Instructions for glooko models including: GTM400, 2ACSCGTM400, Transmitter
Glooko, Inc. GTM400 Diabetes patient data transmitter 2ACSCGTM400 2ACSCGTM400 gtm400
Glooko, Inc. GTM400 2ACSCGTM400 2ACSCGTM400 gtm400
File Info : application/pdf, 20 Pages, 5.62MB
DocumentDocumentGlooko Transmitter Instructions for use for Glooko users 2 Contents Find your device..........................................................................................4-5 General Information.......................................................................................6 Product description..............................................................................................................................................................................6 About Glooko..........................................................................................................................................................................................6 Intended use...........................................................................................................................................................................................6 Warnings..................................................................................................................................................................................................6 Getting Started...............................................................................................7 Quick Tips.......................................................................................................7 Setup of Glooko Transmitter.........................................................................8 Setup without a cable box...................................................................................................................................................................8 Setup with cable box.............................................................................................................................................................................8 Connect a diabetes device...................................................................................................................................................................9 Upload data............................................................................................................................................................................................9 Additional Information................................................................................10 Ethernet setup......................................................................................................................................................................................10 Compatible Devices and Transmission Methods........................................11 3 Find your device Abbott FreeStyle Freedom Lite................................................................11 FreeStyle InsuLinx .........................................................................11 FreeStyle Lite...................................................................................11 FreeStyle Optium Neo..................................................................11 FreeStyle Precision Neo...............................................................11 Precision Xtra...................................................................................11 Precision Xceed...............................................................................11 Abbott FreeStyle Libre.................................................................................11 Acon Laboratories On Call® Advanced.........................................................................11 On Call® Express.............................................................................11 On Call® Express II..........................................................................11 On Call® Express Voice..................................................................11 On Call® Plus.....................................................................................11 On Call® Resolve.............................................................................11 On Call® Vivid...................................................................................11 AgaMatrix WaveSense JazzTM..........................................................................12 Glucose meter CGM Insulin pump Insulin pen Contour Next Link..........................................................................12 Contour Next Link 2.4...................................................................12 Contour Next USB..........................................................................12 Contour Plus....................................................................................12 Contour Plus Blue..........................................................................12 Contour Plus Elite...........................................................................12 Contour Plus One...........................................................................12 Contour TS........................................................................................12 Contour USB....................................................................................12 Contour XT........................................................................................12 Beurer GL50 evo............................................................................................12 Beurer GL 44.....................................................................................12 Beurer GL 48.....................................................................................12 Beurer GL 49.....................................................................................12 Bionime