Instruction Manual for ITC models including: RGB Smart System, RGB, Smart System, System

VersiControl RV-C Smart System Plus

PDF preview unavailable. Download the PDF instead.

VersiControl Smart System Plus RV-C Install Ins
VersiControl RV-C Smart System Plus
Part#: 2300X-KKKK-RV-01
PARTS / TOOLS NEEDED:

INSTALLATION INSTRUCTIONS

VersiControl RGB Smart System

RGB Lighting (Varies)

Mounting Screws x 4 (not provided)

Butt Splices (not provided)

Power Drill

Safety Instructions
· Disconnect power before installing, adding or changing any component. · To avoid a hazard to children, account for all parts and destroy all packing materials. · Do not install any luminaire assembly closer than 6" from any combustible materials. · Positive (+) outputs require a fuse if the attached wire leads are not rated to handle the max current. · This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference - This device must accept any interferences received, including interference that may cause undesired operation

1. INSTALL: Determine the installation location for your control module. Make sure to consider the size of the module (7.5"L x 5"W x
1.5"H) when determining your location. Note, it will require room for access and for wiring. Screw the controller in place using four M5 stainless steel screws (not provided) sized appropriately for the substrate material used. Make sure when mounted, that the Bluetooth antenna is not obstructed by metal objects.
7.5"

5"

1.5"

Bluetooth Antenna
2. ZONE WIRE CONNECTIONS: Refer to the diagram below for reference when wiring the system in steps 3 and 4. Note, there can be
8 or 10 zone wires coming out of the controller. Each wire has been individually placed on the grommet of the assembly.

ZONE 2
+ R G BW + R G BW
ZONE 1

3030 Corporate Grove Dr. Hudsonville, MI 49426 Phone: 616.396.1355 itc-us.com

For warranty information please visit www.itc-us.com/warranty-return-policy DOC #: 710-00224 · Rev B · 03/13/24
Page 1 of 5

3. TWO-ZONE WIRING DIAGRAMS: Follow the wiring diagram below to wire the module to your system. Note: Maximum replacement
fuse size is 20 amps.

Inputs

Disable Lines Zone 1 - White Zone 2 - White/Red Zone 3 - White/Green Zone 4 - White/Blue

Red - 12-24V DC IN (+) Black - 12-24V DC IN (-) (Max 20A)
*Mating Connector: Deutsch DTP06-2S

Fuse

Controller

CAN (+) White 1 CAN (-) Blue 2 V (-) Black 3 V (+) Red 4
*Mating Connector: Deutsch DT06-4S

Outputs
Zone 1 - (Max 10A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue
Zone 2 - (Max 10A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue
*Mating Connector: Deutsch DT04-4P

23002-RGB-RV-01
Inputs
Disable Lines Zone 1 - White Zone 2 - White/Red

Red - 12-24V DC IN (+) Black - 12-24V DC IN (-) (Max 20A)
*Mating Connector: Deutsch DTP06-2S

Fuse

Controller

CAN (+) White 1 CAN (-) Blue 2 V (-) Black 3 V (+) Red 4
*Mating Connector: Deutsch DT06-4S

23002-RGBW-RV-01

Outputs
Zone 1 - (Max 12A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue 5 Black/White
Zone 2 - (Max 12A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue 5 Black/White
*Mating Connector: Deutsch DT04-6P

3030 Corporate Grove Dr. Hudsonville, MI 49426 Phone: 616.396.1355 itc-us.com

For warranty information please visit www.itc-us.com/warranty-return-policy DOC #: 710-00224 · Rev B · 03/13/24
Page 2 of 5

3. FOUR-ZONE WIRING DIAGRAMS: Follow the wiring diagram below to wire the module to your system. Note: Maximum replacement
fuse size is 20 amps.

Inputs

Outputs

Disable Lines Zone 1 - White Zone 2 - White/Red Zone 3 - White/Green Zone 4 - White/Blue

Red - 12-24V DC IN (+) Black - 12-24V DC IN (-) (Max 20A)
*Mating Connector: Deutsch DTP06-2S

Fuse

Controller

CAN (+) White 1 CAN (-) Blue 2 V (-) Black 3 V (+) Red 4

*Mating Connector: Deutsch DT06-4S

23004-RGB-RV-01

Zone 1 - (Max 10A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue
Zone 2 - (Max 10A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue
Zone 3 - (Max 10A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue
Zone 4 - (Max 10A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue
*Mating Connector: Deutsch DT04-4P

Inputs
Disable Lines Zone 1 - White Zone 2 - White/Red Zone 3 - White/Green Zone 4 - White/Blue

Red - 12-24V DC IN (+) Black - 12-24V DC IN (-) (Max 20A)
*Mating Connector: Deutsch DTP06-2S

Fuse

Controller

CAN (+) White 1 CAN (-) Blue 2 V (-) Black 3 V (+) Red 4
*Mating Connector: Deutsch DT06-4S

