Instruction Manual for Solcon models including: AT5200, 2BACHAT5200, EOS-RTLS-AT5200 Anchor Transponder, EOS-RTLS-AT5200, Anchor Transponder, Transponder

OM EOS-RTLS-AT5200

Marco Roecker

Users Manual Regulatory Statement

Solcon Systemtechnik GmbH AT5200 2BACHAT5200 2BACHAT5200 at5200


File Info : application/pdf, 16 Pages, 1.22MB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7317555
OPERATION MANUAL ANCHOR TRANSPONDER
EOS-RTLS-AT5200
1.4
Solcon Systemtechnik GmbH Niels-Bohr-Ring 3-5 23568 Lübeck Telefon: +49 (0)451 40948 0 Telefax: +49 (0)451 40948 88
Copyright © Solcon Systemtechnik GmbH 2023 This documentation is protected by copyright. The resulting rights, in particular those of translation, reprinting, the removal of illustrations, radio transmission, reproduction by photomechanical or similar means and storage in data processing systems, are reserved, even if only used in extracts.

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
TABLE OF CONTENTS 1 Introduction.................................................................................................................................................... 3
1.1 Subject to Change.................................................................................................................................. 3 1.2 Declaration of Conformity ..................................................................................................................... 3 2 Safety and Use................................................................................................................................................ 4 2.1 RF Exposure Statement ......................................................................................................................... 4 3 Scope of delivery ............................................................................................................................................ 5 4 Assembly ........................................................................................................................................................ 6 5 Connection schemes .................................................................................................................................... 10 5.1 TWR mode connection diagram .......................................................................................................... 10 5.2 Connection diagram TDoA mode......................................................................................................... 11 6 Operation .................................................................................................................................................... 12 6.1 Description of LEDs.............................................................................................................................. 12 6.2 Commissioning .................................................................................................................................... 13 7 Maintenance and care.................................................................................................................................. 14 8 Warranty ...................................................................................................................................................... 14 9 Device Specification ..................................................................................................................................... 15

Status
Release

Version
1.4

Date
24.04.2024

Page
2/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
1 Introduction
The EOS RTLS anchor transponders are installed in a certain space as fixed reference points and thus enable the construction of a positioning field within the framework of the EOS RTLS system. They are designed for indoor use only. Using UWB radio, it is possible to locate mobile RTLS transponders using both two-way ranging (TWR) and timedivision-of-arrival (TDOA) methods. These instructions contain general information on the installation, operation, handling and care of the device as well as information on the structure and its functions.
1.1 Subject to Change
Solcon Systemtechnik reserves the right to make changes to these instructions or the products described from the current series. Solcon Systemtechnik assumes no responsibility for technical or editorial omissions and/or errors in this manual.
1.2 Declaration of Conformity

This device can be expected to comply with part 15 of the FCC Rules provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference receiving including interference that may cause undesired operation.
You can request the appropriate declaration of conformity for your device by stating the device serial number at:
Solcon Systemtechnik GmbH
Niels-Bohr-Ring 3-5
23568 Lübeck
PHONE: +49(0)451-40948-0
FAX: +49(0)451-40948-88
E-MAIL: INFO@SOLCON-SYSTEMTECHNIK.DE

Status
Release

Version
1.4

Date
24.04.2024

Page
3/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
2 Safety and Use
Be sure to read this manual before operating the device. These operating instructions are an important part of the scope of delivery and must also be handed over if the device is passed on. Accident prevention regulations and safety rules must be observed!
DURING OPERATION, THERE SHOULD BE A DISTANCE OF AT LEAST 20 CM
BETWEEN THE DEVICE AND PEOPLE
ONLY AUTHORIZED PERSONS ARE ALLOWED TO OPEN THE DEVICE.
BEFORE SEALING, MAKE SURE THAT THERE ARE NO LOOSE PARTS IN THE DEVICE.
THE DEVICE MUST BE PROTECTED FROM WATER. DO NOT PLACE BEVERAGES OR LIQUIDS ON THE APPLIANCE.
KEEP METALLIC OR KEEP CONDUCTIVE MATERIALS INSIDE THE APPLIANCE.
BEFORE MOVING, MOUNTING OR OPENING THE APPLIANCE, DISCONNECT THE POWER CORD FROM THE MAINS SUPPLY.
DAMAGED CABLES, PROTECTIVE COVERS AND PLUG MUST BE REPLACED IMMEDIATELY.

2.1 RF Exposure Statement

This device has been tested and found to comply with the requirements set forth in 47 CFR Part 15 for both fundamental emissions and unwanted emissions. These limits are designed to provide reasonable protection against any harmful interference when the device is operated in a commercial environment.
Modifying the device without Solcon Systemtechnik GmbH authorization may result in the device being no longer compliant with FCC requirements. In that event, your right to use the device may be limited by FCC regulations, and you may be required to correct any interference to radio or television communications at your own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the device.
This device complies with the requirements set forth in FCC 47 CFR Section § 1.1307 addressing RF exposure from radio frequency devices. To maintain compliance, the minimum separation distance from the antenna to general bystander is 20 cm.