GE100.................................................................................................13 Bioseven lineaD ORO.......................................................................................13 Animas OneTouch Ping (meter)................................................................12 Animas OneTouch Ping (pump)................................................................17 Vibe......................................................................................................17 Vibe Plus............................................................................................17 Arkray GlucoCard 01...................................................................................12 GlucoCard Expression..................................................................12 GlucoCard Shine.............................................................................12 GlucoCard Vital...............................................................................12 GlucoCard Shine Connex ...........................................................12 GlucoCard Shine Express ...........................................................12 GlucoCard Shine XL ......................................................................12 ReliOn Confirm................................................................................12 ReliOn Premier Blu.........................................................................12 ReliOn Premier Classic.................................................................12 ReliOn Premier Voice....................................................................12 ReliOn Prime....................................................................................12 Ascensia (Bayer) Breeze 2.............................................................................................12 Contour..............................................................................................12 Contour Care....................................................................................12 Contour Fit........................................................................................12 Contour Link.....................................................................................12 Contour Next...................................................................................12 Contour Next (Bluetooth)............................................................12 4 Contour Next One..........................................................................12 Contour Next EZ.............................................................................12 Dexcom G4 Platinum......................................................................................16 G4 Platinum with S hare...............................................................16 G5.........................................................................................................16 Touchscreen Receiver (G5/G6)..................................................16 Equil/Wellion MICRO-pump...................................................................................17 ForaCare FORA 6 Connect.........................................................................16 Diamond Mini DM30......................................................................16 ForaCare Fora GD40......................................................................16 GlucoRx HCT......................................................................................................13 Nexus..................................................................................................13 Nexus Mini.........................................................................................13 Q...........................................................................................................13 i-SENS Alphacheck Professional ............................................................13 CareSens BGM/TEE2.....................................................................13 CareSens Dual.................................................................................13 CareSens N.......................................................................................13 CareSens N POP.............................................................................13 CareSens N Voice...........................................................................13 CareSens N Premier......................................................................13 No Coding Plus................................................................................13 TEE2+..................................................................................................13 iCare Palmdoc II.........................................................................................13 Infopia Fintetest Lite....................................................................................13 GlucoLab...........................................................................................13 Insulet Omnipod® System.........................................................................17 Omnipod® DashTM System...........................................................17 Intuity POGO® AutomaticTM.......................................................................13 LifeScan OneTouch Select Plus...................................................................13 OneTouch Ultra...............................................................................13 OneTouch Ultra2............................................................................13 OneTouch UltraEasy.....................................................................13 OneTouch UltraMini......................................................................13 OneTouch Ultra Plus Reflect.......................................................13 