GT Designer2 Version 2 Basic Operation/Data Transfer Manual (For GOT1000 Series)
SAFETY PRECAUTIONS
WARNING: Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
CAUTION: Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Note that the caution level may lead to a serious accident according to the circumstances. Always follow the instructions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and always forward it to the end user.
DESIGN PRECAUTIONS
WARNING
- Failures of the GOT, communication unit, or cable may keep outputs ON or OFF. Failures of a touch panel may cause malfunction of input objects like touch switches. An external monitoring circuit should be provided to check for output signals that could lead to a serious accident. Failure to do so can cause an accident due to false output or malfunction.
- If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended, and the GOT becomes inoperative. For bus connection: The CPU becomes faulty and the GOT becomes inoperative. For other than bus connection: The GOT becomes inoperative. A system using the GOT should be configured to perform any significant operation to the system using devices other than the GOT, assuming that a GOT communication fault will occur. Failure to do so can cause an accident due to false output or malfunction.
- Do not use the GOT as a warning device that may cause a serious accident. An independent and redundant hardware or mechanical interlock is required to configure a device that displays and outputs serious warnings. Failure to observe this instruction may result in an accident due to incorrect output or malfunction.
- Incorrect operation of touch switch(s) may lead to a serious accident if the GOT backlight goes out. When the GOT backlight goes out, the POWER LED flickers (green/orange) and the display section turns black, appearing blank, while touch switch input remains active. This may confuse an operator into thinking the GOT is in "screensaver" mode, leading them to touch the display section, potentially operating a touch switch. Note that when the backlight goes out, the POWER LED flickers (green/orange) and the monitor screen appears blank.
- The display section of the GT16 is an analog-resistive type touch panel. If you touch the display section simultaneously at 2 or more points, the switch located around the center of the touched point, if any, may operate. Do not touch the display section at 2 or more points simultaneously. Doing so may cause an accident due to incorrect output or malfunction.
- When programs or parameters of the controller (such as a PLC) that is monitored by the GOT are changed, be sure to reset the GOT or shut off the GOT's power at the same time. Failure to do so can cause an accident due to false output or malfunction.
CAUTION
- Do not bundle control and communication cables with main-circuit, power, or other wiring. Run these cables separately from such wiring and keep them at least 100mm apart. Failure to do so can cause noise leading to malfunction.
- Do not press the GOT display section with a pointed material like a pen or screwdriver. Doing so can result in damage or failure of the display section.
- When the GOT is connected to the Ethernet network, the available IP address is restricted according to the system configuration.
- When multiple GOTs are connected to the Ethernet network: Do not set the IP address (192.168.0.18) for the GOTs and the controllers in the network.
- When a single GOT is connected to the Ethernet network: Do not set the IP address (192.168.0.18) for the controllers except the GOT in the network. Doing so can cause IP address duplication. The duplication can negatively affect the communication of the device with the IP address (192.168.0.18). The operation at IP address duplication depends on the devices and the system.
- Turn on the controllers and network devices to be ready for communication before they communicate with the GOT. Failure to do so can cause a communication error on the GOT.
MOUNTING PRECAUTIONS
WARNING
- Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel. Failure to do so can cause the GOT to fail or malfunction.
- Be sure to shut off all phases of the external power supply used by the system before mounting or removing the communication unit, option unit, option function board, or multi-color display board onto/from the GOT. Failure to do so can cause the unit to fail or malfunction.
- Before mounting an optional function board or Multi-color display board, wear a static discharge wrist strap to prevent the board from being damaged by static electricity.
CAUTION
- Use the GOT in an environment that satisfies the general specifications described in the User's Manual. Failure to do so can cause electric shock, fire, malfunction, or product damage or deterioration.
- When mounting the GOT to the control panel, tighten the mounting screws within the specified torque range. Undertightening can cause the GOT to drop, short circuit, or malfunction. Overtightening can cause a drop, short circuit, or malfunction due to damage of the screws or the GOT.
- When loading the communication unit or option unit to the GOT (GT16, GT15), fit it to the extension interface of the GOT and tighten the mounting screws within the specified torque range. Undertightening can cause the GOT to drop, short circuit, or malfunction. Overtightening can cause a drop, failure, or malfunction due to damage of the screws or unit.
- When mounting the multi-color display board onto the GOT (GT15), connect it to the corresponding connector securely and tighten the mounting screws within the specified torque range. Loose tightening may cause the unit and/or GOT to malfunction due to poor contact. Overtightening may damage the screws, unit, and/or GOT, potentially causing malfunction.
- When mounting the option function board onto the GOT (GT16), connect it to the corresponding connector securely and tighten the mounting screws within the specified torque range (0.25 to 0.35 N·m) with a Phillips-head screwdriver No.1. Undertightening can cause malfunction due to poor contact. Overtightening can cause malfunction due to screw or unit damage.
- When mounting an optional function board onto the GOT (GT15), fully connect it to the connector until you hear a click.
- When mounting an optional function board onto the GOT (GT11), fully connect it to the connector.
- When inserting a CF card into the GOT (GT16, GT15, GT11), push it into the CF card interface of GOT until the CF card eject button pops out. Failure to do so may cause a malfunction due to poor contact.
- When inserting/removing a CF card into/from the GOT (GT16, GT15, GT11), turn the CF card access switch OFF in advance. Failure to do so may corrupt data within the CF card.
- When removing a CF card from the GOT, make sure to support the CF card by hand, as it may pop out. Failure to do so may cause the CF card to drop from the GOT and break.
- When installing a USB memory to the GOT (GT16), make sure to install the USB memory firmly into the USB interface. Failure to do so may cause a malfunction due to poor contact.
- Before removing the USB memory from the GOT (GT16), operate the utility screen for removal. After the successful completion dialog box is displayed, remove the memory by hand carefully. Failure to do so may cause the USB memory to drop, resulting in damage or failure of the memory.
- For closing the USB environmental protection cover, fix the cover by pushing the mark on the latch firmly to comply with the protective structure.
- Remove the protective film of the GOT. If the user continues using the GOT with the protective film, the film may not be removed.
- Operate and store the GOT in environments without direct sunlight, high temperature, dust, humidity, and vibrations.
- Use the protective cover for oil when the GOTs (GT16, GT15, GT11, and GT10) are used in environments with oil or chemicals. Failure to do so can cause failures or malfunction due to the infiltration of oil or chemicals.
WIRING PRECAUTIONS
WARNING
- Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in electric shock, product damage, or malfunctions.
CAUTION
- Please make sure to ground the FG terminal, LG terminal, and protective ground terminal of the GOT power supply section by applying Class D Grounding (Class 3 Grounding Method) or higher, which is used exclusively for the GOT. Failure to do so may cause electric shock or malfunction.
