User Guide for BOGEN models including: PS240-G2, PS120-G2, PS240-G2 PS120-G2 Platinum Series Public Address Amplifiers, PS240-G2 PS120-G2, Platinum Series Public Address Amplifiers, Public Address Amplifiers, Address Amplifiers, Amplifiers
10 gen 2025 — WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Avertissement: pour réduire le risque d'incendie ou ...
File Info : application/pdf, 15 Pages, 1.53MB
DocumentDocumentPlatinum Series Public Address Amplifiers PS240-G2, PS120-G2 Installation and Use Guide Specifications are subject to change. © Copyright 2022, Bogen Communications LLC 740-00197D 241126 WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Avertissement: pour réduire le risque d'incendie ou de choc électrique, ne pas exposer cet appareil sous la pluie et l'humidité. The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on apparatus. L'appareil ne doit pas être exposé aux écoulements ou aux éclaboussures et aucun objet ne contenant de liquide, tel qu'un vase, ne doit être placé sur l'objet. The mains plug is used as disconnect device. The mains plug of apparatus should not be obstructed OR should be easily accessed during intended use. To completely disconnect the power input, the mains plug of apparatus shall be disconnected from the mains. La prise du secteur est utilisé pour déconnecter le système. La prise du secteur ne doit pas être obstruée ou doit être facilement accessible pendant son utilisation. Pour être complètement déconnecté de l'alimentation d'entrée, la prise doit être débranchée du secteur. CAUTION: DO NOT INSTALL OR PLACE THIS UNIT IN A BOOK CASE, BUILT-IN CABINET, OR IN ANOTHER CONFINED SPACE. ENSURE THAT THE UNIT IS WELL VENTILATED TO PREVENT THE RISK OF SHOCK OR FIRE HAZARD DUE TO OVER HEATING. ENSURE THAT CURTAINS AND ANY OTHER MATERIALS DO NOT OBSTRUCT THE VENTILATION VENTS. Always comply with the following basic safety precautions when installing and using the unit: 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. DO NOT use this apparatus near water. 6. Clean only with dry cloth. 7. DO NOT block any ventilation openings. Install in accordance with the manufacturer's instructions. 8. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. DO NOT defeat the safety purpose of the polarized or groundingtype plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade, or the third prong, areprovided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on and/or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories which are specified by the manufacturer. 12. Unplug this apparatus during lightning storms or when unused for long periods of time. 13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE ANY FRONT/BACK COVERS OR PANELS. NO USER-SERVICEABLE PARTS ARE NSIDE. REFER ANY SERVICING TO QUALIFIED PERSONNEL. The lightning flash with arrowhead sumbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within a unilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions. WARNING: The apparatus shall be connected to a mains socket outlet with a protective earthing connection. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus. Where the mains plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable. Minimum distances 10cm around the apparatus for sufficient ventilation. - 10cm distance minimale autour de l'appareil pour une aération suffisante The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, curtains, etc. - il convient que l'aération ne soit pas gênée par 'obstruction des ouvertures d'aéra No naked flame sources, such as lighted candles, should be placed on the apparatus. - il convient de ne pas placer sur l'appareil de sources de flammes nues, telles que des bougies allumées This equipment is not suitable for use in locations where children are likely to be present. Equipment is intended for use only in a restricted access area. The use of apparatus in moderate climates. - si l'appareil est destiné à être utilisé sous un climat tempéré. 