Instruction Manual for murdock models including: BF15S, BF16, BF15S Series Wall Mount Pushbutton Bottle Filler, BF15S Series, Wall Mount Pushbutton Bottle Filler, Pushbutton Bottle Filler, Bottle Filler, Filler

7021-048-001 BF15S

MANUAL;INSTALLATION;BF16;BOTTLE FILLER;H20 TO GO;SURFACE MOUNTED;SENSOR;OPERATED;PUSHBUTTON;BF15

"MANUAL;INSTALLATION;BF16;BOTTLE, FILLER;H20, TO, GO;SURFACE, MOUNTED;SENSOR;OPERATED;PUSHBUTTON;BF15"

ACORN ENGINEERING COMPANY

MANUAL

Murdock BF15S | Wall-Mount Pushbutton Bottle Filler – BottleFillingStations.com SPEC SHEET


File Info : application/pdf, 9 Pages, 1.62MB

PDF preview unavailable. Download the PDF instead.

Model BF15S manual 7021-048-001 20BF15S ?v=1746096688
Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS
BF15S Series Surface Mounted, Push Button Operated Bottle Filler

Please visit www.murdockmfg.com for most current specifications.

BF15S Series Push Button Operation

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.743.8259
Technical Assistance E-Mail: Fieldservice@acorneng.com

Please refer to the Link or QR code provided. For Cleaning & Care Guide: CLEANING & CARE

NOTES TO INSTALLER: 1. Please leave this documentation with the owner of the fixture when finished. 2. Please read this entire booklet before beginning the installation. 3. Check your installation for compliance with plumbing, electrical and other applicable codes.

For current Warranty click hyperlink Product Warranty or visit: www.murdockmfg.com/terms-and-warranty

MurdockTM assumes no responsibility for use of void or superseded data. © Copyright Murdock Mfg., City of Industry, CA Member of Morris Group International. Please visit www.murdockmfg.com for most current specifications.
7021-048-001 Date: 10/22/2024 A

COMPLIES WITH

Federal Public Law 111-380 (No Lead)

Member of

15125 Proctor Ave, City of Industry, CA, 91746 U.S.A.
Phone 800-591-9360 626-336-4561
Rewvwiswe.md:ur0d8o/c1km3/f2g.0com

Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS
PRIOR TO INSTALLATION
Important: Some options may slightly alter installation. To ensure proper installation, review the manual thoroughly and verify rough-ins before beginning any work. File this Manual with the owner or maintenance personnel upon completion of installation.
-- Fixture mounting requirements: Industry standard wall construction, adequate to support the fixture and (installer provided) wall anchors sufficient to secure the fixture.
-- Fixture operates within water pressure range of 20 to 105 PSIG. Murdock will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 PSIG or higher than 105 PSIG.
-- Per UPC 609.10- All building water supply systems in which quick acting valves are installed shall be provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices will be installed as close as possible to the quick closing valve.
-- Water supply inlet is 3/8" O.D. Copper Tube. -- Completely flush supply of all foreign debris before connecting to fixture. Bottle Filler is designed to provide trouble- free
drinking water unaffected by fixture connection tubing and fittings and not cause problems with taste, odor, color or sediment. -- Electrical Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. (National
Electrical Code).
DIMENSIONAL DRAWING
BF15S Surface Mounted Bottle Filler
Prior to roughing in, consult with local, state, and federal codes for proper mounting height.

634" (187)

1734" [464]

558" [124]

29" [749]

1358" [321]

3421" [876] A.F.F.

1078" [308]

534" (130)

ALL DIMENSIONS ARE IN INCHES (MM)

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-048-001

Page 2 of 9

Member of
Date: 10/22/2024 A

Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS ROUGH-IN:
1 Provide wall openings as indicated in rough-in detail provided, ensuring to block out the Waste connection for 1-1/2" Waste Outlet. Use Mounting Channel as template.

334" [95] TYP.
1438" [365] TYP.

