User Guide for Honeywell models including: CM701, PROGRAMMABLE THERMOSTAT

CM701

The CM701 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in...

Download

Product Group


File Info : application/pdf, 7 Pages, 754.65KB

PDF preview unavailable. Download the PDF instead.

en0h8543uk07r0805 - legacy product document
This is a legacy product document supported by Resideo. It is no longer manufactured

CM701
PROGRAMMABLE THERMOSTAT
PRODUCT SPECIFICATION SHEET
The CM701 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in conjunction with combiboilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<5A). The CM701 is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy.
The CM701 large LCD display, button layout based on the same simple programming philosophy used on our acclaimed CM20 products and the introduction of an `OK' button makes it easier to install and more user friendly.
The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product.

FEATURES
· Attractive slim, modern styling makes it ideal for
location in any type of home.
· 24 hour heating program.
· Up to 4 daily independent time and temperature level
changes let you set 4 time and temperatures pairs to suit your lifestyle.
· Temporary programmed temperature override to
temporarily override the programmed temperature till the next switch point.
· Room Temperature Enquiry.
· EEPROM memory holds the user program
indefinitely.
· OFF mode has an integral frost protection setting at
minimum 5°C (installer adjustable) so that pipes in the house will never freeze in winter.
· 24...230V 5A resistive, 2A inductive SPDT relay
provides compatibility with most domestic central heating systems reducing the need to stock many different models.
· Battery powered by 2 x AA size (LR6) alkaline cells.
· Minimum battery life of 2 years with low battery
warning indicator.
· Built-in default heating program.

· Surface or wall box mounting options, with trunking
guides and wiring breakouts to simplify installation.
· No installer links or special installer switches on the
back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems.
· User Set-Up Mode allows extra functions to be set at
the discretion of the user:
· AM-PM or 24hr time display.
· Resetting the heating profile to factory default.
· Installer Set-Up Mode allows extra functions to be set
at the discretion of the installer to match the consumers applications and needs:
· Pump Exercise. · Upper / Lower Set point Limit Adjust. · Temperature offset. · Minimum ON time. · Cycle rate. · Proportional Band Width. · Diagnostic Mode to assist in faultfinding.

EN0H 8543 UK07 R08/05

CONTROLS / DISPLAY LAYOUT

CM701 CHRONOTHERM
PRODUCT LAYOUT:
1. LCD Screen 2. Battery Low Indicator 3. Time Display 4. Burner On Indicator 5. Temperature Display 6. Temperature Change Buttons 7. Information Enquiry Button 8. Operating Mode Buttons 9. Green OK Button 10. Battery Compartment 11. Battery Cover 12. Program Buttons 13. Time Change Buttons

SPECIFICATIONS

Batteries

: 2 x 1.5 V IEC LR6 (AA) Alkaline cells

Battery life

: Minimum 2 years

Battery replacement

: Program retained in EEPROM

Switch type

: SPDT (potential free)

Electrical rating

: 230 V~, 50...60 Hz, 0.1 A to 5 A resistive 0.1 A to 2 A inductive (0.6 pf) 24 V~, 50...60 Hz, 0.5 A to 5 A resistive 0.5 A to 2 A inductive (0.6 pf)

Time display : 24 hour or 12 hour AM/PM format

Time keeping : Typically better than 10 minutes per year accuracy

Program

: 4 daily time and temperature level changes

Time setting resolution

: Time of day - 1 minute Program - 10 minute steps

Sensing element : 100K (@ 25 oC ) NTC thermistor

Temperature setting range

: Program : 5 to 35oC in 0.5 oC steps Frost : 5 oC or equal to lower limit (5 oC to 21 oC).

Temperature : ±0.5 K (nominal) @ 20oC, 50% load control accuracy 3 K /hour

Room Temperature display range

: From 0 oC to 50 oC

Control form : P + I (Proportional + Integral)

Minimum ON time

: 10% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up)

Cycle rate

: Selectable by application (see installer set up)

Wiring

: Terminal block capable of accepting wires up to 2.5 mm2

Wire access

: Mains wiring ­ rear right. Low voltage wiring ­ rear right.

Dimensions

: 133 x 88.5 x 26 mm (w x h x d) 130 x 175 x 26 mm (w x h x d) (flap open)

Environmental

: Operating temperature range 0 to 40oC
Shipping and storage temperature range -20 to 55oC
Humidity range 10 to 90% rh, non-
condensing

Approvals

: Designed to meet European EN approvals EN60730-1(Nov 2000), EN55014-1 (1997), EN55014-2 (2000)

2

EN0H 8543 UK07 R08/05

INSTALLER SET-UP
To enter the installer set-up mode: a) Press the OFF button.
b) Press and hold the INFO i button and the two program
buttons `< >' together. c) The unit will display the first parameter of installer
parameter group category 1 (from n.1 to n.19). d) Press the TEMP or buttons to change the factory
setting. The display will flash indicating that a change has been made. e) Press the green OK button to confirm this change and the display will stop flashing. f) Press the + button to go to the next parameter.
g) Press the program button > to go to category 2 in the
Installer mode (from n.1 to n.5). h) To exit the installer mode, press the AUTO, MAN or OFF
buttons.
In Installer set-up we can:
 Set-up specific applications  Enable special features

CM701 CHRONOTHERM

Abbreviated Set-Up Description e.g. Cl = Clock Format

Installer Set-up Number
(Press + or - to change) e.g. 1 = Clock Format

Factory Setting or New Choice

Press TEMP

or

to change

e.g. 12 = AM/PM Format

24 = 24hr Format

Specific Applications

Setting
Cycle/ Minimum Hour ON time
(in minutes)

What do you need to change?
Note : a. To change Cycle/Hour, please go to parameter n. 2, category 2
in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n. 1,
category 2 in the installer set-up mode.

