Instruction Manual for blinkcharging models including: DC Fast EV Charging Stations, DC Fast EV, Charging Stations, Charging, Fast EV Charging
30kW DC Fast EV Charging Stations : Blink Charging
This manual covers the electrical and mechanical installation procedure for the Tellus TP-EVPD-30kW ... Max Voltage: 1000VDC; Connectors: CCS1 and CHAdeMO.
File Info : application/pdf, 20 Pages, 1.57MB
DocumentDocumentINSTALLATION MANUAL 30kW DC CHARGER Product# TP-EVPD-30kW BlinkCharging.com · (888) 998.2546 Installation Manual This manual covers the electrical and mechanical installation procedure for the Tellus TP-EVPD-30kW charger. The operations and programming manual are separate. The model hosts different voltage and connector configurations. Below are different product numbers. TP5-30-480-1 TP5-30-480-2 TP5-30-480-2 Max Voltage: 1000VDC; Connectors: CCS1 Max Voltage: 1000VDC; Connectors: CCS1 and CHAdeMO Max Voltage: 1000VDC; Connectors: CCS1 and CCS1 BlinkCharging.com · (888) 998.2546 1 Installation Manual Table of Contents 1. Critical Safety..........................................................................................................3 2. Installation...............................................................................................................4 3. Installation Overview................................................................................................6 4. Outline of Drawing TP-30-480 DCFC .........................................................................7 5. Station Anatomy .....................................................................................................8 6. Charger Installation ................................................................................................9 7. Operating Instructions .............................................................................................12 8. How to Start a Charging Session .............................................................................13 9. Charger Settings ....................................................................................................14 10. Maintenance and Service ........................................................................................15 11. Troubleshooting ......................................................................................................16 12. Customer Responsibilities ........................................................................................17 13. Warranty ..............................................................................................................18 14. Appendix...............................................................................................................19 BlinkCharging.com · (888) 998.2546 2 Installation Manual 1. CRITICAL SAFETY READ THE ENTIRE MANUAL BEFORE DESIGNING OR INSTALLING EQUIPMENT This unit is a high-powered electrical device and can be hazardous if improperly installed, serviced, or operated. Failure to follow procedures in this manual could result in extreme hazard to personnel and/or damage to the equipment and related infrastructure. In addition, the installation, service, and maintenance need to comply with local codes and the Authority Having Jurisdiction (AHJ). IMPORTANT SAFETY INSTRUCTIONS The symbols used are international icons used to depict various levels of caution when installation, servicing or maintaining the equipment. Same symbols will also appear on the equipment for identifying caution levels required when access certain areas of the charger. DANGER High voltage danger label to keep people safe from electrical discharge, which could result in injury or potential death. WARNING Warning icon represents hazard, that could result in severe injury or possibly death. GENERAL CAUTION Caution icon represents a potential hazard or unsafe practice that could result in injury SERVICE WARNING There are no serviceable items inside the equipment. There is high voltage inside the equipment which could cause severe injury or death. Do not attempt to repair the charge station yourself. This can only be performed by factory qualified personnel. CHARGING CABLE DAMAGE Do not operate the charger if the charging cable is damaged or if here are exposed wires in the charging cord assembly. Shut off power at the electrical disconnect or at the breaker. Then immediately contact Tellus service. If there are any questions, please contact customer service. BlinkCharging.com · (888) 998.2546 3 Installation Manual 2. INSTALLATION SAFETY