OneTouch Verio ..............................................................................13 OneTouch Verio Flex......................................................................13 OneTouch Verio IQ.........................................................................13 OneTouch Verio Reflect................................................................13 OneTouch Verio Sync....................................................................13 Medtronic 630G...............................................................................................17 640G....................................................................................................17 670G....................................................................................................17 Menarini GLUCOCARD G+.........................................................................14 GLUCOCARD SM.............................................................................14 GlucoFix Tech..................................................................................14 Glucomen areo...............................................................................14 Glucomen areo 2K.........................................................................14 Glucomen LX2.................................................................................14 Nipro 4SURE Smart ...................................................................................14 4SURE Smart Duo..........................................................................14 NovoNordisk NovoPen® 6......................................................................................19 NovoPen Echo® Plus.....................................................................19 Prodigy AutoCode..........................................................................................14 Roche Accu-Chek Active...........................................................................14 Accu-Chek Aviva Combo.............................................................15 Accu-Chek Aviva Connect...........................................................14 Accu-Chek Aviva Expert...............................................................15 Accu-Chek Aviva Insight...............................................................19 Accu-Chek Aviva Nano.................................................................15 Accu-Chek Aviva Plus Black........................................................15 Accu-Chek Aviva Plus Silver........................................................15 Accu-Chek Compact.....................................................................15 Accu-Chek Compact Plus...........................................................15 Accu-Chek Guide............................................................................14 Accu-Chek Guide Me ....................................................................14 Accu-Chek Instant..........................................................................14 Accu-Chek instant S......................................................................14 Accu-Chek Mobile (USB)..............................................................14 Accu-Chek Nano.............................................................................15 Accu-Chek Performa.....................................................................15 Accu-Chek Performa Connect..................................................14 Accu-Chek Performa Insight......................................................18 Accu-Chek Performa Nano.........................................................15 Accu-Chek Spirit Combo.............................................................18 Roche Accu-Chek Aviva Insight...............................................................18 Accu-Chek Performa Insight......................................................18 Accu-Chek Solo..............................................................................17 Sanofi BGStar................................................................................................14 MyStar Extra.....................................................................................14 Tandem t:flex..................................................................................................... 17 t:slim...................................................................................................17 t:slim X2..............................................................................................17 t:slim G4.............................................................................................17 Terumo Medisafe Fit Smile..........................................................................16 Terumo Medisafe WITH................................................................................19 Trividia (Nipro) TRUE METRIX ..................................................................................14 TRUE METRIX AIR............................................................................14 TRUEresult........................................................................................14 TRUEyou mini..................................................................................14 Wellion Calla Light.........................................................................................14 Calla Mini...........................................................................................14 Galileo GLU/KET.........................................................................14 Leonardo GLU/KET...................................................................14 Ypsomed Mylife Aveo........................................................................................14 5 General information Product description Glooko Transmitter is indicated for use by health care professionals in