Heating

Gas Boilers (<30KW)

6

1

No action required

Oil Boiler

3

4

1. Set Minimum ON Time to 4 minutes.

2. Set Cycle/Hour to 3.

Thermal Actuator 12

Zone valve

6

Electric heating

12

(for applications

<5A)

1

Set Cycle/Hour to 12.

1

No action required.

1

1. Set Cycle/Hour to 12.

3

EN0H 8543 UK07 R08/05

CM701 CHRONOTHERM

Special Features

Description

What to do if we wish this feature

AM-PM/ 24hr Display

Change display format (default 24hr).

Set parameter n.1, category 1 in the installer set -up mode to 12.

Pump exercise

When enabled the Pump Exercise will switch the relay on for 1 minute at 12:00 if the relay has not been switched on since 12:00 the previous day.
While in Holiday mode the Pump Exercise feature, if enabled, will operate.

Set parameter n.5, category 2 in the installer set -up mode to 1.

Upper Temperature Limit The normal upper temperature limit of 35 oC can be reduced down to 21 oC to save the homeowner energy.
Useful if the homeowner rents to tenants.

Set parameter n.6, category 1 in the installer set -up mode to the desired limit.

Lower Temperature Limit

The normal lower temperature limit of 5 oC can be increased up to 21 oC to protect the inhabitants from
cold. Useful if the inhabitants include the elderly,
children or disabled.

Set parameter n.7, category 1 in the installer set -up mode to the desired limit.

Temperature Offset

If the thermostat is located in a hot/cold location and
cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 3 oC.
Useful if the homeowner wants the reading to match
another appliance temperature display.

Set parameter n.12, category 1 in the installer set -up mode to the desired offset value.

Proportional Band Width

Can be adjusted up to 3 oC (default is 1.5 oC) to provide better temperature control (less overshoot).
Useful for:
a. Well insulated homes with over-sized heating systems.
b. Air systems with fast response.

Set parameter n.13, category 1 in the installer set -up mode to the desired value.

4

EN0H 8543 UK07 R08/05

CM701 CHRONOTHERM

Parameter

Installer SetUp Number / Abbreviation (Press + or keys to select)

Factory Setting Display Description

Optional Setting Display/Setting Description

Installer SetUp Category
(Press PROG keys `< or >' to select)

Category 1: Thermostat Parameters

AM-PM / 24hr Display
RESET Time / Temperature Program

1:Cl

24 24 hr clock display

12

12 hr AM / PM clock display

1

2:rP

1

Time / Temperature

0

Time / Temperature are

1

profile set to factory

as programmed

default

1

To restore the factory

Changes to 0 when

profile set to 1

one of the time/temp

profiles are changed

Upper

6:uL

35 35°C Upper Temp.

21 to 34

21°C to 34°C

1

Temperature Limit

Limit

adjustment in 1°C steps

Lower

7:LL

Temperature Limit

5

5°C Lower Temp.

6 to 21

6°C to 21°C adjustment

1

Limit

in 1°C steps

Temperature Offset

12:tO

0

No offset

-3 to +3

-3°C to +3°C adjustment

1

in 0.1°C steps

Proportional Band

13:Pb

1.5 1.5°C Proportional

1.6 to 3.0

1.6°C to 3.0°C

1

Width

Band

adjustment in 0.1°C

steps

Reset Parameters to Factory Defaults

19:FS

1

All settings held are

the factory defaults.

Changes to 0 when

one of the

parameter values

are changed

0

Settings are as modified

1

above

1

To restore the factory

profile set to 1

`Category 2: System Parameters (You must press the `>' program key to enter this section)

Minimum ON Time

1:Ot

1

1 minute minimum

2 to 5

2 - 2 minutes

2

ON time

3 - 3 minutes

4 - 4 minutes

5 - 5 minutes

Cycle Rate

2:Cr

6

6 cycles per hour

3, 9, 12

3 - 3 cph

2

(cph) for gas boilers,

9 - 9cph

zone valves and fancoil

12 - 12 cph

Pump Exercise

5:PE

0

Pump Exercise

Disabled

1

Pump Exercise Enabled

2

5

EN0H 8543 UK07 R08/05

DIMENSIONS

CM701 CHRONOTHERM

INSTALLATION

LOCATION
The CM701 thermostat is the control element of the heating system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall, 1.5 metres above the floor level. Do not position the CM701 thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight.
MOUNTING
The CM701 thermostat can be mounted directly on the wall surface or on to an electrical wall box.
WIRING
The CM701 thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.E.E. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 5 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles).
IMPORTANT
1. The installer must be a trained service engineer 2. Disconnect the power supply before beginning
installation

6

EN0H 8543 UK07 R08/05

WIRING

CM701 CHRONOTHERM

ORDERING SPECIFICATION

Description 1-day programmable thermostat

Model

Logo

Literature

CMT701A1006 Honeywell French, Dutch, Italian, Spanish, German, Portuguese.

Spec Sheet ENOH8543

Honeywell Control Systems Limited Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom

http://europe.hbc.honeywell.com EN0H 8543 UK07 R08/05



References

Acrobat Distiller 5.0.5 (Windows)