Instruction Manual for TOOLOTS models including: RAD Series Refrigerated Air Dryer, RAD Series, RAD Series Air Dryer, Refrigerated Air Dryer, Air Dryer, Refrigerated Dryer, Dryer

RAD SERIES AIR DRYER MANUAL


File Info : application/pdf, 12 Pages, 823.71KB

PDF preview unavailable. Download the PDF instead.

RAD SERIES AIR DRYER MANUAL
Refrigerated Air Dryer Operation & Maintenance
Instruction

!

1!

Contents
------------------------------------------------------
Chapter 1: Device system flow .............................3 Chapter 2: Device installation and testing ..............4 Chapter 3: Device instructions ............................5
3.1 Device working conditions .......................5 3.2 Operation instructions .......................... 6 3.3 Notes ............................ ..................7 3.4 Daily maintenance of device .....................7 Chapter 4: Trouble-shootings of common fault ............8

Dear user, in order to use this equipment properly, please read this manual carefully and carry out the steps described in this manual strictly. If the equipment fails, please examine the equipment according to the troubleshooting list in this manual carefully, or contact agents authorized by our company, of dial our after-sale service hotline for assistance. If you maintain the equipment regularly, you will bring out its best performance. We hope that this product will facilitate your work and thank you very much for using this machine

!

2!

Chapter1: Device system flowchart

Saturated compressed air of higher temperature enters the pre-cooler of cold dryer to exchange heat with the cold dry air from evaporator and then enters the evaporated of refrigeration system when its temperature is reduced to exchange heat with cooling vapor for the second time to reduce its temperature to the evaporating temperature of cooling medium. During the two cooling courses, the water vapor in the compressed air is turned into liquid and flows into the vapor-liquid separator. The liquid separated in the separator is drained out of the equipment through automatic drainer (not charted). The compressed dry air of lower temperature enters the pre-cooler to exchange heat with the saturated air to increase its temperature and the compressed dry air of low moisture (dew point) and low relative humidity is obtained at the outlet. Pre-cooler, evaporator and vapor-liquid are the three major parts of the air flow system in cold dryer.

!

3!

Chapter 2: Device installation and testing

The following drawing shows the standard installation of the equipment. The C grade filter should be installed in principle to avoid the contamination on heat exchanger surface of refrigeration dryer caused by the unfiltered compressed air.
Notes:
Ø A clearance of no less than 1 meter should be left around the refrigeration dryer. Ø The refrigeration dryer can be installed without foundation, but the ground must be leveled. Ø T and A filters can be selected and fixed accordingly. Please refer to the user's manual of
filter for installation. Ø If this equipment is to be used together with piston compressor, a buffering gas container
should be installed before the refrigeration dryer to eliminate the effect of the pulsation of air source.
Warning
The power supply of refrigeration dryer shall be single phase 115V 60HZ or 230V 60HZ. In order to guarantee the proper operation, individual electrical cabinet conforming to the power requirements must be installed.

!

4!

Chapter 3: Instructions
3.1 Device working conditions

Power supply

Voltage115V 60HZ or 230V 60HZ Please refer to the nameplate for parameters as for special equipments

Rated 0.8 MPa0.6 MPa ~1.0 MPa Working pressure
Please refer to the nameplate for parameters as for high-pressure equipments

Inlet air temperature

Standard type: rated 38,maximum 45 High temperature type: rated65 maximum 80

Cooling water (Water cooling type)

water pressure0.2-0.5Mpa water inlet temperature31 water outlet temperature37 Water quality: neutral water with PH6.5~7.5, without observable solid
impurities

Environment

Environmental temperature Air cooling typeA238 Water cooling typeW245
Environmental humidity 80% Above sea level less than1000m Surroundings: no caustic fumes around Installation method: indoor (installation without base is allowed)

!

5!