- Be sure to tighten any unused terminal screws with a torque of 0.5 to 0.8 N·m. Failure to do so may cause a short circuit due to contact with a solderless terminal.
- Use applicable solderless terminals and tighten them with the specified torque. If any solderless spade terminal is used, it may be disconnected when the terminal screw comes loose, resulting in failure.
- Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product. Failure to do so can cause fire or failure.
- Tighten the terminal screws of the GOT power supply section within the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to damage of the screws or the GOT.
- Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT. Failure to do so can cause fire, failure, or malfunction.
- The module has an ingress prevention label on its top to prevent foreign matter, such as wire offcuts, from entering the module during wiring. Do not peel this label during wiring. Before starting system operation, be sure to peel this label because of heat dissipation.
- Plug the bus connection cable by inserting it into the connector of the connected unit until it "clicks". After plugging, check that it has been inserted snugly. Failure to do so can cause a malfunction due to a contact fault.
- Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws within the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to damage of the screws or unit.
- Plug the QnA/ACPU/Motion controller (A series) bus connection cable by inserting it into the connector of the connected unit until it "clicks". After plugging, check that it has been inserted snugly. Failure to do so can cause a malfunction due to a contact fault.
TEST OPERATION PRECAUTIONS
WARNING
- Before performing test operations of user-created monitor screens (such as turning ON or OFF bit devices, changing word device current values, changing timer or counter settings/current values, and changing buffer memory current values), read through the manual carefully and familiarize yourself with the operation method. During test operation, never change the data of devices used for significant system operations. False output or malfunction can cause an accident.
STARTUP/MAINTENANCE PRECAUTIONS
WARNING
- When power is ON, do not touch the terminals. Doing so can cause electric shock or malfunction.
- Correctly connect the battery connector. Do not charge, disassemble, heat, short-circuit, solder, or throw the battery into fire. Doing so will cause the battery to generate heat, explode, or ignite, resulting in injury and fire.
- Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Failure to switch off the power in all phases can cause unit failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to damage of the screws or unit.
CAUTION
- Do not disassemble or modify the unit. Doing so can cause failure, malfunction, injury, or fire.
- Do not touch the conductive and electronic parts of the unit directly. Doing so can cause unit malfunction or failure.
- The cables connected to the unit must be run in ducts or clamped. Failure to do so can cause the unit or cable to be damaged due to dangling, motion, or accidental pulling of the cables, or can cause a malfunction due to a cable connection fault.
- When unplugging a cable connected to the unit, do not hold and pull the cable portion. Doing so can cause the unit or cable to be damaged, or can cause a malfunction due to a cable connection fault.
- Do not drop or apply strong impact to the unit. Doing so may damage the unit.
- Do not drop or give an impact to the battery mounted to the unit. Doing so may damage the battery, causing battery fluid to leak inside. If the battery is dropped or impacted, dispose of it without using.
- Before touching the unit, always touch grounded metal, etc., to discharge static electricity from your body. Failure to do so can cause the unit to fail or malfunction.
- Replace the battery with GT15-BAT (GT16, GT15) or GT11-50BAT (GT11, GT10) by Mitsubishi Electric Co. only. Use of another battery may present a risk of fire or explosion.
- Dispose of used batteries promptly. Keep away from children. Do not disassemble and do not dispose of in fire.
TOUCH PANEL PRECAUTIONS
CAUTION
- For analog-resistive film type touch panels, adjustment is normally not required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration.
- When any difference between a touched position and the object position occurs, other objects may be activated. This may cause unexpected operation due to incorrect output or malfunction.
BACKLIGHT REPLACEMENT PRECAUTIONS
WARNING
- Be sure to shut off all phases of the external power supply of the GOT (and the PLC CPU in the case of a bus topology) and remove the GOT from the control panel before replacing the backlight (when using the GOT with the backlight replaceable by the user). Failure to do so can cause electric shock. Replacing a backlight without removing the GOT from the control panel can cause the backlight or control panel to drop, resulting in injury.
CAUTION
- Wear gloves for backlight replacement when using the GOT with the backlight replaceable by the user. Failure to do so can cause injury.
- Before replacing a backlight, allow 5 minutes or more after turning off the GOT when using the GOT with the backlight replaceable by the user. Failure to do so can cause a burn from the heat of the backlight.
DISPOSAL PRECAUTIONS
CAUTION
- When disposing of the product, handle it as industrial waste. When disposing of batteries, separate them from other wastes according to local regulations. (For details of the battery directive in EU member states, refer to the User's Manual of the GOT being used.)
TRANSPORTATION PRECAUTIONS
CAUTION
- When transporting lithium batteries, make sure to treat them based on transport regulations. (For details on models subject to restrictions, refer to the User's Manual for the GOT you are using.)
- Make sure to transport the GOT main unit and/or relevant unit(s) in a manner that they will not be exposed to impacts exceeding the impact resistance described in the general specifications of the User's Manual, as they are precision devices. Failure to do so may cause the unit to fail.
- Check if the unit operates correctly after transportation.
Cautions for using this software
- Required PC memory: The processing may be terminated by Windows on a personal computer with less than 64MB of main memory. Ensure at least 64MB is secured.
- Free capacity of hard disk (virtual memory): At least 100MB of free capacity of virtual memory should be secured on the hard disk to run this software. Processing may be terminated by Windows if 100MB or more of free space cannot be secured on the hard disk while running GT Designer2. Secure enough free capacity of virtual memory on the hard disk to run the software. When enough free capacity cannot be secured, make sure to save projects frequently.
- Error messages displayed while starting and editing: If the message "Operation will be terminated because of insufficient memory. Would you like to stop?" appears, close other running applications or reboot Windows to secure at least 100MB of free hard disk space.
- GT Designer2 and GOT display:
- (a) Cautions for displaying straight line other than full line (dotted line, for example) in Bold: When a straight line other than a full line is drawn in bold, the line may not be displayed with its actual line width on a personal computer. However, it will be displayed correctly on the GOT. This phenomenon does not indicate a data problem.
- (b) Display of end points of straight line/line freeform/polygon: As shown below, the end points of straight line/line freeform/polygon are displayed differently between GT Designer2 and GOT. [Diagram description: A visual comparison showing how end points of lines and polygons appear differently in GT Designer2 software versus on the GOT display.]
- (c) Start position for filling patterns: Some filling patterns may be displayed differently. For example, the start position may differ between GT Designer2 and GOT.
- (d) Drawing of different type lines: The length of the dots varies in different dotted lines (e.g., chain lines).
- (e) Display of object:
- The display position of memory data display in the graph function differs between GT Designer2 and GOT.
- Even if the display-start-line of a comment has been set, the comment will be displayed from the first line on GT Designer2.
