Function Introduction
The Pecron E2000 LFP features a comprehensive interface for power management and monitoring:
- 1. LCD Display: Provides real-time information on battery status, power input/output, voltage, and more.
- 2. DC 12V~18V Charging Port: For charging the unit with lower voltage DC sources, such as specific solar panels.
- 3. DC 32V~95V Charging Port: For charging the unit with higher voltage DC sources, such as solar arrays.
- 4. AC 100V~120V Output: Multiple standard AC outlets for powering various devices.
- 5. DC 12V/USB/Wireless Switch: Controls the DC 12V auxiliary output, USB ports, and wireless charging pad.
- 6. AC 100V~120V Switch: Controls the AC output. It is recommended to turn this off when not in use to conserve power.
- 7. DC12V Auxiliary Output: A DC output port, typically for car accessories.
- 8. DC12V(5525) Output: Specific DC output ports for compatible devices.
- 9. USB-A/USB-C Ports: Multiple USB ports for charging mobile devices and other electronics.
- 10. Wireless Charger: An integrated pad for convenient wireless charging of compatible devices.
- 11. Battery Expansion Port: Allows for connecting additional Pecron battery modules to increase capacity.
Specifications
Capacity | Battery Type | Charging Time | Protections | Temperature | Dimension | Net Weight |
---|---|---|---|---|---|---|
1920Wh (25.6V 75Ah) | LiFePO4 Battery (Retains 80%+ Original Capacity at 3500 Cycles) | 3.5~4H (Standard) 1.5~2H (Fast Charging) |
Over-Voltage, Overheat, Overload, Short-Circuit, Self-Recovery | 0°C~45°C / 32°F~113°F (Charging) -20°C~45°C / -4°F~113°F (Discharging) |
L16.1*W10*H11.6 in / L409*W256*H297 mm | Around 48.5lb / Around 22Kg |
Output Specs
AC Out | USB-A*4 | USB-C*2 | DC 5525 Output*2 | Cigar Port*1 | Wireless Charger*1 |
---|---|---|---|---|---|
Pure sine wave 100V~120V Rated 2000W |
5V-2A*3 (Max 6A total) 5V,9V,12V, Max 18W*1 |
(5V,9V,12V, Max 18W)*1 (5V,9V,12V,20V, Max 100W)*1 |
DC 12V-3A | DC 12V-10A | Max 15W |
Input Specs
GX16MF*2 | DC Charging(32V~95V) Max 1200W(600W*2) |
---|---|
5521*1 | DC Charging(12V~18V) Max 100W |
How to Use the E2000 LFP
Powering On/Off:
- Press and hold the DC/USB/Wireless Switch (5) to turn on/off the DC, USB, and Wireless charging functions.
- Press and hold the AC Switch (6) to turn on/off the AC output. Please turn off the AC function if there is no AC load on the unit to conserve power.
LCD Smart Display
The LCD display provides critical information:
- Battery Icon: Indicates the remaining battery percentage.
- Temperature Alarm Icon (Thermometer Symbol ?️): Flashes if the working temperature exceeds 45°C, potentially causing the unit to stop working. The operating temperature range is -20°C to 45°C.
- AC Overload Alarm Icon (Triangle with Exclamation Mark ⚠️): Flashes if the connected device's power consumption exceeds the 2000W limit, causing the AC power supply to stop.
- DC OUT: Shows the power output from DC ports.
- AC OUT: Shows the power output from AC ports.
- Net Input/Output Wattage: Displays the real-time power flow.
- DC Out Voltage/Current: Displays the voltage and current from DC outputs.
- AC Input Wattage(W)/Voltage(V): Displays the power and voltage being supplied to the unit for charging.
- AC Out Voltage/Frequency: Displays the output voltage and frequency of the AC ports.
- Battery Soc(%): Displays the State of Charge of the battery in percentage.
- Voltage(V): Displays the battery voltage.
- PF Value/Remaining Charging/Discharging Time(Hrs): Shows the Power Factor and estimated remaining time for charging or discharging.
- Time Indicator: General time indicator.
- Charge Indicator: Shows when the unit is actively charging.
- Discharge Indicator: Shows when the unit is actively discharging.
Expandable Battery
The capacity of the E2000 LFP can be expanded by connecting additional Pecron 24V battery modules using a Pecron battery expansion cable. Important: Only use Pecron-approved battery modules to avoid damaging the unit.
The battery expansion port is located on the side of the unit and is designed for DC 24V expansion.
Packing List
The package typically includes:
- Pecron E2000 LFP unit *1
- AC Charger *1 (An extra can be purchased separately)
- MC4 Solar Charging Cable (LSMC4-5GX16)*2
- Car Charging Cable *1
Recharge Time
Recharge times vary depending on the charging method:
- Wall Charger: Around 3.5~4 Hours (Standard), Around 1.5~2 Hours (with 2 adapters).
- Electric Generator: Around 3.5~4 Hours (Standard), Around 1.5~2 Hours (with 2 adapters).