GENERAL NOTES:

1. ALL DIMENSIONS ARE IN INCHES (mm)

2. DIMENSIONS INDICATED WITH (*) IS FOR

34-1/2" DECK HEIGHT. ADJUST

ACCORDINGLY FOR PREFERRED DECK

HEIGHT.

4

3. SEPARATE BOTTLE FILLER HOUSING

FROM MOUNTING CHANNEL IF USED AS

TEMPLATE IF APPLICABLE.

4. DIMENSION KEYHOLES AT TOP OF UNIT

3

AT 51-3/8" TO HAVE A DECK HEIGHT OF

34-1/2".

12" [305] 5138" [1303]
*2858" [728] A.F.F.

321" [89]

4" [102]

641" [159]

2
1
*29" [737] A.F.F. *27" [686] A.F.F.

3421" (876) Deck Height Notch
A.F.F.
1 3/8" NTC Supply Inlet 2 Waste Outlet for 1-1/2" P-trap 3 Mounting Panel 4 Ø1/4" Holes for Anchoring
Hardware, By others

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-048-001

Page 3 of 9

Member of
Date: 10/22/2024 A

Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS:

2 Hang the unit from the two keyholes located at the top of the mounting channel and remove the two screws located near the top of the housing.

1 Housing

3 Keyhole

3

Finished Wall

2 Mounting Channel 4 Wire Strap

1

Additional Mounting Points

4 2

Note: Dimension Keyholes at 51-3/8" above finished floor for a deck height of 34-1/2". Unit Shown with Optional Filter Refer to page WF300.
3 Remove the Wire Strap to allow the housing to fully rotate down. Finish securing the unit to the wall by using the additional mounting points.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-048-001

Page 4 of 9

Member of
Date: 10/22/2024 A

Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS
INSTALLATION INSTRUCTIONS CONTINUED:
4 With the Mounting Channel secured to finished wall, install 1-1/2" P-Trap Waste Outlet.

1

2

3

3

4"

Max

Top View

1 Mounting Channel

2 2

2 P-Trap by others, must not exceed more than 4-1/4" from finished wall
3 Drain Trap with 1-1/2" Waste Outlet

5 Connect 1/4" O.D. x 1/2" "Y" Strainer assembly to main water supply. Recommend using angle stop for easy maintenance. Angle stop must not extend more than 3-1/2" from finished wall.

1 Mounting Channel
2 "Y" Strainer
3 1/2" Angle Stop by others recommended

2
3 21" (89) MAX

2

1

Shown with optional

Water Filter. Refer

to page 7 for Filter

3

Installation.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-048-001

Page 5 of 9

3
Member of
Date: 10/22/2024 A

Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS
INSTALLATION INSTRUCTIONS CONTINUED:

3

6 With fixture tested, hook Wire Strap from Bottle filler Housing to Mounting Panel and tighten Screw.

1 Bottle Filler Housing

2 Wire Strap

1

3 Mounting Channel

4 Wire Trap Mounting

4

Screw

2

7 Lift up from Fill Spout area to close the unit by swinging Bottle Filler Housing up and secure with Screws from step 1. Do not force closed. Address any interference if necessary. Do not over-tighten.

1 Bottle Filler Assembly
2 #10-32 x 1/2" Long Philips Head Screw

4 2

3 Bottle Filler Housing

4 Mounting Channel

3

1

8 To open unit for maintenance purposes, remove Top Screws. Lift Bottle Filler Housing up from Fill Spout area then pull away from wall.
4

2

1

3

1 Bottle Filler Assembly
2 #10-32 x 1/2" Long Philips Head Screw
3 Bottle Filler Housing
4 Mounting Channel

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-048-001

Page 6 of 9

Member of
Date: 10/22/2024 A

Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS

OPTIONAL WF3000 INSTALLATION:

WF3000 - Important - Before Starting
Y Turn water service off before attempting installation.
Y Refer to Push-in Fittings installation for information on connecting, disconnecting and testing Push-In Fittings.
Y Test fittings and restore water service prior to encasing with insulation tubing.
Y NOTE: Fittings and ¼" OD Tubing shown for clarity however insulation tubing may conceal fittings.
Y NOTE: Mounting the Filter on the right side of the frame, the "OUT" port or outlet side of the filter should always be facing the center of the frame assembly.
INSTALLATION INSTRUCTIONS:

Figure 1.