2 Introduction The Bogen Platinum Series Public Address Amplifier offers powerful features rarely found in other commercial amplifiers--such as a 5-band parametric EQ--without the need for add-on modules, delivering outstanding value for a wide variety of installed sound applications, such as retail, restaurants, hospitality, corporate meeting rooms, educational facilities, houses of worship, and many more. The Platinum Series model lineup includes the PS120 (120W) and PS240 (240W), each manufactured with proven Bogen quality and reliability and backed by an industryleading five (5) year warranty. Unlike typical amplifier lines, the professional sound contractor need not purchase a higher-powered amplifier just to get more extensive features or flexibility. Each of the Platinum Series amplifier models incorporates the exact same set of features. In addition to its extensive input flexibility, the Platinum Series amplifiers offer a combination of features rarely found in any other commercial amplifier. Features · 4 dedicated microphone inputs (XLR connectors MIC 1-4) with selectable phantom power · Input muting with individual selection available on all inputs · 1 selectable MIC 5/TEL input · Adjustable automatic level control on TEL input · 1 selectable MIC 6/AUX 1 input · AUX fade back after TEL page · 1 dedicated AUX 2 input · Remote master volume control capability (using · 8-ohm/25V and 70V outputs optional GSRVC) · Standard 19" rack mountable 2RU package for all · Preamp out/Power amp in connections, serves as models an Insert for external audio processing · 5-band parametric equalizer with independent Gain, · Tape output connection, pre-master Frequency, and Q controls · Level indicator meter, and peak limiting when · True loudness contour function on AUX 1 and AUX 2 amplifier is driven toward clipping · Audio Enhancement feature for improved voice · 100VAC-240VAC, 50/60 Hz universal power supply intelligibility with adjustable level · Detachable IEC power cord · Lo-cut filter for all channels · Detachable, tamper-resistant front cover included · Lo-cut is also automatically on when 70V speaker connection is selected. · Listed to UL Standard EN623681:2014 for U.S. and Canada · Selectable AUX input muting during TEL paging: -60, -21, -10, and 0 dB · VOX sensitivity adjustment for TEL paging Packaging Contents (1) Platinum Series Amplifier (1) Model GSTRC: A Plexiglas front panel cover to protect control settings from tampering (1) Installation and Use Guide (1) AC power cord (1) Rubber foot kit 3 Accessories The following accessories are available for your Platinum Series Amplifier: · Model PSRPK: Rack mounting installation kit. · Model GSRVC: This remote wall mount volume control adjusts the volume of the amplifier from distances up to 1000 feet away from the amplifier. Panel Descriptions Front Panel (All Models) 2 3 4 7 8 M IC 1 4 6 M IC 2 4 6 M IC 3 4 6 M IC 4 4 6 M IC 5 / T E L 4 6 M IC 6 /AUX 1 4 6 AUX 2 4 6 0 GAIN -15 +15 100 FREQ 2 0 82 10 0 82 10 0 82 10 0 82 10 0 82 10 0 82 10 0 8 10 IN C O N T O U R OUT 40 200 3 Q 1 10 0 -15 +15 400 190 600 3 1 10 0 -15 +15 1k 550 1.8k 3 1 10 0 -15 +15 2.8k 1.6k 4k 3 1 10 0 -15 +15 7k EQ MASTER 4 6 3.3k 16k BYPASS 2 8 3 1 10 0 10 IN E N H A N C E OUT FA U LT LIMIT -3dB -6dB -12dB -24dB ON 1 5 6 9 10 1. MIC 1 to 4: Individual level controls for dedicated microphone inputs. 2. MIC 5/TEL: Individual level control for MIC 5 or TEL input depending on input mode selected. 3. MIC 6/AUX 1: Individual level control for MIC 6 or AUX 1 input depending on input mode selected. 4. AUX 2: Individual level control for dedicated AUX 2 input. 5. CONTOUR: Enables or disables loudness equalization. Affects only AUX 2 and MIC 6/AUX 1 if set in AUX mode. 6. Equalizer: 5-band parametric EQ with gain, frequency, and Q controls. 7. Equalizer/Bypass Selector Switch: Enables or bypasses the 5-band parametric EQ. 8. MASTER: Master output level control. 9. ENHANCE: Enables or disables the Audio Enhancement effect. Affects all input signals. 10. LEDs: Power on, output power level meter, and amplifier fault status indicators. 4 Rear Panel (All Models) 2 3b 3a 3c 4 70 VOLTS 70V 8 OHMS/25V 8 OHMS/25V 7 7a 5 68 9 10 11 1 12 14 16 18 20 21 22 13 15 17 19 1. IEC Power Input: AC mains connection. 2. POWER Switch: AC power switch. 3. Amplifier Output Speaker Terminals: Pluggable screw terminals connect to speaker loads. Class 2 wiring acceptable. 3a. 70V 8 OHMS/25V: Switch to select either 8/25V or 70V speaker operation. 