User Manual for emitec models including: ELECTRA-T16, 16 Port Gigabit Layer2 Managed PoE Switch, ELECTRA-T16 16 Port Gigabit Layer2 Managed PoE Switch, Gigabit Layer2 Managed PoE Switch, Layer2 Managed PoE Switch, Managed PoE Switch, PoE Switch, Switch
ELECTRA-T16 is managed PoE switch designed for security transmission and WIFI coverage. It can meet the POE power supply requirements of WIFI AP, ...
Product Introduction Sample Clauses | Law Insider
File Info : application/pdf, 18 Pages, 751.53KB
DocumentDocumentUser Manual ELECTRA-T16 16 Port Gigabit Layer2 Managed PoE Switch Installation manual introduction The Product installation manual mainly describes ELECTRA-T16 PoE switch hardware features, installation methods, and precautions during the installation This manual includes the following chapters: Chapter 1: Product Introduction. Briefly describes the basic features of the switch and the appearance details. Chapter 2: Product Installation. Guide the switch hardware installation methods and precautions. Chapter 3: Hardware Connections. Guide the connection between switches and other devices and precautions. Chapter 4: Technical Specifications. NOTE:To avoid potential device damage and personal injury, read the related information in this manual before installing the device. Agreement The term "switch" mentioned in this manual, unless otherwise specified, refers to 16port full Gigabit managed PoE switch, hereinafter referred to as ELECTRA-T16 . Some pictures for the schematic, the product itself and pictures may be different The contents of this document may be updated from time to time due to product version upgrades or other reasons. Unless otherwise agreed, this document is provided as a guide only, and all statements, information and recommendations in this document do not constitute any form of warranty. This icon indicates the items to be cautioned in the operation. If the operation is wrong, the equipment may be damaged and other adverse consequences. Chapter 1 Product Introduction 1.1Product Introduction ELECTRA-T16 is managed PoE switch designed for security transmission and WIFI coverage. It can meet the POE power supply requirements of WIFI AP, IP camera, WIFI bridge, IP phone and other types of equipment. The product adopts a new generation of high-performance hardware and software platform to provide flexible, cost-effective access and Gigabit uplink ports, complete security protection mechanism, complete ACL/QoS policy and rich VLAN functions, easy to manage and maintain, and meet users' requirements for network equipment easy to manage, high security and low-cost , it is applicable to network access, aggregation, and core application scenarios of campus, hotel, and enterprise campus. PoE (Power over Ethernet) refers to the power over Ethernet technology. It refers to the transmission of data signals to some IP-based terminals (such as IP phones, wireless access point APs, network cameras, etc.) and also provide DC power supply technology.These devices that accept DC power supply are called powered devices (PD, Powered Device) 1.2Packing List Open the package and check the list below Commodity PoE switch Power cord Bracket User manual Quantity 1pcs 1pcs 2pcs 1 pcs Description No Optional Fixed on rack mount Guide users to install switch 1.3Appearance Front Panel Including indicators, RJ45 port, shortcut buttons, RST button, SFP port, CONSOLE port, as shown in Figure 1.1 below Indicators ELECTRA-T16 The indicator working status is shown as the following table Indicator PWR POE LINK/ACT SYS Title Power indicator color red Work state Solid off POE power indicator yello w solid off Connection indicator System indicator gree n gree n Blinking off Blinking off Description Power is normal No power, the power switch is not turned on, power supply is abnormal The corresponding RJ45 port is connected to the powered device and the power supply is normal The corresponding RJ45 port is not connected to the powered device or the power supply is abnormal A valid link is established An invalid link is established System is functioning properly System is functioning improperly Software is damaged DIP switch function AI QOS: Improve video data processing capabilities and improve the monitoring of Caton and Mosaic phenomena in the network AI Extend: 1-8 port rate down to 10Mbps, but the transmission distance up to 250 meters AI VLAN: Isolating ports 1-16 from each other, suppress network storms effectively and improve network performance AI power supply: Detect PD, power failure and restart dead equipment RJ45 Port ELECTRA-T16 supports 16 10/100/1000 Mbps ports, both supporting IEEE802.3af and IEEE802.3at standard POE power supply. SFP Port ELECTRA-T16 provides 2 Gigabit SFP optical module expansion slots (17, 18) for plugging Gigabit SFP modules RST Button When the switch is powered on, press the button with needle and release the device to enter the restart state. When the SYS light is turned on again, the device restarts. When the switch is powered on, press the button for 5 seconds or more to release the button device to enter the reset status, when SYS lights up again, the device resets successfully. Console Port The Console port is used for connecting to the serial port of a computer or other terminal to manage or configure the switch. Back Panel Includes: power socket, ground Power socket The power supply to the switch ELECTRA-T16 should be 100-240V~ 50/60Hz AC power. Ground terminal Please use a wire to ground so that preventing lightning strikes. To avoid product lightning strikes and extend the life of the product Chapter 2 Product Installation 2.1 Installation Precautions Note: To avoid damage to the equipment and personal injury caused by improper