User Manual for COXTOD models including: JAY-1, JAY-1 Portable Oxygen Concentrator, Portable Oxygen Concentrator, Oxygen Concentrator, Concentrator
File Info : application/pdf, 6 Pages, 2.38MB
DocumentDocumentCOXTOD Contents 1 Foreword....................................................................................1 2 Safety notice...............................................................................1 3 Product introduction...................................................................4 D 4 Using condition...........................................................................4 5 Scope of application...................................................................4 O6 Technical parameter...................................................................4 7 Name and function...................................................................5 8 Operation steps........................................................................6 T9 Maintenance.............................................................................6 10 Troubles and solution.............................................................8 X 11 Condition for transportation and storage................................8 CO 12 Quality warranty.....................................................................8 1 Foreword Before Installation Thank you for purchasing our products, hoping you will be satisfied with our products. This operation manual contains function, operation steps, attention, basic trouble solution and so on. To ensure your efficient use of the machine, please have a close read of this operation manual before Damage:Only use stable and safe electrical power sources. Damage: If the electrical power source becomes unstable, discontinue use. Placement operating. ATTENTION: The oxygen concentrator should be set to use in an environment without dust, Maybe, there are some pictures, which are different from what you have seen in the real model in this manual. YOU MUST DO ACCORDINGLY BEFORE START THE MACHINE! TOD White tie Cut and pull out 2 Safety notice X This product cannot be used for life saving, it is suggested that if any patient who needs oxygen treatment, please follow doctor's advice to choose the right flow and period for oxygen before using the machine. O Please note the following special statements,used throughout this manual,and their significance: Note:Explanatory information. C Damage: Action could result in damage to equipment. corruption or toxicological harm gas. ATTENTION: The oxygen concentrator should be located in well-ventilated space, in case there are polluted air or smog in the oxygen. ATTENTION: Always place the concentrator on a hard surface. Never place the concentrator on a surface such as bed or couch, where the concentrator may tip or fall. Fire Warning WARNING: For oxygen can be combustion-supporting, keep oxygen concentrator far away from naked light or fire resource, no smoking or naked light around the patient. WARNING: Keep the concentrator away from flammable and explosive areas. WARNING: Textiles and other materials that normally would not easily burn, can ignite and burn with great intensity in oxygen enriched air. WARNING: A spontaneous and violent ignition may occur if oil, grease or greasy substances come in contact with oxygen under pressure. ALWAYS keep these substances away from the oxygen concentrator. Maintenance ATTENTION: Before cleaning the dust on the net of oxygen concentrator, the plug must be pulled out in case electric attack. ATTENTION: The filter cotton and filter are the items needed to clean, among which external filter cotton should be cleaned every 100 hours, and internal filter should be cleaned every 300 hours. Radio Frequency Interference Most electronic equipment is influenced by Radio Frequency Interference (RFI). When there is strong electromagnetic interference, maybe the LCD will be slightly affected, but the machine is still running. ATTENTION: Action could result in personal injury. ALWAYS exercise CAUTION with regard to the use of portable communications equipment in the area WARNING: Action could result in fire and explosion. ATTENTION: Consult Instructions For Use. The date of Manufacturer around such equipment. Additional Safety Warnings WARNING: Do not put nasal tube under bed or cushion, the oxygen that caused by machine turning on without breathing may be combustion-supporting. The Manufacturer WARNING: DO not reach for a concentrator that has fallen into water. UNPLUG IT 1 2 IMMEDIATELY. WARNING: NEVER leave the concentrator unattended when plugged in. ATTENTION: ALWAYS supervise closely when this product is used near children or those who tube is made of medical PVC, and if it is thrown away, it could not be bio-degradable,so it will cause the pollution.Any material of the system, that may cause pollution in the environment, must be collected disposed strictly complied with the local rules and requirement require close supervision. ATTENTION: If any adverse reaction appeared or revealed during taking oxygen , please contact 3 Product introduction with equipment supplier or doctor as soon as possible. JAY-1(JAY-5P) product adopt pressure swing adsorption principle, which can separate oxygen, ATTENTION: Turn off the switch if no body takes oxygen. ATTENTION: In using the machine, do not open the cover at all. In case there are quality problem, do not dismantle it secretly. Any alarm or other abnormal phenomenon has been found, connect with equipment supplier or factor. D ATTENTION: Ensure the bottom smooth exhaustion during operating, or else the machine will be over-heated. ATTENTION: There is intermitted exhaustion sound during operating (10 seconds in intermission). O ATTENTION: 5 minutes are needed from oxygen concentrator from warming up to reach regular function. ATTENTION: The machine is only for healthcare use oxygen supply, and the oxygen concentration will be up to 90% when air outlet reaches its nominal flow. T ATTENTION: Do not turn on or off frequently, To restart the machine after turning off, no less than 5 minutes are necessary (namely, exhaust internal gas of the machine completely, for if air compressor turns on with pressure, its life will be shortened ) X ATTENTION: Refresh the water in the dampen bottle every 2-3 days, especially in summers. If do not use it in several days, please pour out the water completely, and wipe dry the bottle. ATTENTION: Use the oxygen tube with the machine or those of the same model, if change to use other model devices, please ensure close connection with the oxygen concentrator. The O absorbing oxygen tube is only for the patient, and do not junk it at will. ATTENTION: The oxygen tube, oxygen mask that have touched with the patient should keep C clean, disinfected and sterilized. nitrogen and other gas from the air, at constant temperature, as soon as power is connected, the oxygen that meets medical use standards can be separated from air constantly. Oxygen is generated by pure physical method. The concentrator can supply ONE patient with steady oxygen flowing out, safe and reliable, low cost, adjustable flow. The key parts of the concentrator adopt anti-tiring and antiaging design, and the planned life of the whole concentrator reaches up to 20,000 hours. There is no influence on indoor oxygen percent during the concentrator operating. 