23004-RGBW-RV-01

Outputs
Zone 1 - (Max 12A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue 5 Black/White
Zone 2 - (Max 12A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue 5 Black/White
Zone 3 - (Max 12A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue 5 Black/White
Zone 4 - (Max 12A)
1 (+) White/Red 2 Black/Red 3 Black/Green 4 Black/Blue 5 Black/White
*Mating Connector: Deutsch DT04-6P

3030 Corporate Grove Dr. Hudsonville, MI 49426 Phone: 616.396.1355 itc-us.com

For warranty information please visit www.itc-us.com/warranty-return-policy DOC #: 710-00224 · Rev B · 03/13/24
Page 3 of 5

4. CUSTOMIZING YOUR SYSTEM: There are several features that can
be selected using the four position dip switches on the back of the control module. To adjust these switches, first remove the four screws on the back.

Remove screws

MULTIPLE RGB CONTROLLERS ON SAME CAN BUS NETWORK: If you are using more than one controller on a CAN network, you will need to adjust the CAN address. Dip switch one and two are used to select an address.

RESET PASS CODE: If needed, dip switch three can be switched on and then off to reset the Bluetooth pass code.

SELECT TO POWER UP IN THE ON OR OFF STATE: Using dip switch four you can select if you want the controller to power up in the OFF state when power is applied, or in the ON state once power is applied.

Switch 1 OFF ON OFF ON

Switch 2 OFF OFF ON ON

Address 0 (Default)
1 2 3

Switch 3 OFF ON

Pass Code No change Reset pass code

Switch 4 OFF ON

Power Power up OFF (default)
Power up ON

Dip switch adjustment

5. DISABLE/SIGNAL INPUT LINE (optional): The control module has the ability to turn off zones if an input line to the controller is
activated. If the disable line is held at the input voltage (5-24 volts), Zones one and two will be turned off. This feature can be used if you want to deactivate the zone lights on the outside of the unit when in motion. By default, only zones one and two are turned off. There is no effect on zones three and four (if applicable). You can adjust which zones are turned off via a CAN interface display system.
6. WIRING CONSIDERATIONS:
- Don't power the controller or lights until all connections are made. - It is recommended that strain relief be added on all wires to prevent any damage to the lights. - If fuses are not included on the RGB controller then ITC recommends including fuses on each zone output (+) wire. - If installing a flexible lighting product, do not install the end caps in the mounting track or it may damage the light. - To test the lights, select the single color fade for each of the colors, red, green and blue on the VersiControl app. This test will show
whether there are wiring issues.

3030 Corporate Grove Dr. Hudsonville, MI 49426 Phone: 616.396.1355 itc-us.com

For warranty information please visit www.itc-us.com/warranty-return-policy DOC #: 710-00224 · Rev B · 03/13/24
Page 4 of 5

Installation Considerations for Preventing EMI Noise
WHAT IS EMI NOISE? Electromagnetic interference (EMI) is any unwanted signal which is either radiated(thru air) or conducted(thru wires) to electronic equipment and interferes with the proper operation and performance of the equipment. All electrical/electronic components that have varying or switching currents, such as RGB lighting, create Electromagnetic interference (EMI noise). It is a matter of how much EMI noise they produce.
These same components are also susceptible to EMI, especially radios and audio amplifiers. The unwanted audible noise that is sometimes heard on a stereo system is EMI.
DIAGNOSING EMI NOISE If EMI is observed the following steps should help isolate the problem.
1. Turn off LED light(s)/controller(s) 2. Tune the VHF radio to a quiet channel (Ch 13) 3. Adjust the radio's squelch control until the radio outputs audio noise 4. Re-adjust the VHF radio's squelch control until the audio noise is quiet 5. Turn on the LED light(s)/controller(s) ­ If the radio now outputs audio noise then the LED lights may have
caused the interference. 6. If the radio does not output radio noise then the problem is with another part of the electrical system.
PREVENTING EMI NOISE
Once the EMI noise is isolated the following steps can be used to help prevent and lessen the effect of the noise. CONDUCTED & RADIATED SOLUTIONS GROUNDING (BONDING) : How each component is connected and routed to power ground is important. Route the ground of sensitive components back to the battery separately. Eliminate ground loops.
SEPARATION : Physically separate and mount the noisy components away from sensitive components. In the wire harness, separate the sensitive wires from the noisy wires.
FILTERING : Add filtering to either the device creating the noise or the sensitive device. Filtering may consist of power line filters, common-mode filters, ferrite clamps, capacitors and inductors.
RADIATED SOLUTIONS SHIELDING : Shielded cables can be used. Shielding the component in a metal enclosure is also an option.
If you continue to experience EMI issues please contact your ITC sales representative.

3030 Corporate Grove Dr. Hudsonville, MI 49426 Phone: 616.396.1355 itc-us.com

For warranty information please visit www.itc-us.com/warranty-return-policy DOC #: 710-00224 · Rev B · 03/13/24
Page 5 of 5


Adobe PDF Library 17.0 Adobe InDesign 19.2 (Windows)