- (f) Display magnification: When display magnification is changed, connected lines or figures may be separated, or the filled paint may go out of the figure's outline. However, if they are displayed correctly on the preview screen, they will appear correctly on the GOT as well. [Diagram description: An example showing how paint might extend beyond an outline at 200% magnification, but is correct at 100%.]
- Restrictions when the color setting is changed to fewer colors in the system environment (256 colors, 2 colors):
- The color palette for setting color will change according to the new settings.
- The colors on the drawing screen will remain the same as prior to the change. If the color setting for a [red] rectangle figure is changed to 2 colors (B/W), the [red] color will remain.
- The colors of image data (BMP format file) will be reduced when the project is stored, the screen is closed, and that image data is double-clicked.
- Object function and device type: The object (bit lamp or word lamp) for which bit device setting and word device setting are separated cannot be converted between bit device and word device.
- When device type is changed: Confirm the device type when the set bit device is changed from bit device to word device. The device flag may be represented as "??", depending on the settings. (Example: D0.b0 D0 D0.b5 ?? )
- OS setting: Set the font size as "Small Font" when setting the OS (Windows) screen. The GT Designer2 dialog box cannot be displayed correctly if the font size is set as "Large font".
- When the toolbar icon appears in smaller size after startup of GT Designer2: The toolbar icon may appear in a smaller size right after GT Designer2 is started up. To display the icon correctly, initialize it as instructed below. (Click on [Project] [References] from the menu, and select the toolbar tab. Click the Reset All button in that tab.)
- When using GT Designer2 in a PC with an OS other than the applicable language version: The text may not be displayed correctly depending on the OS versions; some versions include fonts incompatible with GT Designer2 or GOT.
- When using Microsoft Narrator: GT Designer2 cannot be used with Microsoft Narrator. When using GT Designer2, do not use Microsoft Narrator.
REVISIONS
The manual number is given on the bottom left of the back cover.
Print Date | Manual Number | Revision |
---|---|---|
Oct., 2004 | SH (NA) -080529ENG-A | First Printing |
Mar., 2005 | SH (NA) -080529ENG-B | Partial corrections, Partial additions |
Apr.,2005 | SH (NA) -080529ENG-C | Partial additions |
Oct., 2005 | SH (NA) -080529ENG-D | Partial corrections, Partial additions |
Janu., 2006 | SH(NA)-080529ENG-E | Partial corrections, Partial additions |
Jun., 2006 | SH(NA)-080529ENG-F | Partial corrections, Partial additions |
Nov., 2006 | SH(NA)-080529ENG-G | Partial corrections, Partial additions |
Dec., 2006 | SH(NA)-080529ENG-H | Partial corrections |
Feb., 2007 | SH(NA)-080529ENG-I | Partial corrections SAFETY PRECAUTIONS changed, Sections 5.4.3, 6.1.2, 6.1.3, 7.7.5, 8.1.1, 8.1.2, 8.2.6, 11.1.5, 12.1.3 |
May., 2007 | SH (NA) -080529ENG-J | Partial corrections |
Aug., 2007 | SH (NA) -080529ENG-K | Partial corrections |
Dec., 2007 | SH (NA) -080529ENG-L | Partial corrections |
Feb., 2008 | SH (NA) -080529ENG-M | Partial corrections, Additions |
Jun., 2008 | SH (NA) -080529ENG-N | Partial corrections |
Oct., 2008 | SH (NA) -080529ENG-O | Partial corrections, Partial additions |
Dec., 2008 | SH (NA) -080529ENG-P | Partial corrections, Partial additions |
Mar.,2009 | SH (NA) -080529ENG-Q | Partial corrections, Partial additions |
Oct., 2010 | SH (NA) -080529ENG-R | Partial corrections |
Sep., 2012 | SH (NA) -080529ENG-S | Partial corrections |
Dec., 2015 | SH (NA) -080529ENG-T | Partial corrections |
Japanese Manual Version SH-080508-AE
This manual confers no industrial property rights or any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual. © 2004 MITSUBISHI ELECTRIC CORPORATION
INTRODUCTION
Thank you for choosing Mitsubishi Graphic Operation Terminal (Mitsubishi GOT). Read this manual and make sure you understand the functions and performance of the GOT thoroughly in advance to ensure correct use.
CONTENTS
This document outlines the structure and content of the manual, covering sections from Cautions for using this software to Appendices and Index. Key sections include:
- Overview of GOT and GT Designer2
- Installation and Uninstallation procedures
- How to use Online Manual and Help features
- Creating Project Data (Screens)
- Screen Configuration of GT Designer2
- Screen Configuration of GOT
- Creating and Editing Screens (Project Data)
- Transferring Data
- Printing Project/File Output
- Using Library functions
- Drawing and Editing features
- Useful Functions
- Appendices (Shortcut Keys, Q&A, Data Conversion, etc.)
- Index
Function Quick Reference
This section provides a quick reference for various functions within GT Designer2, linking to relevant pages for detailed explanations.
Edit Operation
Function | Description | Page |
---|---|---|
Preview | Checks the GOT screen image. | 7-51 |
Align | Aligns objects or images. | 11-42 |
Property sheet Guidelines | Displays lines to align figures and objects when arranging a placed figure or object. | 11-45 |
Replace colors | Changes the color(s) of the objects and figures arranged on plural screens at the same time. | 12-12 |
Replace shapes | Changes the switch/lamp figures at the same time. | 12-12 |
Replace devices | Changes the preset devices at the same time. | 12-12 |
Replace CH No. | Batch changes the channel numbers. | 12-12 |
Data View | Select overlapping images or objects. | 12-16 |
Device list | Displays the set device in a list. | 12-17 |
Text list | Displays the direct input texts in a list. | 12-19 |
Multiple language input | Input characters or comments in other languages. | 12-26 |
Import BMP/JPEG/DXF file | Imports BMP/JPEG/DXF files. | 11-24 |
IGES data read | Reads IGES data. | 11-34 |
Import Project | Utilizes other project data. | 12-36 |
Change object name | Changes an object name. | 7-38 |
Object Functions
[Diagram description: A table listing various object types like Lamps, Switches, Digit/font displays, Alarms, Parts, Graphs, and Triggers, with brief descriptions of their functions and corresponding page numbers in the manual.]
- 1 Lamp/Switch: Covers lamp displays (color changing based on device value), bit switches (ON/OFF device), data set switches (changing bit device values), special function switches (Go to screen, change station, key code), and data change switches.
- 2 Digit/font display: Includes numerical display, numerical input, ASCII display, ASCII input, and clock display functions.
- 3 Alarm: Details advanced alarm displays (time message, hierarchical alarms), user alarm displays, system alarm displays, and alarm history/scrolling displays.
