CL54eN-ADV advansys ELECTRIC High Temperature Rack Conveyor Dishwashing Machine
Hobart
Specifier Statement
The specified dishwasher is the Hobart CL54eN Advansys electric tank heat model, featuring drain water energy recovery (DWER), automatic soil removal (ASR), and Opti-Rinse™. It offers a capacity of 245 racks per hour, insulated ergonomic cabinet-style doors, a dirty water indicator, configurable "intelligent" de-lime notification, top-mounted computer controls, and an NSF-approved pot and pan cycle mode. The wash tank utilizes durable precision pressure sensor monitors instead of conventional mechanical floats. The standard 19.5" chamber height accommodates up to (6) standard sheet pans at a time on an open-end sheet pan rack.
Standard Features
- 245 racks per hour
- Drain water energy recovery (DWER)
- Automatic soil removal (ASR)
- Opti-Rinse™ system
- Drain water tempering kit
- Rapid return conveyor drive mechanism
- Internal stainless steel pressure-less 30 KW booster heater
- Dual point electrical connection standard on 208/60/3 and 240/60/3 voltage machines; single point kits available (see page 3)
- Single point connection standard on 480/60/3 and 600/60/3 voltage machines
- Large double door opening for ease of cleaning
- Doors are insulated & hinged with door interlock switches
- 19.5" chamber height opening (accepts sheet pans)
- Top mounted micro-processor control module
- Energy saver mode (programmable auto-shut down)
- Dirty water indicator
- Manager activated low temperature alert
- NSF rated configurable pot and pan dwell mode
- Configurable “intelligent” delime alert notification
- Service diagnostics
- Self-aligning wash manifolds
- Stainless steel anti-clogging wash arms
- Removable pump intake screen
- Stainless steel self-draining pump and impeller
- Single, sloping scrap screen and deep scrap basket
- Stainless panels enclose perimeter and bottom
- Door actuated drain closure
- Vent fan control
- Booster heater control
- ENERGY STAR® Certified
Options & Accessories (Available at extra cost)
- Standard, short, and extended stainless steel vent hoods
- Direct drive unloader - adds 38" length. Reference spec F39520 for more details
- Side loader - SL23 adds 23" length, SL30 adds 30" length. Reference specs F40926 and F40927 for more details
- Blower-dryer – adds 33¼" to length. Reference spec F40252 for more details (ships separate from dishmachine, contact Hobart Service for installation)
- Flanged feet kit (requires two kits)
- Higher than standard chamber (24" opening)
- Table limit switch with 10' wire
- Correctional package (contact Hobart for details)
- Pressure regulator valve (PRV), for use with external booster
- Water shock absorber kit
- Factory-mounted circuit breakers (contact Hobart for details)
- Field installed single point kits available for 208/60/3 and 240/60/3 machines when equipped with internal booster
Diagrams and Dimensions
Top Views
Top View Left to Right: Shows overall width of 73 3/8", depth of 40 1/8", and height of 65 1/2". Indicates 20" service clearance on both sides and 23" open door clearance. Key connection points P1, P2, P3, E1, E2, E3, V1 are marked.
Top View Right to Left: Similar to the left view, showing dimensions 73 3/8" width, 40 1/2" depth, 65 1/2" height. Also indicates 20" service clearance and 23" door clearance. Key connection points P1, P2, P3, E1, E2, E3, V1 are marked.
Front Views
Front View Left to Right: Shows overall width of 31", depth of 73 3/8", and height of 68 1/2". Highlights the L-R OPER configuration and Automatic Soil Removal (ASR) connection point P1.
Front View Right to Left: Shows overall width of 31", depth of 73 3/8", and height of 68 1/2". Highlights the R-L OPER configuration and Automatic Soil Removal (ASR) connection point P1.
Side View
Side View: Shows dimensions: 65 1/2" height, 73 3/8" length, 15 1/8" depth. Indicates the 2" FPT Drain (P1) connection and a recommended minimum distance of 5" from the wall. Also shows the 13" tabling connection inside the tank.
Tabling Connection and Track Layout
Tabling Connection: 54" inside tank (at table connection).
Suggested Track and Table Layout: Illustrates a table layout with machine width of 27", track width of 20", and average inside table width of 27". Shows hole locations for bolting the table to the tank.
Legend and Connections
Electrical Connections
Single Point Electrical Connection (E1)
E1: Tank heat, motors, controls AND 30kW booster heater - multiple knockouts provided, 63-3/4" AFF.