1. Access Filter Compartment: Remove screws [1] at the top of the
bottle filler to free the face from the Housing Back Plate Assembly and lower to fully open position. Figure 1.

2. Prep Water Supply Riser: Remove supply riser tubing [2] from center
Fixing loop [3] (Figure 2.) . Disconnect 1/4" O.D. tubing connector [4] as show in Figure 3.

3. Install Filter In-Line: Using Push-in elbows [5] dry fit 1/4" O.D. tubing
to Filter Cap [6] to the "IN" port of the Filter (Water Supply Side) and to the "OUT" port to the control valve inlet [7]. If needed, cut 1/4" tubing as required for proper fit. Figure 3 & Figure 4.

4. Mount Filter Assembly: Route
Supply Tubing [8] through center Fixing Loop [3]. Mount the Filter [9] to the upper back plate as shown. Figure 5 & Figure 6.

To Valve Inlet = OUT

SEPARATE

Figure 2.

From Water Supply = IN

Figure 3.

To Valve Inlet = "OUT"

From Water Supply = "IN"

Figure 4.

Figure 5.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-048-001

Page 7 of 9

Figure 6.
Member of
Date: 10/22/2024 A

Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS
PUSH-IN FITTING INSTALLATION
NOTE: FITTINGS AND TUBE SHOULD BE KEPT CLEAN, BAGGED AND UNDAMAGED PRIOR TO INSTALLATION.
TO CUT TUBE: Cut to fit length of 1/4" PE Tubing and remove any burrs or sharp edges. Ensure that the outside diameter is free from score marks. Tube ends should be square.

INSERTING THE TUBE: 1. Firmly and fully insert the Tubing end into the Push-In
Fitting up to the Tube Stop located approximately 1/2" deep.
2. Pull on the fitted Tubing to ensure it is secure. Tube should not come free from the Fitting. Water test the connection assembly prior to leaving the site to ensure there are no leaks.

COLLET

O-RING O-RING

TUBE STOP COLLET

COLLET

DISCONNECTING THE TUBE: Prior to disconnecting the Tube from the Fitting, ensure that the water line is depressurized. Push Collet Square towards the Push-In Fitting Body and hold. While holding the Collet in, pull on the PE Tubing to remove from the Push-In Fitting.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-048-001

Page 8 of 9

COLLET
COLLET
Member of
Date: 10/22/2024 A

BFS15 PARTS LIST BOTTLE FILLER PARTS BREAKDOWN
11

Surface Mounted Bottle Fillers
INSTALLATION/MAINTENANCE INSTRUCTIONS
1

12

76 9

5

10

4

8

3

2

ITEM # PART NUMBER DESCRIPTION 1 CALL MFG WALL MOUNTED FRAME ASSY., BF15S 2 CALL MFG HOUSING ASSEMBLY, BF15S 3 4970-265-000 P-TRAP 4 0116-114-000 #10-32 x 1" SS PHIL RD HD SCREW 5 7003-096-001 "Y" STRAINER 6 2169-000-000 1/4" O.D. LLDPE TUBING, BLUE

ITEM # PART NUMBER DESCRIPTION 7 7012-055-000 FOAM PIPE INSULATION 8 1895-709-000 ELBOW, 1/4" PUSH-IN 1/4" STEM 9 2150-000-000 1/8" O.D. LLDPE TUBING 10 2566-160-001 (-PBH) S/T SIDE OUTLET PUSHBUTTON 11 7014-486-001 NON-METERING AIR-TROL VALVE ASSY 12 1895-121-000 1/4" OD TUBE UNION PUSH-IN

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-048-001

Page 9 of 9

Member of
Date: 10/22/2024 A



References

Corel PDF Engine Version 23.0.0.363