3.2 Operating instructions

ACheck the following items before starting the device 1) All valves on the pipe network shall be at the ready-to-work condition pipe system: 2) Turn on the cooling water valve and maintain the pressure within 0.2--0.5MPa and the temperature below 31. 3) The indications of high-pressure gauge and low-pressure gauge of cooling medium on the panel are normal and approximately equal (note: there is only low-pressure gauge for small equipment) 4) Examine the power supply and make sure the rated value doesn't exceed ±10%. B If the above-mentioned items are normal, start the equipment. 5) Press the "start" button, and the cooling medium compressor will start thereafter: 6) Observe the panel, when the type of refrigerant is R22 the high pressure gauge of cooling medium should slowly increase to about 1.6MPa and the low pressure gauge of cooling medium should slowly reduce to about 0.4MPa. The equipment has now entered the normal working condition: Other common cooling medium shown in the following table:

Refrigerant Type
R134a R22 R410a

High pressure gauge of cooling medium (MPa) 1.1 1.6 2.3

Low pressure gauge of cooling medium (MPa) 0.2 0.4 0.7

7) First, start the dryer for 3~5 minutes; secondly, start the inlet air valve; finally, start the outlet air valve according to the load rate until it reaches the rated load.
8) Check the inlet/outlet pressure gauge (the difference of the two readings within 0.03MPa is acceptable)
9) Check the status of the automatic drainer. 10) Keep a record of the working condition of dryer, inlet/outlet air pressure, cooling medium
high pressure low pressure etc. 11) Stop steps: first, stop the outlet air valve; secondly, close the inlet air valve: and finally,
press the "stop" button.

!

6!

3.3 Notes
Please pay close attention to the following issues when using the refrigeration dryer: 1) Avoid long term operation without load. 2) Don't start the cooling medium compressor again and again and don't start over 6 times
within an hour. 3) In order to guarantee the air quality, please carrying out the start and stop steps strictly.
Start: run the dryer for 3~5minutes before starting the air compressor or inlet valve. Stop: turn off air compressor or outlet valve and then turn off the dryer. 4) Make sure the bypass valve connecting the inlet and outlet pipe is turned off in operation to avoid the unprocessed air flow into the low reach pipe network. 5) The air pressure shall not exceed 0.95MPa. (As for high-pressure equipment, please refer to the nameplate of the machine) 6) The inlet air temperature shall not exceed 45for standard type and 80 for high-temperature type. 7) The temperature of cooling water shall not exceed 31. 8) Don't start the equipment when the temperature is less than 2 9) The delay of the relay in the electrical control cabinet shall not be set less than 3 minutes. 10) Normally, only the start or stop button shall be used. 11) Wind-type refrigeration dryer cooling fan is controlled by pressure switch when the refrigeration dryer works in a low temperature environment, it is normal if the fan doesn't work. The fan will start automatically as the pressure of cooling medium increases.
3.4 Daily maintenance of device
ü Blow the dust, ash and fiber of the wind cooled condenser with compressed air regularly. ü Automatic drainer tends to be blockaded by pollutant in condensed water and please clean the
stainless-steel filter screen regularly by water or soap. ü Clean the water condenser regularly. ü Routine inspection: power supply, water supply and gas supply conditions. Observe and keep the
reading on the panel of the refrigeration dryer.

!

7!

Chapter 4: Trouble-shootings of common faults

The internal and external causes of faults of the desiccators are as follows. The causes and troubleshooting are presented here.
(1) Pressure drop increase

Cause analysis

Cause analysis

The pipe system valve is not open fully.

Fully open the valve

Too small diameters of pipes, too long pipe

Pipe system fault

length or too many elbows.

Redesign the piping system.

Pipe system filter blockage

Clean or replace the filter medium

Pipe system leakage

Decide the leaking point and fix it.

Condensed water frozen inside evaporator

Poor set or control of low-pressure switch
Fault or poor set valve of expansion valve and heated air bypass valve

Reset or replace the valve of low-pressure switch.
Reset or replace the valve

The air volume exceeds the rating volume of desiccators

Reduce the air flow
Replace air compressor or refrigeration desiccators

!

8!