health care facilities to transfer predefined data from home monitoring devices to a server database. About Glooko Glooko offers health care providers an online solution that collects and stores all their diabetes patients' data centrally, without worrying about any software installation. No matter if the device transmits using a cable or infrared connection, all uploaded information will immediately be shown online in a secure Glooko account. All data from multiple devices will be consolidated and presented in one report. Intended use Glooko is a data management software intended for use in home and professional settings to aid individuals with diabetes and their healthcare professionals in review, analysis, and evaluation of device data to support an effective diabetes management program. Glooko connects to compatible medical devices and trackers to allow users to transfer their data to the Glooko system. Glooko is not intended to provide treatment decisions or to be used as a substitute for professional healthcare advice. Warning! Glooko does not measure, interpret, or make decisions on the data it conveys nor is it intended to provide automated treatment decisions or be used as a substitute for professional judgment. All medical diagnosis and treatment are to be performed under the supervision and oversight of an appropriate healthcare provider. All patient medical diagnoses and treatments are to be performed under supervision of qualified healthcare professionals! Glooko is not intended to provide automated treatment decisions or to be used as a substitute for professional healthcare judgment. Glooko is not intended for emergency calls or for transmission or indication of any real-time alarms or time-critical data! Glooko is not intended as a substitute for direct medical supervision or emergency intervention. 6 Getting started You will need: 1. A compatible blood glucose meter, insulin pen, insulin pump or continuous glucose monitor (CGM); 2. Glooko Transmitter; 3. A Glooko account with Population Tracker access; 4. The device upload cable specific to the diabetes device. Please note that Glooko does not provide these cables. If you are missing a specific cable, please contact the device manufacturer. Quick Tips · No network connection? Try moving the Glooko Transmitter to a new location within your clinic keeping cellular network reception in mind. · Device isn't uploading? Verify that the Glooko Transmitter displays "Ready to transfer" before connecting your diabetes device. NFC contact area Antenna LCD Display Ethernet port Kensington security slot Infrared (IR) window USB port * The Micro-HDMI port is disabled. Micro-HDMI port* USB port DC power input 7 Setup of Glooko Transmitter Setup without a cable box 1A Connect Glooko Transmitter 2A Start up 1. Connect the power supply, as shown above, and plug it into a power outlet. 1. Follow the on-screen instructions to complete the setup. 2. "Ready to transfer" will be displayed when setup is done. Setup with a cable box 1B Connect Glooko Transmitter and USB Hub 2B Start up 1. Place the USB hub inside the Cable box. 2. Connect the USB hub to Glooko Transmitter (using the USB cable) and plug its power supply into a power outlet. 3. Place Glooko Transmitter on top of the Cable box. Connect its power supply, as shown above, and plug it into a power outlet. 1. Follow the on-screen instructions to complete the setup. 2. "Ready to transfer" will be displayed when setup is done. 8 i Note: If you want to connect Glooko Transmitter to the Internet using Ethernet (instead of the built-in cellular connection). Plug in the Ethernet cable and Glooko Transmitter will configure itself. For further instructions see page 10. 3 Connect a diabetes device IR 4 Upload data Each diabetes device connects in one of the following manners: · USB cable (USB port or USB hub) · Infrared (built-in IR receiver or for some devices a SmartPix cable). · NFC (Near field communication) · BLE (Bluetooth Low Energy) Follow the specific instructions on how to upload all compatible diabetes devices on page 11-19. Your transfer is complete when your screen turns green. 5 Sign in to your Glooko account Go to https://my.glooko.com to sign in to your Population Tracker. Navigate to the Assign Devices tab to retrieve the uploaded data. i For more information about using Glooko Transmitter, please refer to the: Glooko for clinics - Quick Start Guide at https://support.glooko.com 9 Additional information If an update is ready, you can choose to restart immediately. Otherwise Glooko Transmitter will update automatically after 10 hours. If the upload process was unsuccessful you will be notified. Please follow the on-screen instructions. More functions are available by tapping the menu icon. Transfer Bluetooth devices Open Glooko Transmitter menu by tapping the menu icon. Select "Transfer Bluetooth device". Select the device you want to transfer and follow the on-screen instructions. Ethernet setup When connecting an Ethernet cable, Glooko Transmitter will automatically try to connect to the Internet via Ethernet. If you want to configure the Ethernet connection manually or read the MAC address, please go to: Menu > Settings > Network settings > Ethernet settings If the configured Ethernet network is not available, Glooko Transmitter will automatically revert to cellular connection. 