User Manual for VISION TECH SHOP models including: TPD Series, TPD-12, Interface Scale, TPD Series TPD-12 Interface Scale
TPD Interface Scale – VisionTechShop
File Info : application/pdf, 21 Pages, 780.29KB
DocumentDocumentTPD Interface Scale V1.1 TPD Series Interface Scale Operation Manual CONTENTS 1. INTRODUCTION----------------------------------------------------------------------------- - 1 2. INSTALLATION------------------------------------------------------------------------------- - 1 - 2.1 Installation------------------------------------------------------------------------------ - 1 2.2 Leveling--------------------------------------------------------------------------------- - 1 2.3 Power Connection-------------------------------------------------------------------- - 1 2.4 Rechargeable battery operation-------------------------------------------------- - 1 - 2.4.1 Charging the battery---------------------------------------------------------- 2 2.4.2 Battery maintenance-------------------------------------------------------- - 2 3. KEYS DESCRIPTION------------------------------------------------------------------------ 2 4. DISPLAY SYMBOLS------------------------------------------------------------------------ - 2 5. OPERATION------------------------------------------------------------------------------------ 3 5.1 Switching on/off----------------------------------------------------------------------- - 3 5.2 Zeroing---------------------------------------------------------------------------------- - 3 5.3 Using Tare------------------------------------------------------------------------------ - 3 5.4 Select Weighing Units--------------------------------------------------------------- - 3 5.5 Back light Setting--------------------------------------------------------------------- - 4 5.6 Power auto off------------------------------------------------------------------------- - 4 5.7 Bluetooth Operation (Optional)--------------------------------------------------- - 5 5.7.1 Bluetooth Testing Tool Installation-------------------------------------- - 5 5.7.2 CON1 Communication Protocol Testing------------------------------- - 5 5.7.3 CON2 Communication Protocol Testing------------------------------- - 7 5.7.4 ASK Command Testing---------------------------------------------------- - 9 5.8 POS/ECR protocol selection----------------------------------------------------- - 11 6 PARAMETER SETTING------------------------------------------------------------------- - 12 6.1 MENU BLOCK----------------------------------------------------------------------- - 13 7. DIAGRAM: Serial interface---------------------------------------------------------------- 14 8. SPECIFICATION----------------------------------------------------------------------------- 15 9. DIMMENSIONS(inch/mm)----------------------------------------------------------------- 16 10.ERROR MESSAGE----------------------------------------------------------------------- - 17 - TPD Series Interface Scale Operation Manual 1. INTRODUCTION The TPD series interface scale that amplifies signals from a load cell, converts it to digital data and displays it as a mass value It is suitable for general weighing applications 15 mm LCD with white LED back light display Standard RS232 port can be connected to computer, ECR or POS Capacity 6 kg to 30 kg (12 lb to 60 lb) 2. INSTALLATION 2.1 Installation Remove transport lock from bottom of the scale base Place the scale on a level surface Install the stainless steel pan on top of the plastic pan 1 Insert the pole (1) to pole bracket (3) Fixing the pole(1) with screw (2) 2 2.2 Leveling 3 The scale is equipped with a level indicator located back side of device. Use the adjustable leveling feet located on the bottom of the scale until the bubble appears in the center of the indicator. Level bubble 2.3 Power Connection Connect the adaptor pin into the indicator adaptor jack. Adaptor jack is locating below the left side of the scale. Adaptor connects into your AC power socket. Plugable equipment must be installed near an easily accessible socket outlet with a protective ground/ earth contact. 