(2) Refrigeration dryers start failure

Cause analysis

Corrective measures

Power supply system fault

External fault-line
Fuse burning or air switch tripping

Find out the cause and treat accordingly to restore power supply
Find out the cause and treat accordingly to restore power supply

Voltage abnormality

The voltage shall be 115V±10% or 230V±10%

Start failure with proper power supply

Control circuit fault Control circuit fault Poor electric contact Reset failure after protection
system tripping

Compressor fault

Internal MP action of compressor

Replace with a new one Find out the cause and treat accordingly
Fix or replace with a new one Find out the cause of tripping, treat
accordingly and then reset Check the compressor and treat
accordingly
Reset when the compressor gets cool

(3) Poor automatic drain system Cause analysis

Corrective measures

Working pressure is lower than 0.15Mpa

Proper working pressure of automatic water drainer is within 0.2~1.0Mpa

Drain failure or poor drain

Filter screen blockage in water drainer
The preceding ball valve of water drainer is not opened

Drainpipe blockage

Clean the filter screen Open the filter screen
Clean the pipe

Draw off valve damage

Replace the float ball inside water drainer or replace the water drainer

!

9!

(4) Poor drainage Cause Analysis

Corrective measures

Bypass valve fails to close or to be closed fully

Close the bypass valve

The air doesn't pass through the dryer

Poor installation and

piping system

The dryer is not leveled in

installation

Loped automatic drainer

Open the inlet valve Horizontalization Horizontalization

The drainage system is higher than automatic drainer

Redesign the drainage pipe system

Ball valve of drainer fails to open
Poor drain system

Open the ball valve

Water drainer blockage of damage
Too high cooling medium condensing pressure

Clean or replace drainer
Adjust the water flow governing valve, expansion valve, hot-gas bypass valve or
pressure switch

Cooling medium Too high air inlet temperature
system fault

Add a rear condenser

Cooling medium leakage Compressor fault

Decide the leakage, fix the leakage, and refill cooling medium
Check the compressor

!

10!

(5) Bad working performance with proper operation of dryer

Cause analysis

Corrective measures

Too low indication value of cooling medium evaporating
pressure gauge

Cooling medium leakage
Cooling medium pipe blockage
Expansion valve or hot-gas bypass valve fault

Decide & fix the leakage & refill cooling medium
Replace cooling medium desiccant, vacuumize and refill cooling medium
Reset or replace the valve

Poor evaporating pressure gauge Too low cooling water temperature
Too high air inlet temperature

Replace it
Reduce the cooling water flow
Install rear condenser to reduce atmospheric temperature

Too high indication valve of cooling medium evaporating
pressure gauge
Too high indication valve of cooling medium condensing pressure gauge

Expansion valve or hot-gas bypass valve fault

Reset or replace the valve

Condenser blockage

Clean the condenser

Too high cooling water temperature

Improve the cooling water temperature

Cooling medium compressor fault Check compressor and treat accordingly

Cooling medium pipe blockage
Condenser scaling or blockage
Too high cooling water temperature or too small
water flow
Pressure gauge damage

Check pipe system and treat accordingly
Clean the condenser Adjust the water flow governing valve preset valve to improve cooling water
conditions Replace the pressure gauge

Pressure gauge damage Check compressor and treat accordingly

Too high air inlet temperature

Install rear condenser

Overload running

Too much air process capacity Reduce the load or replace the device

Cooling medium leakage

Decide the leakage, fix it and refill cooling medium

!

11!

(6) Bad operation of compressor after starting

Cause analysis

Corrective measures

Voltage abnormality

Trip soon after start

Find out the fault and treat accordingly

Start failure with proper electric system

Poor contact of cooling medium pressure switch
Overload tripping caused by too large load

Replace pressure switch Decrease the load and restart

Condenser scaling or blockage

Clean the condenser

Poor oil pressure switch or oil pressure failure

Adjust of replace with a new one

Compressor overload

Reduce the air process flow

Air inlet temperature too high

Install rear condenser to reduce temperature

Frequent tripping of Poor environment ventilation and too Take measures to improve

overload relay

high temperature

environment conditions

Too low preset values of overload relay

Set the value again

Take measures to bring down the Too high cooling water temperature
water temperature

!

12!