- 4 Parts: Covers parts display and parts movement display.
- 5 Graph/Meter: Includes panel meter, level display, trend graph, line graph, bar graph, statistics graph, circle graph, scatter graph, and historical trend graph displays.
- 6 Trigger actions: Describes status observation, write time action, logging, and device data transfer functions.
- 7 Recipe: Covers recipe function and advanced recipe function for reading/writing device data based on conditions.
- 8 External input/output: Includes hardcopy, barcode writing, remote personal operation, multimedia functions (video display/recording), MES interface, RFID, and sound output.
- 9 Others: Includes set overlay screen, test function, system monitoring, device monitor, ladder monitoring, SFC monitor, ladder editor, and backup/restore functions.
1. OVERVIEW
1.1 Overview
This manual describes the common settings, specifications of object functions, setting methods, arrangement methods, and other particulars of GT Designer 2. To divert a program example specified in this manual to an actual system, thoroughly ensure there is no problem in the control of the target system.
1.1.1 Overview
The GOT (Graphic Operation Terminal) serves as an electronic operation panel, consolidating functions like switch operation, lamp display, data display, and message display, which were conventionally implemented using control boxes. [Diagram description: An illustration showing a typical GOT unit, likely the GT15 model, highlighting its compact design.]
The screen data (project data) displayed on the GOT is created on a PC using the dedicated software, GT Designer2. In GT Designer2, users paste display frame figures called objects, such as switch figures, lamp figures, and numerical displays, to create a screen. Operation functions are then set for these objects using the device memory (bit, word) of the PLC CPU to enable GOT functions. Created project data is transferred to the GOT via USB cable, RS-232 cable, Ethernet, or memory card. [Diagram description: A system configuration showing a PC connected to a GOT via a connection cable (USB, RS-232, Ethernet) and a PLC CPU connected to the GOT, illustrating the data flow.]
1.1.2 About GOT Operation
This section explains the basic operation of the GOT when connected with a PLC CPU, using a system example. [Diagram description: A system example illustrating a PLC CPU connected to a GOT via a bus connection cable. It shows a sequence program in the PLC (e.g., MOV K123 D10) and corresponding settings on the GOT, such as touch switches linked to bit devices (M0, M1) and lamps linked to output devices (Y10). The diagram details how touching a switch on the GOT affects PLC devices and how PLC data is displayed on the GOT.]
The operation explanation details how touching a switch on the GOT turns a PLC bit device ON, which in turn controls an output (e.g., Y10). This output status is reflected on a lamp display on the GOT. Similarly, it shows how PLC data (e.g., value in D10) is displayed numerically on the GOT when a corresponding PLC device (e.g., Y10) is ON.
1.2 Software Package Configuration
1.2.1 Software
GT Works2 Version 2 and GT Designer2 Version 2 include the following software packages:
Software | Description |
---|---|
GT Designer2 | Creates screens for the GOT-1000 series and GOT-900 series. |
GT SoftGOT1000 | Enables a PC to operate as the GOT-1000 series. Requires a license key or license key FD. |
GT SoftGOT2 | Enables a PC to operate as the GOT-A900 series. Requires a license key or license key FD. Operates for about 10 minutes without a license. Contact Mitsubishi service for license details. |
GT Simulator2 | Connects to GX Simulator or PLC CPU to simulate GOT-A900 or GOT1000 series operation on a PC. |
GT Converter2 | Converts project data for GOT-800 series or Digital's package data into a GT Designer2 format file. Conversion for GOT-900 series to GOT-1000 series does not require GT Converter2. |
MES DB Connection Service | For GOT1000 series; installs MES interface function on a PC for server use. |
Document Converter | Creates data for the GOT1000 series document display function. |
Data Transfer Tool | For GOT1000, GOT900, and GOT800 series; enables downloading data from a PC and uploading data to a GOT without GT Designer2 or GOT800 series software installed. |
GT MMData Connector | Automatically transfers recorded files via Ethernet from a GOT with a multimedia unit installed to a PC, displaying them as a list. |
1.2.2 Other included data
In addition to the software, GT Works2 Version 2 and GT Designer2 Version 2 include the following data, installed into the PC:
- GT15 specific function sample data: Sample screen data for GT15 specific functions.
- Microcomputer connection sample data: Sample screen data and sample program (C language) for microcomputer connection.
- Introduction data: Screen data used for explanations in Chapter 4 of this manual. Requires writing the sequence program from the "Ladder" folder to the PLC CPU using GX Developer for actual operation.
- Online manual: PDF format online manuals related to GOT-1000 and GOT-900 series.
- Function-specific sample data for A975GOT: Sample screen data for A975GOT specific functions.
- Sample data for F940GOT/F940WGOT: Sample screen data for F940GOT/F940WGOT.
- 256-color test data: Data for checking color display with 256-color pattern settings.
Installed data is stored in folders within the MELSEC installation destination (Default: *:\Program Files\MELSEC), including example data, fonts, libraries, OS files, and manuals.
1.3 Features
1.3.1 Easy operations
- Easy to know the overall project: The Workspace displays project settings (screens, common settings) in a tree format, facilitating progress checking and screen copying.
- Easy to manage objects for each application: The Category workspace classifies overall project settings by category (type), simplifying object management.
- Easy to select parts frequently used: Objects or figures can be registered and pasted from libraries. Frequently used items can be registered as toolbar buttons. Dedicated editors are available for editing registered parts.
1.3.2 Useful functions
- Shortest setting without opening dialog box: The Property sheet displays all setting items and details for selected objects, allowing settings to be made and checked directly on the screen without opening separate dialog boxes.
- Classifying objects for each application: Touch switches, lamps, and other objects are classified by application (e.g., bit device, word device), reducing the number of setting items.
- Customizing screen: Users can customize the workspace, property sheet, and toolbars (display/non-display, position) to create a preferred drawing environment.
- Quick selection of desired screen for editing: Screens can be opened for editing by double-clicking them in the project workspace.
- Quick selection of desired part for editing: The Data View lists all objects and figures on a screen, allowing easy selection, especially for overlapped items.
- Confirming the settings in real time (View Direct): Settings made in the property sheet or dialog box are immediately reflected on the screen figures or objects, allowing smooth screen creation.
- Confirming the screen display on the GOT (Preview): The screen display on the GOT can be previewed within GT Designer2, including windowed screens.
1.4 Operating Environment
1.4.1 Operating environment
The GT Designer2 software operates on PC/AT compatible personal computers running various versions of Microsoft Windows, including Windows 98, Millennium Edition, NT Workstation 4.0, 2000 Professional, XP, Vista, and 7. Specific service pack requirements and administrator authority may apply depending on the OS version. The system requires a minimum of 1.1GB for installation and 100MB for execution. A CD-ROM drive, High Color display (16-bit or more), and a display resolution of 800x600 dots or more are necessary. Internet Explorer 5.0 or later must also be installed. Note that certain Windows features like "Compatibility mode" and "Remote desktop" are not supported.