3b. 70 VOLTS: Pluggable screw-retained terminals for 70V speaker connection. 3c. 8 OHMS/25V: Pluggable screw-retained terminals for 8/25V speaker connection. 4. REMOTE MASTER: Pluggable screw terminals pair for connection of remote master volume control (Bogen model GSRVC). 5. MIC/AUX/TEL PRECEDENCE: Pluggable screw terminal connections that allow externally controlled muting of individual inputs. 6. VAR MUTE: Four switch-selectable levels of AUX input signal muting during TEL page (works only in the TEL input mode). 7. LO CUT FILTER: Enables or disables low frequency roll off (85 Hz) for all inputs. 7a. Red LED indicator is on when Lo-Cut or 70V speaker connection is in use. 8. AUX 1/MIC 6: Switch selects either AUX 1 or MIC 6 connection as input. 9. MIC 6: Screw terminals for balanced microphone (active only when AUX 1/MIC 6 switch is set to MIC 6). 10. MIC 5/TEL: Dual-function screw terminals for either balanced microphone or 600-ohm balanced input from telephone page port. 11. MIC 5/TEL: Switch selects either MIC 5 or TEL connections as input. 12. POWER AMP IN: RCA unbalanced direct input to power amp stage for connection to external signal processing equipment (used in conjunction with PRE OUT and LINK switch). 13. PRE OUT: RCA unbalanced output from preamp/mixer stage for connection to external signal processing equipment (used in conjunction with POWER AMP IN and LINK switch). 14. LINK: Switch that makes or breaks the internal connection between preamp/mixer stage and power amp stage when used with external signal processing equipment. 15. TAPE OUT: RCA unbalanced output, pre-EQ and master volume. (Post Lo-Cut filter, see #7). 16. AE: Variable control for adjusting the amount of Audio Enhancement effect. 5 17. ALC: Variable control adjusts amount of Automatic Level Control applied to TEL input (works only in TEL input mode). 18. VOX: Variable control adjusts TEL input signal level trigger point for automatic muting of the AUX inputs (works only in TEL input mode). 19. AUX 1: RCA unbalanced input for AUX 1 input signal (works only when AUX 1/MIC 6 switch is set to AUX 1). 20. AUX 2: RCA unbalanced input for dedicated AUX 2 input. 21. MIC 1 to 4: Balanced XLR connectors for dedicated microphone inputs. 22. PHANTOM (MIC 1 to 4): Individual switches enable or disable phantom power to each of the four dedicated microphone inputs. Input Connections Installation Note Keep input leads away from the output leads and AC power cables. Unless the driving source provides a lowimpedance output, keep the input lead under ten feet in length. Make all connections to the unit with the POWER switch in the OFF position. MIC 14 (Rear Panel: #21 and #22) MIC 1 through 4 utilize female XLR-type microphone connectors. A slide switch located above each XLR connector is used to supply phantom power for condenser microphones. MIC 5/TEL (Rear Panel: #10 and #11) The MIC 5/TEL input is designed to accept input from a microphone or from a telephone page port. A slide switch is provided to select MIC 5 or TEL input. To connect a microphone, place the MIC 5/TEL switch in the MIC position. Use two conductor shielded cable and connect the cable shield to the center GND terminal. To use the TEL input, place the MIC 5/TEL switch in the TEL position and connect the 600-ohm telephone paging source (dry signal only--no DC voltage) to the MIC 5/TEL screw terminals. AUX 1/MIC 6 (Rear Panel: #8, #9, #19) The AUX 1/MIC 6 input is designed to accept input from a microphone using terminal strip connections or from a line level auxiliary source such as a tuner or CD player using the AUX 1 RCA jack. A slide switch is used to select input type. Connect a microphone to the screw terminals labeled MIC 6 (works only when AUX 1/MIC 6 switch is in the MIC 6 position). Use two conductor shielded cable and connect the cable shield to the center GND terminal. Connect an auxiliary input source to the AUX 1 RCA jack (only works when the AUX 1/MIC 6 switch is in the AUX1 position.) 