Instruction Manual for SIEMENS models including: FPI-UK11, FPI-UK11 Upgrade Kit, Upgrade Kit

FPI-UK11r4

KRand

Click here to download

Siemens FPI-UK11 Upgrade Kit, Installation Instructions - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications


File Info : application/pdf, 4 Pages, 636.80KB

PDF preview unavailable. Download the PDF instead.

?tmstv=1676769082
Installation Instructions
Model FPI-UK11 Upgrade Kit

Siemens Industry, Inc. Building Technologies Division Florham Park, NJ
P/N 315-096065-5

Siemens Building Technologies, Ltd. Fire Safety & Security Products 2 Kenview Boulevard Brampton, Ontario L6T 5E4 Canada

firealarmresources.com

Installation
Disconnect the AC adapter before installation.
To upgrade the Model FPI-32 Programmer/Tester using the Model FPI-UK11 Upgrade Kit, follow the steps listed below:
1. Remove the 9 screws around the sides of the FPI-32 and set them to one side. Remove the FPI-32 cover.
2. Remove one of the batteries. 3. Remove the black inner cover inside the detector base by
removing the 2 screws marked A, as shown in Figure 1. Set the screws and the cover to one side. 4. Disconnect the wires from screw terminals 5 (red) and 6 (black). 5. Remove the black base by removing the 2 screws marked B, as shown in Figure 1. Discard the black base. 6. Mount the white base provided in the FPI-UK11 Upgrade Kit using the 2 screws removed in Step 5. 7. Connect the black wires to screw terminal 6 and the red wires to screw terminal 5. 8. Place the black inner cover that was removed in Step 3 back inside the base. Line up the holes and use the 2 screws set aside in Step 3 to secure the black inner cover in place. 9. Insert the new IC2. a. Remove IC2 from its socket. Do this by lifting one end of
the IC slightly, then the other end. Continue this process until the IC comes free. Use a short, thin blade screwdriver for best results. Refer to Figure 2 for the location of IC2. b. Discard the old IC. c. Insert the FPI-32 Rev. 3.2 IC into the socket for IC2. Locate the notch in the end of the IC to face the batteries as indicated by the silkscreen outline on the PC board (See Figure 2). Be sure that all pins go into the proper socket holes. Press down firmly to seat the IC properly.
firealarmresources.com

Figure 1 Replacing the Base in the FPI-32 ProgrammerTester
Figure 2 Replacing IC2 in the FPI-32 ProgrammerTester
firealarmresources.com

10. Replace the battery removed in Step 2. 11. Replace the FPI-32 cover, removed in Step 1, back on the
chassis and fasten it securely with the 9 screws. 12. Place the supplied FPI-32 Programmer/Tester Operating
Instructions front cover label over the existing label. 13. Remove the TRI-MSI connections label (adjacent to the TRI/MSI
connection plug) and replace with the supplied TRI/MSI/CZM/I CP label. 14. (Optional) Install base detector lock according to Installation Instructions P/N 315-080240. This locks the adapter in place with the base. 15. Insert the DB-ADPT adapter into the base and rotate it until it locks in place.
NEW FPI-32 Program and Menu Modes
Significant changes have been made to the FPI-32 Program and Menu modes. Please refer to the FPI-32 Programmer/Tester Operations Manual, P/N 315-090077, for further information.
P/N 315-096065-5
firealarmresources.com



References