Miller E7 Series Electric Furnaces
The E7 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low maintenance. Units may be installed free standing in a utility room or enclosed in an alcove or closet. E7 Series furnaces are A/C ready, with 16 blower speeds to meet any cooling requirement.
Features and Benefits
- Choice of Air Conditioning Options: From 1.5 to 5 tons A/C ready.
- Easy Open Door: Secures the door firmly for transit, yet allows easy removal for access.
- Effective Air Filter: Universal disposable filter is readily available and simple to replace.
- Nichrome Heating Elements: Provide long lasting, efficient heating.
- Appliance Quality Door: Protects against rust and other corrosion. Baked enamel finish allows for easy cleaning.
- Fully Insulated Furnace Cabinet: Insures minimized heat loss and quiet operation.
- Safety and Dependability: Auto reset controls protect unit's electrical circuitry and helps ensure trouble free performance. Built in circuit breakers for extra safety.
- Adaptable: Unit can be adapted to provide dependable heating in either downflow or upflow mode.
- Versatile: Works with self-contained or split system air conditioners or heat pumps.
- Heating Relays: Provide quiet operation.
- Control Board: Allows for 16 blower speeds to create ideal comfort in the home.
- 7 Segment LED Display: Shows furnace mode and simplifies service.
- Upflow/Downflow Furnace (E7EM): Available to meet any application.
- Upflow (E7EU) and Downflow (E7ED) Furnace: Comes with a factory installed coil box and all necessary filters.
- Full line of accessories: Available to meet many difficult applications.
Model Identification
The model number structure for the E7 Series furnaces provides key information:
E7E-M-010H1
- Product Type: E - Electric Furnace
- Generation: 7 - Seventh Series
- Blower: E - Constant Torque, 16 Speed ECM
- Blower Configuration: M - Upflow/Downflow, D - Downflow, U - Upflow
- Primary Capacity: 010 - 10 kW, 012 - 12 kW, 015 - 15 kW, 017 - 17 kW, 020 - 20 kW, 023 - 23 kW
- Electrical Code: H - 240-1-60
- Revision: 1
Furnace Parts Identification
The diagram shows a typical furnace unit with the following components labeled: 2 Pole Relay, Transformer, Control Board, Circuit Breaker, Limits, and Grounding Lug.
Unit Specifications
FURNACE MODELS E7- | 010H | 012H | 015H | 017H | 020H | 023H |
---|---|---|---|---|---|---|
Rated Heating Output, Btuh (see note 1) | 35,000 | 41,000 | 53,000 | 57,000 | 70,000 | 75,000 |
Watts (Total kw, Heating Elements & Blower) | 10.4 | 12.0 | 15.4 | 16.6 | 20.4 | 22.0 |
Supply Voltage | 240 Volts/60Hz/1-Phase | |||||
Heating Elements, No. (Total kw) | 2 (10.0) | 2 (11.6) | 3 (15.0) | 3 (16.2) | 4 (20.0) | 4 (21.6) |
Motor Speed, H.P. Rating, Amps | 16 Speed, 1/2 HP, 3.6 A | |||||
Test ESP, in. w.c. Max | 0.3 | |||||
Optional Cooling Available with factory installed blower | 2.0 - 4.0 Ton | |||||
Optional Heat Pump Available with factory installed blower | 2.0 - 4.0 Ton | |||||
Air Filter (Standard) | 18" x 20" x 1" (nominal) |
Note 1: Heating output rated at listed voltage. For outputs at voltages other than 240V, multiply Btuh rating by the following factors: x 0.92 (230V), x 0.84 (220V), x 0.75 (208V)
Furnace Dimensions
Multi-Poise: Width-20" (508mm), Height-29" (737mm), Depth-24 1/2" (623mm)
Upflow/Downflow: Width-20" (508mm), Height-60 5/8" (1546mm), Depth-24 1/2" (623mm)
Electrical Specifications
MODEL NUMBER E7E*- | SUPPLY CIRCUIT AMPERES | TOTAL AMPERES | MAXIMUM OVERCURRENT RATING | MINIMUM CIRCUIT AMPACITY |
---|---|---|---|---|
010H1 | Single 45.3 | 60 | 57 | 57 |
012H1 | Single 51.6 | 70 | 65 | 65 |
Dual "A" 27.8 | 35 | 35 | 35 | |
Dual "B" 24.2 | 35 | 30 | 30 | |
015H1 | Single 66.1 | 90 | 83 | 83 |
Dual "A" 45.3 | 60 | 57 | 57 | |
Dual "B" 20.8 | 30 | 26 | 26 | |
017H1 | Single 71.1 | 90 | 89 | 89 |
Dual "A" 45.0 | 60 | 56 | 56 | |
Dual "B" 26.1 | 35 | 33 | 33 | |
020H1 | Single 86.9 | 110 | 109 | 109 |
Dual "A" 45.3 | 60 | 57 | 57 | |
Dual "B" 41.7 | 60 | 52 | 52 | |
023H1 | Single 93.6 | 125 | 117 | 117 |
Dual "A" 45.3 | 60 | 57 | 57 | |
Dual "B" 48.0 | 60 | 60 | 60 |
NOTE: Wire size must be in accordance with the applicable revision of the NEC and all other applicable codes.