Performance requirements vary by OS version, with recommendations for CPU speed (e.g., Pentium II 300MHz or more) and memory (e.g., 128MB or more). For Windows Vista and Windows 7, higher specifications like 800MHz+ CPU and 512MB+ RAM are recommended.
1.5 System Configuration
1.5.1 System configuration
A typical system configuration involves a PC running GT Works2 or GT Designer2, connected via a USB, RS-232, or Ethernet cable to a GOT-1000 series unit. A PLC CPU is connected to the GOT for data exchange. Memory cards (CF cards or USB memories) can be used for transferring OS and project data or storing history. A printer can be connected for output. [Diagram description: A block diagram illustrating the system setup, showing a PC, GOT, PLC CPU, and optional components like Ethernet communication units and memory cards, connected via various cables.]
1.5.2 Applicable USB cable
Specific Mitsubishi Electric USB cables are required for connecting PCs to GOT models like GT16, GT15, GT11, and GT10 series. For GT1020/GT1030, a combination of a USB cable and an RS232/USB conversion adapter is needed. [Diagram description: Diagrams showing system configurations for USB connections to different GOT models, specifying cable models like GT09-C20USB-5P and GT09-C30USB-5P.]
1.5.3 Applicable RS-232 cable
The necessary RS-232 cables for connecting PCs to GOT models are listed, including models like GT01-C30R2-9S and GT01-C30R2-6P. [Diagram description: Diagrams illustrating system configurations for RS-232 connections to various GOT models, specifying cable models.]
1.5.4 Ethernet communication unit and cable to be used
The GT16 has a built-in Ethernet interface. For GT15, the GT15-J71E71-100 Ethernet communication unit is required. Standard 100BASE-TX Ethernet cables are used for connection via a HUB. [Diagram description: A diagram showing a PC connected to a GT15 unit via an Ethernet communication unit and a HUB.]
1.5.5 Memory cards
CF cards or USB memories (for GT16 only) serve as memory cards for transferring OS and project data, or storing alarm history and recipe data. Applicable CF card models range from 16MB to 2GB (e.g., GT05-MEM-16MC, GT05-MEM-2GC). Commercially available USB memories are also supported, with a list of validated models available separately.
1.5.6 Memory boards
Memory boards are usable on GT105 and GT104 models for writing/reading standard monitor OS, communication drivers, or project data between the GOT and the memory board. The GT10-50FMB is an applicable memory board. [Diagram description: A diagram showing a memory board installed in a GT105 or GT104 unit.]
1.6 General Pre-operation Procedure
1.6.1 Outline procedure
The general pre-operation procedure for the GOT involves several steps:
- Install GT Designer2 in the PC. (Refer to Chapter 2)
- Create project data using GT Designer2. (Refer to Chapter 7 or GT Designer2 Version Screen Design Manual)
- Wire the GOT power supply and mount any necessary option boards. (Refer to relevant GOT User's Manuals)
- Transfer data (OS and project data) from the PC to the GOT. This can be done via USB, RS-232, Ethernet, or memory card. The process involves installing the Standard monitor OS and Communication driver, then downloading the project data. [Diagram description: A flowchart illustrating the data transfer process, showing options for PC-to-GOT transfer via USB/RS-232, and PC-to-CF card transfer, followed by GOT startup.]
- Connect the GOT and controller (PLC CPU) using appropriate cables (e.g., bus connection cable).
- Turn on the power supply for the GOT and the connected system.
- Start the monitor.
- End the operation.
Precautions are provided for setting the OS boot drive to "A: Standard CF Card", including potential increases in GOT startup time and handling of the CF card during booting.
2. INSTALLATION AND UNINSTALLATION
2.1 Starting the Menu Screen
To start the installation process, insert the GT Works2/GT Designer2 CD-ROM into the PC's CD drive. The menu screen should launch automatically. From this screen, users can install software or view PDF manuals. If the menu screen does not start automatically, it can be launched manually via Windows Explorer by navigating to the CD drive and executing the setup files (e.g., GTWK2-E1.exe or GTD2-E1.exe).
2.2 Installing the Software Programs
Installation precautions include closing all other applications, not connecting the GOT to the PC during installation, requiring administrator authority for certain OS versions, and avoiding installation of other software concurrently. Specific screens during installation may require user confirmation, such as selecting "This program installed correctly" or "Allow".
2.2.1 Software installing procedure
The procedure for installing GT Designer2 involves inserting Disc 1, clicking the "GT Designer 2 Installation" option, and following the on-screen prompts, including entering product ID and specifying the installation destination folder. Installation of other tools like GT SoftGOT2, GT Simulator2, and GT Converter2 follows a similar process, with specific steps for each software package.
2.2.2 Installing the manual data
To install the online manual data, insert Disc 2, click "GT Manual menu", then "GT Manual 1000 Installation" (or "GT Manual 900 Installation"). Specify the installation destination folder (default: "C:\Program Files\MELSOFT") and complete the installation. Adobe® Reader® is required to view the manuals.
2.3 Uninstalling the Software Programs
To uninstall software, access "Add or Remove Programs" via the Control Panel, select the software to be removed, and click "Add/Delete". Users must confirm the uninstallation and be cautious about deleting shared files that might affect other MELSOFT applications.
2.4 Starting the Software
Software is launched by navigating through the Start menu: [Start] > [All Programs] > [MELSOFT Application] > [GT Works2]. Specific procedures apply if GT SoftGOT2 is installed on a PC CPU module, requiring license registration.
3. HOW TO USE THE ONLINE MANUAL AND HELP
3.1 How to Use the Online Manual
The online manuals are provided as PDF data on the product CD-ROM. To view them, Adobe® Reader® must be installed. The manuals can be accessed via the "GT Manual menu" on the CD-ROM or through the Help menu within GT Designer2 after installation. The INDEX MENU screen allows selection of specific manuals.
3.2 How to Use Help
The Help menu within GT Designer2 provides access to relevant PDF manuals (Operating Manual, Reference Manual, Basic Operation/Data Transfer Manual, Screen Design Manual) and software version information. It also includes a link to the MELFANSweb homepage. PDF manuals can be viewed by selecting them from the "Index" or directly from the menu items. [Diagram description: A visual representation of the Help menu options and the procedure for viewing PDF manuals, including navigation elements like "INDEX MENU".]
3.3 How to View the Product Information
Product information, including the GT Designer2 version number, can be viewed by selecting [Help] > [About GTD2] from the menu.