10 Compatible devices and transmission methods Below are instructions on how to upload diabetes data from a compatible device using Glooko Transmitter. Unless explicit upload instructions are provided for the device, you simply need to connect it to the Transmitter or USB hub with its specific USB cable or via IR, Bluetooth or NFC and it will upload automatically. You will need a Glooko account with Population Tracker access. The data uploaded using Glooko Transmitter will synchronize with your Population Tracker account, which can be accessed with your Glooko professional account login information. Internet (cellular network or Ethernet connection) is necessary for the uploaded data to synchronize to the Glooko server. i Glooko Transmitter uploads glucose data from the meters, insulin pumps, and CGMs listed below. Please note that some of the diabetes devices may not be available in your market. Glucose meters and CGMs - connected with USB cable i Note: If you have a USB hub connected to Glooko Transmitter, the USB hub must be powered by its own power supply. Abbott FreeStyle Freedom Lite FreeStyle Lite FreeStyle InsuLinx FreeStyle Libre* FreeStyle Precision Neo FreeStyle Optium Neo Abbott FreeStyle USB cable (2.5 mm) Micro USB Precision Xceed Precision Xtra Abbott Xceed USB cable *Compatibility for FreeStyle Libre is restricted to Sweden and Norway by Abbott. FreeStyle Libre 2 is currently not compatible. Acon Laboratories On Call® Advanced On Call® Resolve On Call® Plus On Call® Vivid On Call® Express On Call® Express II On Call® Express Voice On Call USB cable (2.5 mm) On Call USB cable (2.5 mm) On Call USB cable (2.5 mm) Connect and press the meter's M and S buttons. Connect and press and hold the meter's S button. 11 Glucose meters and CGMs - connected with USB cable Continued from previous page AgaMatrix WaveSense JazzTM AgaMatrix USB cable Animas OneTouch Ping (meter) Mini USB Connect and press the meter's power button. Arkray Glucocard 01 Glucocard Vital Relion Confirm Relion Prime Arkray USB cable (2.5 mm) Glucocard Shine Glucocard Shine XL i-Sens USB cable (2.5 mm) Glucocard Shine Connex Glucocard Shine Express Micro USB Glucocard Expression Medcore Care + GlucoCard Expression USB cable (3.5 mm) ReliOn Premier Blu (BLE) ReliOn Premier Voice ReliOn Premier Classic i-Sens USB cable (2,5 mm) Ascensia (Bayer) Breeze 2 Contour Plus Contour Contour Link Contour Next EZ Contour TS Contour XT Bayer's blue USB cable (3.5 mm) Bayer's blue USB cable (3.5 mm) Connect and press any button. Connect and select PC Link in the main menu on the meter. Connect and press the meter's power button. Connect and press the meter's M button. Contour Next Link Contour Next USB Contour Next Link 2.4 Contour USB USB port on meter Contour Care Contour Fit Contour Next Contour Next (Bluetooth) Contour Next one Contour Plus one Contour Plus Blue Contour Plus Elite Micro USB Beurer GL50 evo USB port on meter GL 44 12 GL 48 GL 49 Micro USB Glucose meters and CGMs - connected with USB cable Continued from previous page Bionime GE100 Bionime (Pura + Rightest) USB Bioseven lineaD ORO GlucoRx HCT Nexus Nexus Mini Q Bioseven USB (2,5 mm) Mini USB iCare PalmDoc II i-SENS Alphacheck Professional CareSens BGM/Tee2 CareSens Dual CareSens N CareSens N POP CareSens N Premier CareSens N Voice CareSens TEE2+ No Coding Plus Mini USB Mini USB i-Sens USB (2,5 mm) Infopia Finetest Lite GlucoLab Infopia USB (2,5 mm) Intuity POGO® AutomaticTM Micro USB LifeScan OneTouch Ultra OneTouch Ultra2 OneTouch UltraEasy OneTouch UltraMini LifeScan USB (3.5 mm) OneTouch Select Plus OneTouch Verio Flex OneTouch Ultra Plus Reflect OneTouch Verio Reflect OneTouch Verio Micro USB OneTouch Verio IQ OneTouch Verio Sync Mini USB Connect and press the meter's power button. Connect then push the meter's S button (C button). Connect and press any button. 13 Glucose meters and CGMs - connected with USB cable Continued from previous page Menarini GLUCOCARD SM Micro USB GLUCOCARD G+ GlucoMen LX2 GlucoMen areo GlucoMen areo 2K GlucoFix Tech Menarini white USB (3,5 mm) Menarini blue USB (3.5 mm) Menarini GlucoMen areo USB (2,5 mm) If the meter displays: E-3, disconnect it wait until the display is off, then connect the meter again. Nipro 4SURE Smart 4SURE Smart Duo Micro USB Trividia (Nipro) TRUE METRIX TRUE METRIX AIR TRUEresult TRUEyou mini Nipro TRUEresult USB docking station Connect and place the meter in the docking station. Prodigy AutoCode Mini USB Roche Accu-Chek Active Aviva Connect Performa Connect Guide Guide Me Instant Instanst S Mobile (USB) Micro USB Once connected, upload should start within 20 seconds after connecting the cable. If not, go to the main menu on the meter. Go to My data > Data Transfer > Reports, and connect the meter to the USB cable again. (Please do not hold down the two arrow buttons.) Sanofi BGStar Wellion Calla Light Calla Mini MyStar Extra Sanofi USB cable Galileo GLU/KET Leonardo GLU/KET Wellion Calla mini USB Ypsomed Mylife Aveo 14 Micro USB Blood glucose meters - with infrared connection IR window on Glooko Transmitter Set the meter in upload mode by following the instructions below. Place the glucose meter's top end directed towards the IR window on Glooko Transmitter. i Please make sure to keep the device completely still during the upload. Do not remove the device until the screen displays: Transfer complete! Roche Accu-Chek Aviva Nano Aviva Plus Black Aviva Plus Silver Nano Performa Performa Nano Aviva Combo Aviva Expert With the meter off, activate IR transmission by pressing and holding the two arrow buttons until two arrows appear in the display. In the main menu, go to My data and select Data transfer. Compact Compact Plus Activate IR transmission by pressing and holding the meter's two topmost buttons until two arrows appear in the display. Activate IR transmission by pressing and holding the buttons S and M below the display until two arrows appear in the display. 