Anticipator Settings
Furnace Model | Thermostat Anticipator Setting |
---|---|
010, 012 | 0.2 |
015, 017, 020, 023 | 0.4 |
Clearances
ALL MODELS | CLOSET | ALCOVE | |
---|---|---|---|
Front ‡ | 6" | 18" | |
Back | 0" | 0" | 0" |
Sides | 0" † | 0" † | 0" † |
Top | 0" | 0" | 0" |
Top and Sides of Duct | 0" | 0" | 0" |
Bottom of Duct | 0" | 0" | 0" |
‡ Service Clearance
† For upflow application using upflow stand, 1" minimum per side.
Physical Dimensions
E7EM Physical Dimensions
The E7EM model dimensions are provided from multiple views. Top view: 17 inches by 20 inches. Front view: 20 inches wide. Left side view indicates dimensions related to the VentilAire Bracket attachment location. Right side view shows dimensions for refrigerant line knockout (1.5 x 5 inches), electrical knockouts (various sizes), and T-stat connection. Bottom view shows overall depth and A.C. & H.P. knockout dimensions.
E7EU & E7ED Physical Dimensions
The E7EU and E7ED models share similar physical dimensions. Top view: 17 inches by 20 inches. Front view: 20 inches wide. Left side view shows VentilAire Bracket attachment location. Right side view details electrical and T-stat connections. Bottom view shows overall depth and A.C. & H.P. knockout dimensions. The E7EU has a solid door and is oriented opposite to the E7ED.
E7 Furnace Upflow Stand Dimensions
The E7 Furnace Upflow Stand dimensions are detailed across Top, Front, Left Side, Right Side, and Bottom views, showing various measurements for its structure and attachment points.
Optional Accessories: Coil Cabinets
A table lists available coil cabinets with their part numbers and dimensions:
Coil Box | Dimension A Width (mm) | Dimension B Depth (mm) | Dimension C Height (mm) |
---|---|---|---|
1006730 | 20" (508mm) | 24" (610mm) | 31.5" (802mm) |
1006731 | 20" (508mm) | 24" (610mm) | 31.5" (802mm) |
904067 | 20" (508mm) | 24" (610mm) | 27" (686mm) |
902976 | 20" (508mm) | 24" (610mm) | 29" (736mm) |
Airflow Data
Airflow (CFM) vs. External Static Pressure (In. W.C.)
The following table details airflow in CFM for various motor switch settings and external static pressures for E7E*-0**H1 models:
MODEL NUMBER E7E*-0**H1 | MOTOR SWITCH SETTINGS (0=OFF, 1=ON) | EXTERNAL STATIC PRESSURE (IN. W.C.) | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/5 | 2/6 | 3/7 | 4/8 | 0.1 CFM | 0.2 CFM | 0.3 CFM | 0.4 CFM | 0.5 CFM | 0.6 CFM | |
0 | 0 | 0 | 0 | 685 | 640 | 606 | 560 | 513 | 460 | |
1 | 0 | 0 | 0 | 770 | 727 | 692 | 648 | 599 | 552 | |
0 | 1 | 0 | 0 | 854 | 815 | 779 | 737 | 685 | 645 | |
1 | 1 | 0 | 0 | 939 | 902 | 865 | 825 | 771 | 737 | |
0 | 0 | 1 | 0 | 1,012 | 974 | 938 | 899 | 850 | 813 | |
1 | 0 | 1 | 0 | 1,084 | 1,047 | 1,011 | 973 | 930 | 888 | |
0 | 1 | 1 | 0 | 1,157 | 1,119 | 1,084 | 1,047 | 1,009 | 964 | |
1 | 1 | 1 | 0 | 1,197 | 1,166 | 1,130 | 1,093 | 1,056 | 1,017 | |
0 | 0 | 0 | 1 | 1,245 | 1,215 | 1,178 | 1,143 | 1,105 | 1,066 | |
1 | 0 | 0 | 1 | 1,293 | 1,263 | 1,225 | 1,192 | 1,154 | 1,114 | |
0 | 1 | 0 | 1 | 1,344 | 1,312 | 1,278 | 1,242 | 1,206 | 1,169 | |
1 | 1 | 0 | 1 | 1,394 | 1,361 | 1,330 | 1,291 | 1,257 | 1,223 | |
0 | 0 | 1 | 1 | 1,434 | 1,401 | 1,369 | 1,332 | 1,299 | 1,267 | |
1 | 0 | 1 | 1 | 1,473 | 1,441 | 1,408 | 1,373 | 1,340 | 1,311 | |
0 | 1 | 1 | 1 | 1,514 | 1,483 | 1,451 | 1,417 | 1,386 | 1,355 | |
1 | 1 | 1 | 1 | 1,555 | 1,525 | 1,494 | 1,460 | 1,431 | 1,398 |
NOTES:
1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, and 4. For cooling speeds use COOL switches 5, 6, 7, and 8.