INSTRUCTIONS Read the entire installation instructions before designing the installation and prior to installation. This equipment should be installed by a journeyman level electrician. Local building codes need to be complied with. In most jurisdictions the installation of this equipment requires plan check, building and electrical permits. Verify with the local Authority Having Jurisdiction prior to starting construction. The charging station relies on the grounding system for safety. All grounding instructions should be strictly adhered to as prescribed in this manual and any applicable electrical safety requirements, all local electrical safety codes, and NEC. HIGH VOLTAGE EQUIPMENT: This charging system contains both AC and DC high voltage circuitry and devices and should only be installed by a qualified electrician trained to work on high voltage, high current AC and DC systems. ADA Consideration This equipment has been designed to meet ADA requirements when installed as prescribed in this manual and in accordance to the STANDARDS FOR ACCESSIBLE DESIGN for Americans with Disabilities document, 2010 ADA Standards for Accessible Design: http://www.ada.gov/2010ADAstandards_index.htm Parking space, allowances for wheelchair movement, charger, bollards, and parking stops are defined in several publicly available EV charger installation recommended practices documents incorporating the ADA requirements. http://www.ada.gov *For information about the ADA, including the revised 2010 ADA regulations, please visit the Department's website www.ADA.gov; or, for answers to specific questions, call the toll-free ADA Information Line at 800- 514-0301 (Voice) or 800-514-0383 (TTY). ADDITIONAL CAUTIONARY NOTES WARNING Do not have power on while any of the maintenance doors are open unless proper personnel protection equipment is worn. Only trained personnel should be working in this equipment while the doors are open, and the unit is powered on. WARNING There are high voltage and high-capacity energy storage components on this system. There are components and circuits that remain charged for some time (1 to 2 minutes) with high voltage power, even after main power is disconnected. Always test with a voltmeter before any maintenance or service is performed. This manual covers the electrical and mechanical installation procedure for the Tellus TP-EVPD-30kW charger. BlinkCharging.com · (888) 998.2546 4 Installation Manual SPECIFICATIONS Product # Input FLA || Breaker Output Voltage Output Current Connector(s) Efficiency Power Factor Operating Temperature Working || Storage humidity Altitude Display RFID System Dimensions (l x d x h) Protective Class Cooling System Weight Charging Protocol Length of charging cable Interface protocol Communication Electrical Safety: GFCI Electrical Safety: Surge Protection Electrical Safety General Electrical Safety: Output Short Electrical Safety Temperature Emergency Stop Regulatory Compliance TP5-30-480 480VAC (3P+N+PE), 60Hz 40A || 63A 150 to 1000VDC 0 to 100A CCS1 Dual CCS1 94% at nominal output power > 0.98 22°F to 131°F (-30°C to 55°C) 95% RH || 99% RH (Non-condensing) < 6600ft (2000m) 7'' LCD with touch screen ISO || IEC 14443A/B 21'' x 12'' x 27'' 25'' x 12'' x 27'' (Dual) NEMA 3S, IK 10 Air cooled 176 lbs (80kg) 220 lbs(100kg) - Dual Mode 4, IEC-61851, ISO-15118, DIN SPEC 70121 16ft (5m) OCPP 1.6J Ethernet / 4G Wi-Fi RCD 20 mA Type A (UL) 20 kA Over Voltage, Under Voltage, Over Current, Missing Ground Output power disabled when output is short circuited Temperature Sensors @ Charge Coupler and Power Electronics Emergency Stop Button Disables Output Power UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6- 3:2007/A1:2011/AC:2012 BlinkCharging.com · (888) 998.2546 5 Installation Manual 3. INSTALLATION OVERVIEW Electrical Input Requirements Location Mounting Cables Grounding Breaker Miscellaneous Additional notes Input voltage: 480 VAC (3 Phase + Neutral + Earth), 60Hz Full Load Amperage: 40 Amps (At Rated power) Breaker Capacity: 63 Amps The charger can be installed on any stable wall or any pole structure with appropriate brackets. The input cable provision is provided from the bottom the charger. The height of the charger should be in above 4 ft from the ground. Charger Dimensions (L x D x H): 21'' x 12'' x 27'' || 24'' x 12'' x 27'' Wall Mount Input Cables must be Copper (3P+N+PE). Flexible copper is preferred. Depending on the situation and cable type, the cables must be embedded in the ground with proper cable duct. Reliable protective grounding must