use, please observe the following precautions. Installation safety precautions The power is kept off during the installation process. Wear an ESDpreventive wrist strap and ensure that the ESD-preventive wrist strap is in good touch with the skin to avoid potential safety hazards. The switch can work normally under the correct power supply. Please confirm that the power supply voltage matches the voltage indicated by the switch. Before powering on the switch, please make sure that the power circuit is not overloaded, so as not to affect the normal operation of the switch and even cause unnecessary damage To avoid the risk of electric shock, do not open the case while the switch is working, even if it is not charged, do not open it by yourself. Before cleaning the switch, pull out the power plug of the switch. Do not wipe with a moist fabric. Do not use liquid to clean. Temperature and humidity In order to ensure long-term stable operation of the switch and prolong its service life, please maintain a certain temperature and humidity in the environment. Excessively high or too low ambient humidity may cause leakage, deformation or even corrosion of metal parts. If the temperature is too high, the aging process of the insulation material will be accelerated, which will seriously affect the service life of the equipment. Normal operation and storage temperature / humidity of this series of switches As below Environmental description Working Environment Storage environment Temperature 0~40 -4070 Altitude Relative humidity 10%90% RH Noncondensing 5%90% RH Noncondensing Products with this mark are only suitable for safe use in areas below 2000m. Dust-proof Dust falling on the surface of the switch can cause electrostatic adsorption and poor contact of the metal contacts. Although the device itself has made certain measures in anti-static, when the static electricity exceeds a certain strength, it will still cause fatal damage to the electronic components on the internal circuit board. To avoid the static electricity affecting the normal operation of the device, please pay attention to the following: Regular dust removal to keep indoor air clean; Confirm that the equipment is well grounded to ensure the smooth transfer of static electricity Electromagnetic interference Electromagnetic interference will affect the internal components such as capacitance, inductance and other electronic components by capacitive coupling, inductive coupling, impedance coupling, etc. To reduce the adverse effects caused by electromagnetic interference, please pay attention to the following: The power supply system takes necessary measures against grid interference; The switch should be away from high-frequency, high-power, high-current equipment, such as wireless transmitters; Take electromagnetic shielding measures when necessary Lightning protection needs When a lightning strike occurs, a strong current is generated in an instant, and the air in the discharge path is instantaneously heated to 20,000 degrees Celsius, and an instantaneous large current is enough to cause fatal damage to the electronic device. For better lightning protection, please note the following: Confirm that the rack is in good contact with the ground; Make sure the power outlet is in good contact with the ground; Reasonable wiring to avoid internal induction lightning; Signal lightning protector is recommended for outdoor wiring Installation station requirements Regardless of whether the switch is installed in a rack or on another horizontal workbench, be aware of the following: Make sure the rack or workbench is stable, strong, and can withstand at least 5.5Kg weight; Make sure the rack has a good cooling system, or maintain good indoor ventilation; Make sure the rack is well grounded, the power outlet and switch are within 1.5 meters Prepare tools for installation You may need to use a screwdriver during installation, electrostatic wrist strap, fiber optic cable and other tools to prepare yourself 2.2 Product installation 19-inch standard rack installation PS1016S is designed according to the standard 19-inch rack size, you can easily install to the rack, the specific installation steps are as follows: 1) Check rack grounding and stability 2) Install the two L-brackets in the accessory on each side of the switch panel and secure with the screws provided in the accessory 3) place the switch in an appropriate place in the rack and be supported by the bracket. Screw the L-shaped bracket to the guide groove fixed on both ends of the rack to ensure that the switch is stable and horizontally installed on the rack Note Good grounding rack is anti-static equipment, anti-leakage, lightning protection, anti-jamming important guarantee, so to ensure that the rack ground wire properly installed; Installation equipment within the rack from the bottom up, to avoid overload installation; Avoid placing other heavy objects on switch to avoid accidents; Ensure heat dissipation and air circulation. Chapter3 Hardware connection 3.1RJ45 port connection Connect the RJ45 port of the switch and the corresponding network device via cables, the POE power supply function of the switch is default enabled on the downlink port of the switch, which can be used for IEEE802.3af or IEEE802.3at standards powered devices such as APs, bridges, and network cameras Note When the switch connected workstations, servers, routers or other Ethernet devices the cable length should be within 100 meters; The Auto-MDI / MDIX Ethernet interface is enabled by default. Category 5,the standard network cable or crossover cable can be used for Ethernet connection. Do not connect the RJ45 port to the phone line 3.2SFP Port connection ELECTRA-T16 SFP port only support