15 Glucose meters & CGMs - connected with Bluetooth or NFC ForaCare FORA 6 Connect FORA Diamond MINI DM30 FORA GD40h Terumo Medisafe Fit Smile Please see the instructions regarding transferring Bluetooth devices on page 10. Place the glucose meter on the NFC pad on top of Glooko Transmitter and follow the on-screen instructions. CGMs - connected with USB cable i Note: If you have a USB hub connected to Glooko Transmitter, the USB hub must be powered by its own power supply. Dexcom G4 Platinum G4 Platinum with Share G5 Touchscreen Receiver (G5/G6) 16 Micro USB If the upload doesn't start, disconnect the receiver, select Shutdown in the menu to turn the receiver off. Turn the receiver on again and connect it to Glooko transmitter. Insulin pumps - connected with standard USB cable i Note: If you have a USB hub connected to Glooko Transmitter, the USB hub must be powered by its own power supply. Equil/Wellion MICRO-pump Insulet Omnipod® DashTM System Omnipod® System Micro USB Micro USB Mini USB 1. Plug DASHTM into Transmitter with the USB-A to Micro cable. 2. Tap Export on DASHTM. 3. Unplug DASHTM, and plug it back in. 4.Once the upload is complete, Glooko Transmitter will display Transfer Complete. Medtronic 630G 640G 670G USB port on meter 1. Connect a Contour Next Link 2.4 meter to Glooko Transmitter. 2. Follow the on-screen instructions to upload data from your Medtronic pump. Roche Accu-Chek Solo Tandem t:flex t:slim t:slim X2 t:slim G4 Micro USB Micro USB 1.Open the Main Menu on the hand unit for the pump. 2. Select USB in the Main Menu. 3.Connect the hand unit to Glooko Transmitter with the Micro USB cable. Insulin pumps - with infrared connection i For the Animas pumps, please make sure the pump is suspended and the screen is illuminated when transmission begins. The screen does not need to remain illuminated during the full transmission. Keep the pump completely still, and do not remove the pump until the screen displays: Transfer complete! IR window on Glooko Transmitter Animas OneTouch Ping (pump) Vibe Vibe Plus 1. Suspend the pump. (MAIN MENU, scroll to Suspnd/Resum and press OK; Suspend is highlighted). 2. Press OK. 3. Place the pump with its back towards the IR window on the Transmitter. 4. When the transmission is finished: Resume pump (MAIN MENU, scroll to Suspnd/Resum and press OK; Resume is highlighted). Press OK. 17 Insulin pumps - connected with infrared cables Compatible infrared cables Roche Accu-Chek Smart Pix cable Roche Accu-Chek Smart Pix 2 cable Roche Accu-Chek Aviva Insight Accu-Chek Performa Insight Smart Pix 2 Note! Connect the handset of your pump with a micro USB cable to the Smart Pix 2. 1. Connect the Smart Pix 2 cable to Glooko Transmitter and wait for the blue indicator on the Smart Pix 2 to start flashing slowly. 2. Connect the handset to the Smart Pix 2 with a micro USB cable. 3. In the handset menu select Connect to PC and press OK. 4. Ensure that the pump is within reach of the handset. 5. The blue indicator on the Smart Pix 2 is on while the data is being transmitted from the device to the Smart Pix 2. 6. The blue indicator turns itself off and both Smart Pix 2 and device emit a sound to signal that the data is being transmitted from the Smart Pix 2 to Glooko Transmitter. Do not disconnect the Smart Pix 2 yet! 7. Wait for Glooko Transmitter to confirm the upload was successful. Roche Accu-Chek Spirit Combo 18 IR Smart Pix or Smart Pix 2 Note! Smart Pix software version 3.02 or higher is required when using Smart Pix. 1. Connect the Smart Pix to Glooko Transmitter and wait for the blue indicator on the Smart Pix to start flashing slowly. 2. Put the pump in Data Transfer Mode (stop the pump and enter the Data Transfer Menu). 3. Place the pump with its IR window towards the Smart Pix. The blue indicator signals the data is being transmitted to the Smart Pix. 4. Wait for the blue indicator to start flashing slowly again or stop flashing altogether. 5. The data is now being transmitted from the Smart Pix to Glooko Transmitter. Do not disconnect the Smart Pix yet! 6. Wait for Glooko Transmitter to confirm the upload was successful. Insulin pumps - connected with NFC NFC pad Terumo Medisafe WITH 1. Make sure the main menu is showing on the remote control for the pump. 2.Place the remote control on the NFC pad on top of Glooko Transmitter and follow the on-screen instructions. Please note that the transmission symbol on the back of the remote control needs to be aligned with the center of the NFC pad on Glooko Transmitter. Insulin pens - connected with NFC NFC pad NovoNordisk NovoPen® 6 NovoPen Echo® Plus Place the connected pen on the NFC pad on top of Glooko Transmitter and follow the on-screen instructions. 19 Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC RF Radiation Exposure Statement Caution: To maintain compliance with the FCC's RF exposure guidelines, place the product at least 20 cm from nearby persons. The following information applies to Glooko Transmitters with serial numbers starting with 21 (e.g. S21XXXXXX) or lower (e.g. S20XXXXXX, S19XXXXXX, etc.). Technical specifications Enclosure protection GSM/GPRS IP20 Indoor use only 850/900/1800/1900 MHz Operating temperature UMTS/HSPA Power supply 5 °C to 40 °C 850/900/1900/2100 MHz Input: 100240V AC, 0.6A, 50/60 Hz Output: 12V DC, 2.0A, LPS Glooko AB Nellickevägen 20 SE-412 63 Göteborg SWEDEN Glooko Inc 411 High Street Palo Alto, CA 94301 USA Support support@glooko.com https://support.glooko.com 1-800-206-6601 The following information applies to Glooko Transmitters with serial numbers starting with 22 (e.g. S22XXXXXX) or higher (e.g. S23XXXXXX, S24XXXXXX, etc.). Technical specifications Enclosure protection CE FCC Operating temperature UMTS/HSPA Power supply IP20 Indoor use only GSM : 900/1800 MHz WCDMA: Band I/VIII LTE: Band 1/8 GSM : 850/1900 MHz WCDMA: Band II/V LTE: Band 2/4/5/12 5 °C to 40 °C 850/900/1900/2100 MHz Input: 100240V AC, 0.6A, 50/60 Hz Output: 12V DC, 2.0A, LPS Glooko Inc 411 High Street Palo Alto, CA 94301 USA Glooko AB Nellickevägen 20 SE-412 63 Göteborg SWEDEN Support support@glooko.com https://support.glooko.com 1-800-206-6601 IFU-0038-00-EN 22 Glooko Transmitter for Glooko Users www.glooko.com © 2022 Glooko Inc.