6 AUX 2 (Rear Panel: #20) The AUX 2 input uses an RCA plug and accepts input from a dedicated AUX source. Remote Volume Control (Rear Panel: #10) If remote volume control is desired, connect the Bogen accessory GSRVC Remote Volume Control to the screw terminals marked REMOTE MSTR. Wire length can be up to 1000 feet using 22-gauge wire. Connections are not polarity sensitive. Precedence Connections (Rear Panel: #11) Precedence connections allow any combination of inputs to be completely muted with a contact closure. Closing a contact across any of the precedence terminals and the PREC COM 1 terminal will mute that input. A customer-supplied normally-open SPST switch, push-to-talk switch, microphone switch, relay or telephone system contact can be used to provide the closure. Note: Activating the precedence control for AUX inputs completely mutes the input signal. The VAR MUTE control has no effect when muting inputs using precedence control. Output Connections Power Amp In and Pre Out Jacks (Rear Panel: #12, #13, #14) These jacks permit the insertion of signal processing equipment into the signal path between the preamp output and the power amp input. The LINK switch should be in the IN position for normal operation. When using external signal processing equipment, place the switch in the OUT position and connect PRE OUT to the signal processing equipment's input. Connect the POWER AMP IN to the signal processing equipment's output. Note: Ensure that the LINK switch is in the IN position when not using external signal processing equipment, otherwise there will be no output from the amplifier. Tape Out (Rear Panel: #15) The TAPE OUT jack provides a line-level output to feed a recording device. The output is not effected by the Master volume control or EQ, however, the output is affected by the microphone inputs' Lo-Cut filter. 7 Speaker Out Terminals (Rear Panel: #3a, #3b, #3c) The Speaker Out terminals provide amplified speaker-level signals intended to drive 8-ohm/25V or 70V terminations. Each output pin is driven by the output of an amplifier. Therefore, neither pin of the Speaker terminals can be connected to chassis or Earth ground. Doing so will cause the amplifier to mute the audio, remain in Protect mode, and flash the FAULT LED (see "LEDs (Front Panel: #10)" on page 12) as long as the grounded connection remains. Direct 8-ohm operation Direct 8-ohm operation consists of terminating the amplifier (without speaker transformers) with: · Two 4-ohm speakers in series · One 8-ohm speaker · Two 16-ohm or four 32-ohm speakers in parallel 70 VOLTS 8 OHMS/25V Distributed 70V/25V or Direct 8-Ohm Speaker Operation The combined total power across all speaker transformer input taps must not exceed 80% of the rated amplifier power. Also, for 70V operation, the total distributed impedance for all transformer inputs must not be less than 50 ohms. 70V Line Xfmr 25V Line Xfmr 8 70 VOLTS 70V 8 OHMS/25V 8 OHMS/25V NOTICE Speaker output at both connectors simultaneously is not supported. The speaker signal will only be available at the output connectors indicated by the 70V | 8 OHMS/25V switch. 8 Operation Power Switch (Rear Panel: #2) The POWER switch applies power to the unit. An LED labeled ON, which is located on the front panel, illuminates GREEN when power is on. Individual Volume Controls (Front Panel: #1#4) Each input is controlled by an individual volume control. MIC 1 4 6 MIC 2 4 6 MIC 3 4 6 MIC 4 4 6 MIC 5/TEL MIC 6/AUX 1 4 6 4 6 AUX 2 4 6 2 82 82 82 82 82 82 0 10 0 10 0 10 0 10 0 10 0 10 0 10 Master Volume Control (Front Panel: #8) The overall volume is controlled by the MASTER volume control. 4 2 6 8 Lo-Cut Filter (Rear Panel: #7) The Lo-Cut filter on the rear panel provides low-frequency attenuation on all inputs. This helps reduce mic breath pop, wind noise, and rumble. It also reduces transformer magnetic saturation during 70V operation. Note: Lo-Cut is automatically enabled when the 70V speaker connection is selected. Contour Switch (Front Panel: #5) This switch enables or bypasses the variable loudness contour. This feature only affects the AUX inputs. This feature is designed to improve richness of sound by restoring the high and low frequencies that the ear is insensitive to at low volume levels. The effect diminishes as volume is increased. Audio Enhancement (Front Panel: #9 / Rear Panel: #16) The front panel Enhance switch enables or bypasses the Audio Enhancement feature. This feature affects all inputs when enabled. By regenerating the upper harmonics, this audio enhancement system recreates the presence and realism that is lost in the audio amplification process. This results in increased presence and clarity, increased intelli- gibility, greater perceived loudness (without using extra power), and reduced listener fatigue. The rear panel AE adjustment controls the mix of the Audio Enhancement effect with the audio signal. Counterclockwise rotation of the control minimizes the Audio Enhancement effect. Clockwise rotation of the control maximizes the Audio Enhancement effect. 