4 Using condition Ambient temperature: 10-40 Relative humidity: 30%-85% Air pressure: 700 hPa-1060 hPa No corrosive gas and strong magnetic field around. 5 Scope of application: This device is mainly used for generating health care use oxygen. 6 Technical Parameter Model description: JAY-1 J (company symbol ) A (company symbol) Y (oxygen) 1 (1 liter per minute of oxygen) Model Rated power (W) Operation voltage (V/Hz) Oxygen flow (L/Min) JAY-1 85 AC220/50 AC110/60 1-5 ATTENTION: The oxygen tube that have touched with the patient after each operation should be Oxygen concentration (%) 91%-38% disinfected by wiping it with 75% medical use alcohol or other disinfecting methods. To prevent Outlet pressure ( Mpa ) Alarm 0.041 Power failure cross infection, do not share oxygen tube. Sound level (dB) 45 Requirement of environment protection The materials used in the system won't create environment hazard. The packing materials of the LCD display Net Weight (Kg) Dimension (mm) accumulating timing; present timing; timing; 6 350(length)*190(width)*320(height) system are recyclable, and they must be collected and disposed according to the related regulation in Fuse F2A/250V the country or region where the package of the system or its accessories is opened. The nasal oxygen Vehicle Power Input: DC 12V Output:AC220V/200W 3 4 7 Name and Function 8 Operation steps 1. Connect the harness to both Oxygen concentrator & home power supply plug, Press the switch to start the machine. D Indicating Lamp Total 2 indicating lights, and the code of them are 1,2 from left to right, and their indication for each O model are as follows: O.P.: power switch (green lamp) P.F.: power failure(red lamp) Power switch T Knob of oxygen flow meter switch The other name of knob of oxygen flow meter switch is flow control valve.It adjusts and controls the outlet oxygen flow.Do not rotate it over-forced, or else it is easy to damage the valve core. Rotate it counterclockwise to turn on, clockwise to turn off. X Intake air filter Once need to replace, replace it by special filter for the machine LCD display O When the oxygen concentrator begin to run, and In one minute, the C LCD shows the accumulating timing. 2. Adjust the flowmeter knob, the float ball center position aligned with the scale(counter-clockwise on and clockwise off) 3. Insert the intake end of absorbing oxygen tube onto the oxygen outlet, then set the absorbing oxygen tube over patient's ears, insert the nasal tube into patient's nostrils to absorb oxygen; the best absorbing time for health care keeps 40-50 minutes per time, absorbing time for medical treatment shall be followed doctor's advice. 4. Once the oxygen therapy finished, press the switch to shut down the machine, please also un-plug the power supply at the same time. 5. In case oxygen concentrator is connected with power but the whole machine is still in the state of power off with alarm sound, please check out the connection part of power whether it is in good connection, or whether there is a power off in external power supply. After one minute, the LCD shows the present timing automatically. Timing keys The two buttons are used for timing adjustment, and press the left key(+) on to increase timing by adding 10min. And press the right key (- ) on to decrease timing by reducing 10min. the right key (- ) to reduce timing to "0", the machine will turn off automatically. The max timing time is 10 hours. Back label Power socket 9 Maintenance 1. In the condition of power off, make a clean for the outside body by soft towel with little detergent, and then wipe it up with dry towel, once or twice per month. 2. It is a critical step for daily maintenance to clean filter net for gas intake, at least twice a month. Detail steps: take off the filter net, clean them with detergent and wash it clearly with clean water completely, get ride of extra water and dry up naturally, finally set back after dry up. 5 6 10 Troubles and solution No. Trouble Causes Solution 1. No connection between circuit 1. Check out whether switch, plug, of oxygen concentrator and power line in good connection. 1 No operation after power 2. Replace the fuse protector and power connected 2. Circuit of fuse protector broken find the cause Air intake window 3. Clean secondary filter Clean secondary filter an interval about 300 hours, open the air intake window, then open the secondary filter cover in an anticlockwise direction and take off filter cloth, then clean it with D detergent, and then clean it out with clean water completely, get rid of the extra water, and dry it naturally, finally set back after dry up. TO Secondary filter 4. Fuse replacement X The fuse is located in the internal control PCB, please contact the professional service people to CO . changethisfuse. 3. Capacitor of compressor broken 3. Replace start capacitor 4. Compressor broken 4. Have the compressor replaced 1. Folded inside oxygen tube, no 1. Connect the oxygen tube again 2 No oxygen out or smooth outtake 2. Clean the filter tiny outtake flow 2. Filter clogged, no smooth intake 3. Open the cover and check the 3. Some pipes are leakage. gas pipes. 1. Air controller cannot work 1. Have air control valve replaced 3 No exhaust sound 2. Electrical control board cannot 2. Have electric control board work replaced 4 Too noisy exhaustion 1. The joint of exhaustion muffler fallen off 2. Exhaustion muffler broken 1. Connect the joint well 2. Have the muffler replaced 11 Condition for transportation and storage Environment temperature scale: -20-45 Comparative humidity scale: 95% Air pressure scale: 500--1060 hPa 12 Quality Warranty Scale for the whole machine repair: 15 months upon arrival of the goods Note: Please do place the machine at a good ventilation area, please make sure that the radiation port underneath the machine will not be covered. FUSE 5. The battery of JAY Series medical oxygen concentrator model adopt NI-MH charge battery(3.6V/20mAh),it is welded on the main board and there is a charge circuitry in the board, so it could be used by a long time. But if you could not use the oxygen concentrator continually, the battery will be at the dormancy state and its life will be shorter. So please charge the battery one time every month if you could not use the oxygen concentrator continually. 7 8