Icon Fires Slimline Burner Manual

www.iconfires.com

Operating Manual

Thank you for purchasing this Icon Fires product. Icon Fires places the highest priority on safety of its products. Every care has been taken in designing, manufacturing and assembling your Icon Fires Burner to ensure it operates effectively, efficiently and safely. Live-fire products must be treated with care. We ask that you exercise care when using this product and follow the instructions below. Before using your Icon Fires Burner, please read all the information contained in this Operation Manual carefully. Icon Fires cannot be held responsible for any damage or injury caused if these instructions are not followed.

Retain this Manual for future reference.

IMPORTANT SAFEGUARDS

When using this Fireplace, basic precautions should always be followed, including but not limited to the following. Read all instructions and warnings before using this Fireplace.

WARNING

CAUTION

Trouble shooting and operating tips:

CONTENT OF PACKAGING:

* Australian models are not supplied with a Fuel Pump. They are supplied with the mandatory fuel canister with flame arrestor.

MAKE SURE THE FIREPLACE HAS COOLED OFF COMPLETELY BEFORE CLEANING:

KEEP HANDY A CLASS ABE FIRE EXTINGUISHER:

Class ABE fire extinguishers are used to put out fires that are caused by combustible liquids. Class ABE fire extinguishers quell the flames by expelling a dry chemical powder or foam with a nitrogen propellant. The specific chemical can vary depending on the make or model. Water will not extinguish this flame.

PROCEDURE IF BURNER IS OVERFILLED:

In case of accidental overfilling of the fuel tank, follow these steps:

USE CORRECT FUEL: BIOETHANOL

Slimline Burner Range

The following information is provided to assist in understanding how each model within our collection can be incorporated into your desired settings. It is intended as a guide only and it is important that you read the detailed Model Specification of the model you are interested in before ordering, specifying, installing or operating the fire.

Model No. Dimensions in mm (L x W x H) Approx. Fuel Capacity Material Heats On Average Minimum Room Area Thermal Output Net Burning Time On *Average Consumption *Average
SB500 500x100x100 2.75 l Brushed 304 SS up to 210 m³ 40 m³ 5.0 kW/hr 6-9 hrs 0.30 l/hr
SB800 800x100x100 4.50 l Brushed 304 SS up to 90 m³ 70 m³ 7.25 kW/hr 5.5-8.5 hrs 0.60 l/hr
SB1100 1100x125x100 6.25 l Brushed 304 SS up to 165 m³ 90 m³ 9.5 kW/hr 6.5-9 hrs 0.90 l/hr
SB1400 1400x125x100 8.15 l Brushed 304 SS up to 270 m³ 110 m³ 10.5 kW/hr 7-9.5 hrs 0.90 l/hr
RD380 380x380x100 6 l Brushed 304 SS up to 290 m³ 130 m³ 12 kW/hr 6-12 hrs 0.65 l/hr

*Average consumption and burn time are based on mixed settings of maximum and moderate output. These burn times and consumption rates may vary depending on room characteristics.

Accompanying Accessories

Model No. Burner & Lid Fuel Pump* Handles Instruction Manual
SB500 yes yes 1 yes
SB800 yes yes 2 yes
SB1100 yes yes 2 yes
SB1400 yes yes 2 yes
RD380 yes no 1 yes

* Australian models are not supplied with a fuel pump. They are supplied with the mandatory fuel canister with flame arrestor.

Burner cut out dimensions

Round Burner - RD380

Top View: Ø380

Front View: Ø345 cutout, 17.5mm height, 17.5mm width

Side View: Ø345 cutout, 17.5mm height, 17.5mm width

SB500

Top View: 545mm length, 145mm height, cutout 530mm length, cutout 100mm height

Front View: 545mm length, 145mm height, cutout 530mm length, cutout 130mm height

Side View: 145mm height, 7.5mm width, cutout 130mm height, 4mm width

SB800

Top View: 845mm length, 170mm height, cutout 830mm length, cutout 155mm height

Front View: 845mm length, 170mm height, cutout 830mm length, cutout 130mm height

Side View: 170mm height, 7.5mm width, cutout 130mm height, 7.5mm width

SB1100

Top View: 1145mm length, 170mm height, cutout 1130mm length, cutout 155mm height

Front View: 1145mm length, 170mm height, cutout 1130mm length, cutout 130mm height

Side View: 170mm height, 7.5mm width, cutout 130mm height, 7.5mm width

SB1400

Top View: 1445mm length, 170mm height, cutout 1430mm length, cutout 155mm height

Front View: 1445mm length, 170mm height, cutout 1430mm length, cutout 130mm height