be provided. It is recommended to have separate dedicated ground exclusively for the charger considering the safety aspects. The ground resistance should be less than or equal to 4. Copper cable of in accordance with NEC shall be used to connect charger housing to external ground. Breaker (3P+N) with suitable current capacity depending up on the charger rating to be provided. This shall be in accordance with NEC, typically 1.25 X Full Load Amperage. Copper lugs (Flat type) for input cable and earth cable should be provided based on size of cable. Do not let the flammable, explosive or flammable materials, chemicals, flammable vapors, and other dangerous goods close to charging station In the areas of floods, heavy rains, storms, snow, or similar harsh weather conditions, Tellus recommends a canopy for the charger for protection. The charger is IP54. Confirm that your installation site has a load capacity sufficient to support this equipment. Charge cable length depending on options will be between 13 ft & 16 ft BlinkCharging.com · (888) 998.2546 6 Installation Manual 4. OUTLINE OF DRAWING TP-30-480 DCFC Charger Depicted to be mounted on a stand. The dimension of the bracket remains the same from wall mount and stand mount (units of measure in mm). BlinkCharging.com · (888) 998.2546 7 Installation Manual 5. STATION ANATOMY Screen Touchscreen display provides real-time instructions and feedback to EV drivers about services available, payment options, and any errors Emergency Stop Button Safety Measure-if pressed all charging activity will be immediately stopped Encrypted RFID Reader An RFID reader that identifies EV drivers by placing their RFID card on the pad DCFC Cord Mount Allows for placement of DCFC connector cables for ease of use and storage. BlinkCharging.com · (888) 998.2546 8 Installation Manual 6. CHARGER INSTALLATION PLACING CHARGER ON THE WALL A forklift will be required to move the charger into position. The charger with the crate will weigh around 240lbs. The charger without the crate weighs around 175 lbs. To lift the charger, use the forklift cut-outs in the lower frame of the charger. The charger will be provided with a mounting bracket on the rear. The mounting bracket comes with holes that are to be used for placement of the station. The mounting screws are included in the delivery package and should be used on a brick or concrete wall for appropriate support. Mounting Bracket Dimensions (in inches) Mounting Bracket 3D BlinkCharging.com · (888) 998.2546 9 Installation Manual CHARGER MOUNTING 1. Hold the installation bracket against the wall. 2. Make sure that the bracket is levelled. Use the spirit level to ensure. 3. Mark the location for the mounting holes. 4. Drill the mounting holes as per the template provided. 5. Insert the mounting bolts in the holes. 6. Fix the charger on the mounting bracket and fix it with the screws. BlinkCharging.com · (888) 998.2546 10 Installation Manual AC INPUT POWER WIRING INPUT VOLTAGE The Charger requires an Input voltage of 480 VAC (3 Phase + Neutral + Earth), 60Hz and current of 40 Amps. Schematic diagram of the input connection of the charger. AC INPUT TERMINATION MAIN BREAKER ABC are the 3 Phase Lines N is the Neutral. PE is the Protective Earth or Ground Line Side Single input option: 25 sq mm Please follow local codes Ampere Rating per Pole: 63 Component Description: 4 Pole MCB BlinkCharging.com · (888) 998.2546 11 Installation Manual 7. OPERATING INSTRUCTIONS The Tellus Power Green charger provides multiple options to operate and charge the EV. All the Tellus chargers come with a standard RFID card reader, Smart charging facility and optional Credit Card reader. Below is the screen giving various options displayed. · Make sure the Emergency Button is turned off. · Switch ON the Charger from Main panel. · Switch the Main MCCB and MCB(s) within the charger · Wait for 1 to 2 minutes to Boot the machine and check 3 icons at top corner of Charger display should appear. This icon indicates the charger is not connected to a server network or loss of internet connectivity. If no network is connected, the station works as a stand-alone device with Tellus Power RFID cards. This icon indicates the charger is connected to a server network; it can be authorized with registered RFID cards or mobile app. The stable icon indicates working condition of the charger. If the icon flashes or not visible on the screen, the controller is inactive. RFID card reader is active. If the icon is not visible on the screen, the RFID reader is inactive. BlinkCharging.com · (888) 998.2546 12 Installation Manual 8. HOW TO START A CHARGING SESSION RFID CARD 1. Please select the connector compatible to your EV 2. Plugin the connector, and for CHAdeMO press the "Please to Connect CHAdeMO". 