- Car Charger: Around 20 Hours.
Solar Charge Time
The E2000 LFP features a built-in MPPT charge controller supporting 32V~95V PV charging up to 1200W. Solar charging time depends on weather conditions and the solar panel configuration.
Recommended Solar Panel Configurations:
- 1x Pecron 100W / 18V: Charges via the DC 5521 port (12V~18V, 100W maximum). The Open Circuit Voltage (VOC) of the solar panel must be less than 25V.
- 1x Pecron 200W / 36V: Charges via one of the GX16MF-5 ports (32V~95V, 600W maximum). The VOC must be less than 95V.
- 2x Pecron 200W / 36V (400W total): Can be wired in series or parallel. For series connection, the total voltage should not exceed 95V VOC. For parallel connection, ensure proper MC4 connectors are used.
- 3x Pecron 200W / 36V (600W total): Can be wired in parallel. DO NOT wire three 36V panels in series, as this will exceed the 95V VOC limit and damage the unit.
- 4x Pecron 200W / 36V (800W total): Can be wired in parallel. DO NOT wire four 36V panels in series, as this will exceed the 95V VOC limit and damage the unit.
- 6x Pecron 200W / 36V (1200W total): Can be wired in parallel using Y-branch MC4 cables.
Important Notes for Solar Charging:
- The PV(GX16MF-5) ports operate within a 32V~95V Open Circuit voltage range. Exceeding 95V will damage the machine.
- When connecting multiple panels in series, ensure the total voltage remains within the specified limits.
- For any questions regarding solar charging, please contact support@pecron.com.
FAQs
- Q1: What kind of battery is used in E2000 LFP? How long it can last?
- A: E2000 LFP utilizes high-quality UL certified automotive LiFePO4 battery. It can retain 80% of its original capacity at 3500 complete charge cycles.
- Q2: What devices can E2000 LFP power?
- A: E2000 LFP can power most devices with a power consumption less than 2000 watts.
- Q3: Can the E2000 LFP be used as UPS?
- A: The UPS function is not supported.
- Q4: Can the E2000 LFP be charged while discharging?
- A: Yes, the E2000 LFP can run devices while it is being charged. However, if the discharging power is greater than the charging power during pass-through charging, the battery will eventually run out.
- Q5: How to calculate the E2000 LFP running time?
- A: Running Time = Total Capacity (1920Wh) * 0.85 (Depth of Discharge) / Loading Power (Watts).
- Q6: Can I use the E2000 LFP indoors and charge the E2000 LFP indoors?
- A: Yes, the E2000 LFP is safe to use indoors.
- Q7: Does E2000 LFP have built-in MPPT controller?
- A: Yes, it has two independent 600W (PV 32V-95V) MPPT charge controllers and one step-up 100W (PV 18V) MPPT charge controller. The VOC (Open Circuit Voltage) of the solar panels should not exceed 95V.
- Q8: How to store the E2000 LFP?
- A: Store the unit in a dry, ventilated place at normal room temperature. Avoid water sources or moist environments. For long-term storage, discharge the battery to 30% every three months and recharge to 60% to prolong battery life.
Disclaimer
Read the user manual thoroughly before use and keep it for future reference. Failure to follow instructions may increase the risk of injury, death, or property damage. By using this device, you agree to all terms and conditions. Pecron reserves the right to change terms and conditions without prior notice. Revised terms will be posted on the website.
Warning
- Do not place the device near heat sources.
- Do not immerse in liquid or expose to rain/wet conditions.
- Do not use in strong static electricity or electromagnetic environments.
- Do not disassemble or puncture with sharp objects.
- Prevent short circuits caused by vermin, water, or fluids.
- Use only Pecron-approved accessories and parts. Visit www.pecron.com for details.
- Strictly follow the ambient temperature guidelines. High temperatures can cause self-combustion; low temperatures degrade performance.
- Do not stack heavy objects on the product.
- Do not block air vents during use or operate in non-ventilated/dusty spaces.
- Avoid impacts, falls, and violent vibrations. Turn off immediately if the unit experiences a major impact. Secure the unit during transportation.
- If the device is accidentally immersed in water, place it in a safe open area away from the unit until dry. Do not reuse; dispose of properly. In case of fire, use water/mist, sand, fire blanket, dry chemical, or CO2 extinguisher.
- Clean the surface with a dry cloth.
- Handle with care to prevent damage from falls. If damaged, turn off immediately, place in an open area away from combustibles, and dispose of according to local regulations.
- Keep out of reach of children and pets.
Disposal
- Completely discharge the battery before disposal. Place the product in a designated battery recycling box. Batteries are dangerous chemicals and must not be disposed of in ordinary trash. Follow local laws and regulations for battery recycling.
- If the battery cannot be discharged due to product failure, contact a professional battery recycling company.
- Over-discharged batteries may not start; dispose of them according to disposal principles.
Exclusions
Pecron's warranty does not cover misuse, abuse, modifications, accidental damage, or use outside normal consumer authorization.