4. CREATING THE PROJECT DATA (SCREENS) [INTRODUCTION]
4.1 About the GOT
The GOT (Graphic Operation Terminal) is a Human Machine Interface that functions as an electronic operation panel, consolidating various control functions typically found in control boxes. It allows for switch operations, lamp displays, data displays, and message displays on a monitor screen. [Diagram description: An image of a GOT unit, likely the GT15 model, showing its physical appearance.]
Project data, which includes the screens displayed on the GOT, is created on a PC using GT Designer2. This process involves using objects like switches, lamps, and numerical displays to design screens and setting their functions by linking them to PLC devices (bit or word). The created project data is then transferred to the GOT via USB, RS-232, Ethernet, or memory card. [Diagram description: A block diagram illustrating the workflow: PC (GT Designer2) creates project data, which is transferred to the GOT, which then communicates with a PLC CPU. Connection methods like USB, RS-232, Ethernet, and memory cards are shown.]
4.1.1 Overview
The GOT serves as an electronic operation panel, consolidating functions like switch operation, lamp display, data display, and message display, which were conventionally implemented using control boxes. [Diagram description: An illustration showing a typical GOT unit, likely the GT15 model, highlighting its compact design.]
The screen data (project data) displayed on the GOT is created on a PC using the dedicated software, GT Designer2. In GT Designer2, users paste display frame figures called objects, such as switch figures, lamp figures, and numerical displays, to create a screen. Operation functions are then set for these objects using the device memory (bit, word) of the PLC CPU to enable GOT functions. Created project data is transferred to the GOT via USB cable, RS-232 cable, Ethernet, or memory card. [Diagram description: A system configuration showing a PC connected to a GOT via a connection cable (USB, RS-232, Ethernet) and a PLC CPU connected to the GOT, illustrating the data flow.]
4.1.2 About GOT Operation
This section explains the basic operation of the GOT when connected with a PLC CPU, using a system example. [Diagram description: A system example illustrating a PLC CPU connected to a GOT via a bus connection cable. It shows a sequence program in the PLC (e.g., MOV K123 D10) and corresponding settings on the GOT, such as touch switches linked to bit devices (M0, M1) and lamps linked to output devices (Y10). The diagram details how touching a switch on the GOT affects PLC devices and how PLC data is displayed on the GOT.]
The operation explanation details how touching a switch on the GOT turns a PLC bit device ON, which in turn controls an output (e.g., Y10). This output status is reflected on a lamp display on the GOT. Similarly, it shows how PLC data (e.g., value in D10) is displayed numerically on the GOT when a corresponding PLC device (e.g., Y10) is ON.
4.2 Creating the Project Data
This section and subsequent chapters guide users through creating screens in GT Designer2 and operating them on the GOT. It is recommended for first-time users or those seeking specific operational examples.
4.2.1 Creating Screens
After preparing for screen creation, users proceed to create screens. This manual uses two Base Screens as examples. The GT Designer2 screen configuration includes a Menu bar, Toolbars, Workspace (tree view of project settings), Property sheet (displays attributes of selected items), and Data View (lists all objects and figures on a screen).
4.2.2 Settings before Screen Creation
Before creating a screen, users must specify the GOT type, PLC type, and screen name using the New Project Wizard. This involves setting system parameters, communication settings (Controller, I/F, Communication Driver), and screen switch devices. [Diagram description: A series of screenshots illustrating the steps of the New Project Wizard, including System Settings for GOT, Communication Settings, and Confirmation screens.]
Users can also create a new project without the wizard by unchecking "Show Wizard on New Project" in the Preferences dialog. Communication settings for multiple channels can be adjusted sequentially.
4.2.3 Figure drawing and text input
Screens can utilize front and back layers for placing objects. This section details drawing frame lines and inputting text. Rectangles are drawn by clicking and dragging. Double-clicking a figure opens a dialog to change line color and thickness. Text is input by clicking on the screen, which opens a Text dialog for input and font settings. Figure and text sizes can be adjusted by dragging handles. [Diagram description: Illustrations showing how to draw a rectangle, input text, and resize objects using handles.]
4.2.4 Setting the Object Function
After drawing figures and text, users set object functions. Common objects include:
- Numerical Display/Input: Displays or writes values to PLC devices (e.g., D10, D11). Settings involve selecting the type, device, shape, font, and layer. [Diagram description: Dialog boxes for Numerical Display and Numerical Input settings, showing fields for Device, Shape, Font, and Layer.]
- Lamp (Bit Lamp): Lit when a bit device turns ON. Settings include Device, Layer, Shape, and Text for ON/OFF states. Consecutive copy function allows creating multiple lamps. [Diagram description: Dialog boxes for Lamp settings, including Basic, Text tabs, and options for Copy OFF/ON.]
- Switch (Bit Switch): Turns a bit device ON or OFF when touched. Settings include Device, Action (Reset), Layer, Shape, and Text. Similar to lamps, consecutive copy is available. [Diagram description: Dialog boxes for Switch settings, showing tabs for Basic, Lamp, and Text.]
- Switch (Go To Screen Switch): Switches to a different screen upon touch. Settings include the target screen (Fixed value), Layer, Shape, and Text. Objects can be copied and pasted between screens. [Diagram description: Dialog boxes for Go To Screen Switch settings and an example of copying a switch from Base Screen 1 to Base Screen 2.]
- Alarm List (System Alarm): Displays GOT errors or system alarms. [Diagram description: An illustration showing the placement of an Alarm List object on a screen.]
- Alarm List (User Alarm): Displays user-registered comments when a bit device turns ON. Requires pre-registering comments. [Diagram description: Illustrations showing comment registration and the placement of a User Alarm List object.]
4.2.5 Setting the connection target
For bus connections, it's necessary to set the GOT's standard I/F (CH No./IF/Driver) and extended I/F (CH No./IF/Driver/Stage No./Slot No.). This is done via the [Common Settings] > [System Environment] > [Communication Settings] menu. [Diagram description: Screenshots of the System Environment and Communication Settings dialogs, showing fields for Controller, I/F, Communication Driver, Stage No., and Slot No.]
4.2.6 Saving the created project data
Created project data is saved using the [Project] > [Save As...] menu, where users specify the storage location and file name.
4.2.7 Previewing the created project data
The screen display on the GOT can be previewed within GT Designer2 using the [View] > [Preview] menu, which opens the Screen Preview window.
4.3 Executing Monitor on the GOT
4.3.1 Transferring project data from PC to GOT
This section details transferring project data from a PC to the GOT. It covers connecting the PC and GOT (USB cable recommended for speed, RS-232 also supported) and installing the Standard monitor OS and Communication driver. OS installation clears existing project data, so backup is advised. The process involves selecting communication settings, then choosing the OS and driver to install via the "OS Install GOT" tab. After OS installation, project data is downloaded using the "Project Download GOT" tab. [Diagram description: A flowchart illustrating the process of transferring project data, including OS installation and project download steps.]