3. Charger display will show "Please swipe the card". 4. Swipe the registered RFID card. 5. Charging session will begin within 60 seconds. 6. To stop the charging Swipe the same RFID card again or use STOP button on screen. QR CODE / MOBILE APP 1. Please select the Gun compatible to your EV. 2. Plugin the connector, and for CHAdeMO press the "Please to Connect CHAdeMO". 3. Charger display will show "Please swipe the card / Scan QR". 4. Scan the QR code or start the charging from Mobile App. 5. Charging session will begin within 60 seconds. 6. To stop the charging Stop from the Mobile App or use STOP button on screen CREDIT CARD 1. Please select the Gun compatible to your EV. 2. Plugin the connector, and for CHAdeMO press the "Please to Connect CHAdeMO". 3. Charger display will show "Please swipe the card / Scan QR". 4. Authorize your credit card. Make sure you have enough balance on the card to charge. 5. Charging session will begin within 60 seconds. 6. Charging will automatically stop after the 100% charge or use STOP button on screen. During the charging process, a real-time data output of the charging process on the screen appears. At any point of time, charging session can be stopped using Stop button on the screen or Emergency Stop button. BlinkCharging.com · (888) 998.2546 13 Installation Manual 9. CHARGER SETTINGS SETTING PARAMETERS During the initial installation, the setting parameters must be set by the manufacturer or the operating partner, or the service partner. Changes may only be made by trained specialist personnel. The setting window can be accessed by following steps. 1) Touch the Tellus Power Logo 2) Provide the Password. Password will be shared to the authorized representative 3) Select System Settings PARAMETER TIME ZONE PSM QUANTITY POWER OUT MODE OCCUPIED PLUG PSM MAX VOLTAGE PSM MAX CURRENT PSM MID VOLTAGE PSM MID CURRENT PSM MIN VOLTAGE PSM MIN CURRENT PMAX CCS NETWORK 1 INSYS PLC MAC 1 TIME VALUE UTC+HH:MM 1 0 1 1000 100 300 20 50 0 30000 ETH1 00:00:00:00 2020-08-20 T20:46:25 S.NO PARAMETERS 1 NETWORK 2 NETCFGFILE 3 WLAN CONF 4 DEVICE IP 5 DEVICE GATEWAY 6 DEVICE NET MASK 7 SERVICE URL 8 DEVICE ID 9 CHARGE POINT VENDOR 10 CHARGE POINT MODEL 11 ADPATH 12 QRCODE NAME 13 LANG 14 MODE 15 CHARGING PIC 16 IDLE PIC BlinkCharging.com · (888) 998.2546 VALUE ETH /etc/network/interfaces /home/guest/wpa_supplicant.conf 192.168.0.3 192.168.0.1 255.255.255.0 <<Provide Portal Details>> <<Provide ID>> Tellus power DC ./pic en offline/record/upload/debug /img/charging_tata.jpg /img/standby.jpg REMARKS Ethernet-DO NOT CHANGE Path- DO NOT CHANGE Path- DO NOT CHANGE IP Adress of Device IP Adress of Gateway IP Adress of Mask OCPP Server URL Device ID Charger OEM- DO NOT CHANGE Charger Type- DO NOT CHANGE Path - DO NOT CHANGE NA Path - DO NOT CHANGE Path - DO NOT CHANGE Path - DO NOT CHANGE Path - DO NOT CHANGE 14 Installation Manual 17 LCM 18 LCM ENCODE TYPE 19 LCM PASSWORD 20 RFID 21 PLUG1 22 PLUG2 23 DC1QRCODE NAME 24 RFID ORIGINAL NUMBER /dev/ttyS4 UNICODE 123456 RFID0=/dev/ttyS1 GBTDC1:2=/dev/ttyS0 GBTDC2:2=/dev/ttyS0 1 Path - DO NOT CHANGE Encode - DO NOT CHANGE Password for access Path - DO NOT CHANGE Path - DO NOT CHANGE Path - DO NOT CHANGE NA NA 10. MAINTENANCE AND SERVICE DANGER READ AND FOLLOW THE "SAFETY CONCERNS" AT THE BEGINNING OF THIS MANUAL BEFORE USING THIS DEVICE EV Charging Stations require regular maintenance beyond installation to ensure the quality of the vehicle's charge, and the continued value of your electric vehicle. Whether you're installing a personal EV charger, or a public one for use, eventually you will require repair or maintenance services to keep your system working without flaws. MAINTENANCE PRECAUTIONS Each of the capacitors in this device have a high voltage for a time after shutting off the input power supply. Allow 1 minute after powering down before servicing internal components. MAINTENANCE ITEMS Perform periodic checks every 3 to 6 months based on the site conditions and the usage of the charging station. 1. Check the input voltage and ensure it is within the acceptable limits. 2. Check the Ground / Earth resistance and ensure it is within the acceptable limits 3. Clean the Air Filter periodically 4. Make sure that Power Module lights are blinks green 5. Ensure the charging cables are not worn out and gun pins are clean. 