Side View: 170mm height, 7.5mm width, cutout 130mm height, 7.5mm width

NOTE: There are many different variations available for installing the Burner Range. In all cases, the Slimline Burner must:

Installation Clearances

NOTE: all distances are measured from the top plate of the burner, these distances are very important to ensure safe and efficient usage

Burner Clearances

Model TO COMBUSTIBLE MATERIALS TO NON-COMBUSTIBLE MATERIALS
A B C D A B C D
SB500 1000mm 1000mm 2000mm 2000mm 50mm 50mm 500mm 500mm
SB800 1000mm 1000mm 2000mm 2000mm 50mm 50mm 500mm 500mm
SB1100 1000mm 1000mm 2000mm 2000mm 50mm 50mm 500mm 500mm
SB1400 1000mm 1000mm 2000mm 2000mm 50mm 50mm 500mm 500mm
RD380 1000mm 1000mm 2000mm 2000mm 50mm 50mm 500mm 500mm

1 - Filling the Slimline Burner

Top Plate

Top Plate Sliding Lid

Handle Hole

Filling Line

Burner Vent

Vent Plate

Fuel Tank

Handle Hole

Closing Lid

Small Reducer

Large Reducer

Filling Line

MAX

Filling Line

MAX

Filling Line

MAX

Filling Line

MAX

Top Plate

THE BURNER MUST BE COOL BEFORE REFILL!

Fill the Slimline Burner Fuel Tank to the Fill Line until the fuel becomes visible at the bottom of the Burner Vent. Fill using the Fuel Pump supplied (where applicable) or a funnel that fits in the centre hole of the Vent Plate. DO NOT OVERFILL

Please wipe any spillage or excess fuel before proceeding to Step 2.

DO NOT FILL WHILE OPERATING! [?]

DO NOT FILL WHEN HOT! [?]

2 - Igniting the Slimline Burner

Seal the fuel canister used to fill the Burner and move to a safe distance away from the Burner. While standing at arm's length away from the Burner, use a long arm lighter as per the image above to introduce a flame to the openings in the Vent Plate. If the Burner has fuel in the reservoir but is not igniting, close the Sliding Lid for 5 minutes then open the Sliding Lid. Ensure there are no flames visible within the burner vent opening, then pour a small amount of fuel across the length of the Burner Vent with the supplied plastic bottle (where applicable) and introduce the flame. This normally happens when the burner has been closed for a day or more.

Note: If fuel is left in the burner for a prolonged time or overnight, before next use, open the Vent for 2 minutes and let it air before ignition, to let the fuel vapour clear, and only then light.

3 - Adjusting the Flame Size

No Reducer

Small Reducer

Large Reducer

Large Reducer

Small Reducer

The flame intensity is adjusted by inserting the Sliding Lid Handle's tip into the corresponding holes in the Top Plate Sliding Lid as indicated above. Note the flame intensity takes a few minutes to change after an adjustment has been made. The Round Burner flame is adjusted by placing either the large or small reducer ring on top of the burner.

4 - Extinguishing the Flame

Using the Sliding Lid Handle, push the Sliding Lid to the front / closed position. Should the flame not extinguish with the first try please repeat until extinguished. It should be a swift action coupled with downward pressure.

For the Round Burner simply place the closing lid on top of the burner making sure it fits into its position.

Icon Fires Warranty Terms and Conditions

  1. All warranty claims are subject to manufacturer's review and acceptance.
  2. Icon Fires warrants that it uses reasonable care and skill to ensure that its products are of reasonable quality. Icon Fires will at it's cost and in it's sole discretion: (i) remedy any defect or fault in any product purchased; or (ii) replace any product in respect of which there is a defect or fault, during the warranty period, provided that written notice is given by the Purchaser to Icon Fires of any such defect or fault in the product as soon as the Purchaser becomes aware of that fault or defect. All warranty claims must be returned to Icon Fires for assessment with a receipt or other proof of payment. No warranty is given in respect of any glass contained in any product.
  3. Icon Fires has no liability to remedy any defect in a product or replace a product where the defect or fault is caused or contributed to by (i) the failure of the Purchaser to install the product according to specific installation instructions either supplied within each product box or carton or available on the Icon Fires website or through the retailer representative; or (ii) use of the product in a manner or for a purpose for which it was not designed.
  4. All site application or installation must reflect these procedures otherwise the product warranty will be considered void or will not take effect.

All products bearing the logo of Icon Fires logo is covered by a 2-year warranty.

IMPORTANT:

Models: BIO-70-210, Slimline Burner, BIO-70-210 Slimline Burner, Burner

File Info : application/pdf, 16 Pages, 1.40MB

icon fires slimline burner manual 20211220

References

Microsoft Word for Microsoft 365