0 10 IN CONTOUR OUT IN ENHANCE OUT 9 Parametric Equalizer (Front Panel: #6) A parametric equalizer offers continuous and independent control over the audio signal's frequency content, which is divided into five frequency bands on the Platinum Series amplifiers. These controls are: GAIN: The gain (boost/cut) for each frequency band. The gain range for the Platinum Series is -15 dB to ±15 dB as indicated on the GAIN row of controls on the Platinum Series front panel. FREQ (Frequency): The frequency region where the gain boost/cut is desired. The five filter frequency ranges are indicated in the FREQ row of controls on the Platinum Series front panel. Each frequency band is approximately two octaves wide and is constrained within the five control columns on the Platinum Series front panel. Q: This is a form of frequency bandwidth control centered about the frequency region where the gain boost/cut is desired. Its value is calculated as the ratio of the center frequency to the bandwidth. The filter Q setting is indicated in the Q row of controls on the Platinum Series front panel. In equalizers, Q is the ratio of center frequency to bandwidth, and if the center frequency is fixed, then bandwidth is inversely proportional to Q, meaning that as you raise the Q, you narrow the bandwidth. For example, if the 1 kHz filter is set to 1 kHz, the Q will vary from (1618-618)/1000 = 1000/1000 = 1 minimum Q, or maximum bandwidth of 1000 Hz, to 1000/(1051-951) = 1000/100 = 10 maximum Q, or minimum bandwidth of 100 Hz. Q is the most useful tool a parametric EQ offers, allowing you to boost/cut (with the GAIN control for that frequency band) a very narrow or wide range of frequencies within each EQ band. A narrow bandwidth (high Q value) is particularly useful for removing unpleasant tones. By notching out the offending frequency, you can remove the problem without removing adjacent frequency content. A broad bandwidth (low Q value) boosts/cuts (with the GAIN control for that frequency band) a larger band of frequencies. Broad and narrow bandwidths (low and high Q, respectively) are usually used in conjunction with one another to achieve the desired sonic effect. Note: The lowest frequency (40 to 200 Hertz) parametric EQ band is limited in operational range when 70 Volt speaker operation is selected. Specifically, the GAIN control is disabled in the Boost half (from 0 to fully CW, 0 to +15dB) of its rotation. Similarly, the FREQ control is disabled in the lowest frequency range (from 0 to fully CCW, 100 down to 40 Hertz). This is to reduce the possibility of saturating the 70V output transformer at the lowest frequencies. 0 GAIN -15 +15 100 FREQ 40 200 Q3 1 10 0 -15 +15 400 190 600 3 1 10 0 -15 +15 1k 550 1.8k 3 1 10 0 -15 +15 2.8 k 1.6k 4k 3 1 10 0 -15 +15 EQ 7k 3.3k 16k 3 BYPASS 1 10 10 Variable Mute (Rear Panel: #6) The VAR MUTE control mutes the AUX input(s) only during telephone pages. The control allows the user to select from four levels of muting: 1 = -60 dB 2 = -21 dB 3 = -10 dB 4 = 0 dB Telephone Paging Controls & Settings (Front Panel: #3) The MIC 5/TEL volume control on the front panel controls the volume of the telephone paging input when the control is set to the TEL mode (See "MIC 5/TEL (Rear Panel: #10 and #11)" on page 6 for information on setting the TEL input mode). The TEL input mode uses voice-activated muting for the AUX inputs and automatic level control for providing constant paging level. To optimize TEL input performance, both the ALC control and the VOX threshold may need to be adjusted. ALC (Rear Panel: #17) The TEL input features an automatic level control (ALC) which compensates for different voice levels and speaking styles of the individuals using the system. The amplifier is shipped with this control in the OFF (max. counterclockwise) position. To adjust the ALC: 1. Rotate the MIC 5/TEL and MASTER controls to the highest level likely to be used. 2. Speak softly and distinctly into the telephone mouthpiece while adjusting the MIC 5/TEL volume control to the desired output level. 