6. Make sure all the air-cooling fans are working normally. VISUAL CHECK ITEMS 1. Check for abnormal sound from running fans and power units. If there is abnormal sound, please contact Tellus 949-534-3000 for further assistance. 2. Check for abnormal odor, changes of inner materials, corrosion, anomaly in appearance, etc., in this device. If there are any anomalies, please contact a Tellus service representative for further assistance. 3. Check for dust and dirt in this device regularly. The air filters on the doors can be removed and cleaned BlinkCharging.com · (888) 998.2546 15 Installation Manual using a vacuum cleaner or air blower. The cabinet can be cleaned using a vacuum cleaner. The dust on the components can be cleaned using a soft cloth. Please pay extra attention while using the vacuum cleaner, it should not apply pressure on the control boards or any components. REPLACEMENT OF FIXED-LIFE COMPONENTS To prevent the device from failure due to worn out components, it is necessary to replace the components before they reach the end of their lifespan. Use the following replacement intervals as a guideline for the estimate of the total running time. Please contact a Tellus service representative for further assistance when you replace the parts. · Intake and exhaust air filters (if present): Approximately three (3) years. The period depends upon the site conditions. · Please keep in mind that the replacement interval of each part can vary depending on, for example, the usage environment of the device. 11. TROUBLESHOOTING ERROR CODES If an error occurs, check the nature of the error by referring to following "Error Code List" and take appropriate actions according to instructions by the manufacturer. ERROR ERROR FLAG 0 ERROR FLAG 1 ERROR FLAG 2 ERROR FLAG 3 ERROR FLAG 4 ERROR FLAG 5 ERROR FLAG 6 DESCRIPTION POSSIBLE SOLUTION Lightning protection device failure Insulation detection abnormal Check the SPD and GFCI circuit The insulation check on the EV has failed. Please try to charge different EV. Abnormal communication between Insulation Please check the connection between the IM and CM Monitor and Main Control Board (CM) boards. Check the LED lights on the CM and IM Abnormal communication between TR board and CM board Please check the connection between the tr and cm boards. Check the LED lights on the CM and TR Electronic lock failure Internal use Abnormal communication between DC meter and Main Control Board (CM) Possible failure of the gun to lock on the EV or the 24v supply voltage Reserved Please check the connection between the DC and CM boards. Check the LED lights on the CM and communication lines of DC meter. BlinkCharging.com · (888) 998.2546 16 Installation Manual FAULT TYPE IP address communication failure or Server Communication Failure AC input over voltage / under voltage DC output over voltage / over current Card reader failure Insulation fault Monitoring board communication failure Charging gun connection failure The emergency stop button is pressed Charging Session shutdown is not successful SOLUTION Check the SPD and GFCI circuit The insulation check on the EV has failed. Please try to charge different EV. Please check the connection between the IM and CM boards. Check the LED lights on the CM and IM Please check the connection between the tr and cm boards. Check the LED lights on the CM and TR Possible failure of the gun to lock on the EV or the 24v supply voltage Reserved Please check the connection between the DC and CM boards. Check the LED lights on the CM and communication lines of DC meter. Check whether the emergency stop button is pressed, if it is, inspect the charger and if everything is normal, release the emergency button and restore the main breaker MCU board and power module communication failure. Please press emergency stop button to stop the charging. Check the MCU board and power module CAN communication bus. 12. CUSTOMER RESPONSIBILITIES 1. To operate the charge station with the required protective devices such as MCBs and switches and proper cables installed. 2. The operator/owner/customer is cautioned that any changes or modifications not approved by Tellus shall void Tellus warranty policy 3. To write an emergency plan that instructs people what to do in case of emergency. 4. To locate and prepare the site as per the instructions laid out in this document. 5. To make sure that there is sufficient space around the charger to carry out any regular maintenance work. 6. To appoint a trained person(s) responsible for the safe maintenance/service of the charge station. 