4.3.2 Connecting with the PLC CPU
After transferring data to the GOT, it must be connected to the PLC CPU. This typically involves mounting a communication unit (e.g., bus connection unit) to the GOT and connecting them with a bus connection cable. Power must be OFF during mounting and connection. [Diagram description: Diagrams showing the physical connection of a bus connection unit to a GOT and the connection between the GOT and a PLC CPU using a bus connection cable.]
The manual also details the sequence program used in examples and the operation image on the GOT, showing how PLC device status affects GOT displays like lamps and numerical values, and how touch switches on the GOT control PLC devices.
4.3.3 Uploading
To back up or correct project data on the GOT, it can be uploaded to the PC. This is done via the [Communication] > [To/From GOT] menu, selecting the "Project Upload Computer" tab, and clicking the "Upload" button.
5. SCREEN CONFIGURATION OF GT Designer2
5.1 Screen Configuration and Various Tools
The GT Designer2 interface is organized into several key components:
- Title bar: Displays the application name and current project.
- Menu bar: Contains commands for file management, editing, viewing, screen operations, common settings, figures, objects, tools, communication, window management, and help.
- Toolbars: Provide quick access to frequently used functions (e.g., Main, View, Figure, Object, Edit, Align, Draw, Communication, Report, My Favorites, Comment, Coordinate/Size). Users can customize which toolbars are displayed and their layout.
- Workspace: Displays project settings (screens, common settings) in a tree structure, allowing easy navigation, copying, and management of project elements. It can be configured to show project screens, common settings, or library data.
- Property sheet: Shows and allows editing of attributes for selected screens, objects, or figures.
- Data View: Lists all objects and figures on the current screen, useful for selecting overlapped items.
- Library: Displays registered objects and figures that can be pasted onto screens.
- Status Bar: Displays information about the current operation or cursor position.
- Parts Image List: Shows parts used in the part display function.
- Dialog box: Used for detailed settings of objects and functions, featuring tabs, radio buttons, list boxes, checkboxes, and command buttons.
[Diagram description: A visual overview of the GT Designer2 interface, highlighting the Title bar, Menu bar, Toolbars, Workspace, Property sheet, Data View, and Library.]
5.2 Menu Configuration
The menu bar is organized into logical categories:
- Project: File management (New, Open, Save), preference settings, printing.
- Edit: Cut, Copy, Paste, Undo/Redo, Grouping, Flipping, Rotating figures and objects.
- View: Controls display of toolbars, workspace, property sheet, layers, and screen preview.
- Screen: Manages screens (New, Open, Close, Size).
- Common: Sets project-wide common settings, objects, parts, and comments.
- Figure: Tools for drawing various shapes and importing image/vector data.
- Object: Functions for placing and configuring interactive elements like lamps, switches, displays, and alarms.
- Tools: Utilities for device lists, error checking, and data views.
- Communication: Manages data transfer to/from the GOT, memory card operations, and communication settings.
- Window: Arranges multiple open screens (tiling).
- Help: Access to manuals, software version, and online resources.
5.3 Types of toolbars
GT Designer2 offers various toolbars that can be displayed, hidden, and customized:
- Main: Common file and editing operations (New, Open, Save, Cut, Copy, Paste, Undo, Redo, Preview).
- View: Controls screen display settings like Snap, Zoom, Grid, and Layer visibility.
- Figure: Tools for drawing basic shapes (Line, Rectangle, Circle, Polygon), text, and importing image/vector files (BMP, JPEG, DXF, IGES).
- Object: Provides quick access to place various HMI objects like Switches, Lamps, Displays, Alarms, Graphs, and Triggers.
- Edit: Functions for manipulating objects and figures, such as Bring to Front, Send to Back, Group/Ungroup, and Align.
- Align: Tools for aligning selected objects horizontally or vertically.
- Draw: Settings for line style, width, color, fill patterns, and text properties.
- Communication: Tools for data transfer (To/From GOT, To Memory Card) and communication configuration.
- Report: Tools for creating and printing reports.
- My Favorites: User-defined toolbar for frequently used functions.
- Comment: Tools for managing text comments associated with objects.
- Coordinate/Size: Displays and allows editing of the X, Y coordinates, Width, and Height of selected items.
Users can customize toolbars by adding/deleting toolbars and icons, changing icon order, and adding partitions via the Preferences dialog.
5.4 Customizing Screen Configuration and Toolbars
Users can customize the GT Designer2 environment for improved operation. This includes displaying/hiding tools (toolbars, workspace, property sheet, etc.), changing the size and position of windows, and customizing toolbar icons. The software remembers these customized settings for future sessions. [Diagram description: Illustrations showing how to resize and reposition windows like the Workspace, and how to customize toolbars by adding/removing icons and partitions.]
6. SCREEN CONFIGURATION OF GOT
6.1 Base Screen, Window Screen and Report Screen Types
The GOT supports different screen types:
- Base Screen: The main screen that appears when the GOT starts or when switching from a window screen.
- Window Screen: A screen that can be displayed over a base screen or another window screen, often used for pop-up menus or detailed information.
- Report Screen: Used for displaying data in a tabular or report format.
6.2 Screen laying
This section likely covers how screens are laid out and organized within the GOT's memory and display structure.
7. CREATING AND EDITING THE SCREEN (PROJECT DATA)
7.1 Selecting Project at the Start of GT Designer2
When GT Designer2 starts, users can create a new project or open an existing one.
7.2 Creating a New Project
A new project is created via the "New Project Wizard" or by directly selecting [Project] > [New]. The wizard guides users through setting up the GOT type, communication parameters, and initial screen properties.
7.3 Opening/Closing the Project Data
Existing project data can be opened using [Project] > [Open...] and closed via the project menu or by closing the main application window.
7.4 Setting the project title
The project title is set within the project properties, typically during creation or via the project settings.
7.5 Creating a New Screen
New screens are created using the [Screen] > [New] menu or by right-clicking in the workspace and selecting "New". The Screen Property dialog allows naming the screen and setting its attributes.
7.6 Opening/Closing Screen
Individual screens within a project can be opened or closed. Double-clicking a screen in the workspace opens it for editing. The "Previous/Next Screen" and "UnOpened Screens" functions facilitate navigation between screens.
7.7 Basic Operations of Drawing Screen (Editor)
The drawing screen (editor) provides tools for creating screen elements. This includes object placement, figure drawing, text input, layer switching (front/back), dialog box operations, and workspace management. [Diagram description: Visuals showing the drawing editor interface, including toolbars, workspace, and property sheet, with explanations of basic operations like object placement and layer switching.]