3. Speak in a loud voice directly into the telephone mouthpiece while rotating the ALC control clockwise to the point where the output of the amplifier is reduced to the same level as that obtained in Step 2. 4. The MIC 5/TEL and MASTER controls can be used to vary the overall volume without upsetting the ALC adjustment. MIC 5/TEL 4 6 2 8 0 10 11 VOX (Rear Panel: #18) The telephone page input features voice-activated AUX muting. This feature always mutes AUX 2 and only mutes AUX 1 when the AUX1/ MIC 6 switch is set in that position. The VOX control should be set so that only the desired signal is above the threshold level, while unwanted noise is below it. To adjust the sensitivity of the VOX circuit: 1. Rotate the VOX control fully clockwise. While making a public address announcement and talking at a low level, the sound should not be choppy or missing parts of words. If it is choppy or intelligibility is poor, rotate control counterclockwise to the point where the sound is clear and crisp (but not to the maximum counterclockwise position). 2. If the background music shuts down when no page is in progress, rotate the control clockwise until the music will not shut down when no page is in progress. LEDs (Front Panel: #10) · FAULT: This flashing LED will indicate a mode where the amplifier is self-protecting. This indication signifies a malfunction. For more information, refer to Amplifier flashes the FAULT LED in the Troubleshooting section. · LIMIT: This LED indicates full-power output. It also is calibrated at the level where the amplifier's output will no longer increase, even with increasing input, thus the amplifier is limiting its output power level. · -3 dB: The power-level indicator calibrated at 3 dB down or 1/2 from full power. · -6 dB: The power-level indicator calibrated at 6 dB down or 1/4 from full power. · -12 dB: The power-level indicator calibrated at 12 dB down or 1/16th from the amplifier's full power. · -24 dB: This LED is the beginning of a power-level indicator. Its calibration point is 24 dB down, or 1/256th, from the amplifier's full power output. · ON: Illuminates green to indicate power is on. FAULT LIMIT -3dB -6dB -12dB -24dB ON 12 Troubleshooting Amplifier will not turn ON. No audio output. Check the fuse. Replace fuse only with same type and rating. Double-check the position of the LINK switch. No telephone output. Double-check the position of the 70V | 8 OHMS/25V switch. Make sure that the MIC 5/TEL switch is in the TEL position. Make sure the VOX control is set properly. When connecting the telephone Tip and Ring, make sure to use the two outside terminals and not the center terminal (GND). AUX Input will not mute with telephone page. Check that the VAR MUTE control is not set to 4 (0 dB). This control adjusts the level of the background music when making a page. See "Variable Mute (Rear Panel: #6)" on page 11. Microphone squeals or hums when using Check your wiring connections for the 3-pin connector. Pin 1 is the the 3-pin connectors but not when using shield connection. Pins 2 and 3 connect to the balanced signal leads screw terminals. on the mic cable. Condenser MIC will not work. Make sure that phantom power switch (MIC 1 - 4) is on. See "MIC 14 (Rear Panel: #21 and #22)" on page 6. Telephone input cuts off the music when Adjust the VOX control on the rear panel to eliminate any unwanted not making a page. noise that may be triggering the VAR MUTE circuit. See "Variable Mute (Rear Panel: #6)" on page 11 Telephone input is choppy or cuts off the Adjust the VOX control counterclockwise to make the trigger activate beginning of a page. at a lower input signal level. See "VOX (Rear Panel: #18)" on page 12. The telephone page volume is too loud Adjust the ALC control on the rear panel. See "ALC (Rear Panel: #17)" on some pages. on page 11. AUX 1 Input not working. Make sure MIC 6/AUX 1 switch