).
  3. Disconnect the power cable 'b'. To disconnect the pump, hold the end of hose 'a' and press the button marked on the pump (V). Close the fuel inlet.
  4. Shake any remaining fuel from hose 'c' back into the container and store the pump in its bag (VI).

Flame Ignition

The green READY LED indicates the device is ready for ignition. Press and hold START for 3 seconds. Ignition takes 2-10 minutes. A faint smell of ethanol vapors may be present. When the READY LED turns off, the flame is ignited and the device has reached operating temperature.

Flame Height Regulation

When the flame is lit, press ECO to lower the flame (two signals). Press ECO again to increase flame height (one signal).

ATTENTION: If the device temperature is too high, the flame will automatically lower (ECO), and regulation will be blocked. If temperature continues to rise, the device will turn off.

Flame Extinguishing

Press STOP to extinguish the flame (one signal + HOT LED). The device can be reignited after cooling down (indicated by the green READY LED).

Fast Start

The FAST START function enables faster flame ignition. It increases standby power consumption by approximately 60 W. This function is enabled by default.

Troubleshooting and Error Messages

Some alarms are accompanied by a sound signal. Press START/STOP to mute.

Lp.Diodes (Panel)Action / Solution
1.HOT, FUEL, READYDevice is cooling down. Wait for the green READY LED.
2.HOT, FUEL, READYDevice ran out of fuel during operation. Device is cooling down. Wait for the red diode to turn off. Refill the tank.
3.HOT, FUEL, READYIf spillage occurred during refuelling: disconnect the fuel pump, wipe visible liquid. Mute device (START/STOP) and wait at least 1 hour. Press ECO for 10 seconds. If the message persists, turn off the device and wait at least 24 hours.
4.HOT, FUEL, READYError during flame ignition: ignition time exceeded. Press ECO for 10 seconds.
5.HOT, FUEL, READYDevice error. Press ECO for 10 seconds.
6.HOT, FUEL, READYTank overflow. Contact Service Department.
7.HOT, FUEL, READYRoom temperature too low (<10°C) or device error. Heat the room. Press ECO for 10 seconds. Wait for the green READY LED. Press ECO on the control panel for 10 seconds.

Fuel and Maintenance

Fuel Recommendations

Use only ethanol fuel produced from plants via two-time alcohol distillation, consisting of 95-96.6% ethanol by volume. Fanola is the recommended fuel with pharmacological purity.

DO NOT USE: Synthetic petroleum-based fuels (contaminated, emit odors, can damage the fireplace), fuels with 100% ethanol by volume, gel, or aromatic fuels.

Cleaning

Clean with a damp cloth and mild detergent only when the device is turned off and cooled.

Service

Keep the provided USB cable for service. Contact service@planikafires.com for assistance.

Models: 590, 790, 990, 1190, 590 Prime Fire Bioethanol Fireplace, 590, Prime Fire Bioethanol Fireplace, Fire Bioethanol Fireplace, Bioethanol Fireplace, Fireplace

File Info : application/pdf, 28 Pages, 1.80MB

PDF preview unavailable. Download the PDF instead.

installation user manual

References

Microsoft Word dla Microsoft 365

Related Documents

Preview Planika Forma 800 Right Corner Bioethanol Fireplace with BEV® Technology
Explore the Planika Forma 800 Right Corner fireplace, featuring the innovative Prime Fire 2.0 590 Automatic BEV® Burner. This Net Zero fireplace offers zero clearance installation, mobile app control, and remote operation for a modern, eco-friendly ambiance.
Preview Planika Forma 800 Single-Sided Fireplace: Features and Specifications
Discover the Planika Forma 800 Single-Sided fireplace, featuring BEV Technology®, zero clearance design, automatic refilling, and remote control options for a modern and efficient heating solution.
Preview Planika Vitro Room Divider: Concentric Flue Bioethanol Fireplace with BEV Technology
Discover the Planika Vitro Room Divider, a Net Zero concentric flue fireplace featuring automatic BEV® burner technology for clean, efficient ethanol burning. Explore its high-view design, safety features, and smart control options.
Preview Planika Vitro Left Corner: BEV® Technology Bioethanol Fireplace
Discover the Planika Vitro Left Corner, a Net Zero bioethanol fireplace featuring automatic BEV® burner technology, high-view design, and smart control options. Explore its specifications and modern elegance.
Preview Planika UFO Freestanding Fireplace with FLA4 990 Automatic BEV Burner
Discover the Planika UFO Freestanding fireplace, featuring the FLA4 990 Automatic BEV® Burner for a Net Zero fireplace experience. Learn about its features, specifications, and control options including remote and mobile app control.
Preview Planika Forma 1000 Single-Sided: BEV® Technology Net Zero Fireplace
Discover the Planika Forma 1000 Single-Sided fireplace, a Net Zero solution featuring advanced BEV® Technology. This fireplace offers seamless integration with its zero clearance design, automatic fuel refilling, convenient mobile app and remote control, and an intuitive touch panel. Enhance your space with adjustable flame settings and optional decorative logs for a sophisticated ambiance.
Preview Planika Neo 1000 Burner: Automatic BEV Fireplace
Discover the Planika Neo 1000 Burner, an automatic BEV fireplace offering net-zero emissions, innovative design, and remote control for a captivating flame experience. Features include a foamed glass burner, integrated control panel, and decorative log options.
Preview Planika Vitro Right Corner: Net Zero Bioethanol Fireplace with BEV® Technology
Discover the Planika Vitro Right Corner, a Net Zero bioethanol fireplace featuring advanced BEV® Technology for clean, efficient, and safe flames. Explore its high-view design, concentric flue system, and smart control options.