2.4 Rechargeable battery operation Note: Please charge the battery before using the scale for the first time. The symbol BATT on the weight display indicates that the battery is getting low. it's time to charge the battery with the AC power. If scale goes on being used without proper charging, <BAT-LO> words will flicker on the display. Approximately 1 hours of instrument usage are left; afterwards it will shut off automatically. -1- TPD Series Interface Scale Operation Manual Please use the supplied battery charger for charging the battery immediately,or scale cannot be used. 2.4.1 Charging the battery Before the first use, the battery should be charged by connecting it to the mains power supply for at least 10 hours. When the scale is plugged into the mains power the internal battery will be recharged. Verify that the AC power socket outlet is properly protected. Right side of the weight display there is an charging LED to indicate the status of battery charging Charge status of rechargeable battery is indicated by the LED display. Red: Charging storage battery Green: Rechargeable battery is completely charged 2.4.2 Battery maintenance Do not use any other type of power adaptor than the one supplied with the scale. Recharge battery should be charged in every three months when not in use. If the scale is not used for an extended period of time,remove the battery from the battery compartment to avoid leakage. Store the battery in a sealed bag or box in a dry, temperate environment. 3. KEYS DESCRIPTION Keys Description 1)On/Off key,Used to switch on/off the scale. 2)Zero key,Used to clear and zero the display. 3) Enter key, Used to confirm selection in parameters option. 4)Left arrow key. Used to shift the location and move the digit to the left. 1)Tare key,Used to perform a tare function, Subtracts weights. 2)Value increment key. Used to change the selected digit value. 3)Set up key,Used to enter setup menu setting. 4)To change the menu option in menu setting. 1)Units key,Used to change weighing units(kg/lb/oz). 4. DISPLAY SYMBOLS CHARG E STABLE NET ZERO kg lb oz BATT Charging indicator,indicates scale has been connected with power Stable indicator. Indicates the scale weight is stable. Net indicator. Indicates scale is displaying the net weight. Zero indicator.Indicates the scale is at zero. Indicates the unit of measure in use (kilogram). Indicates the unit of measure in use (pounds). Indicates the unit of measure in use (ounces). Bluetooth indicator,Indicates the scale is in Bluetooth mode Battery low indicator,Indicates the battery need to be charged -2- TPD Series Interface Scale Operation Manual 5. OPERATION 5.1 Switching on/off Switch on the scale by pressing key,Display will be show the scale version and then come to normal weighing mode. To switched off the scale, press key again. 5.2 Zeroing Environmental conditions can lead to the balance exactly zero in spite of the platform not taking any strain. However, you can set the display of your balance to zero any time by pressing key and therefore ensure that the weighing starts at zero. 5.3 Using Tare To enable Tare function, it's required to enter parameters to select f4 tare >ON, Before access to the parameter,it need to press the calibration switch that is locating below the scale. The weight of any container can be tared by pressing button so that with subsequent weighing the net weight of the object being weighed is always displayed. Taring a container Load weight on the platform. Press key. Zero is displayed, and tare is subtracted. The [] indicator above Net indicator appears. Remove weight on the platform. Tared weight is displayed. It can set only one tare value. It will be shown with a minus value. Clearing tare To clear the tare value, remove the load from the platform Press key. Zero is displayed, The [] indicator above Net indicator disappears ,tare weight is cleared. 5.4 Select Weighing Units By pressing key in turn in normal weighing mode,it can convert the weighing units (kg/lb/oz),the relative symbol will turn on in the display. -3- TPD Series Interface Scale Operation Manual 5.5 Back light Setting It allows choosing the back light operation. 1 Press key during that start up ,display will be show "F0 BL" 2 Press key to enter. 