RF Exposure MPE Report for Scent Diffuser Pro 2

Report Reference No.: HTT202502686F02

FCC ID: 2BA6L-SDPRO2

Test Laboratory Information

Testing Laboratory Name: Shenzhen HTT Technology Co.,Ltd.

Address: 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China

Contact: Tel: 0755-23595200, Fax: 0755-23595201

Applicant Information

Applicant's Name: Guangdong Baixiang Environmental Technology Co., Ltd

Address: 6& 7th Floor, Building H, Lingyun Technology Park, No. 43 East Jinshi Avenue, Shiling Town, Huadu District, Guangzhou, China

Product Details

Test Item Description: Scent Diffuser Pro 2

Manufacturer: Guangdong Baixiang Environmental Technology Co., Ltd

Trade Mark: Scentiment

Model/Type Reference: Scent Diffuser Pro 2

Listed Models: SS2000, HVAC Diffuser, Scent Diffuser Pro 2, Diffuseur de Parfum Pro 2, Difusor de Aroma Pro 2

Model Difference: The PCB board, circuit, structure and internal of these models are the same; only the model number is different.

Operation Frequency: From 2412MHz~2462MHz

Rating: MODEL NO: D120-12V12WUS, INPUT: AC100-240V, 50/60Hz, 0.3A, OUTPUT: DC 12V, 1.0A

Test Standards

The tests were performed according to the following standards:

Summary of Test

Date of Receipt of Test Sample: Feb. 20, 2025

Testing Commenced On: Feb. 20, 2025

Testing Concluded On: Mar. 05, 2025

Result: PASS

Modifications: No modifications were implemented to meet testing criteria.

Test Environment

Address of the Test Laboratory

Shenzhen HTT Technology Co.,Ltd., 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China

Test Facility

The test facility is recognized, certified, or accredited by the following organizations:

Statement of the Measurement Uncertainty

The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report according to TR-100028-01 and TR-100028-02, and is documented in the Shenzhen HTT Technology Co.,Ltd. quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Measurement Capability:

TestRangeMeasurement UncertaintyNotes
Radiated Emission9KHz~30MHz3.12 dB(1)
Radiated Emission30~1000MHz4.37 dB(1)
Radiated Emission1~18GHz5.40 dB(1)
Radiated Emission18-40GHz5.45 dB(1)
Conducted Disturbance0.15~30MHz2.68 dB(1)

Test Limit and Requirements

Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure

Frequency Range(MHz)Electric Field Strength(V/m)Magnetic Field Strength(A/m)Power Density (mW/cm²)Averaging Time (minute)
0.3 – 3.06141.63(100) *6
3.0 – 301842/f4.89/f(900/f²)*6
30 – 30061.40.1631.06
300 – 1500//f/3006
1500 – 100,000//56

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure

Frequency Range(MHz)Electric Field Strength(V/m)Magnetic Field Strength(A/m)Power Density (mW/cm²)Averaging Time (minute)
0.3 – 3.06141.63(100) *30
3.0 – 30824/f2.19/f(180/f²)*30
30 – 30027.50.0730.230
300 – 1500//f/150030
1500 – 100,000//1.030

Note: F=frequency in MHz, *=Plane-wave equivalent power density

MPE Calculation Method

Predication of MPE limit at a given distance. Equation from page 18 of OET Bulletin 65, Edition 97-01:

S=PG/4πR²

Where: S=power density, P=power input to antenna, G=power gain of the antenna in the direction of interest relative to an isotropic radiator, R=distance to the center of radiation of the antenna.

Conducted Power Results

ModeTX TypeFrequency (MHz)Maximum Peak Conducted Output Power (dBm)
802.11bSISO241214.35
243714.69
246214.70
802.11gSISO241217.07
243717.44
246217.38
802.11n (HT20)SISO241216.95
243717.41
246217.34

Manufacturing Tolerance

ModeMax. Peak Conducted Output Power (dBm)Max. tune-up
2.4GWIFI17.4417.0 ± 1

Standalone MPE Result

As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons. From the maximum EUT RF output power, the minimum separation distance (r=20cm), as well as the gain of the used antenna (refer to section 2.2), the RF power density can be obtained.

Modulation TypeOutput power (dBm)Output power (mW)Antenna Gain (dBi)Antenna Gain (linear)MPE (mW/cm²)MPE Limits (mW/cm²)
2.4GWIFI18.063.09570.01.0000.01261.0000

Remark:

Conclusion

The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device Threshold per KDB 447498 D01v06.

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8137021 Microsoft Word 2021 Microsoft Word 2021

Related Documents

Preview Scent Diffuser Pro 2 Test Report - FCC Compliance by Shenzhen HTT Technology Co., Ltd.
Official test report from Shenzhen HTT Technology Co., Ltd. detailing the FCC compliance testing for the Scent Diffuser Pro 2 (Model: SS2000, FCC ID: 2BA6L-SDPRO2) by Guangdong Baixiang Environmental Technology Co., Ltd.
Preview Scent Diffuser Pro 2 User Manual: Setup, Operation, and Maintenance
Comprehensive user manual for the Scentiment Scent Diffuser Pro 2. Learn how to set up, operate, clean, and maintain your aroma diffuser, including troubleshooting and safety information.
Preview Scentiment Mini Diffuser 2 User Manual and Guide
Comprehensive guide for the Scentiment Mini Diffuser 2, covering setup, operation, maintenance, troubleshooting, and warranty information. Learn how to use the app, replace parts, and ensure optimal performance.