7.8 Operating multiple screens
Multiple screens can be managed and viewed simultaneously using functions like cascading or tiling, accessible via the "Window" menu.
7.9 Changing Screen Property
Screen properties, such as name, size, and background, can be modified through the Screen Property dialog.
7.10 Redisplaying the Screen
Screens can be refreshed or redisplayed if needed.
7.11 Displaying the Frame
Options exist for displaying or hiding frames around objects or screens.
7.12 Viewing Created Screen Image
The "Preview" function allows users to view how the created screen will appear on the GOT before transferring the data. This includes previews of base screens and windowed screens.
7.13 Copying/Deleting Screen
Screens can be duplicated using copy functions or deleted if no longer needed.
7.14 Setting Screen Switching Device
Specific devices can be assigned to control screen switching on the GOT.
7.15 Data Check
A data check function helps identify potential errors or inconsistencies in the project data before transfer.
7.16 Saving Project
Project data can be saved by overwriting the existing file or saving it under a new name.
7.17 Ending GT Designer2
The GT Designer2 application can be closed through the standard application exit procedures.
8. TRANSFERRING DATA
8.1 Data Types and Sizes Transferred to the GOT
This section details the types of data that can be transferred to the GOT and their storage requirements, including OS, project data, and resource data.
8.2 Preparation for Project Data Transfer [USB/RS-232/Ethernet]
This covers the necessary steps before transferring data, including connecting the PC to the GOT using appropriate cables (USB, RS-232, Ethernet) and configuring communication settings. It also explains the installation of the Boot OS and the main OS onto the GOT. [Diagram description: Diagrams illustrating PC-to-GOT connections via USB, RS-232, and Ethernet, along with steps for OS installation.]
8.3 Downloading Project Data [PC to GOT]
Project data created in GT Designer2 is downloaded to the GOT. This includes the option to download only changed data for efficiency.
8.4 Downloading Special Data [PC to GOT]
Procedures for downloading specific or special data types are outlined.
8.5 Verifying project data [PC : GOT]
This function checks for consistency between the project data on the PC and the data stored on the GOT.
8.6 Obtaining the Drive Information [GOT to PC]
Information about the GOT's drive status can be acquired and transferred to the PC.
8.7 Uploading Project Data [GOT to PC]
Project data stored on the GOT can be uploaded back to the PC for backup or modification.
8.8 Uploading Resource Data [GOT to PC]
Resource data, such as fonts or images, can also be uploaded from the GOT to the PC.
8.9 Transferring Data Using a Memory Card [PC to memory card and memory card to GOT]
This section details using CF cards or USB memories for data transfer, including installing OS, Boot OS, and project data onto the memory card from the PC, and then transferring it to the GOT. [Diagram description: Flowcharts illustrating data transfer procedures using memory cards.]
8.10 Transferring Data Using GT10-LDR
Procedures for data transfer using the GT10-LDR accessory are described, including preparation, connection, communication settings, OS installation, and downloading/uploading project data.
8.11 Transferring Data Using GT01-RS4-M
Similar to GT10-LDR, this section covers data transfer operations using the GT01-RS4-M interface converter.
8.12 Error Messages Displayed at Data Transfer
A list and explanations of common error messages encountered during data transfer are provided to help users troubleshoot issues.
9. PRINTING PROJECT/FILE OUTPUT
9.1 Printing method
This section details the methods for printing project data or outputting it to files. It covers setting methods and specific print items.
9.2 Printing example
Examples of printer output and file output are provided, demonstrating how to generate hard copies or digital files of the project data.
10. USING LIBRARY
10.1 What is Library?
Libraries in GT Designer2 allow users to store and reuse frequently used objects, figures, or custom components. This section explains the benefits and basic operations of using libraries.
10.2 Pasting Objects or Figures from Library
Objects and figures can be easily pasted onto screens from the library workspace or toolbars.
10.3 Creating Original Library
Users can create their own libraries by registering objects or figures, editing them, and managing library properties. Data can also be imported from or exported to external files.
11. DRAW AND EDIT
11.1 Drawing Figures
GT Designer2 offers a comprehensive set of tools for drawing various figures, including lines, rectangles, polygons, circles, arcs, and sectors. Users can customize line styles, widths, colors, and fill patterns. The software also supports importing image files (BMP, JPEG) and vector data (DXF, IGES). Text and logo text can be input and formatted. [Diagram description: Visuals demonstrating the use of drawing tools like Line, Rectangle, Circle, and Text input, along with options for fill patterns and colors.]
11.2 Editing Figure and Object
This section covers editing capabilities such as selecting figures and objects, grouping/ungrouping, flipping, rotating, adjusting vertices, aligning, resizing, and changing attributes. Functions like "Bring to Front" and "Send to Back" manage object layering. [Diagram description: Illustrations showing editing operations like grouping, aligning, and resizing objects.]
12. USEFUL FUNCTIONS
12.1 Edit Function
Useful editing functions include batch setting of multiple objects/figures on the same screen (Property sheet), managing objects by category (Category workspace), batch editing attributes across multiple screens (Batch edit), simple selection of overlapped figures (Data View), checking devices in use (Device List), and checking text in use (Text List).
12.2 Referring to Device Comment When Setting Devices
Device comments can be imported and referenced when setting devices, improving clarity and reducing errors.
12.3 Checking Project Data for Errors
A data check procedure helps identify and correct errors within the project data.
12.4 Entering Multiple Languages [Multi-language input function]
The software supports multi-language input, allowing users to input text in different languages and utilize Windows® multi-language functions.
12.5 Confirming the created data size
Users can confirm the size of the created project data and its components.
12.6 Utilizing other project data (GOT1000)
Existing project data can be imported and utilized, with specific procedures and cautions provided.
12.7 Starting the GOT with the CF card
Instructions are provided on how to start the GOT using data stored on a CF card.
12.8 Verifying Project Data to Project Data File
This function verifies the project data against a project data file.
APPENDIX
The appendices provide supplementary information:
- App1. List of Shortcut Keys: A comprehensive list of keyboard shortcuts for efficient operation.
- App2. Q&A of GT Designer2 Operation: Frequently asked questions and their answers regarding GT Designer2 usage.
- App3. Utilizing the Existing Data: Guidance on using existing data, including differences between GOT series functions and conversion precautions.
- App4. Precautions for Project Data: Important considerations regarding opening, uploading, downloading, and copying project data.
- App5. List of Functions Added by GT Designer2 Version Upgrade: Details on new features introduced in different versions of GT Designer2.
INDEX
An index is provided for quick lookup of specific topics within the manual.