3 Press key to change the settings back light display mode to Auto/Off/On. 4 Press Display AUTO oFf on key to confirm. Description Backlight will be turned on, when start to use or when weight is not in zero. Backlight function will be turned off Backlight will be always turned on Note:If battery is getting low, the backlight function will not available 5.6 Power auto off 1 Press key during that start up ,display will be show "F0 BL". 2 Press key to select the menu until display show "F1 OFF". 3 Press key to confirm. 4 Press key to select the options. off F1 OFF 3 10 30 To set auto off function turn off, for scale always on Set to turn off 3 minutes later Set to turn off 10 minutes later Set to turn off 30 minutes later -4- TPD Series Interface Scale Operation Manual 5.7 Bluetooth Operation (Optional) 5.7.1 Bluetooth Testing Tool Installation Note: The following steps used for testing communication (only BLE Utility available for testing ) Turn on the BLE Utility software in your phone, it can be download from AppGallery Scale should be in the allowed limits of the distance to connect Bluetooth. 5.7.2 CON1 Communication Protocol Testing 1 Turn on the scale. 2 Press key during that start up ,display will be show "F0 BL". 3 Press key until display show "F2 COM". 4 Press key to confirm,display will be show "BT" 5 Press key to enter,display will be show "CON1" 6 Press key to confirm,display show "F2 COM". 7 Press key to select "BACK" option. 8 Press key to confirm and back to normal weighing mode. Testing steps in the mobile phone 1 Tab the connect button in your mobile phone to connect the Bluetooth module 2 Select the Unknown Service the last but one 3 Tab it and turn on the icon,Once set it successfully ,The [] indicator above[ ] Bluetooth indicator in the scale appears. 4 Tab logs ,the weighing data will be show -5- TPD Series Interface Scale Operation Manual -6- TPD Series Interface Scale Operation Manual 5.7.3 CON2 Communication Protocol Testing 1 Turn on the scale. 2 Press key during that start up ,display will be show "F0 BL" 3 Press key until display show "F2 COM" 4 Press key to confirm,display will be show "BT" 5 Press key to enter,display will be show "CON1" 6 Press key to select "CON 2 " 7 Press key to confirm,display show "STA " 8 Press key to confirm 9 Press key to select "BACK" option 10 Press key to confirm and back to normal weighing mode. Testing steps in the mobile phone 1 Tab the connect button in your phone to connect the Bluetooth module. 2 Select the Unknown Service the last but one . 3 Tab it and turn on the icon,Once set it successfully ,The [] indicator above[ ] Bluetooth indicator in the scale appears . 4 Tab logs ,the weighing data will be show. -7- TPD Series Interface Scale Operation Manual -8- TPD Series Interface Scale Operation Manual 5.7.4 ASK Command Testing 1 Turn on the scale. 2 Press key during that start up ,display will be show "F0 BL". 3 Press key until display show "F2 COM". 4 Press key to confirm,display will be show "BT" 5 Press key to enter,display will be show "CON1" 6 Press key until display show "ask" 7 Press key to confirm,display show "F2 COM". 8 Press key to select "BACK" option. 9 Press key to confirm and back to normal weighing mode. Testing steps in the mobile phone 1 Tab the connect button in your phone to connect the Bluetooth module 2 Select the Unknown Service the last but one 3 Tab it and turn on the icon,Once set it successfully ,The [] indicator above[ ] Bluetooth indicator in the scale appears. 4 Tab logs and Entered the Command to receive the corresponding data Command W: read data Command TARE: Tare Command ZERO: Zero -9- TPD Series Interface Scale Operation Manual - 10 - TPD Series Interface Scale Operation Manual 5.8 POS/ECR protocol selection 1 Turn on the scale. 