User Guide for Honeywell models including: CM701, PROGRAMMABLE THERMOSTAT
The CM701 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in...
Product Group
File Info : application/pdf, 7 Pages, 754.65KB
DocumentDocumentThis is a legacy product document supported by Resideo. It is no longer manufactured CM701 PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM701 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in conjunction with combiboilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<5A). The CM701 is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The CM701 large LCD display, button layout based on the same simple programming philosophy used on our acclaimed CM20 products and the introduction of an `OK' button makes it easier to install and more user friendly. The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product. FEATURES · Attractive slim, modern styling makes it ideal for location in any type of home. · 24 hour heating program. · Up to 4 daily independent time and temperature level changes let you set 4 time and temperatures pairs to suit your lifestyle. · Temporary programmed temperature override to temporarily override the programmed temperature till the next switch point. · Room Temperature Enquiry. · EEPROM memory holds the user program indefinitely. · OFF mode has an integral frost protection setting at minimum 5°C (installer adjustable) so that pipes in the house will never freeze in winter. · 24...230V 5A resistive, 2A inductive SPDT relay provides compatibility with most domestic central heating systems reducing the need to stock many different models. · Battery powered by 2 x AA size (LR6) alkaline cells. · Minimum battery life of 2 years with low battery warning indicator. · Built-in default heating program. · Surface or wall box mounting options, with trunking guides and wiring breakouts to simplify installation. · No installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems. · User Set-Up Mode allows extra functions to be set at the discretion of the user: · AM-PM or 24hr time display. · Resetting the heating profile to factory default. · Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumers applications and needs: · Pump Exercise. · Upper / Lower Set point Limit Adjust. · Temperature offset. · Minimum ON time. · Cycle rate. · Proportional Band Width. · Diagnostic Mode to assist in faultfinding. EN0H 8543 UK07 R08/05 CONTROLS / DISPLAY LAYOUT CM701 CHRONOTHERM PRODUCT LAYOUT: 1. LCD Screen 2. Battery Low Indicator 3. Time Display 4. Burner On Indicator 5. Temperature Display 6. Temperature Change Buttons 7. Information Enquiry Button 8. Operating Mode Buttons 9. Green OK Button 10. Battery Compartment 11. Battery Cover 12. Program Buttons 13. Time Change Buttons SPECIFICATIONS Batteries : 2 x 1.5 V IEC LR6 (AA) Alkaline cells Battery life : Minimum 2 years Battery replacement : Program retained in EEPROM Switch type : SPDT (potential free) Electrical rating : 230 V~, 50...60 Hz, 0.1 A to 5 A resistive 0.1 A to 2 A inductive (0.6 pf) 24 V~, 50...60 Hz, 0.5 A to 5 A resistive 0.5 A to 2 A inductive (0.6 pf) Time display : 24 hour or 12 hour AM/PM format Time keeping : Typically better than 10 minutes per year accuracy Program : 4 daily time and temperature level changes Time setting resolution : Time of day - 1 minute Program - 10 minute steps Sensing element : 100K (@ 25 oC ) NTC thermistor Temperature setting range : Program : 5 to 35oC in 0.5 oC steps Frost : 5 oC or equal to lower limit (5 oC to 21 oC). Temperature : ±0.5 K (nominal) @ 20oC, 50% load control accuracy 3 K /hour Room Temperature display range : From 0 oC to 50 oC Control form : P + I (Proportional + Integral) Minimum ON time : 10% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up) Cycle rate : Selectable by application (see installer set up) Wiring : Terminal block capable of accepting wires up to 2.5 mm2 Wire access : Mains wiring rear right. Low voltage wiring rear right. Dimensions : 133 x 88.5 x 26 mm (w x h x d) 130 x 175 x 26 mm (w x h x d) (flap open) Environmental : Operating temperature range 0 to 40oC Shipping and storage temperature range -20 to 55oC Humidity range 10 to 90% rh, non- condensing Approvals : Designed to meet European EN approvals EN60730-1(Nov 2000), EN55014-1 (1997), EN55014-2 (2000) 2 EN0H 8543 UK07 R08/05 INSTALLER SET-UP To enter the installer set-up mode: a) Press the OFF button. b) Press and hold the INFO i button and the two program buttons `< >' together. c) The unit will display the first parameter of installer parameter group category 1 (from n.1 to n.19). d) Press the TEMP or buttons to change the factory setting. The display will flash indicating that a change has been made. e) Press the green OK button to confirm this change and the display will stop flashing. f) Press the + button to go to the next parameter. g) Press the program button > to go to category 2 in the Installer mode (from n.1 to n.5). h) To exit the installer mode, press the AUTO, MAN or OFF buttons. In Installer set-up we can: Set-up specific applications Enable special features CM701 CHRONOTHERM Abbreviated Set-Up Description e.g. Cl = Clock Format Installer Set-up Number (Press + or - to change) e.g. 1 = Clock Format Factory Setting or New Choice Press TEMP or to change e.g. 12 = AM/PM Format 24 = 24hr Format Specific Applications Setting Cycle/ Minimum Hour ON time (in minutes) What do you need to change? Note : a. To change Cycle/Hour, please go to parameter n. 2, category 2 in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n. 1, category 2 in the installer set-up mode. Heating Gas Boilers (<30KW) 6 1 No action required Oil Boiler 3 4 1. