Owner's Manual for MEAN WELL models including: MSP-200 Series 200W Single Output Medical Type, MSP-200, Series 200W Single Output Medical Type, 200W Single Output Medical Type, Output Medical Type, Medical Type
MSP-200-5 MEAN WELL - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 3 Pages, 112.67KB
DocumentDocument200W Single Output Medical Type MSP-200 series Features : User's Manual Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit 1U low profile 38mm Medical safety approved (MOOP level) Built-in remote ON-OFF control Standby 5V@0.3A GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx Built-in remote sense function No load power consumption<0.5W (Note.6) 5 years warranty SPECIFICATION ANSI/AAMI ES60601-1 IEC60601-1 TPTC004 MODEL MSP-200-3.3 MSP-200-5 MSP-200-7.5 MSP-200-12 MSP-200-15 MSP-200-24 MSP-200-36 MSP-200-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V OUTPUT RATED CURRENT 40A 35A CURRENT RANGE 0 ~ 40A 0 ~ 35A RATED POWER 132W 175W RIPPLE & NOISE (max.) Note.2 80mVp-p 90mVp-p VOLTAGE ADJ. RANGE 2.8 ~ 3.8V 4.3 ~ 5.8V VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% LINE REGULATION ±0.5% ±0.5% LOAD REGULATION ±1.5% ±1.0% SETUP, RISE TIME 1000ms, 50ms/230VAC 26.7A 16.7A 13.4A 0 ~ 26.7A 0 ~ 16.7A 0 ~ 13.4A 200.3W 200.4W 201W 100mVp-p 120mVp-p 150mVp-p 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V ±2.0% ±1.0% ±1.0% ±0.5% ±0.3% ±0.3% ±1.0% ±0.5% ±0.5% 2500ms, 50ms/115VAC at full load 8.4A 0 ~ 8.4A 201.6W 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5% 5.7A 0 ~ 5.7A 205.2W 250mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5% 4.3A 0 ~ 4.3A 206.4W 250mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5% HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.99/115VAC at full load INPUT EFFICIENCY (Typ.) 80% 84% 86% 88% 88% 88% 89% 89% AC CURRENT (Typ.) 2.2A/115VAC 1.1A/230VAC INRUSH CURRENT (Typ.) 35A/115VAC 70A/230VAC LEAKAGE CURRENT Note.7 Earth leakage current < 300A/264VAC , Touch leakage current < 100A/264VAC OVERLOAD PROTECTION OVER VOLTAGE 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover 57.6 ~ 67.2V FUNCTION OVER TEMPERATURE 5V STANDBY REMOTE CONTROL WORKING TEMP. Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.) RC+/RC- : 4 ~10V or open = power on ; 0 ~ 0.8V or short = power off -40 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS ANSI/AAMI ES60601-1, IEC60601-1, EAC TP TC 004 approved, Design refer to BS EN/EN60601-1, BS EN/EN62368-1 SAFETY & EMC (Note 4) ISOLATION LEVEL WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION Primary-Secondary: 2×MOOP, Primary-Earth: 1×MOOP I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to BS EN/EN55011 (CISPR11) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN60601-1-2, EAC TP TC 020 MTBF 1609.5K hrs min. Telcordia SR-332 (Bellcore) ; 186.2K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 199*98*38mm (L*W*H) PACKING 0.77Kg; 18pcs/14.9Kg/0.87CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. No load power consumption<0.5W when RC+ & RC- (CN100 pin1,2) 0 ~ 8V or short. 7. Touch current was measured from primary input to DC output. 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:MSP-200-SPEC 2022-09-20 200W Single Output Medical Type MSP-200 series 7 98 85.5 18 9.5 3.5 28.5 38 Mechanical Specification Case No.902E Unit:mm 197 9 3.5 3-M3 3.5 15 26 Terminal Pin No. Assignment Pin No. Assignment Pin No. Assignment 1 AC/L 4,5 DC OUTPUT -V 2 AC/N 6,7 DC OUTPUT +V 3 FG Connector Pin No. Assignment (CN100) : HRS DF11-6DP-2DS or equivalent Pin No. Assignment Mating Housing Terminal 1 RC+ 2 RC- 3 AUX HRS DF11-6DS HRS DF11-**SC 4 AUXG or equivalent or equivalent 5 +S 6 -S 8.2 9.5 9 18.5 1 2 3 4 5 6 7 LED 3.5 CN100 SVR1 4.5 57.5 6.5 13max. 28 80 4-M3 120 199 190 150.75 Block Diagram EMI I/P FILTER FG Derating Curve ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC O.T.P. PFC CONTROL AUX POWER POWER SWITCHING O.L.P. RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT PWM fosc :70KHz AUX AUXG +S +V -V -S PWM O.V.P. CONTROL REMOTE RC+ CONTROL RC- Output Derating VS Input Voltage LOAD (%) LOAD(%) 112050 100 90 80 80 60 70 60 40 50 20 40 -40 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:MSP-200-SPEC 2022-09-20 Downloaded from Arrow.com. 200W Single Output Medical Type MSP-200 series Function Description of CN100 Pin No. Function Description 1 RC+ Turns the output on and off by electrical or dry contact between pin 2 (RC-). Short: Power OFF, Open: Power ON. 2 RC- Remote control ground. 3 AUX Auxiliary voltage output, 4.75~5.25V, reference to pin 4(AUXG). The maximum load current is 0.3A. This output has the built-in oring diodes and is not controlled by the "remote ON/OFF control". 4 AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). 5 +S Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. 6 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Function Manual 1.Remote Control The PSU can be turned ON/OFF by using the "Remote ON/OFF" function Between RC-(pin2) and RC+(pin1) Output Status SW ON (Short) OFF SW OFF (Open) ON -V -V +V +V CN100 1 3 5 2 4 6 CN100 1 RC+ AUX +S 5 SW 2 RC- AUXG -S 6 2.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. LOAD -+ Fig 1.1 Downloaded from Arrow.com. -V -V +V +V CN100 1 3 5 2 4 6 -S LOAD +S (Pin6) (Pin5) -+ Sense lines should be twisted in pairs Fig 2.1 CN100 1 RC+ AUX +S 5 2 RC- AUXG -S 6 File Name:MSP-200-SPEC 2022-09-20