2 Press key during that start up ,display will be show "F0 BL" 3 Press key until display show "F2 COM" 4 Press key to confirm,display will be show "BT" 5 Press key to select "port" option 6 Press key to confirm,display show "off" 7 Press key until display show "cas 2" 8 Press key to confirm 9 If necessary, Press key to select protocol from type 0 ~ type 6 (TYPE 0,2,4,5,6) 10 Press key to confirm,display show "F2 COM" 11 Press key to select "BACK" option 12 Press key to confirm and back to normal weighing mode. - 11 - TPD Series Interface Scale Operation Manual 6 PARAMETER SETTING Enter into the Menu Press key during that start up ,display will be shown "F0 BL" Enter to Selected Menu Press , it can confirm which will be shown displayed. Select the Menu Press key to choose menu block one by one. Return to Weighing Mode Press key to select "BACK" option in parameters to escape from the menu and back to normal weighing mode. To access the technical parameters F4 TARE & TECH,it's required to press the calibration switch, switch is locating below the scale - 12 - TPD Series Interface Scale Operation Manual 6.1 MENU BLOCK Menu F0 BL F1 OFF F2 COM F3 Isn F4 tare TECH OFF ON AUTO off 3 10 30 BT Sub-Menu CON1 Description To set backlight function Auto off function disable Scale will be auto off three minutes later Scale will be auto off 10 minutes later Scale will be auto off 30 minutes later Continuous Protocol 1 Port CON COUT 2 STA CAS ACT PAS ask off CAS 2 CON1 CON COUT 2 STA CAS ACT PAS ask off CAS Type 0 2 Type 2 Type 4 Type 5 Type 6 Continuous Protocol 2 Send stable weighing data CAS Active Protocol CAS Passive Protocol Ask mode 1) Command W: read data 2) Command TARE: Tare 3) Command ZERO: Zero Bluetooth Communication port off N.A Continuous Protocol 1 Continuous Protocol 2 Send stable weighing data CAS Active Protocol CAS Passive Protocol Ask mode 1) Command W: read data 2) Command TARE: Tare 3) Command ZERO: Zero RS232 Communication port off CAS POS /ECR protocol To show the internal counts OFF To disable tare function *ON To enable tare function For any approved version,it's required to press the calibration switch APPROV CPA CPA approval OIML OIML approval - 13 - TPD Series Interface Scale Operation Manual BACK P1 CAL NTEP NONE SLSI CAL KG CAL LB NTEP approval None approval SLSI approval Calibration P2 RES P3 CAP 3000\3000R\ 3000I/6000 6kg (12 lb) 12kg(30 lb) Set external resolution Set Scale Capacity 30kg(60 lb) P4 GRA Set the local gravity P5 sta On OFF Multi-Tare operation enable Multi-Tare operation disable Escape from setting menu and back to normal weighing mode Note: To calibrate in "kg" or "lb" unit, capacity will be show in kg or lb values. Default setting is marked by * 7. DIAGRAM: Serial interface Pin Pin Pin RXD TXD GND 9pin D Connector: Scale Pin 2 Pin 3 Pin 5 Input Output Receiving data Transmission data Signal ground Computer Pin 3 Pin 2 Pin 5 - 14 - TPD Series Interface Scale Operation Manual 8. SPECIFICATION MODEL Maximum Capacity Minimum Capacity Readability Max. Divisions TPD-12 12 lb / 6 kg / 192 oz TPD-30 30 lb / 12 kg /480 oz 0.04 lb / 20 g / 1 oz 0.1 lb / 40 g / 2 oz 0.002 lb/0.001 kg/0.05 oz 0.005 lb/0.002 kg / 0.1 oz 1/6000 TPD-60 60 lb / 30 kg / 960 oz 0.2 lb / 100 g / 4 oz 0.01 lb / 0.005 kg / 0.2 oz Weighing Units kg/lb/oz Front Display 0.59inch /15mm digits LCD Display with white LED back Light Rear Display 1 LCD Display with white LED back Light Platter size 13.6 x 10.4 inch / 343 x 263mm Housing Plastic housing (steel base) with stainless steel pan Interface RS232 Output standard Operation Temperature 14°F - 104°F / -10°C - + 40°C Power Battery life Keypad Dimensions (inch/mm) Net weight Input AC 100-240V, output DC 12V/500mA 6V/3.2Ah rechargeable battery Approx. 48 hours with Bluetooth and backlight of continuous use Approx. 52 hours with Bluetooth or backlight of continuous use A3 pmperomxb. r6a8nehokuerysswithout Bluetooth or backlight of continuous use 13.6 (W) x 12.7 (D) x 18.9 (H) / 345 (W) x 322.5 (D) x 478.8 (H) 10.1lb (4.6 kg) Gross weight 11.5lb (5.2 kg) Approvals NTEP: Certificate No.22-010 - 15 - TPD Series Interface Scale Operation Manual 9. DIMMENSIONS(inch/mm) - 16 - TPD Series Interface Scale Operation Manual 10.ERROR MESSAGE Error Message Description Err 4 Zero setting error Err 6 A/D value out of range --ol-fail Over range Calibration Error Solution Zero setting range exceeded due to switching on.(4%max) Make sure platform empty. Make sure platform empty and check the pan is installed proper. Check the load cell connectors. Remove the load. Re calibrate Check the calibration weight and re calibrate - 17 - TPD Series Interface Scale Operation Manual - 18 - TPD Series Interface Scale Operation ManualWPS 文字