7. Neither Tellus nor any of its affiliates shall be liable to the operator/owner/customer of this product or third parties for damages, losses, costs, or expenses incurred by as a result of: an accident, misuse or abuse of this product or unauthorized modifications, repairs or alterations to this product, or failure to strictly comply Tellus operating and maintenance instructions. BlinkCharging.com · (888) 998.2546 17 Installation Manual 13. WARRANTY Warranty and Service Plan Tellus DC chargers comes with the 2 years parts only standard warranty. However, we offer service plans which covers parts and labor as well for an additional add-on fee. We can train your operators or engineers and equip with basic understanding of the troubleshooting and part replacement to make sure the equipment downtime as well as total cost of ownership is minimized. Warranty Terms LIMITED WARRANTY: Subject to the exclusions from warranty coverage set forth below, Tellus warrants that the Product will be free from any defects in materials and/or workmanship (the "Limited Warranty") for a period of two year after 30 days from the date of shipment or from date of the initial installation whichever is earlier (the "Warranty Period"). If the Product becomes defective in breach of the Limited Warranty, Tellus Power will, upon written notice of the defect received during the Warranty Period, either repair or replace, at Tellus Power's choice, the Product if it proves to be defective. Tellus Power will also pay for shipping charges for the failed part. If the returned part has not failed the customer will pay for shipping charges for the replacement part and the associated returned part. Under this guarantee, Tellus liability is limited to repair or replacement of the product with the same or equivalent, or reconditioned product warranted for the original warranty period. The warranty will not include removal costs, re-installation costs, loss of charging station revenue, nor loss or damage of any kind whatsoever, whether incidental, consequential, or otherwise. Exclusions From Limited Warranty IMPORTANT: The Limited Warranty and on your Product shall not apply to defects, or service repairs, resulting from any of the following: · Damages due to normal wear and tear to charging cords, connectors, LCD/LED display, Touch Screen, or any product alteration or modification, misuse, abuse, accident, vandalism, acts of nature, power surges, or use of software, parts, or supplies not supplied by Tellus, and causes other than manufacturing defects not covered by the warranty. · Force Majeure any occurrence or extraordinary event or circumstance beyond the control of Tellus Power that is an act of God or whether that occurrence is caused by war, riot, storm, (such as hurricane, flooding, earthquake, volcanic eruption, etc.), or other natural forces, including high input voltage from generators or lightning strikes or acts of nature or other causes. · Any Alteration or Modification of the Product in any way not approved in writing by Tellus Power. · Abuse, damage or otherwise being subjected to problems caused by negligence (including but not limited to physical damage from being struck by a vehicle) or misapplication, or misuse of the Products by customers or end users. · Any damage to the EV charger cord, unless such damage is caused by a manufacturing defect in the cord or connector assembly. · Improper site preparation or maintenance. That has been improperly installed, operated, handled, or used, including use under conditions for which the product was not designed, use in an unsuitable environment, or use in a manner contrary to the Tellus Installation and Operations Manual or applicable laws or regulations. · Damage because of accidents, extreme power surge, extreme electromagnetic field. · Use of the Product with software, interfacing, parts or supplies not supplied by Tellus Power Green. BlinkCharging.com · (888) 998.2546 18 Installation Manual · Tellus disclaims any liability for damage to product, property, or personal injury resulting in whole or in part, from improper installation, maintenance or use that is not in accordance with Tellus installation and maintenance procedures. · Maintenance or use that is not in accordance with Tellus installation and maintenance procedures. · That has been subjected to incidental or consequential damage caused by defects of other components of the electrical system. APPENDIX PD02-22V-10 BlinkCharging.com · (888) 998.2546 19