is in the AUX 1 position. Amplifier flashes the FAULT LED. Make sure the signal source is plugged into the AUX 1 RCA jack. There are several causes for the FAULT LED to flash: · Over-current. This is usually caused by the total speaker distribution impedance being below 8 ohms, probably due to wiring failure or installation errors. · High-temperature. Make sure that the amplifier's vent slots are not blocked and that there is adequate free air flow. · DC voltage present on the amplifier outputs. To recover from this condition, turn the power switch off, count to five, and then turn the power switch back on. · High-frequency protection. Detection circuitry will cause the amplifier to temporarily protect itself by muting the outputs. There is an automatic reset of the amplifier for this condition. 13 Technical Specifications Power Rating (RMS): Frequency Response: Distortion: Signal-to-Ratio Noise: Inputs MIC: AUX: TEL: Power Amp In: Outputs Pre Amp Out: Tape Output: Speaker Output: Output Regulation: AC Input Voltage: AC Current: Variable Mute Range: ALC: VOX Threshold: MIC/AUX/TEL Precedence: Phantom Power: Lo-Cut: Loudness Contour: Parametric Equalizer: Overload Protection: Thermal Protection: Dimensions: Shipping Weight: PS120: 120 watts; PS240: 240 watts 20 Hz to 20 kHz, +0/-2 dB ref 1 kHz, 8 ohms/25V 85 Hz to 20 kHz, +0/-3 dB ref 1 kHz, 70V 0.3% (typ.), 20 Hz to 20 kHz Fundamental: -70 dB or better; AUX 1 and 2: -70 dB; TEL: -70 dB or better @ 600 ohms; MIC 1 through MIC 6: -60 dB or better @ 200 ohms 6 Lo-Z balanced via 4 XLR connectors and 2 pluggable screw terminals, Sensitivity: 11mV (200 ohms) 2 Hi-Z RCA jacks. Sensitivity: 0.085V (10k ohms) Pluggable screw terminals. Sensitivity: 0.07V (600 ohms) In 1V via an RCA jack Out 1V via an RCA jack Pre-Master, 700 mV @ Rated Output via RCA jack All models: 8-ohm/25V or 70V, switch-selectable Better than 2 dB from no load to full load 100240VAC, 50/60 Hz PS60: 0.83A; PS120: 1.55A; PS240: 2.37A -60, -21, -10, 0 dB (AUX 1 and AUX 2) Distortion: less than 0.5%; Compression: 25 dB (TEL) TEL Input 20 mV (VOX control max. CW position) Via pluggable screw terminals. -60 dB: MIC 1, 2, 3, 5/TEL, 6/AUX 1, AUX 2 13V DC -3 dB @ 85 Hz, ref 1 kHz, 70V +8 dB @ 100 Hz, +4 dB @ 10 kHz (AUX 1 and AUX 2 control at 1/4 CW position) 5-bands with independent GAIN, FREQ, and Q controls Electronic with automatic reset Thermistor attached to heat sink 16-1/2" W × 3-1/2" H × 13-1/2" D All Models: 19 lb. 14 Warranty Limited Warranty, Exclusion of Certain Damages Bogen's Platinum Series amplifiers are warranted to be free from defects in material or workmanship for five (5) years from the date of sale to the original purchaser. Any part of any Bogen product covered by this warranty that, with normal installation and use, becomes defective (as confirmed by Bogen upon inspection) during the applicable warranty period, will be repaired or replaced by Bogen, at Bogen's option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 4570 Shelby Air Drive, Suite 11, Memphis, TN 38118 USA. Repaired or replacement product will be returned to you freight prepaid. This warranty does not extend to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced. THE FOREGOING LIMITED WARRANTY IS BOGEN'S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen's liability arising out of the manufacture, sale or supplying of products or their use or disposition, whether based upon warranty, contract, tort or otherwise, shall be limited to the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State. Products that are out of warranty will also be repaired by the Bogen Factory Service Department -- same address as above or call 201-934-8500. The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping charges in addition to parts and labor charges will be at the owner's expense. All returns require a Return Authorization number. For most efficient warranty or repair service, please include a description of the failure. Products manufactured and labeled by other companies may be covered by warranties offered by such companies. Please call Bogen Customer Service or refer to product packaging for manufacturer's warranty for non-Bogen branded products. 11/2014 15Adobe PDF Library 17.0