Status
Release

Version
1.4

Date
24.04.2024

Page
4/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
3 Scope of delivery
1x EOS-RTLS-AT5200 with articulated arm and M8 threaded plug
Figure 1: EOS-RTLS-AT5200

Status
Release

Version
1.4

Date
24.04.2024

Page
5/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
4 Assembly
For mounting the EOS-RTLS-AT5200, it has an articulated arm with an integrated M8 thread. It can be attached to an M8 threaded rod or by screw. In addition, the inclination of the anchor can be adjusted using the articulated arm.

Figure 2: Articulated arm with threaded rod screwed in

Status
Release

Version
1.4

Date
24.04.2024

Page
6/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200

Figure 3: Anchor side view
The anchor should be hung with the rear LAN port facing up.
To adjust the incline, the pivot screw (circled in red) must be loosened with a 5mm Allen key. After that, the inclination can be adjusted as desired. The position shown in Fig.3 is defined as the 0° position.

Status
Release

Version
1.4

Date
24.04.2024

Page
7/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200

Figure 4: Anchor with tilt adjusted

Status
Release

Version
1.4

Date
24.04.2024

Page
8/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
The anchor must always be secured against falling. To do this, a steel cable is pulled through the gap on the articulated arm and fastened as a loop. (See Fig. 5)

Figure 5: Anchor with indicated fall protection (red)

Status
Release

Version
1.4

Date
24.04.2024

Page
9/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
5 Connection schemes
The anchors can be used in two modes of operation, TWR or TDoA operation. During installation, the connection diagram for the respective operating mode must be observed.
5.1 TWR mode connection diagram
In TWR mode, the anchor must be connected to a PoE switch using a CAT.7 Ethernet cable. This must ensure both the power supply and the connection to the EOS RTLS system.

Figure 6: TWR mode connection diagram

Status
Release

Version
1.4

Date
24.04.2024

Page
10/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
5.2 Connection diagram TDoA mode
In TDoA mode, the anchor must also be supplied with a clock signal via an EOS RTLS timer box. To do this, the PoE switch is connected to the input side of the timer box. The output side of the timer box is then connected to the anchors.

Figure 7: TDoA mode connection diagram

Status
Release

Version
1.4

Date
24.04.2024

Page
11/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
6 Operation
6.1 Description of LEDs
The anchor has three LEDs on the front. (See Fig. 8) LED1 Color orange Function: Indicates whether the armature is powered Behavior: Solid orange when the armature is powered LED2 Color green Function: Signals a correct TCP connection to the server Behavior: Lights up green, while a TCP connection is established LED3 Colour blue Function: Indicates whether UWB communication is currently taking place Behaviour: Lights up blue in the event of an existing UWB communication

Status
Release

Version
1.4

Date
24.04.2024

Page
12/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
LED1 LED2 LED3

Figure 8: Frontside LEDs
6.2 Commissioning
The anchor is put into operation by plugging an Ethernet cable into the RJ45 socket on the back. All LEDs light up simultaneously for approx. one second. After the start-up process, only LED1 lights up permanently in orange. The anchor is now powered up and ready for use.

Status
Release

Version
1.4

Date
24.04.2024

Page
13/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
7 Maintenance and care
The anchor is maintenance-free.
8 Warranty
The anchor is guaranteed for 12 months. The warranty is limited to design and manufacturing defects. Wear parts and damage caused by incorrect handling or use outside of the environmental specifications are excluded from the warranty. The warranty also expires if the device is opened. In addition, our general terms and conditions apply, which can be found under the following link: http://www.solcon-systemtechnik.de/agb/

Status
Release

Version
1.4

Date
24.04.2024

Page
14/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
9 Device Specification

Technical specifications Dimensions in mm (L/W/H) Weight Input voltage
Power consumption Temperature range

150 X 150 X 82,5 500 g Power over Ethernet (PoE) nach IEEE 802.3at 5W -10°C to 60°C

CONTACT
PHONE.: (0451)-40948-0 FAX.: (0451)-40948-88 EMAIL: INFO@SOLCON-SYSTEMTECHNIK.DE WWW.SOLCON-SYSTEMTECHNIK.DE

D Note on environmental protection At the end of its useful life, this product must not be disposed of with normal household waste, but must be taken to a collection point for the recycling of electrical and electronic equipment. The symbol on the product, the instructions for use or the packaging indicates this. The materials are recyclable according to their labeling. By reusing, material recycling or other forms of recycling old devices, you are making an important contribution to protecting our environment. Please ask the municipal administration for the responsible disposal point.
Note: You are also welcome to contact us at info@solcon-systemtechnik.de with the subject disposal of old devices, we will be happy to help you.

Status
Release

Version
1.4

Date
24.04.2024

Page
15/16

OPERATION MANUAL ANCHOR TRANSPONDER EOS-RTLS-AT5200
Solcon Systemtechnik GmbH
Niels-Bohr-Ring 3-5 D-23568 Lübeck
Tel.: +49(0)451- 4094 8 - 0 Fax.: +49(0)451- 4094 8 - 88 info@solcon-systemtechnik.de
www.solcon-systemtechnik.de

Status
Release

Version
1.4

Date
24.04.2024

Page
16/16



References

Microsoft: Print To PDF