Gigabit fiber module. Recommended use of standard SFP module products The process of installing a fiber module on a switch is as follows: First, grasp the optic fiber module from the side, insert it smoothly along the SFP port slot until the optic fiber module and switch are in close contact; Second, confirm the Rx and Tx ports of the fiber module when connecting, insert one end of the fiber into the Rx and Tx ports correspondingly, ensure that the Tx and Rx ends of the interface are connected correctly and the other end of the fiber is connected to another device; Third, please check the corresponding indicator light status after power on. If the light blinking that the link is properly connected, if the light is off , the link is failure, pleasecheck the line to confirm that the corresponding equipment is enabled. Note Does not allow excessive bending fiber, the radius of curvature should not be less than 10cm; Ensure the cleanliness of the fiber surface; Please do not look directly into the optical fiber connector with your eyes as this may cause eye injury 3.3 Check before power on Check whether the outlet power supply meets the switch specifications; Check the power, switches, racks and other equipment have been properly grounded; Check whether the switch and other network devices are connected properly 3.4 Device initialization The switch automatically initializes when the power switch is turned on. Indicator will appear the following situation: After the power is turned on, the power indicator remains on, the other indicator is off at this time; After about 1 second, all lights except for the power light turn on for about 35 seconds and then turn off; when the SYS light goes flashing, the system runs normally Port LEDs indicates the connection status of each port, indicating that the switch has started to work normally 3.5Web Login Step1In the normal operation of the device, connect the computer to the switch's RJ45 port by network cables Step 2 Manually changed the computer IP address to 192.168.254.X (X is 2 ~ 254), subnet mask is 255.255.255.0 Step3Open computer's browser, type 192.168.254.1 in the address box, hit the Enter key Step4Enter the default username and password "admin" and then click Login Step5Entered the switch web management interface successfully when you see picture as below, you can begin to configure the switch Chapter 4 Hardware Specifications 4.1Hardware Specifications Network standard IEEE 802.3i IEEE 802.3u IEEE 802.3x IEEE 802.3ab IEEE 802.3af IEEE 802.3at 16 10/100/1000Mbps RJ45 port Port 2 gigabit SFP 1 Console 16 10/100/1000Mbps RJ45 port support PoE+ PoE Max 150W Single port max 46W LEDs Performance Lightning protection Input 18 Link/Act LEDS 16 POE LEDs 1 SYS LED 1 Power LED Forwarding mode: store and forward Bandwidth36Gbps Packet forwarding rate23.8Mpps 8K MAC address table 6KV 100-240V/50-60Hz Dimension L×W×H 440mm×180mm×44mm 4.2 Software Specifications Protocol standard IEEE 802.3:Ethernet Media Access Control (MAC) Protocol IEEE 802.3i:10BASE-T Ethernet IEEE 802.3u:100BASE-TX Fast Ethernet IEEE 802.3ab:1000BASE-T Gigabit Ethernet IEEE 802.3z:1000BASE-X Gigabit Ethernet (fiber) IEEE 802.3ad:Standard method for performing link aggregation IEEE 802.3x:flow control IEEE 802.1p:LAN Layer 2 Qos/Cos protocol for traffic priority (multicast filtering) IEEE 802.1q:VLAN IEEE 802.1d:STP Spanning tree IEEE 802.1s:MSTP Spanning tree IEEE 802.1w:RSTP Spanning tree IEEE 802.3af IEEE 802.3at Shortcut function DHCP One key AI VLAN One key AI Extend(1-8 port 250meters PoE distance) One key AI PoE One key Q0S (Video priority) Support DHCP Snooping Support 4K VLAN VLAN Support 802.1Q VLANMAC VLAN ,IP VLAN MAC address table Voice VLAN Comply the IEEE 802.1d standard Support MAC address learning and aging automatically Support static, dynamic, filter address table Password protection Safety Support based on the port number, IP address, MAC address restrictions on user access Support HTTPSSSL V3TLS V1SSH V1/V2 Support IP-MAC-PORT ternary binding Support ARP protection, IP source protection, DoS protection Support DHCP SnoopingDHCP attack protection Support 802.1X certificatedAAA Support port security, port isolation Support CPU protection POE management Support POE power limit Support POE chip status view Support setting PoE port priority Support setting PoE power supply time period Access control (ACL) Quality of Service (QoS) Support L2 (Layer 2) ~ L4 (Layer 4) packet filtering Support port mirroring, port redirection, flow rate limiting, QoS re-marking Support 8 port queue Support port priority, 802.1p priority, DSCP priority Spanning Tree Support SPRRWFQ Priority scheduling algorithm Support STP(IEEE 802.1d)RSTP(IEEE 802.1w) and MSTP(IEEE 802.1s) protocol Support loop protection, root bridge protection, TC protection, BPDU protection, BPDU filtering Multicast Support IGMP v1/v2 Snooping Support fast leave mechanism Storm suppression Link aggregation Support multicast VLAN Supports multicast filtering, packet statistics, and unknown multicast discards. Support multicast suppression Support broadcast suppression Support unknown unicast suppression Support static aggregation Support dynamic aggregation IPv6 Support IP, MAC, and hybrid load balancing modes Supports up to 32 aggregation groups Support IPv6 PingIPv6 TracertIPv6 Telnet Support IPv6 SSH IPv6 SSL Support WEB network management (HTTP, HTTPS, SSL V3) Management and maintenance Support CLI (Telnet, SSH V1/V2, local serial port) Support SNMP V1/V2/V3 Support LLDPRMON Support ARP protection, IP source protection, DoS protection Support CPU monitoring, memory monitoring Support system log, grading warning Support Ping, Tracert detection, cable detectionAdobe PDF Library 20.9.95