2. Data is shown with filter.
Maximum Heating Airflow Settings
The following table shows maximum airflow settings for E7EM, E7ED, and E7EU models based on capacity and application (MH/RES):
E7E*-0**H1 | E7EM | E7ED | E7EU | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
DOWNFLOW | UPFLOW | DOWNFLOW | UPFLOW | DOWNFLOW | UPFLOW | |||||||
MH | RES | MH | RES | MH | RES | MH | RES | MH | RES | MH | RES | |
10 | 0101 | 0001 | 0001 | 0101 | 0101 | 0101 | 0101 | |||||
12 | 0011 | |||||||||||
15 | 0101 | 0101 | 0101 | 0101 | 0101 | |||||||
17 | 0001 | |||||||||||
20 | 0011 | 0001 | ||||||||||
23 | 0011 | 0011 |
NOTES:
1. MH and Res represent Manufactured Housing and Residential (modular home) applications, respectively.
2. To comply with government mandated efficiency standards, speed settings with higher CFM values than listed in this table are not allowed in HEAT mode.
Accessories
Description | Part Number |
---|---|
Blower, 5 Ton | 1027059 |
Heating Thermostat Intertherm (12 Pac) | 903188 (903182) |
Heating Thermostat Miller (12 Pac) | 903189 (903183) |
Thermostat Sub-Base | 914146 |
Heating/Cooling Thermostat CM65 Intertherm/Miller (12 Pac) | 903992 (903993) |
Heating/Cooling Thermostat GE Intertherm (12 Pac) | 903192 (903186) |
Heating/Cooling Thermostat GE Miller (12 Pac) | 903193 (903187) |
Automatic Damper for AC or HP Package Unit | 901083 |
"VEE" Box Adapters (10") - 5 / carton | 901985 |
Duct Connector 10" Dia. x 6" Long - 6 / carton | 902926 |
"VEE" Box Adapters (12") - 5 / carton | 902149 |
Single Wide Fitting Kit (12") | 911468A |
Double Wide Fitting Kit (12") | 911469A |
Single Wide Fitting Kit (14") | 914957 |
Double Wide Fitting Kit (14") | 914956 |
Y-Fitting (12") | 911470 |
Y-Fitting (14") | 917195 |
Fan Delay Kit (TDR) | 911758 |
Top Grille/Frame | 902989 |
Top Grille/Frame (4 pack) | 903000 |
Cabinet to Combine w/ Grille/Frame | 903891 |
Upflow Stand | 1014501 |
Coil Cabinet (For all sizes), Upflow & Downflow w/ Solid Door | 1006730 |
Coil Cabinet (For all sizes), Upflow & Downflow w/ Louvered Door | 1006731 |
Coil Cabinet Downflow (Front return) | 904067 |
Coil Cabinet Upflow (Solid door, limited capacities) | 902976 |
Accessory Kits
Vent Kits
Vent Kits | Part Number |
---|---|
Soffit Air Inlet (for VentilAire III only) | 917201A |
VentilAire III - Sloped 3/12 | 914098 |
VentilAire IV - Sloped 3/12 | 914229 |
VentilAire V - Sloped 3/12 | 1018547 |
Plenum Connectors
Plenum Connectors | Part Number | |
---|---|---|
11.25 x 13.50 x 0.88 | 12 / carton | 901987A |
11.25 x 13.50 x 2.00 | 12 / carton | 901988A |
11.25 x 13.50 x 4.25 | 6 / carton | 901989A |
11.25 x 13.50 x 6.25 | 6 / carton | 901990A |
11.25 x 13.50 x 8.25 | 4 / carton | 901991A |
11.25 x 13.50 x 10.25 | 3 / carton | 901992A |
11.25 x 13.50 x 12.25 | 3 / carton | 901993A |
11.25 x 13.50 x 6.25 | 24 / carton | 902681A |
General Terms of Limited Warranty
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (06/2021)
For more information, visit www.millerac.com.