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Thermal Actuator 12 Zone valve 6 Electric heating 12 (for applications <5A) 1 Set Cycle/Hour to 12. 1 No action required. 1 1. Set Cycle/Hour to 12. 3 EN0H 8543 UK07 R08/05 CM701 CHRONOTHERM Special Features Description What to do if we wish this feature AM-PM/ 24hr Display Change display format (default 24hr). Set parameter n.1, category 1 in the installer set -up mode to 12. Pump exercise When enabled the Pump Exercise will switch the relay on for 1 minute at 12:00 if the relay has not been switched on since 12:00 the previous day. While in Holiday mode the Pump Exercise feature, if enabled, will operate. Set parameter n.5, category 2 in the installer set -up mode to 1. Upper Temperature Limit The normal upper temperature limit of 35 oC can be reduced down to 21 oC to save the homeowner energy. Useful if the homeowner rents to tenants. Set parameter n.6, category 1 in the installer set -up mode to the desired limit. Lower Temperature Limit The normal lower temperature limit of 5 oC can be increased up to 21 oC to protect the inhabitants from cold. Useful if the inhabitants include the elderly, children or disabled. Set parameter n.7, category 1 in the installer set -up mode to the desired limit. Temperature Offset If the thermostat is located in a hot/cold location and cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 3 oC. Useful if the homeowner wants the reading to match another appliance temperature display. Set parameter n.12, category 1 in the installer set -up mode to the desired offset value. Proportional Band Width Can be adjusted up to 3 oC (default is 1.5 oC) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems. b. Air systems with fast response. Set parameter n.13, category 1 in the installer set -up mode to the desired value. 4 EN0H 8543 UK07 R08/05 CM701 CHRONOTHERM Parameter Installer SetUp Number / Abbreviation (Press + or keys to select) Factory Setting Display Description Optional Setting Display/Setting Description Installer SetUp Category (Press PROG keys `< or >' to select) Category 1: Thermostat Parameters AM-PM / 24hr Display RESET Time / Temperature Program 1:Cl 24 24 hr clock display 12 12 hr AM / PM clock display 1 2:rP 1 Time / Temperature 0 Time / Temperature are 1 profile set to factory as programmed default 1 To restore the factory Changes to 0 when profile set to 1 one of the time/temp profiles are changed Upper 6:uL 35 35°C Upper Temp. 21 to 34 21°C to 34°C 1 Temperature Limit Limit adjustment in 1°C steps Lower 7:LL Temperature Limit 5 5°C Lower Temp. 6 to 21 6°C to 21°C adjustment 1 Limit in 1°C steps Temperature Offset 12:tO 0 No offset -3 to +3 -3°C to +3°C adjustment 1 in 0.1°C steps Proportional Band 13:Pb 1.5 1.5°C Proportional 1.6 to 3.0 1.6°C to 3.0°C 1 Width Band adjustment in 0.1°C steps Reset Parameters to Factory Defaults 19:FS 1 All settings held are the factory defaults. Changes to 0 when one of the parameter values are changed 0 Settings are as modified 1 above 1 To restore the factory profile set to 1 `Category 2: System Parameters (You must press the `>' program key to enter this section) Minimum ON Time 1:Ot 1 1 minute minimum 2 to 5 2 - 2 minutes 2 ON time 3 - 3 minutes 4 - 4 minutes 5 - 5 minutes Cycle Rate 2:Cr 6 6 cycles per hour 3, 9, 12 3 - 3 cph 2 (cph) for gas boilers, 9 - 9cph zone valves and fancoil 12 - 12 cph Pump Exercise 5:PE 0 Pump Exercise Disabled 1 Pump Exercise Enabled 2 5 EN0H 8543 UK07 R08/05 DIMENSIONS CM701 CHRONOTHERM INSTALLATION LOCATION The CM701 thermostat is the control element of the heating system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall, 1.5 metres above the floor level. Do not position the CM701 thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight. MOUNTING The CM701 thermostat can be mounted directly on the wall surface or on to an electrical wall box. WIRING The CM701 thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.E.E. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 5 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles). IMPORTANT 1. The installer must be a trained service engineer 2. Disconnect the power supply before beginning installation 6 EN0H 8543 UK07 R08/05 WIRING CM701 CHRONOTHERM ORDERING SPECIFICATION Description 1-day programmable thermostat Model Logo Literature CMT701A1006 Honeywell French, Dutch, Italian, Spanish, German, Portuguese. Spec Sheet ENOH8543 Honeywell Control Systems Limited Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom http://europe.hbc.honeywell.com EN0H 8543 UK07 R08/05