Dual Point Electrical Connection (E2, E3)
E2: Tank heat, motors and controls - multiple knockouts provided, 63-3/4" AFF.
E3: Internal 30kW booster heater - multiple knockouts provided, 63-3/4" AFF. Multiple knockouts provided for 2", 1" and 1/2" trade size conduits.
Plumbing Connections
P1 (Drain): May be drained to either side of valve, plug opposite side 2" FPT. Recommend a floor drain minimum of 12" from machine for access and maintenance. 7-3/8" AFF.
P2 (Hot Water): 1/2" FPT connection. 1/2", 11-3/16" AFF. See plumbing notes for required temperatures.
P3 (Cold Water): 1/2" FPT, cold water temperature 80°F, maximum 7-3/8" AFF.
Vent Connections
V1: Optional vent hoods, 4" x 16" vent stack with damper.
Specifications
Capacities
Item | Value |
---|---|
Racks per Hour (NSF rated) | 245 |
Wash Tank (U.S. gallons) | 23 |
Conveyor Speed (feet per minute) | 6.8 |
Motor Horsepower
Motor Type | Horsepower |
---|---|
Drive | 1/6 |
Wash | 2 |
ASR | 1/2 |
Water Consumption
Parameter | Value |
---|---|
U.S. Gallons per Hour (maximum use at 20 PSI) | 138 |
U.S. Gallons per Rack | 0.56 |
Peak Drain Flow (U.S. gallons per minute) | 38 |
Heating
Heating Type | kW Rating |
---|---|
Tank Heat, Electric | 15 |
Electric Booster (built-in) (for 70°F rise) | 30 |
Venting
Vent Location | Minimum CFM |
---|---|
Load End | 200 |
Unload End | 400 |
Shipping Information
Item | Value |
---|---|
Shipping Weight (approximate) | 753 lbs. |
Crated Dimensions | 63"L x 38"W x 78"H |
Electrical Connection Details
Single Point Electrical Connection with Internal 30 kW Booster Heater
Voltage | (E1) Tank Heat, Motors, Controls Rated Amps | Minimum Supply Circuit Ampacity / Maximum Protective Device | Single Point Service Connection |
---|---|---|---|
208/60/3 | 138.9 | 175 | Field Installed SGLPT-KIT4-CLE required, order separately |
240/60/3 | 132.8 | 150 | Field Installed SGLPT-KIT2-CLE required, order separately |
480/60/3 | 68.0 | 90 | Ships Standard, Factory Installed |
600/60/3 | 47.1 | 60 | Ships Standard, Factory Installed |
Dual Point Electrical Connection with Internal 30 kW Booster Heater
Voltage | (E2) Tank Heat, Motors, Controls Rated Amps | Minimum Supply Circuit Ampacity / Maximum Protective Device | (E3) 30kW Booster Heater Rated Amps | Minimum Supply Circuit Ampacity / Maximum Protective Device | Dual Point Service Connection |
---|---|---|---|---|---|
208/60/3 | 55.0 | 70 | 83.9 | 90 | Dual Point Ships Standard |
240/60/3 | 52.6 | 70 | 80.2 | 90 | Dual Point Ships Standard |
480/60/3 | 27.9 | 40 | 40.1 | 50 | Field Convertible |
600/60/3 | 20.3 | 25 | 26.9 | 40 | Field Convertible |
Vent Hood Options
Vent stack can be adjusted 1" to either side.
Standard Vent Hood
10" vent stack height. Requires 4 3/4" outside clearance.
Short Vent Hood
10" vent stack height. Requires 4 3/4" outside clearance and 5 3/4" outside reference.
Extended Vent Hood
10" vent stack height. Requires 4 3/4" outside clearance and 20 1/2" outside reference.
Warnings and Notes
Warning: Plumbing and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and National Electrical Code.
Plumbing Notes: Minimum incoming water temperatures: 110°F for 30kW internal booster. Building flowing water pressure to dish machine is 20 PSI, (+/- 5 PSI). Single cold water connection supplies both drain water energy recovery and drain water tempering. Recommended water hardness to be 3 grains or less for best results.
Electrical Note: Dishmachine not provided with internal GFCI protection.
Electric Heat Dissipation
Heat Type | BTU/HR. |
---|---|
Latent | 42,200 |
Sensible | 18,100 |
Note: Additional CLeN Voltages and Amperages are available, see document F40972.
Certifications
ENERGY STAR Certified, NSF rated, UL Canada US.